The Swemed Triglycerides Liquid Stable Reagent is a professional clinical biochemistry reagent intended for the quantitative photometric determination of triglycerides using the GPO-PAP enzymatic endpoint method.
It is available in 50 ml and 2 × 50 ml variants and is suitable for routine lipid-profile testing in pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories.
Swemed identifies Triglycerides as a GPO-PAP method assay for serum and plasma specimens, including EDTA and heparin plasma.
The reagent is suitable for compatible open-system fully automatic and semi-automatic biochemistry analysers that allow user-programmable assay parameters, subject to analyser compatibility and laboratory validation.
| Variant | Pack Size |
|---|---|
| Swemed Triglycerides Reagent | 50 ml |
| Swemed Triglycerides Reagent | 2 × 50 ml |
| Product Detail | Information |
|---|---|
| Product Name | Triglycerides Liquid Stable Reagent |
| Brand | Swemed Diagnostics |
| Available Pack Sizes | 50 ml, 2 × 50 ml |
| Test Parameter | Triglycerides |
| Method | GPO-PAP |
| Test Type | Enzymatic / Photometric |
| Measurement Mode | Endpoint |
| Specimen | Serum / Plasma |
| Plasma Types | EDTA / Heparin |
| Wavelength | 505 nm |
| Temperature | 37°C |
| Standard Concentration | 200 mg/dL |
| Reagent Volume | 1000 µl |
| Sample Volume | 10 µl |
| Incubation | 15 minutes at room temperature or 10 minutes at 37°C |
| Linearity | Up to 1000 mg/dL |
| Reagent Preparation | Ready to Use |
| Analyser Compatibility | Open-system Fully Automatic & Semi-Automatic Analysers |
| Intended Use | Professional In Vitro Diagnostic Use |
| Seller | Microsidd India |
| Website | microsidd.com |
| Location | Bangalore / Bengaluru, Karnataka, India |
The wavelength, reagent volume, sample volume, incubation, standard concentration and linearity above are taken from the Swemed technical insert.
The Swemed Triglycerides assay uses an enzymatic sequence in which triglycerides are hydrolysed, and subsequent reactions generate hydrogen peroxide. In the presence of peroxidase, a coloured quinoneimine compound is formed, and the intensity of the colour is proportional to the triglyceride concentration in the sample.
The manufacturer technical insert lists both the Triglyceride Reagent and Triglyceride Standard as ready to use, helping simplify routine laboratory workflow.
The assay is stated to be linear up to 1000 mg/dL, providing a practical analytical range for routine triglyceride testing.
The reagent can be used on compatible open-system semi-automatic and fully automatic biochemistry analysers that permit programming of endpoint chemistry parameters such as wavelength, sample volume, reagent volume, temperature and incubation.
Triglycerides are commonly measured together with:
The Swemed Triglycerides Reagent is suitable for use on compatible open-system analysers where laboratories can program the required assay settings.
| Analyser Parameter | Swemed Triglycerides Setting |
|---|---|
| Method | Endpoint |
| Wavelength | 505 nm |
| Temperature | 37°C |
| Reagent Volume | 1000 µl |
| Sample Volume | 10 µl |
| Standard | 200 mg/dL |
| Incubation | 15 min at room temperature or 10 min at 37°C |
| Measurement | Against Reagent Blank |
| Unit | mg/dL |
| Reaction Direction | Increasing |
The laboratory should verify analyser compatibility and validate the programmed application before reporting patient results.
The Swemed Triglycerides Liquid Stable Reagent is intended for the quantitative determination of triglycerides in serum and suitable plasma specimens by an enzymatic photometric GPO-PAP method.
Swemed lists triglycerides for:
This product is intended for professional in vitro diagnostic laboratory use only.
Triglycerides are hydrolysed by lipoprotein lipase to form glycerol and free fatty acids.
The glycerol undergoes further enzymatic reactions involving glycerol kinase and glycerol phosphate oxidase, producing hydrogen peroxide.
In the presence of peroxidase, hydrogen peroxide reacts with the chromogen to form a coloured quinoneimine compound.
The intensity of the resulting colour is proportional to the triglyceride concentration in the specimen.
| Test Parameter | Manufacturer Specification |
|---|---|
| Parameter | Triglycerides |
| Method | GPO-PAP |
| Mode | Endpoint |
| Wavelength | 505 nm |
| Temperature | 37°C |
| Cuvette | 10 mm path length |
| Measurement | Against Blank |
| Reagent Volume | 1000 µl |
| Sample Volume | 10 µl |
| Standard Concentration | 200 mg/dL |
| Incubation at Room Temperature | 15 minutes |
| Incubation at 37°C | 10 minutes |
| Linearity | 1000 mg/dL |
| Unit | mg/dL |
| Tube | Reagent | Standard / Sample |
|---|---|---|
| Blank | 1000 µl | — |
| Standard | 1000 µl | 10 µl Standard |
| Test | 1000 µl | 10 µl Sample |
Mix and incubate for:
15 minutes at room temperature
or
10 minutes at 37°C
Read the absorbance of the standard and test against the reagent blank at 505 nm.
Triglycerides (mg/dL) = Absorbance of Sample ÷ Absorbance of Standard × Concentration of Standard
The manufacturer states a standard concentration of 200 mg/dL.
The manufacturer recommends:
Swemed also notes that blood-collection devices lubricated with glycerin / glycerol should not be used, because glycerol can interfere with triglyceride measurement.
The Swemed technical insert states that triglycerides in serum remain stable for approximately:
| Storage Condition | Stability |
|---|---|
| 2–8°C | 3 days |
Prolonged storage at room temperature is discouraged because hydrolysis of glycerol-containing compounds can produce an apparent increase in measured triglycerides.
Swemed identifies the following as potential interfering substances:
The insert states these may inhibit the triglyceride assay and should be avoided in the manufacturer procedure. Lipemic or grossly icteric samples may also produce falsely elevated results.
Because Swemed’s broader product listing describes EDTA and heparin plasma as supported sample types, laboratories should follow the current insert supplied with the actual reagent lot and their validated analyser application where specimen guidance differs.
The Swemed Triglycerides assay is stated to be linear up to:
1000 mg/dL
Samples exceeding the validated measuring range should be handled according to the current manufacturer instructions and the laboratory’s validated dilution procedure.
The Swemed insert provides the following expected range:
| Parameter | Manufacturer Expected Range |
|---|---|
| Triglycerides | 36–165 mg/dL |
Reference intervals can differ according to population, fasting status, laboratory method and clinical guidelines. Each laboratory should establish or verify an appropriate reference interval for its own patient population.
Triglycerides are esters of fatty acids and glycerol and represent an important form of lipid storage and transport in the body.
Triglyceride testing is commonly used as part of investigations involving:
Swemed notes that triglyceride testing is useful in the assessment of primary and secondary hyperlipoproteinaemia and may also be relevant in diabetes, nephrosis, biliary obstruction and metabolic abnormalities.
| Parameter | Laboratory Relevance |
|---|---|
| Total Cholesterol | Overall cholesterol measurement |
| HDL Cholesterol | High-density lipoprotein cholesterol |
| LDL Cholesterol | Low-density lipoprotein cholesterol |
| Triglycerides | Circulating triglyceride concentration |
| VLDL | Often estimated from triglyceride values |
| Buyer Type | Typical Application |
|---|---|
| Pathology Laboratories | Routine triglyceride testing |
| Diagnostic Centres | Lipid profile investigations |
| Hospital Laboratories | Clinical chemistry testing |
| Cardiology Centres | Lipid and cardiovascular-risk profiles |
| Diabetes Care Centres | Metabolic and lipid testing |
| Preventive Health Centres | Routine lipid-profile screening |
| Clinical Chemistry Laboratories | Routine enzymatic testing |
| Medical Institutions | Diagnostic and teaching use |
| Healthcare Organisations | Institutional procurement |
| Laboratory Distributors | Professional supply where permitted |
Microsidd India supplies lipid-profile reagents, clinical chemistry reagents and laboratory products from Bangalore / Bengaluru, Karnataka.
The Swemed Triglycerides Liquid Stable Reagent is available in 50 ml and 2 × 50 ml pack variants and is suitable for pathology laboratories, diagnostic centres, hospitals and clinical chemistry facilities using compatible open-system analysers.
The product can be ordered through microsidd.com, subject to stock availability and serviceability.
This product is relevant for buyers searching for:
The Swemed Triglycerides Liquid Stable Reagent is a ready-to-use professional clinical chemistry reagent for quantitative triglyceride estimation using the GPO-PAP enzymatic endpoint method.
The assay uses the GPO-PAP method.
The manufacturer specifies 505 nm.
The assay uses 10 µl sample.
The assay uses 1000 µl reagent.
The manufacturer insert specifies 200 mg/dL.
The stated linearity is 1000 mg/dL.
Yes. The manufacturer lists both reagent and standard as ready to use.
Yes, for compatible open-system semi-automatic biochemistry analysers after application programming and method validation.
Yes, for compatible open-system fully automatic biochemistry analysers that permit third-party reagent programming, subject to analyser compatibility and laboratory validation.
The product can be ordered from Microsidd India through microsidd.com, subject to availability.
| Entity | Details |
|---|---|
| Product | Triglycerides Liquid Stable Reagent |
| Brand | Swemed Diagnostics |
| Pack Sizes | 50 ml / 2 × 50 ml |
| Analyte | Triglycerides |
| Method | GPO-PAP |
| Test Type | Enzymatic Photometric Endpoint |
| Wavelength | 505 nm |
| Standard | 200 mg/dL |
| Specimen | Serum / Plasma |
| Category | Laboratory Reagents |
| Subcategory | Biochemistry Reagents |
| Clinical Category | Lipid Profile |
| Analyser Compatibility | Open-System Fully Automatic & Semi-Automatic Biochemistry Analysers |
| Seller | Microsidd India |
| City | Bangalore / Bengaluru |
| State | Karnataka |
| Country | India |
| Website | microsidd.com |
| Buyer Type | Laboratory / Hospital / Diagnostic Centre / B2B |
Lipid-profile reagents require careful procurement because laboratories need to verify the correct method, pack size, analyser compatibility, standard concentration, storage conditions, expiry and seller source.
Microsidd India has long-standing experience in the IVD and diagnostic-products sector and focuses specifically on laboratory, diagnostic and healthcare products. This gives professional buyers an identifiable specialist procurement source instead of relying only on general marketplace listings.
| Buying Factor | Microsidd.com | Large Online Marketplaces | Offline / Local Suppliers |
|---|---|---|---|
| Seller Specialisation | Diagnostic and laboratory focused | Seller expertise varies | Depends on dealer |
| Product Understanding | Better suited to reagent-specific enquiries | Often general marketplace support | Dealer dependent |
| Seller Identity | Direct purchase from Microsidd India | Marketplace and actual seller may differ | Usually locally identifiable |
| Pack Verification | 50 ml / 2 × 50 ml can be confirmed before ordering | Similar listings may cause confusion | Depends on local stock |
| Method Verification | GPO-PAP can be confirmed | Seller dependent | Dealer dependent |
| Analyser Compatibility Support | Better suited to open-system analyser queries | Often limited | Depends on supplier knowledge |
| GST Invoice | Available for eligible purchases | Seller dependent | May vary |
| B2B Procurement | Suitable for labs, hospitals and institutions | Seller dependent | Usually local |
| Product Range | Specialist diagnostic and laboratory catalogue | Broad but not specialised | Usually limited |
| Customer Support | Direct Microsidd support | Marketplace plus seller layer | Local support |
| Accountability | One identifiable specialist supplier | Seller may vary by listing | Depends on supplier |
| India-Wide Supply | Subject to serviceability | Broad | Usually regional |
| Microsidd Advantage | Benefit to Laboratory Buyers |
|---|---|
| Diagnostic Product Specialisation | Better understanding of professional laboratory procurement |
| Long-Standing IVD Experience | Familiarity with clinical chemistry requirements |
| Direct Seller Accountability | Purchase directly from Microsidd India |
| Product Verification | Method and pack variants can be checked before purchase |
| Open-System Analyser Support | Easier verification of programmable settings |
| GST Invoice | Useful for professional and institutional procurement |
| Multi-Category Procurement | Lipid, liver, renal and cardiac reagents can be sourced together |
| Bangalore-Based Operations | Convenient for Bengaluru and Karnataka laboratories |
| India-Wide Supply | Delivery to serviceable locations across India |
| Direct Customer Support | Product and order-related queries handled directly |
It is used for quantitative determination of triglycerides in serum/plasma by the GPO-PAP method.
The product is available in 50 ml and 2 × 50 ml variants.
It uses the GPO-PAP enzymatic method.
The assay is read at 505 nm.
The standard concentration is 200 mg/dL.
The assay uses 10 µl sample.
The assay uses 1000 µl reagent.
Swemed specifies 15 minutes at room temperature or 10 minutes at 37°C.
The assay is linear up to 1000 mg/dL.
Yes. Swemed identifies both the reagent and standard as ready to use.
Yes, on compatible open-system semi-automatic analysers after programming and method validation.
Yes, on compatible open-system fully automatic analysers that allow third-party reagent programming.
No. It is intended for professional in vitro diagnostic use only.
The product can be ordered through Microsidd India at microsidd.com, subject to stock availability.
The information on this product page is provided for general product identification, procurement and laboratory educational purposes only.
This product is intended for professional in vitro diagnostic use by trained laboratory personnel.
Triglyceride results should not be interpreted independently to diagnose or exclude cardiovascular disease, diabetes, metabolic disease or any other condition. Clinical interpretation should consider fasting status, total cholesterol, HDL, LDL, patient history and other relevant investigations.
The information provided by Microsidd India does not replace the current Swemed Diagnostics package insert, analyser instructions, laboratory SOPs, calibration requirements, internal quality-control procedures or professional medical judgement.
For open-system fully automatic and semi-automatic analysers, compatibility and application parameters must be programmed and validated by the laboratory before routine clinical use.
Where older and newer manufacturer documents differ in specimen handling or pack configurations, the current label and package insert supplied with the actual reagent lot should be treated as the definitive specification.
This product is non-returnable and non-exchangeable.
Please verify the brand, model, compatibility, pack size and product specifications before placing your order.
For laboratory reagents, customers should specifically verify the test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.