The Swemed LFT Reagent Combo Kit from Microsidd.com combines the core clinical biochemistry reagents commonly required for routine Liver Function Test (LFT) profiles into one convenient professional laboratory procurement bundle.
This combo covers:
SGOT / AST + SGPT / ALT + Total Bilirubin + Direct Bilirubin + Alkaline Phosphatase + Total Protein + Albumin
These parameters help laboratories evaluate different aspects of liver-associated enzyme activity, bilirubin metabolism and circulating protein status.
Every reagent supplied in this combo remains an individual Swemed Diagnostics IVD product in its own original pack. Microsidd India groups the products together only to simplify procurement for pathology laboratories, diagnostic centres, hospitals and clinical chemistry facilities.
Swemed's clinical chemistry range identifies SGOT and SGPT as Modified IFCC assays, Bilirubin as a Modified Jendrassik & Graf method, Alkaline Phosphatase as a pNPP method, Total Protein as Biuret and Albumin as BCG.
Important: This is a Microsidd-created commercial procurement combo of individually packed Swemed reagents. It is not represented as a single factory-manufactured multiparameter Swemed kit.
| Included Reagent | Parameter Covered | Method |
|---|---|---|
| Swemed SGOT Reagent | AST / SGOT | Modified IFCC |
| Swemed SGPT Reagent | ALT / SGPT | Modified IFCC |
| Swemed Bilirubin Total & Direct Kit | Total + Direct Bilirubin | Modified Jendrassik & Graf |
| Swemed Alkaline Phosphatase Reagent | ALP | pNPP Kinetic |
| Swemed Total Protein Reagent | Total Protein | Biuret |
| Swemed Albumin Reagent | Albumin | BCG |
The bundle therefore provides reagents for 7 routinely reported LFT parameters through 6 Swemed reagent products.
| Reagent | Microsidd Listing Pack |
|---|---|
| SGOT / AST | 50 ml – R1 40 ml + R2 10 ml |
| SGPT / ALT | 50 ml – R1 40 ml + R2 10 ml |
| Bilirubin Total & Direct | 2 × 50 ml |
| Alkaline Phosphatase | 25 ml |
| Total Protein | 2 × 50 ml |
| Albumin | 100 ml – 2 × 50 ml |
Swemed's Albumin literature confirms its 100 ml configuration as 2 × 50 ml reagent + 3 ml standard.
| LFT Parameter | Included? | Laboratory Relevance |
|---|---|---|
| SGOT / AST | ✅ | Hepatic and extra-hepatic enzyme activity |
| SGPT / ALT | ✅ | Liver-associated transaminase |
| Total Bilirubin | ✅ | Overall bilirubin concentration |
| Direct Bilirubin | ✅ | Conjugated bilirubin |
| Indirect Bilirubin | Calculated | Total − Direct Bilirubin |
| Alkaline Phosphatase | ✅ | Hepatobiliary and bone-associated enzyme |
| Total Protein | ✅ | Overall circulating protein |
| Albumin | ✅ | Major plasma protein / synthetic function |
| Globulin | Calculated | Total Protein − Albumin |
| A/G Ratio | Calculated | Albumin-to-globulin relationship |
| GGT | Not included | Separate reagent if required |
This makes the bundle suitable for a core routine LFT panel. Laboratories requiring GGT or additional specialised hepatic parameters should procure them separately.
| Parameter | Method | Wavelength | Assay Type |
|---|---|---|---|
| SGOT / AST | Modified IFCC | 340 nm | Kinetic UV |
| SGPT / ALT | Modified IFCC | 340 nm | Kinetic UV |
| Bilirubin Total | Modified Jendrassik & Graf | 546 nm | Endpoint |
| Bilirubin Direct | Modified Jendrassik & Graf | 546 nm | Endpoint |
| Alkaline Phosphatase | pNPP | 405 nm | Kinetic |
| Total Protein | Biuret | 546 nm | Endpoint |
| Albumin | BCG | Typically visible-range photometric | Endpoint |
Swemed's Bilirubin insert specifies 546 nm, while the Alkaline Phosphatase insert specifies 405 nm and a kinetic procedure.
The Swemed SGOT / AST Liquid Stable Reagent uses the Modified IFCC kinetic UV method.
| Specification | Details |
|---|---|
| Pack | 50 ml |
| Configuration | R1 40 ml + R2 10 ml |
| Method | Modified IFCC |
| Wavelength | 340 nm |
| Mode | Kinetic |
| Sample Volume | 100 µl |
| Working Ratio | 4 parts R1 + 1 part R2 |
| Linearity | Up to 300 U/L |
| Storage | 2–8°C |
Swemed's current catalogue describes AST/GOT as a Modified UV-IFCC liquid-stable assay with working-reagent stability up to four weeks and linearity to 300 IU/L.
The Swemed SGPT / ALT Liquid Stable Reagent also uses the Modified IFCC kinetic UV method.
| Specification | Details |
|---|---|
| Pack | 50 ml |
| Configuration | R1 40 ml + R2 10 ml |
| Method | Modified IFCC |
| Wavelength | 340 nm |
| Mode | Kinetic |
| Sample Volume | 100 µl |
| Working Ratio | 4 parts R1 + 1 part R2 |
| Linearity | Up to 300 U/L |
| Storage | 2–8°C |
Swemed groups ALT/GPT and AST/GOT together as Modified UV-IFCC liver reagents.
The Swemed Bilirubin Total & Direct Reagent Kit enables measurement of both Total and Direct Bilirubin.
| Specification | Details |
|---|---|
| Parameters | Total + Direct Bilirubin |
| Method | Modified Jendrassik & Graf |
| Wavelength | 546 nm |
| Mode | Endpoint |
| Temperature | 37°C |
| Reagent Volume | 1000 µl |
| Sample Volume | 100 µl |
| Incubation | 10 minutes at room temperature |
| Factor | 15 |
| Linearity | Up to 20 mg/dL |
Indirect bilirubin can then be derived as:
Indirect Bilirubin = Total Bilirubin − Direct Bilirubin
Swemed's current technical insert specifies these parameters and a 20 mg/dL linearity.
The Swemed Alkaline Phosphatase (ALP) Reagent uses a pNPP kinetic method.
| Specification | Details |
|---|---|
| Pack | 25 ml |
| Method | pNPP |
| Mode | Kinetic |
| Wavelength | 405 nm |
| Temperature | 37°C |
| Sample Volume | 20 µl |
| Reagent Volume | 1000 µl |
| Factor | 2757 |
| Delay | 60 sec |
| Reaction Time | 180 sec |
| Linearity | Up to 700 U/L |
Swemed states that the ALP procedure is linear up to 700 U/L at 37°C.
The Swemed Total Protein Reagent uses the established Biuret Method.
| Specification | Details |
|---|---|
| Pack | 2 × 50 ml |
| Method | Biuret |
| Mode | Endpoint |
| Wavelength | 546 nm |
| Sample Volume | 20 µl |
| Reagent Volume | 1000 µl |
| Standard | 4 g/dL |
| Linearity | Up to 12 g/dL |
| Reagent | Ready to Use |
Swemed lists Total Protein as a Biuret-method clinical chemistry reagent.
The Swemed Albumin Reagent Kit uses the Bromocresol Green (BCG) Method.
Albumin binds with Bromocresol Green in a buffered medium to form a green-coloured complex, with colour intensity proportional to the amount of albumin present.
| Specification | Details |
|---|---|
| Pack | 100 ml – 2 × 50 ml |
| Method | BCG |
| Assay | Endpoint Photometric |
| Standard | 4 g/dL |
| Specimen | Serum / Heparin Plasma / EDTA Plasma |
| Reagent Preparation | Ready to Use |
| Reagent Storage | 15–25°C |
| Standard Storage | 2–8°C |
Swemed's Albumin insert confirms the 2 × 50 ml reagent presentation and 3 ml standard in its 100 ml kit.
The reagents in this combo can be used on compatible programmable open-system clinical chemistry analysers, subject to analyser capability and laboratory validation.
Because the included assays use several wavelengths, the analyser should support the relevant channels, particularly:
340 nm + 405 nm + 546 nm, together with the wavelength required for the laboratory's validated Albumin BCG application.
Each reagent must be programmed individually using its own assay settings.
The value of an LFT panel is that different parameters provide different laboratory information.
| Group | Parameters in Combo |
|---|---|
| Hepatocellular Enzymes | SGOT / AST + SGPT / ALT |
| Bilirubin Metabolism | Total + Direct Bilirubin |
| Cholestatic / Hepatobiliary Enzyme | Alkaline Phosphatase |
| Protein Status | Total Protein + Albumin |
| Calculated Parameters | Indirect Bilirubin, Globulin, A/G Ratio |
The combo also provides measured values from which laboratories may derive commonly reported calculated parameters.
Indirect Bilirubin = Total Bilirubin − Direct Bilirubin
Globulin = Total Protein − Albumin
A/G Ratio = Albumin ÷ Globulin
Calculated parameters should only be reported according to the laboratory's validated procedures and reporting policy.
Ordering a complete LFT reagent set can simplify procurement for laboratories that routinely run liver profiles.
Instead of purchasing each parameter separately, this bundle helps laboratories source the core reagents required for:
| Buyer Type | Typical Application |
|---|---|
| Pathology Laboratories | Routine LFT profiles |
| Diagnostic Centres | Health checks and liver testing |
| Hospital Laboratories | Clinical chemistry |
| Gastroenterology Centres | Liver-associated testing |
| Hepatology Centres | Liver profile assessment |
| Preventive Health Centres | Screening packages |
| Clinical Chemistry Laboratories | Routine biochemical testing |
| Medical Institutions | Teaching / diagnostic use |
| Corporate Health Laboratories | Screening programmes |
| Laboratory Distributors | Professional procurement |
| Buying Individually | Microsidd LFT Combo |
|---|---|
| Search 6 different reagent products | Core LFT products available in one listing |
| Risk of missing a parameter | Panel-oriented procurement |
| Multiple product comparisons | Methods summarised together |
| Separate purchasing workflow | Simplified ordering |
| Harder to compare analyser needs | Major wavelengths visible together |
| General marketplace listings may differ | Professional laboratory-focused listing |
Microsidd India specialises in diagnostic, IVD and laboratory products and has long-standing experience supplying professional healthcare products. This makes Microsidd's profile-based reagent bundles useful for laboratories seeking a more organised procurement workflow.
| Microsidd Advantage | Benefit to Laboratory Buyers |
|---|---|
| Diagnostic Product Specialisation | Better suited to professional reagent purchasing |
| Complete Core LFT Procurement | Multiple routine parameters in one listing |
| Swemed-Branded Reagents | One reagent brand across the profile |
| Technical Information | Method and analyser information available before purchase |
| Open-System Guidance | Helps laboratories verify analyser requirements |
| GST Invoice | Available for eligible purchases |
| Direct Seller Accountability | Purchase directly from Microsidd India |
| Bangalore-Based Operations | Convenient for Bengaluru / Karnataka laboratories |
| India-Wide Supply | Subject to serviceability |
| Related Reagent Range | Easier future replenishment |
This LFT Combo is commercially assembled by Microsidd India for procurement convenience.
Each included reagent remains an individual Swemed Diagnostics product in its original manufacturer pack.
This combo is not:
Every assay must be performed independently according to its specific Swemed instructions and validated laboratory procedure.
Microsidd India supplies LFT reagents, liver-function reagents and clinical biochemistry products from Bangalore / Bengaluru, Karnataka.
The Swemed LFT Reagent Combo Kit provides a convenient source for the principal reagents required by professional laboratories performing routine liver-function profiles.
Available through microsidd.com, subject to stock availability and delivery serviceability.
Relevant buyer searches include:
| Entity | Details |
|---|---|
| Product | LFT / Liver Function Test Reagent Combo Kit |
| Brand | Swemed Diagnostics |
| Included Products | SGOT, SGPT, Bilirubin Total & Direct, ALP, Total Protein, Albumin |
| Measured Parameters | 7 |
| SGOT Method | Modified IFCC |
| SGPT Method | Modified IFCC |
| Bilirubin Method | Modified Jendrassik & Graf |
| ALP Method | pNPP |
| Total Protein Method | Biuret |
| Albumin Method | BCG |
| Clinical Category | Liver Function Tests |
| Product Category | Laboratory Reagent Combo |
| Compatibility | Open-System Fully & Semi-Automatic Biochemistry Analysers |
| Seller | Microsidd India |
| City | Bangalore / Bengaluru |
| State | Karnataka |
| Country | India |
| Website | microsidd.com |
The Swemed LFT Reagent Combo Kit is a Microsidd-created professional laboratory bundle containing Swemed reagents for:
SGOT / AST + SGPT / ALT + Total & Direct Bilirubin + Alkaline Phosphatase + Total Protein + Albumin.
The six individual reagent products cover seven directly measured parameters:
SGOT, SGPT, Total Bilirubin, Direct Bilirubin, ALP, Total Protein and Albumin.
Additional values such as Indirect Bilirubin, Globulin and A/G Ratio may be calculated according to laboratory protocol.
No. Every reagent remains separate and each test is run independently.
Yes, on compatible open-system semi-automatic biochemistry analysers after appropriate programming and validation.
Yes, on compatible open-system fully automatic biochemistry analysers that permit third-party reagent programming and support the required wavelengths and assay modes.
No. GGT is not part of this core combo and can be sourced separately if required by the laboratory.
The combo contains SGOT, SGPT, Bilirubin Total & Direct, Alkaline Phosphatase, Total Protein and Albumin reagents.
The included reagents directly cover 7 commonly reported LFT parameters.
No. GGT is not included in this core LFT combo.
No. It can be calculated from:
Total Bilirubin − Direct Bilirubin
Yes. Where laboratory policy permits:
Globulin = Total Protein − Albumin
Yes:
A/G Ratio = Albumin ÷ Globulin
The individual reagents are Swemed Diagnostics products, while the LFT bundle itself is created by Microsidd India for procurement convenience.
340 nm.
405 nm.
546 nm.
Yes, on compatible open-system semi-automatic biochemistry analysers.
Yes, on compatible open-system fully automatic systems after reagent application programming and validation.
No. Each included reagent is a separate test system and must be run independently.
No. It is for professional in vitro diagnostic laboratory use only.
The information on this page is provided for product identification, laboratory procurement and professional educational purposes only.
The products included in this combo are intended for professional in vitro diagnostic use by trained laboratory personnel.
No individual LFT parameter should be interpreted in isolation to diagnose or exclude liver disease. Interpretation may require correlation between SGOT, SGPT, bilirubin fractions, ALP, albumin, total protein, clinical history, medications, imaging and other relevant investigations.
Each reagent included in this combo has its own specimen requirements, analyser settings, calibration, quality-control, storage and stability requirements.
For open-system fully automatic and semi-automatic analysers, instrument compatibility, reagent programming, calibration and analytical performance must be independently verified and validated by the laboratory before patient reporting.
The current Swemed package insert supplied with each actual reagent lot should always be treated as the definitive technical specification.
This product is non-returnable and non-exchangeable.
Please verify the brand, model, compatibility, pack size and product specifications before placing your order.
For laboratory reagents, customers should specifically verify the test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering.
For this LFT combo, customers should verify every individual reagent and pack configuration included in the bundle before placing the order.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
| Specification name | Specification Value |
|---|---|
| Chemical grade | Reagent, Laboratory |
| Color pattern | White |
| Product certifications & standards | CDSCO, ISO |
| Test method | Lab analysis |
| Test sample | Blood |