Swemed Diagnostics

Triglycerides Liquid Stable Reagent – 50 ml & 2 × 50 ml | GPO-PAP Method

Regular price Rs. 1,800.00
Tax included. Shipping calculated at checkout.
SKU: TGL 50ml
Pack Size: 50ml
No Return / No Exchange
This product is non-returnable and non-exchangeable.
View policy details

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Pairs well with

Swemed Triglycerides Reagent 50ml & 2x50ml GPO-PAP Microsidd
Rs. 1,800.00
50ml
Subscribe and save

Auto-renews, skip or cancel anytime.

To add to cart, go to the product page and select a purchase option

Swemed Triglycerides Liquid Stable Reagent

The Swemed Triglycerides Liquid Stable Reagent is a professional clinical biochemistry reagent intended for the quantitative photometric determination of triglycerides using the GPO-PAP enzymatic endpoint method.

It is available in 50 ml and 2 × 50 ml variants and is suitable for routine lipid-profile testing in pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories.

Swemed identifies Triglycerides as a GPO-PAP method assay for serum and plasma specimens, including EDTA and heparin plasma.

The reagent is suitable for compatible open-system fully automatic and semi-automatic biochemistry analysers that allow user-programmable assay parameters, subject to analyser compatibility and laboratory validation.


Available Pack Sizes

Variant Pack Size
Swemed Triglycerides Reagent 50 ml
Swemed Triglycerides Reagent 2 × 50 ml

Product at a Glance

Product Detail Information
Product Name Triglycerides Liquid Stable Reagent
Brand Swemed Diagnostics
Available Pack Sizes 50 ml, 2 × 50 ml
Test Parameter Triglycerides
Method GPO-PAP
Test Type Enzymatic / Photometric
Measurement Mode Endpoint
Specimen Serum / Plasma
Plasma Types EDTA / Heparin
Wavelength 505 nm
Temperature 37°C
Standard Concentration 200 mg/dL
Reagent Volume 1000 µl
Sample Volume 10 µl
Incubation 15 minutes at room temperature or 10 minutes at 37°C
Linearity Up to 1000 mg/dL
Reagent Preparation Ready to Use
Analyser Compatibility Open-system Fully Automatic & Semi-Automatic Analysers
Intended Use Professional In Vitro Diagnostic Use
Seller Microsidd India
Website microsidd.com
Location Bangalore / Bengaluru, Karnataka, India

The wavelength, reagent volume, sample volume, incubation, standard concentration and linearity above are taken from the Swemed technical insert.


Key Features

  • Swemed Diagnostics Triglycerides Reagent
  • Available in 50 ml and 2 × 50 ml
  • GPO-PAP enzymatic method
  • Ready-to-use reagent
  • Ready-to-use triglyceride standard
  • Endpoint photometric assay
  • Recommended wavelength: 505 nm
  • Standard concentration: 200 mg/dL
  • Sample volume: 10 µl
  • Reagent volume: 1000 µl
  • Linearity up to 1000 mg/dL
  • Suitable for serum and compatible plasma samples
  • Suitable for lipid-profile testing
  • Suitable for compatible open-system fully automatic analysers
  • Suitable for compatible open-system semi-automatic analysers
  • For professional in vitro diagnostic use only

Key Benefits

GPO-PAP Enzymatic Method

The Swemed Triglycerides assay uses an enzymatic sequence in which triglycerides are hydrolysed, and subsequent reactions generate hydrogen peroxide. In the presence of peroxidase, a coloured quinoneimine compound is formed, and the intensity of the colour is proportional to the triglyceride concentration in the sample.

Ready-to-Use Reagent System

The manufacturer technical insert lists both the Triglyceride Reagent and Triglyceride Standard as ready to use, helping simplify routine laboratory workflow.

High Linearity

The assay is stated to be linear up to 1000 mg/dL, providing a practical analytical range for routine triglyceride testing.

Open-System Analyser Compatibility

The reagent can be used on compatible open-system semi-automatic and fully automatic biochemistry analysers that permit programming of endpoint chemistry parameters such as wavelength, sample volume, reagent volume, temperature and incubation.

Useful for Routine Lipid Profiles

Triglycerides are commonly measured together with:

  • Total Cholesterol
  • HDL Cholesterol
  • LDL Cholesterol
  • VLDL estimation
  • Other lipid-related parameters

Compatible with Open-System Biochemistry Analysers

The Swemed Triglycerides Reagent is suitable for use on compatible open-system analysers where laboratories can program the required assay settings.

Analyser Parameter Swemed Triglycerides Setting
Method Endpoint
Wavelength 505 nm
Temperature 37°C
Reagent Volume 1000 µl
Sample Volume 10 µl
Standard 200 mg/dL
Incubation 15 min at room temperature or 10 min at 37°C
Measurement Against Reagent Blank
Unit mg/dL
Reaction Direction Increasing

The laboratory should verify analyser compatibility and validate the programmed application before reporting patient results.


Intended Use

The Swemed Triglycerides Liquid Stable Reagent is intended for the quantitative determination of triglycerides in serum and suitable plasma specimens by an enzymatic photometric GPO-PAP method.

Swemed lists triglycerides for:

  • Serum
  • Plasma
  • EDTA plasma
  • Heparin plasma

This product is intended for professional in vitro diagnostic laboratory use only.


Test Principle

Triglycerides are hydrolysed by lipoprotein lipase to form glycerol and free fatty acids.

The glycerol undergoes further enzymatic reactions involving glycerol kinase and glycerol phosphate oxidase, producing hydrogen peroxide.

In the presence of peroxidase, hydrogen peroxide reacts with the chromogen to form a coloured quinoneimine compound.

The intensity of the resulting colour is proportional to the triglyceride concentration in the specimen.


Technical Specifications

Test Parameter Manufacturer Specification
Parameter Triglycerides
Method GPO-PAP
Mode Endpoint
Wavelength 505 nm
Temperature 37°C
Cuvette 10 mm path length
Measurement Against Blank
Reagent Volume 1000 µl
Sample Volume 10 µl
Standard Concentration 200 mg/dL
Incubation at Room Temperature 15 minutes
Incubation at 37°C 10 minutes
Linearity 1000 mg/dL
Unit mg/dL

 


Assay Procedure Summary

Tube Reagent Standard / Sample
Blank 1000 µl
Standard 1000 µl 10 µl Standard
Test 1000 µl 10 µl Sample

Mix and incubate for:

15 minutes at room temperature

or

10 minutes at 37°C

Read the absorbance of the standard and test against the reagent blank at 505 nm.


Calculation

Triglycerides (mg/dL) = Absorbance of Sample ÷ Absorbance of Standard × Concentration of Standard

The manufacturer states a standard concentration of 200 mg/dL.


Specimen Requirements

The manufacturer recommends:

  • Fresh specimen
  • Clear sample
  • Non-haemolysed serum
  • Fasting patient sample where clinically appropriate

Swemed also notes that blood-collection devices lubricated with glycerin / glycerol should not be used, because glycerol can interfere with triglyceride measurement.


Specimen Stability

The Swemed technical insert states that triglycerides in serum remain stable for approximately:

Storage Condition Stability
2–8°C 3 days

Prolonged storage at room temperature is discouraged because hydrolysis of glycerol-containing compounds can produce an apparent increase in measured triglycerides.


Interfering Substances

Swemed identifies the following as potential interfering substances:

  • Heparin
  • EDTA
  • Fluoride
  • Oxalate
  • Citrate

The insert states these may inhibit the triglyceride assay and should be avoided in the manufacturer procedure. Lipemic or grossly icteric samples may also produce falsely elevated results.

Because Swemed’s broader product listing describes EDTA and heparin plasma as supported sample types, laboratories should follow the current insert supplied with the actual reagent lot and their validated analyser application where specimen guidance differs.


Measuring Range and Linearity

The Swemed Triglycerides assay is stated to be linear up to:

1000 mg/dL

Samples exceeding the validated measuring range should be handled according to the current manufacturer instructions and the laboratory’s validated dilution procedure.


Manufacturer Expected Values

The Swemed insert provides the following expected range:

Parameter Manufacturer Expected Range
Triglycerides 36–165 mg/dL

Reference intervals can differ according to population, fasting status, laboratory method and clinical guidelines. Each laboratory should establish or verify an appropriate reference interval for its own patient population.


Why Triglycerides Testing Is Important

Triglycerides are esters of fatty acids and glycerol and represent an important form of lipid storage and transport in the body.

Triglyceride testing is commonly used as part of investigations involving:

  • Lipid-profile evaluation
  • Hypertriglyceridaemia
  • Dyslipidaemia
  • Cardiovascular-risk assessment
  • Diabetes mellitus
  • Metabolic disorders
  • Endocrine disturbances
  • Nephrotic conditions
  • Follow-up of lipid-management programmes

Swemed notes that triglyceride testing is useful in the assessment of primary and secondary hyperlipoproteinaemia and may also be relevant in diabetes, nephrosis, biliary obstruction and metabolic abnormalities.


Triglycerides in a Lipid Profile

Parameter Laboratory Relevance
Total Cholesterol Overall cholesterol measurement
HDL Cholesterol High-density lipoprotein cholesterol
LDL Cholesterol Low-density lipoprotein cholesterol
Triglycerides Circulating triglyceride concentration
VLDL Often estimated from triglyceride values

Who Can Buy This Product?

Buyer Type Typical Application
Pathology Laboratories Routine triglyceride testing
Diagnostic Centres Lipid profile investigations
Hospital Laboratories Clinical chemistry testing
Cardiology Centres Lipid and cardiovascular-risk profiles
Diabetes Care Centres Metabolic and lipid testing
Preventive Health Centres Routine lipid-profile screening
Clinical Chemistry Laboratories Routine enzymatic testing
Medical Institutions Diagnostic and teaching use
Healthcare Organisations Institutional procurement
Laboratory Distributors Professional supply where permitted

Useful Tips Before Ordering

  • Confirm that Triglycerides – GPO-PAP Method is required.
  • Choose the correct pack: 50 ml or 2 × 50 ml.
  • Confirm your analyser is an open system before programming third-party reagents.
  • Ensure the analyser supports 505 nm endpoint measurement.
  • Confirm 1000 µl reagent and 10 µl sample programming.
  • Verify the standard concentration: 200 mg/dL.
  • Follow current manufacturer instructions for sample type.
  • Use fresh and properly handled specimens.
  • Avoid glycerol-contaminated sample-collection equipment.
  • Perform calibration and internal quality control before routine use.
  • Verify analyser application and method performance before reporting patient results.

Buy Swemed Triglycerides Reagent in Bangalore

Microsidd India supplies lipid-profile reagents, clinical chemistry reagents and laboratory products from Bangalore / Bengaluru, Karnataka.

The Swemed Triglycerides Liquid Stable Reagent is available in 50 ml and 2 × 50 ml pack variants and is suitable for pathology laboratories, diagnostic centres, hospitals and clinical chemistry facilities using compatible open-system analysers.

The product can be ordered through microsidd.com, subject to stock availability and serviceability.


Search Relevance

This product is relevant for buyers searching for:

  • Triglycerides reagent supplier in Bangalore
  • Swemed Triglycerides Reagent Bangalore
  • Triglycerides GPO PAP reagent Bengaluru
  • Triglyceride reagent 50 ml
  • Triglycerides reagent 2 × 50 ml
  • Lipid profile reagent supplier Bangalore
  • Triglyceride reagent for semi auto analyser
  • Triglycerides reagent for fully automatic analyser
  • Open system biochemistry reagent Bangalore
  • Clinical chemistry reagent supplier near me
  • Pathology lab reagent supplier Bangalore
  • Swemed Triglycerides reagent online India

Product Summary

What is Swemed Triglycerides Liquid Stable Reagent?

The Swemed Triglycerides Liquid Stable Reagent is a ready-to-use professional clinical chemistry reagent for quantitative triglyceride estimation using the GPO-PAP enzymatic endpoint method.

Which pack sizes are available?

  • 50 ml
  • 2 × 50 ml

Which method is used?

The assay uses the GPO-PAP method.

What wavelength is required?

The manufacturer specifies 505 nm.

What is the sample volume?

The assay uses 10 µl sample.

What is the reagent volume?

The assay uses 1000 µl reagent.

What is the triglyceride standard concentration?

The manufacturer insert specifies 200 mg/dL.

What is the linearity?

The stated linearity is 1000 mg/dL.

Is the reagent ready to use?

Yes. The manufacturer lists both reagent and standard as ready to use.

Is it suitable for semi-automatic analysers?

Yes, for compatible open-system semi-automatic biochemistry analysers after application programming and method validation.

Is it suitable for fully automatic analysers?

Yes, for compatible open-system fully automatic biochemistry analysers that permit third-party reagent programming, subject to analyser compatibility and laboratory validation.

Where can it be purchased?

The product can be ordered from Microsidd India through microsidd.com, subject to availability.


Entity Information

Entity Details
Product Triglycerides Liquid Stable Reagent
Brand Swemed Diagnostics
Pack Sizes 50 ml / 2 × 50 ml
Analyte Triglycerides
Method GPO-PAP
Test Type Enzymatic Photometric Endpoint
Wavelength 505 nm
Standard 200 mg/dL
Specimen Serum / Plasma
Category Laboratory Reagents
Subcategory Biochemistry Reagents
Clinical Category Lipid Profile
Analyser Compatibility Open-System Fully Automatic & Semi-Automatic Biochemistry Analysers
Seller Microsidd India
City Bangalore / Bengaluru
State Karnataka
Country India
Website microsidd.com
Buyer Type Laboratory / Hospital / Diagnostic Centre / B2B

Why Buy Swemed Triglycerides Reagent from Microsidd.com?

Lipid-profile reagents require careful procurement because laboratories need to verify the correct method, pack size, analyser compatibility, standard concentration, storage conditions, expiry and seller source.

Microsidd India has long-standing experience in the IVD and diagnostic-products sector and focuses specifically on laboratory, diagnostic and healthcare products. This gives professional buyers an identifiable specialist procurement source instead of relying only on general marketplace listings.

Microsidd.com vs Online Marketplaces vs Offline Suppliers

Buying Factor Microsidd.com Large Online Marketplaces Offline / Local Suppliers
Seller Specialisation Diagnostic and laboratory focused Seller expertise varies Depends on dealer
Product Understanding Better suited to reagent-specific enquiries Often general marketplace support Dealer dependent
Seller Identity Direct purchase from Microsidd India Marketplace and actual seller may differ Usually locally identifiable
Pack Verification 50 ml / 2 × 50 ml can be confirmed before ordering Similar listings may cause confusion Depends on local stock
Method Verification GPO-PAP can be confirmed Seller dependent Dealer dependent
Analyser Compatibility Support Better suited to open-system analyser queries Often limited Depends on supplier knowledge
GST Invoice Available for eligible purchases Seller dependent May vary
B2B Procurement Suitable for labs, hospitals and institutions Seller dependent Usually local
Product Range Specialist diagnostic and laboratory catalogue Broad but not specialised Usually limited
Customer Support Direct Microsidd support Marketplace plus seller layer Local support
Accountability One identifiable specialist supplier Seller may vary by listing Depends on supplier
India-Wide Supply Subject to serviceability Broad Usually regional

Benefits of Buying from Microsidd.com

Microsidd Advantage Benefit to Laboratory Buyers
Diagnostic Product Specialisation Better understanding of professional laboratory procurement
Long-Standing IVD Experience Familiarity with clinical chemistry requirements
Direct Seller Accountability Purchase directly from Microsidd India
Product Verification Method and pack variants can be checked before purchase
Open-System Analyser Support Easier verification of programmable settings
GST Invoice Useful for professional and institutional procurement
Multi-Category Procurement Lipid, liver, renal and cardiac reagents can be sourced together
Bangalore-Based Operations Convenient for Bengaluru and Karnataka laboratories
India-Wide Supply Delivery to serviceable locations across India
Direct Customer Support Product and order-related queries handled directly

Frequently Asked Questions

What is Swemed Triglycerides Reagent used for?

It is used for quantitative determination of triglycerides in serum/plasma by the GPO-PAP method.

What pack sizes are available?

The product is available in 50 ml and 2 × 50 ml variants.

What method does the reagent use?

It uses the GPO-PAP enzymatic method.

What wavelength is used?

The assay is read at 505 nm.

What is the standard concentration?

The standard concentration is 200 mg/dL.

What is the sample volume?

The assay uses 10 µl sample.

What is the reagent volume?

The assay uses 1000 µl reagent.

What is the incubation time?

Swemed specifies 15 minutes at room temperature or 10 minutes at 37°C.

What is the linearity?

The assay is linear up to 1000 mg/dL.

Is the reagent ready to use?

Yes. Swemed identifies both the reagent and standard as ready to use.

Can it be used on semi-automatic biochemistry analysers?

Yes, on compatible open-system semi-automatic analysers after programming and method validation.

Can it be used on fully automatic biochemistry analysers?

Yes, on compatible open-system fully automatic analysers that allow third-party reagent programming.

Is this product for home testing?

No. It is intended for professional in vitro diagnostic use only.

Where can I buy Swemed Triglycerides Reagent in Bangalore?

The product can be ordered through Microsidd India at microsidd.com, subject to stock availability.

Medical and Laboratory Disclaimer

The information on this product page is provided for general product identification, procurement and laboratory educational purposes only.

This product is intended for professional in vitro diagnostic use by trained laboratory personnel.

Triglyceride results should not be interpreted independently to diagnose or exclude cardiovascular disease, diabetes, metabolic disease or any other condition. Clinical interpretation should consider fasting status, total cholesterol, HDL, LDL, patient history and other relevant investigations.

The information provided by Microsidd India does not replace the current Swemed Diagnostics package insert, analyser instructions, laboratory SOPs, calibration requirements, internal quality-control procedures or professional medical judgement.

For open-system fully automatic and semi-automatic analysers, compatibility and application parameters must be programmed and validated by the laboratory before routine clinical use.

Where older and newer manufacturer documents differ in specimen handling or pack configurations, the current label and package insert supplied with the actual reagent lot should be treated as the definitive specification.

No Return / No Exchange Policy

This product is non-returnable and non-exchangeable.

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

For laboratory reagents, customers should specifically verify the test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Didn't find the product you were looking for?