The Swemed Lipid Profile Reagent Combo Kit from Microsidd.com combines three commonly required clinical biochemistry reagents for routine lipid-profile testing into one convenient laboratory procurement bundle:
Total Cholesterol + Triglycerides + Direct HDL Cholesterol
Each component is an individual original Swemed Diagnostics professional IVD reagent. Microsidd India has grouped them into this combo to make lipid-profile reagent procurement easier for pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories.
Swemed lists Total Cholesterol using the CHOD/POD method, Triglycerides using the GPO-PAP method, and its Direct HDL product as a two-reagent direct enzymatic assay.
Important: This is a Microsidd-created procurement combo of separately packed Swemed reagents. It is not represented as a single factory-packed multiparameter kit manufactured by Swemed.
| Included Reagent | Brand | Method | Primary Application |
|---|---|---|---|
| Total Cholesterol Reagent | Swemed Diagnostics | CHOD/POD | Quantitative total cholesterol testing |
| Triglycerides Reagent | Swemed Diagnostics | GPO-PAP | Quantitative triglyceride testing |
| Direct HDL Cholesterol Reagent | Swemed Diagnostics | Direct Enzymatic | Quantitative HDL-C determination |
Swemed's current catalogue lists Cholesterol as a CHOD/POD reagent, while its biochemistry range lists Triglycerides as GPO-PAP. The Direct HDL technical insert describes a two-reagent enzymatic method intended for quantitative HDL cholesterol determination.
| Product | Available / Listed Pack |
|---|---|
| Total Cholesterol | 2 × 50 ml |
| Triglycerides | 50 ml / 2 × 50 ml |
| Direct HDL Cholesterol | 2 × 50 ml Direct Enzymatic Kit |
The Cholesterol 2 × 50 ml presentation is listed in Swemed's current catalogue. The Direct HDL configuration used for Microsidd's individual product listing is the 2 × 50 ml direct enzymatic reagent kit.
Instead of separately locating three different lipid-profile reagents, laboratories can procure the core lipid reagents together in one convenient product listing.
This makes the combo particularly useful for:
| Parameter | Included in Combo | Laboratory Role |
|---|---|---|
| Total Cholesterol | ✅ | Measures overall cholesterol concentration |
| Triglycerides | ✅ | Measures circulating triglycerides |
| HDL Cholesterol | ✅ | Measures high-density lipoprotein cholesterol |
| LDL Cholesterol | Not directly included | May be calculated or tested separately depending on laboratory protocol |
| VLDL | Not directly included | Commonly estimated from triglycerides where appropriate |
| Non-HDL Cholesterol | Calculated | Total Cholesterol − HDL Cholesterol |
This combo therefore provides the three fundamental measured parameters used in many routine lipid-profile workflows.
| Parameter | Total Cholesterol | Triglycerides | Direct HDL Cholesterol |
|---|---|---|---|
| Method | CHOD/POD | GPO-PAP | Direct Enzymatic |
| Assay Type | Endpoint | Endpoint | Endpoint |
| Wavelength | 505 nm | 505 nm | 630 nm |
| Sample | Serum / Plasma | Serum / Plasma | Serum / Plasma |
| Sample Volume | 10 µl | 10 µl | 10 µl |
| Standard / Calibrator | 200 mg/dL Standard | 200 mg/dL Standard | HDL Calibrator |
| Linearity | Up to 700 mg/dL | Up to 1000 mg/dL | Up to 180 mg/dL |
| Professional IVD | Yes | Yes | Yes |
Swemed's Direct HDL technical insert specifies 630 nm, endpoint mode, 10 µl sample, R1 800 µl + R2 200 µl and linearity up to 180 mg/dL.
The Swemed Total Cholesterol Reagent uses the established CHOD/POD enzymatic endpoint method for quantitative cholesterol determination.
| Specification | Details |
|---|---|
| Method | CHOD/POD |
| Wavelength | 505 nm |
| Sample Volume | 10 µl |
| Reagent Volume | 1000 µl |
| Standard | 200 mg/dL |
| Incubation | 10 minutes at 37°C |
| Linearity | Up to 700 mg/dL |
| Reagent | Ready to Use |
| Storage | 2–8°C |
Swemed's current catalogue confirms the CHOD/POD methodology and 2 × 50 ml pack presentation.
The Swemed Triglycerides Reagent uses the GPO-PAP enzymatic endpoint method.
| Specification | Details |
|---|---|
| Method | GPO-PAP |
| Wavelength | 505 nm |
| Sample Volume | 10 µl |
| Reagent Volume | 1000 µl |
| Standard | 200 mg/dL |
| Incubation | 15 min at room temperature or 10 min at 37°C |
| Linearity | Up to 1000 mg/dL |
| Reagent | Ready to Use |
| Application | Professional clinical chemistry |
Swemed lists Triglycerides as a GPO-PAP assay for serum/plasma in its biochemistry range.
The Swemed Direct HDL Cholesterol Reagent is a two-reagent direct enzymatic system.
The first reagent acts on non-HDL cholesterol, while the second reagent selectively solubilises HDL and produces colour for quantitative HDL-C determination.
| Specification | Details |
|---|---|
| Method | Direct Enzymatic |
| Mode | Endpoint |
| Wavelength | 630 nm |
| Temperature | 37°C |
| Sample Volume | 10 µl |
| Reagent R1 | 800 µl |
| Reagent R2 | 200 µl |
| Delay | 5 seconds |
| Linearity | Up to 180 mg/dL |
| Specimen | Serum / EDTA Plasma / Heparin Plasma |
| Storage | 2–8°C |
| Calibrator | Lyophilised human-serum calibrator |
Swemed recommends fresh serum, while EDTA and heparinised plasma are also acceptable; citrate-containing anticoagulants should not be used.
The reagents in this combo are suitable for compatible programmable open-system laboratory analysers, subject to appropriate application setup and laboratory validation.
The analyser should support relevant wavelengths including 505 nm and 630 nm.
Swemed's own Artos open-system chemistry analyser, for example, includes 505 nm and 630 nm filters among its available wavelengths.
Measures the overall circulating cholesterol concentration.
Measures triglycerides, an important circulating form of stored energy and a major component of routine lipid assessment.
Measures HDL-C, commonly referred to as the high-density lipoprotein fraction.
Together, these three measured parameters allow laboratories to build a routine lipid-profile workflow and, where clinically and mathematically appropriate, derive additional calculated lipid parameters.
| Step | Parameter |
|---|---|
| 1 | Measure Total Cholesterol |
| 2 | Measure Triglycerides |
| 3 | Measure HDL Cholesterol |
| 4 | Report measured values |
| 5 | Calculate additional lipid indices where laboratory protocol permits |
Calculated values must only be used according to the laboratory's validated formulas, clinical guidelines and applicable limitations.
| Buyer Type | Typical Use |
|---|---|
| Pathology Laboratories | Routine lipid profiles |
| Diagnostic Centres | Preventive and clinical lipid testing |
| Hospital Laboratories | Clinical chemistry |
| Cardiology Centres | Lipid assessment |
| Diabetes Clinics with Labs | Metabolic profile testing |
| Preventive Health Centres | Health-check packages |
| Clinical Chemistry Laboratories | Routine lipid testing |
| Medical Institutions | Teaching and diagnostic use |
| Corporate Health Labs | Screening programmes |
| Laboratory Distributors | Professional procurement |
Purchase the core lipid-profile reagents together instead of searching for three separate products.
A profile-oriented bundle makes it easier to procure the reagents required for routine cholesterol, triglyceride and HDL testing.
Useful when laboratories are starting lipid testing, replenishing routine stock or standardising their Swemed reagent portfolio.
All three included products are supplied under the Swemed Diagnostics brand.
The combo is created specifically for pathology laboratories, diagnostic centres, hospitals and institutional clinical chemistry procurement.
| Buying Reagents Individually | Microsidd Lipid Profile Combo |
|---|---|
| Search each reagent separately | Three core reagents in one listing |
| Higher chance of missing one parameter | Profile-oriented procurement |
| Separate product comparison | Technical summary in one page |
| Multiple purchasing decisions | Simplified purchasing workflow |
| Harder to view all methods together | Methods and wavelengths clearly compared |
| General marketplace listings may vary | Specialist diagnostic-product listing |
Microsidd India has long-standing experience in the IVD and diagnostic-products sector and focuses specifically on laboratory, diagnostic and healthcare procurement rather than operating as a general merchandise marketplace.
| Microsidd Advantage | Benefit for Laboratories |
|---|---|
| Diagnostic Product Specialisation | Better suited to professional reagent procurement |
| Profile-Based Combo | Easier lipid-profile purchasing |
| Original Individual Swemed Products | Clear brand identification |
| Technical Product Information | Methods and key specifications available before purchase |
| Open-System Guidance | Helps laboratories compare analyser requirements |
| GST Invoice | Available for eligible orders |
| Direct Seller Accountability | Purchase directly from Microsidd India |
| Bangalore-Based Operations | Convenient for Bengaluru and Karnataka laboratories |
| India-Wide Supply | Subject to stock and serviceability |
| Multi-Reagent Catalogue | Easier future replenishment of related reagents |
This Lipid Profile Combo is assembled as a commercial procurement bundle by Microsidd India.
The included products remain individually packed Swemed Diagnostics reagents in their original product packs.
The combo should not be interpreted as:
Each test must be performed individually according to its own Swemed instructions and laboratory-validated analyser application.
This product is relevant for searches such as:
| Entity | Details |
|---|---|
| Product | Lipid Profile Reagent Combo Kit |
| Brand | Swemed Diagnostics |
| Included Parameters | Total Cholesterol + Triglycerides + Direct HDL Cholesterol |
| Cholesterol Method | CHOD/POD |
| Triglycerides Method | GPO-PAP |
| HDL Method | Direct Enzymatic |
| Clinical Category | Lipid Profile |
| Product Category | Laboratory Reagent Combo |
| Application | Professional Clinical Chemistry |
| Compatibility | Compatible Open-System Fully & Semi-Automatic Analysers |
| Seller | Microsidd India |
| City | Bangalore / Bengaluru |
| State | Karnataka |
| Country | India |
| Website | microsidd.com |
It is a Microsidd-created laboratory procurement bundle containing individual Swemed Diagnostics reagents for:
Total Cholesterol + Triglycerides + Direct HDL Cholesterol.
No. The products remain separate Swemed reagents and each assay is performed independently.
They can be used on compatible open-system semi-automatic biochemistry analysers after programming and validation.
They can be used on compatible open-system fully automatic analysers that permit third-party reagent applications and support the required methods and wavelengths.
Yes. These are professional in vitro diagnostic reagents intended for trained laboratory personnel.
The combo is offered by Microsidd India through microsidd.com, subject to availability and delivery serviceability.
The combo contains Swemed reagents for Total Cholesterol, Triglycerides and Direct HDL Cholesterol.
No. This combo contains the three stated measured parameters. LDL may be tested separately or calculated where clinically appropriate and permitted by the laboratory protocol.
No. VLDL may be estimated using an appropriate validated calculation where applicable.
The individual reagents are Swemed products, but the profile-based commercial bundle is created by Microsidd India for procurement convenience.
CHOD/POD.
GPO-PAP.
A direct enzymatic two-reagent method.
Both are configured around 505 nm in their respective laboratory applications.
630 nm.
Serum is suitable across the panel. Depending on the individual assay, compatible plasma may also be used according to the respective manufacturer insert.
No. Cholesterol, Triglycerides and HDL are separate assays with separate reagents and application parameters.
Yes, with compatible open-system semi-automatic analysers after appropriate programming and validation.
Yes, with compatible open-system fully automatic analysers that support third-party reagent programming.
No. It is for professional in vitro diagnostic laboratory use only.
It can be ordered from Microsidd India through microsidd.com, subject to stock availability.
The information on this page is provided for product identification, laboratory procurement and professional educational purposes only.
The products included in this combo are intended for professional in vitro diagnostic use by trained laboratory personnel.
Lipid-profile results should not be interpreted independently to diagnose or exclude cardiovascular disease, dyslipidaemia, diabetes, metabolic disorders or other medical conditions.
Total Cholesterol, Triglycerides and HDL results should be interpreted according to current laboratory procedures, clinical guidelines, patient history and relevant medical assessment.
Each included reagent has different assay settings, calibration requirements, storage conditions and analyser programming requirements. Laboratories must follow the current Swemed package insert supplied with each individual reagent.
For open-system fully automatic and semi-automatic analysers, instrument compatibility, method programming, calibration, quality control and analytical performance must be verified and validated by the laboratory before patient reporting.
This product is non-returnable and non-exchangeable.
Please verify the brand, model, compatibility, pack size and product specifications before placing your order.
For laboratory reagents, customers should specifically verify the test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering.
As this product contains multiple laboratory reagents, customers should verify every reagent included in the combo before completing the order.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
| Specification name | Specification Value |
|---|---|
| Chemical grade | Reagent, Laboratory |
| Color pattern | White |
| Product certifications & standards | CDSCO, ISO |
| Test method | Lab analysis |
| Test sample | Blood |