The SWEMED Bilirubin Total & Direct Reagent Kit – 2 × 50 mL is a professional clinical biochemistry reagent system intended for the quantitative determination of Total Bilirubin and Direct Bilirubin in human serum.
The kit uses the Modified Jendrassik & Grof method and is supplied as a ready-to-use reagent system for routine clinical chemistry testing in diagnostic laboratories, pathology laboratories, hospitals and other professional IVD environments. SWEMED’s current 2 × 50 mL configuration is listed as BIL100.
Product Name: Bilirubin Total & Direct Reagent Kit
Brand: SWEMED
Manufacturer: SWEMED Biomedicals Pvt. Ltd.
Product Category: Laboratory Reagent / Clinical Chemistry Reagent
Subcategory: Biochemistry Reagent / Liver Function Test Reagent
Test Parameters: Total Bilirubin and Direct Bilirubin
Methodology: Modified Jendrassik & Grof Method
Reagent Type: Ready-to-Use Liquid Reagent System
Pack Size: 2 × 50 mL
Total Reagent Volume: 100 mL
Pack Reference: BIL100
Pack Configuration: Bilirubin Total 1 × 50 mL + Bilirubin Direct 1 × 50 mL + Activator
Sample Type: Serum
Measurement Type: Quantitative Bilirubin Determination
Analyser Compatibility: Compatible open-system semi-auto and fully automatic biochemistry analysers, subject to analyser programming and validation
Intended Use: Professional in-vitro diagnostic laboratory testing
Suitable Users: Diagnostic laboratories, pathology laboratories, hospitals and clinical chemistry laboratories
Storage: 15–30°C, protect from light and contamination
Seller: Microsidd India
SWEMED’s current IFU identifies the BIL100 kit as a 2 × 50 mL pack, with one 50 mL Total Bilirubin reagent, one 50 mL Direct Bilirubin reagent and an activator.
The SWEMED Bilirubin Total & Direct Reagent Kit is an in-vitro diagnostic reagent system used for quantitative measurement of bilirubin in serum.
It measures two clinically important bilirubin fractions:
Total Bilirubin – the overall amount of bilirubin present in serum.
Direct Bilirubin – the conjugated fraction measured directly by the assay.
Bilirubin testing is commonly included in liver function testing and is used together with other clinical chemistry parameters such as SGOT/AST, SGPT/ALT, Alkaline Phosphatase, Albumin and Total Protein.
SWEMED lists the methodology as Modified Jendrassik & Graf’s / Jendrassik & Grof, depending on the manufacturer document wording.
The SWEMED Bilirubin Total & Direct Reagent Kit is intended for:
Bilirubin results should be interpreted together with other laboratory findings and appropriate clinical assessment.
The kit provides separate reagents for both Total Bilirubin and Direct Bilirubin, allowing laboratories to perform both measurements from one product configuration.
SWEMED states that the reagents and activator are ready to use, reducing working-reagent preparation requirements.
The reagent system uses SWEMED’s Modified Jendrassik & Grof methodology for bilirubin determination.
The BIL100 pack contains:
Bilirubin Total Reagent: 1 × 50 mL
Bilirubin Direct Reagent: 1 × 50 mL
Bilirubin Activator: 1 unit
Total reagent volume: 100 mL.
Bilirubin is an important clinical chemistry parameter frequently tested alongside liver enzymes and proteins.
Suitable for compatible open-system semi-automatic and fully automatic biochemistry analysers, subject to correct assay programming and laboratory validation.
The SWEMED Bilirubin assay is based on the Jendrassik & Grof reaction principle.
Bilirubin in the serum reacts with diazotized sulphanilic acid to form a coloured azobilirubin compound. The colour intensity generated is measured photometrically and is related to the bilirubin concentration in the specimen.
The kit contains separate reagent systems for Total Bilirubin and Direct Bilirubin, allowing the two fractions to be measured separately.
SWEMED’s IFU lists reagent components including sulphanilic acid, hydrochloric acid and an activator containing sodium nitrite.
The SWEMED Bilirubin Total & Direct Reagent Kit is intended for trained laboratory professionals working in:
This product is not intended for home self-testing.
Bilirubin Total Reagent: 1 × 50 mL
Bilirubin Direct Reagent: 1 × 50 mL
Bilirubin Activator: 1
Instructions for Use: 1
SWEMED’s IFU confirms this configuration for the 2 × 50 mL BIL100 pack.
The reagent should be used according to the current SWEMED Instructions for Use and the requirements of the compatible biochemistry analyser.
For routine laboratory use:
| Information | Details |
|---|---|
| Brand | SWEMED |
| Product | Bilirubin Total & Direct Reagent Kit |
| Parameters | Total Bilirubin + Direct Bilirubin |
| Method | Modified Jendrassik & Grof |
| Pack Reference | BIL100 |
| Pack Size | 2 × 50 mL |
| Total Reagent Volume | 100 mL |
| Total Bilirubin Reagent | 50 mL |
| Direct Bilirubin Reagent | 50 mL |
| Activator | Included |
| Sample | Serum |
| Format | Ready to Use |
| Storage | 15–30°C |
| Use | Professional IVD |
| Specification | Details |
|---|---|
| Product Name | Bilirubin Total & Direct Reagent Kit |
| Brand | SWEMED |
| Manufacturer | SWEMED Biomedicals Pvt. Ltd. |
| Analytes | Total Bilirubin / Direct Bilirubin |
| Methodology | Modified Jendrassik & Grof |
| Pack Reference | BIL100 |
| Pack Configuration | 1 × 50 mL Total + 1 × 50 mL Direct |
| Total Volume | 100 mL |
| Activator | Included |
| Specimen | Serum |
| Reagent Format | Ready-to-Use Liquid Reagent System |
| Storage | 15–30°C |
| Light Protection | Required |
| Product Type | Clinical Biochemistry IVD Reagent |
SWEMED’s IFU states that the reagents are stable at 15–30°C until expiry, provided they are protected from light and contamination, and also states do not freeze.
Proper handling is especially important with bilirubin testing because bilirubin is photosensitive.
SWEMED’s IFU states:
SWEMED also notes that direct sunlight can significantly reduce bilirubin concentration in serum samples, so proper specimen protection from light is important.
https://microsidd.com/collections/chemicals-liquids
https://microsidd.com/collections/bio-chemistry-reagents
SWEMED Albumin Reagent Kit 2 × 50 mL
SWEMED Alkaline Phosphatase Reagent Kit 25 mL
SWEMED Amylase Reagent Kit 10 mL
SWEMED SGOT / AST Reagent
SWEMED SGPT / ALT Reagent
SWEMED Total Protein Reagent
Bilirubin ↔ SGOT ↔ SGPT ↔ ALP ↔ Albumin ↔ Total Protein
✓ SWEMED clinical biochemistry reagent
✓ Total + Direct Bilirubin in one kit
✓ 2 × 50 mL professional pack
✓ Ready-to-use reagent system
✓ Modified Jendrassik & Grof method
✓ Activator included
✓ Suitable for compatible open-system analysers
✓ Ideal for routine liver function testing
✓ Related SWEMED biochemistry reagents available
✓ Microsidd India – Bengaluru
✓ Delivery to serviceable locations across India
It is a professional clinical chemistry reagent system for the quantitative determination of Total Bilirubin and Direct Bilirubin in serum.
SWEMED lists the method as Modified Jendrassik & Grof / Graf’s Method.
The pack size is 2 × 50 mL, providing 100 mL total reagent volume.
The 2 × 50 mL configuration is BIL100.
The kit includes 1 × 50 mL Total Bilirubin reagent, 1 × 50 mL Direct Bilirubin reagent, Bilirubin Activator and IFU.
Yes. SWEMED states that the reagents and activator are ready to use.
SWEMED specifies serum.
Bilirubin is photosensitive. SWEMED notes that exposure to direct sunlight can significantly reduce bilirubin concentration in serum samples.
SWEMED advises not to use haemolysed or lipemic serum for this assay.
Yes, with compatible open-system semi-automatic biochemistry analysers, subject to correct programming and validation.
Yes, with compatible open-system fully automatic analysers, subject to analyser requirements.
Store at 15–30°C, protected from light and contamination, and do not freeze.
Yes. Total and Direct Bilirubin are routinely included among clinical chemistry parameters used in liver-function assessment.
No. It is a professional in-vitro diagnostic laboratory reagent.
This product is non-returnable and non-exchangeable.
Please verify the brand, model, compatibility, pack size and product specifications before placing your order.
For laboratory reagents, customers should specifically verify the required test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
The SWEMED Bilirubin Total & Direct Reagent Kit is intended for professional in-vitro diagnostic laboratory use.
Testing should be performed by appropriately trained laboratory personnel according to the manufacturer’s current Instructions for Use, compatible analyser instructions, laboratory SOPs and quality-control procedures.
Bilirubin results should not be interpreted in isolation and should be considered together with other laboratory findings, patient history and appropriate clinical assessment.
storage 2 to 8 degree
| Specification name | Specification Value |
|---|---|
| Chemical grade | Laboratory |
| Color pattern | White |
| Test method | Lab analysis |
| Test sample | Blood |