Swemed Diagnostics

HDL Cholesterol Direct Enzymatic Liquid Reagent Kit 100ml

Regular price Rs. 1,200.00
Tax included. Shipping calculated at checkout.
SKU: HDLC 100ml
No Return / No Exchange
This product is non-returnable and non-exchangeable.
View policy details

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Pairs well with

HDL Cholesterol Direct Enzymatic Liquid Reagent Kit 100ml
Rs. 1,200.00
Subscribe and save

Auto-renews, skip or cancel anytime.

To add to cart, go to the product page and select a purchase option

Swemed HDL Cholesterol Direct Enzymatic Liquid Reagent Kit 100ml

The Swemed HDL Cholesterol Reagent Kit is a professional direct enzymatic liquid biochemistry reagent intended for the quantitative determination of HDL Cholesterol (HDL-C) in serum and plasma.

The assay uses a two-reagent direct enzymatic method designed to selectively measure HDL cholesterol without requiring a separate precipitation step. It is intended for use in pathology laboratories, diagnostic centres, hospitals and clinical biochemistry laboratories performing routine lipid profile testing.

HDL cholesterol is an important component of lipid-profile assessment. High-density lipoproteins participate in cholesterol transport, and HDL-C measurement is commonly used together with total cholesterol, triglycerides and LDL cholesterol in cardiovascular-risk evaluation.


Product at a Glance

Product Detail Information
Product Name HDL Cholesterol Reagent Kit
Brand Swemed Diagnostics
Reagent Type Direct Enzymatic Liquid
Test Parameter HDL Cholesterol / HDL-C
Assay Format Two-Reagent System
Test Type Direct Enzymatic / Photometric
Measurement Mode Endpoint
Reaction Direction Increasing
Specimen Serum, EDTA Plasma, Heparin Plasma
Wavelength 630 nm
Reaction Temperature 37°C
Manual Incubation 10 minutes at room temperature
Sample Volume 10 µl
Reagent 1 Volume 800 µl
Reagent 2 Volume 200 µl
Linearity Up to 180 mg/dL
Reagent Preparation Ready to Use
Calibrator Lyophilized Human Serum
Storage 2–8°C
Intended Use Professional In Vitro Diagnostic Use
Seller Microsidd India
Website microsidd.com
Location Bangalore / Bengaluru, Karnataka, India

 


Kit Components

The Swemed Direct HDL Cholesterol system consists of:

Component Description
Reagent 1 Enzyme Reagent
Reagent 2 Developer Reagent
Calibrator Lyophilized Human Serum

The reagents are supplied ready to use. The calibrator is reconstituted with the exact volume of deionized water stated on its label, mixed thoroughly and allowed to stand at room temperature for approximately 30 minutes before use.


Key Features

  • Swemed Diagnostics HDL Cholesterol Reagent
  • Direct enzymatic liquid method
  • Designed for quantitative HDL-C determination
  • Two-reagent assay format
  • No separate precipitation step required
  • Suitable for serum and plasma
  • Compatible with serum, EDTA plasma and heparin plasma
  • Reagents supplied ready to use
  • Endpoint measurement
  • Wavelength: 630 nm
  • Sample requirement: 10 µl
  • Linearity up to 180 mg/dL
  • Suitable for routine lipid-profile testing
  • Professional in vitro diagnostic use only
  • Suitable for pathology labs, hospitals and diagnostic centres

Key Benefits

Direct HDL Cholesterol Measurement

The assay uses selective detergent chemistry and enzymatic reactions to enable direct determination of HDL cholesterol without a manual lipoprotein precipitation procedure.

Ready-to-Use Reagents

Reagent 1 and Reagent 2 are supplied ready for laboratory use, helping simplify routine HDL testing workflows.

Low Sample Volume

The assay uses only 10 µl of sample, making it suitable for routine clinical chemistry workflows where efficient specimen utilisation is important.

Suitable for Routine Lipid Profiles

HDL-C is commonly measured together with:

  • Total Cholesterol
  • Triglycerides
  • LDL Cholesterol
  • VLDL calculations or related lipid parameters

This makes the reagent highly relevant for laboratories performing routine lipid-profile investigations.

Broad Laboratory Application

Suitable for pathology laboratories, hospital laboratories, diagnostic centres and other professional clinical chemistry facilities.


Intended Use

The Swemed HDL Cholesterol Direct Enzymatic Liquid Reagent is intended for quantitative determination of HDL cholesterol in serum and plasma.

The product is intended for use by trained laboratory professionals and for in vitro diagnostic use only.


Test Principle

The method uses a two-reagent system based on selective detergent and enzymatic reactions.

In the first reagent, non-HDL unesterified cholesterol undergoes an enzyme reaction. The hydrogen peroxide produced during this stage is consumed through a peroxidase reaction, yielding a colourless product.

The second reagent contains a detergent that selectively solubilizes HDL, together with cholesterol esterase and a chromogenic coupler. This produces a coloured reaction proportional to the HDL cholesterol concentration present in the specimen.


Technical Specifications

Test Parameter Manufacturer Specification
Parameter HDL Cholesterol
Method Direct Enzymatic
Assay Format Two Reagents
Mode Endpoint
Wavelength 630 nm
Reaction Temperature 37°C
Reaction Direction Increasing
Sample Volume 10 µl
Reagent 1 Volume 800 µl
Reagent 2 Volume 200 µl
Delay 5 seconds
Manual Incubation 10 minutes at room temperature
Linearity 180 mg/dL

 


Manual Assay Procedure

Addition Blank Calibrator Test
HDL Reagent 1 800 µl 800 µl 800 µl
HDL Reagent 2 200 µl 200 µl 200 µl
Calibrator 10 µl
Sample 10 µl

Mix and incubate for 10 minutes at room temperature, then measure the absorbance of the sample and calibrator against the reagent blank at 630 nm.


Specimen Requirements

Suitable specimens include:

  • Fresh serum
  • EDTA plasma
  • Heparinized plasma

Fresh serum is recommended. Serum should be removed from the blood clot as soon as possible.

Citrate-containing anticoagulants should not be used.


Specimen Stability

The manufacturer states that samples are stable for approximately:

Storage Condition Stability
2–8°C 7 days

 


Measuring Range and Linearity

The Swemed Direct HDL Cholesterol method is linear up to 180 mg/dL.

Samples with concentrations above this limit may be diluted 1:1, with the resulting value multiplied by 2 according to the manufacturer procedure.


Reagent Storage and Stability

Store the HDL Cholesterol reagents at:

2–8°C

When stored correctly, the reagents remain stable until the expiration date stated on the reagent bottle and kit-box label.


Why HDL Cholesterol Testing Is Important

HDL cholesterol is one of the major lipoprotein-related parameters used in clinical lipid assessment.

HDL particles participate in the transport of cholesterol in the bloodstream. HDL-C measurement is commonly used as part of cardiovascular risk assessment and lipid-profile interpretation. The Swemed insert describes HDL cholesterol measurement as a useful predictor in coronary heart disease evaluation.

HDL-C testing may therefore form part of:

  • Routine lipid profiles
  • Cardiovascular-risk assessment
  • Dyslipidaemia investigation
  • Metabolic-health evaluation
  • Diabetes-related lipid monitoring
  • Preventive health screening
  • Follow-up of lipid-management programmes

Individual results should always be interpreted by qualified healthcare professionals in conjunction with other lipid parameters and the patient's clinical information.


HDL Cholesterol in a Lipid Profile

Parameter Laboratory Relevance
Total Cholesterol Measures overall circulating cholesterol
HDL Cholesterol Measures cholesterol associated with high-density lipoproteins
LDL Cholesterol Commonly used in atherogenic-risk evaluation
Triglycerides Measures circulating triglyceride concentration
VLDL Often estimated as part of lipid-profile interpretation

Who Can Buy This Product?

Buyer Type Typical Application
Pathology Laboratories Routine HDL-C and lipid-profile testing
Diagnostic Centres Cardiovascular and metabolic investigations
Hospital Laboratories Clinical chemistry and lipid testing
Clinics with Laboratory Facilities Routine biochemical screening
Preventive Health Centres Lipid-profile investigations
Medical Institutions Laboratory and teaching applications
Healthcare Organisations Professional diagnostic procurement
Laboratory Distributors Professional supply where permitted
Clinical Chemistry Laboratories Routine HDL cholesterol testing

Useful Tips Before Ordering

  • Verify that Direct HDL Cholesterol is the required test parameter.
  • Confirm compatibility with your biochemistry analyser.
  • Verify the required 630 nm wavelength capability.
  • Confirm that the laboratory workflow supports a two-reagent HDL assay.
  • Ensure the required calibrator is supplied or available.
  • Verify storage facilities at 2–8°C.
  • Use fresh serum or approved plasma specimens.
  • Do not use citrate plasma.
  • Follow the current Swemed assay instructions.
  • Maintain routine calibration and internal quality control.
  • Do not use reagent after the stated expiry date.

Buy Swemed HDL Cholesterol Reagent in Bangalore

Microsidd India supplies biochemistry reagents, lipid-profile reagents and clinical laboratory products from Bangalore / Bengaluru, Karnataka.

The Swemed HDL Cholesterol Direct Enzymatic reagent is suitable for procurement by:

  • Pathology laboratories in Bangalore
  • Diagnostic centres in Bengaluru
  • Hospital laboratories
  • Preventive health centres
  • Clinical chemistry laboratories
  • Medical institutions
  • Professional healthcare buyers

Customers outside Bangalore can also order laboratory products through microsidd.com for delivery to serviceable locations across India.


Local Search Relevance

This product is relevant for buyers searching for:

  • HDL cholesterol reagent supplier in Bangalore
  • Direct HDL reagent Bengaluru
  • Swemed HDL Cholesterol Reagent Bangalore
  • HDL reagent kit India
  • HDL direct enzymatic reagent supplier
  • Lipid profile reagent supplier Bangalore
  • Clinical chemistry reagent supplier Bengaluru
  • Biochemistry reagent supplier Karnataka
  • Pathology lab reagent supplier near me
  • HDL cholesterol test reagent online India
  • Swemed Diagnostics reagent supplier India

Product Summary

What is Swemed HDL Cholesterol Reagent?

The Swemed HDL Cholesterol Direct Enzymatic Liquid Reagent is a professional two-reagent clinical biochemistry assay for quantitative determination of HDL cholesterol in serum and plasma.

What method does it use?

It uses a direct enzymatic two-reagent method involving selective detergent chemistry to measure HDL cholesterol without a separate precipitation step.

Which specimens can be used?

Fresh serum, EDTA plasma and heparinized plasma are acceptable. Citrate-containing anticoagulants should not be used.

What wavelength is required?

The manufacturer specifies 630 nm.

What is the sample volume?

The assay uses 10 µl of sample.

What is the linearity?

The stated linearity is 180 mg/dL.

Are the reagents ready to use?

Yes. Swemed states that the reagents are supplied ready to use.

Where can Swemed HDL Cholesterol reagent be purchased?

It can be ordered from Microsidd India through microsidd.com, subject to stock availability and delivery serviceability.


GEO and Entity Information

Entity Details
Product HDL Cholesterol Reagent
Brand Swemed Diagnostics
Method Direct Enzymatic
Assay Format Two-Reagent Liquid
Analyte HDL Cholesterol / HDL-C
Specimen Serum / EDTA Plasma / Heparin Plasma
Category Laboratory Reagents
Subcategory Biochemistry Reagents
Clinical Category Lipid Profile
Seller Microsidd India
City Bangalore / Bengaluru
State Karnataka
Country India
Website microsidd.com
Buyer Type Laboratory / Healthcare / B2B

Why Buy Swemed HDL Cholesterol Reagent from Microsidd.com?

Laboratory reagents require more careful procurement than ordinary consumer products. Buyers should verify the correct analyte, method, reagent configuration, analyser compatibility, storage requirements, product source, expiry and seller accountability before placing an order.

Microsidd India has been associated with IVD and diagnostic-product supply since 2000 and focuses on diagnostic, laboratory and healthcare products. This specialist background makes microsidd.com suitable for laboratories that prefer purchasing from an identifiable diagnostic supplier rather than an unrelated marketplace seller.

Microsidd also maintains established and authorised manufacturer relationships across multiple diagnostic-product categories, providing professional buyers with a dependable procurement channel for recurring laboratory requirements.


Microsidd.com vs Online Marketplaces vs Offline Suppliers

Buying Factor Microsidd.com Large Online Marketplaces Offline / Local Suppliers
Seller Specialisation Diagnostic, laboratory and healthcare focused Expertise varies by seller Depends on dealer
Laboratory Product Knowledge Product-focused support Often general marketplace support Dealer dependent
Seller Identity Direct purchase from Microsidd India Marketplace and actual seller may differ Usually identifiable locally
Manufacturer Relationships Established diagnostic manufacturer relationships across multiple categories Depends on seller Varies
Product Verification Method, analyte and specifications can be checked before ordering Similar listings may cause confusion Depends on available stock
GST Invoice Available for eligible purchases Seller dependent May vary
B2B Procurement Suitable for laboratories and institutions Seller dependent Commonly local
Product Range Specialist diagnostic and laboratory catalogue Broad but not specialised Usually limited by local inventory
Customer Support Direct Microsidd support Marketplace plus seller layer Local support
Accountability One identifiable specialist supplier Sellers may vary Depends on supplier
Online Convenience Direct ordering through microsidd.com Convenient May require store visit or phone ordering
Geographic Reach India-wide subject to serviceability Broad Typically local or regional

Benefits of Buying from Microsidd.com

Microsidd Advantage Benefit to Laboratory Buyers
Specialist Diagnostic Supplier Better alignment with professional laboratory requirements
IVD Experience Since 2000 Long-standing diagnostic-product experience
Manufacturer Relationships Established and authorised relationships across diagnostic categories
Direct Seller Accountability Purchase directly from Microsidd India
GST Invoice Suitable for professional and institutional procurement
Product Verification Support Buyers can confirm specifications before ordering
Multi-Category Procurement Reagents, diagnostic kits and consumables available together
Bangalore-Based Operations Convenient for Bengaluru and Karnataka laboratories
India-Wide Supply Useful for laboratories outside Bangalore
Direct Customer Support Product and order queries handled by Microsidd

Frequently Asked Questions

What is Swemed HDL Cholesterol Reagent used for?

It is intended for quantitative determination of HDL cholesterol in serum and plasma using a direct enzymatic method.

Is this a direct HDL assay?

Yes. The Swemed product uses a direct enzymatic two-reagent method.

Which specimens are acceptable?

Fresh serum, EDTA plasma and heparinized plasma are acceptable.

Can citrate plasma be used?

No. The manufacturer states that anticoagulants containing citrate should not be used.

What wavelength does the assay require?

The assay is measured at 630 nm.

What is the sample volume?

The manufacturer specifies 10 µl.

How much reagent is used?

The specified automated parameters are 800 µl Reagent 1 and 200 µl Reagent 2.

What is the assay linearity?

The method is linear up to 180 mg/dL.

Are the reagents ready to use?

Yes. The reagents are supplied ready to use.

Does the calibrator need preparation?

Yes. The lyophilized calibrator should be reconstituted using the exact volume of deionized water specified on its label and allowed to stand at room temperature for approximately 30 minutes.

How should the reagent be stored?

Store at 2–8°C according to the manufacturer instructions.

How long is the sample stable?

The manufacturer states sample stability of 7 days at 2–8°C.

Is the product intended for home testing?

No. It is intended for professional in vitro diagnostic use only.

Can it be used on any biochemistry analyser?

The laboratory should verify analyser compatibility, wavelength, reagent programming and validated application before ordering.

Where can I buy Swemed HDL Cholesterol reagent in Bangalore?

The product can be ordered from Microsidd India through microsidd.com, subject to availability.

Can laboratories outside Bangalore buy from Microsidd.com?

Yes. Microsidd supplies diagnostic and laboratory products to serviceable locations across India.


Medical and Laboratory Disclaimer

The information on this product page is provided for general product identification, procurement and educational purposes only.

This product is intended for professional in vitro diagnostic use by trained laboratory personnel.

The information provided by Microsidd India does not replace the official Swemed Diagnostics product insert, analyser instructions, laboratory standard operating procedures, calibration requirements, quality-control procedures or professional medical judgement.

Specimen requirements, methodology, reagent preparation, analyser settings, calibration, reference intervals, storage, stability, quality-control requirements and interpretation should always follow the current manufacturer instructions.

Laboratory results must be interpreted by qualified healthcare professionals together with the patient's clinical information and other relevant investigations.


No Return / No Exchange Policy

This product is non-returnable and non-exchangeable.

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

For laboratory reagents, customers should specifically verify the test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Didn't find the product you were looking for?