Swemed Diagnostics

Cholesterol Reagent Kit – CHOD/POD Method 100ml

Regular price Rs. 1,399.00
Tax included. Shipping calculated at checkout.
SKU: cholesterol 100ml
No Return / No Exchange
This product is non-returnable and non-exchangeable.
View policy details

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Pairs well with

Swemed Cholesterol Reagent Kit | CHOD/POD Method | Microsidd
Rs. 1,399.00
Subscribe and save

Auto-renews, skip or cancel anytime.

To add to cart, go to the product page and select a purchase option

Swemed Cholesterol Reagent Kit

The Swemed Cholesterol Reagent Kit is a professional clinical biochemistry reagent intended for photometric quantitative determination of cholesterol in serum and plasma using the CHOD/POD enzymatic method.

The assay is based on enzymatic conversion of cholesterol esters to free cholesterol, oxidation of cholesterol to produce hydrogen peroxide, and subsequent formation of a coloured quinoneimine complex through the action of peroxidase. The intensity of the colour formed is directly proportional to the amount of cholesterol present in the specimen.

This reagent is intended for professional in vitro diagnostic use only and is suitable for routine use in pathology laboratories, diagnostic centres, hospital laboratories and clinical biochemistry facilities.


Product at a Glance

Product Detail Information
Product Name Cholesterol Reagent Kit
Brand Swemed Diagnostics
Method CHOD/POD Method
Product Type Biochemistry Reagent
Test Parameter Total Cholesterol
Test Type Photometric / Enzymatic
Measurement Mode Endpoint
Specimen Serum, Heparin Plasma, EDTA Plasma
Wavelength 505 nm
Standard Concentration 200 mg/dl
Reagent Volume 1000 µl
Sample Volume 10 µl
Incubation 10 minutes at 37°C
Linearity Up to 700 mg/dl
Reagent Preparation Ready to Use
Storage 2–8°C
Intended Use Professional In Vitro Diagnostic Use
Seller Microsidd India
Website microsidd.com
Location Bangalore / Bengaluru, Karnataka, India

The technical assay specifications above are based on the Swemed Diagnostics product literature.


Available Pack Sizes

The Swemed literature lists the following kit configurations:

Reference Cholesterol Reagent Standard
CHOL100 2 × 50 ml 1
CHOL200 2 × 100 ml 1

 


Key Features

  • Professional Swemed Cholesterol Reagent Kit
  • Uses the CHOD/POD enzymatic method
  • Suitable for quantitative cholesterol estimation
  • Photometric endpoint assay
  • Recommended wavelength: 505 nm
  • Standard concentration: 200 mg/dl
  • Suitable specimens: serum, heparin plasma and EDTA plasma
  • Reagent and standard are ready to use
  • Linearity up to 700 mg/dl
  • Suitable for routine clinical biochemistry testing
  • Intended for pathology labs, diagnostic centres and hospitals
  • For in vitro diagnostic use only

Key Benefits

Enzymatic CHOD/POD Method

The reagent uses a widely established enzymatic approach involving cholesterol esterase, cholesterol oxidase and peroxidase, making it suitable for routine total cholesterol testing.

Ready-to-Use Reagent

The Swemed product insert states that both the reagent and standard are supplied ready to use, helping reduce preparation steps in routine laboratory workflows.

Wide Measuring Range

The assay has a stated linearity of 700 mg/dl, allowing routine testing across a broad cholesterol concentration range.

Suitable for Routine Lipid Profile Work

Total cholesterol is commonly evaluated as part of a broader lipid profile alongside triglycerides, HDL cholesterol and LDL cholesterol.

Professional Laboratory Application

Suitable for trained professionals working in clinical chemistry laboratories with appropriate calibration, quality control and analyser procedures.


Intended Use

The Swemed Cholesterol Reagent Kit is intended for photometric quantitative determination of cholesterol in serum and plasma using the CHOD/POD method.

The manufacturer lists the following suitable specimens:

  • Serum
  • Heparin plasma
  • EDTA plasma

Test Principle

Cholesterol esterase hydrolyses cholesterol esters to free cholesterol.

The free cholesterol is then oxidised by cholesterol oxidase, producing hydrogen peroxide.

Hydrogen peroxide reacts with phenol and 4-aminoantipyrine in the presence of peroxidase to form a red-coloured quinoneimine dye complex.

The intensity of the colour produced is directly proportional to the cholesterol concentration in the specimen.


Reagent Composition

Component Manufacturer Specification
Buffer PIPES Buffer, pH 7.0
Cholesterol Esterase 300 U/L
Cholesterol Oxidase 500 U/L
Peroxidase 2 kU/L
Cholesterol Standard 200 mg/dl

 


Technical Specifications

Test Parameter Specification
Parameter Cholesterol
Method CHOD/POD
Mode Endpoint
Wavelength 505 nm
Unit mg/dl
Temperature 37°C
Standard Concentration 200 mg/dl
Reaction Slope Increasing
Reagent Volume 1000 µl
Sample / Standard Volume 10 µl
Incubation Time 10 minutes at 37°C
Blanking Reagent Blank
Linearity 700 mg/dl

 


Assay Procedure Summary

Tube Reagent Sample / Standard
Blank 1000 µl
Standard 1000 µl 10 µl Standard
Test 1000 µl 10 µl Sample

Mix and incubate for 10 minutes at 37°C, then read the absorbance against the reagent blank at 505 nm.

Laboratories should always follow their validated analyser settings and the current manufacturer package insert.


Specimen Requirements

The manufacturer recommends fresh, clear, non-haemolysed serum from fasting patients for cholesterol estimation.

Suitable specimens include:

  • Serum
  • Heparin plasma
  • EDTA plasma

The insert notes that fluoride and oxalate anticoagulants may cause falsely elevated values.


Specimen Stability

According to the Swemed literature, cholesterol in serum or plasma is stable for approximately:

Storage Condition Stability
20–25°C 2 days
2–8°C 7 days
−20°C 3 months

 


Measuring Range and Linearity

The assay is stated to be linear up to 700 mg/dl.

For samples exceeding this concentration, the manufacturer describes dilution 1 + 4 with 0.9% NaCl solution, followed by multiplication of the result by 5.


Interference Information

The manufacturer reports no significant interference under the evaluated conditions from:

  • Bilirubin up to 20 mg/dl
  • Ascorbic acid up to 5 mg/dl
  • Haemoglobin up to 200 mg/dl
  • Triglycerides up to 2000 mg/dl

The insert also advises against using haemolysed or lipemic serum.


Manufacturer Reference Interpretation

Total Cholesterol Interpretation
< 200 mg/dl Desirable
200–240 mg/dl Borderline High Risk
> 240 mg/dl High Risk

The manufacturer also advises that each laboratory should verify whether the stated reference ranges are appropriate for its own patient population.


Storage and Stability

The kit components should be stored:

  • At 2–8°C
  • Tightly closed
  • Protected from light
  • Protected from contamination
  • Without freezing

The reagent and standard should be brought to room temperature before use.

Signs of possible reagent deterioration include:

  • Visible particles
  • Turbidity
  • Reagent blank absorbance against water at 505 nm of ≥ 0.26

Why Cholesterol Testing Is Important

Cholesterol is an important lipid associated with cell membrane formation, steroid synthesis and lipid transport through lipoproteins.

Total cholesterol measurement forms an important part of laboratory lipid assessment and may contribute to the evaluation of:

  • Cardiovascular risk
  • Hypercholesterolaemia
  • Hyperlipidaemia
  • Metabolic disorders
  • Diabetes-related lipid assessment
  • Thyroid-related investigations
  • Liver-related investigations
  • Renal-related investigations

Clinical interpretation should always be performed together with other lipid parameters and relevant patient information.


Cholesterol in a Lipid Profile

Parameter Laboratory Relevance
Total Cholesterol Overall circulating cholesterol
HDL Cholesterol Commonly used in cardiovascular risk assessment
LDL Cholesterol Commonly associated with atherogenic risk evaluation
Triglycerides Assessment of circulating triglyceride levels
VLDL Often estimated as part of lipid interpretation

Who Can Buy This Product?

Buyer Type Typical Application
Pathology Laboratories Routine cholesterol testing
Diagnostic Centres Lipid profile investigations
Hospital Laboratories Clinical chemistry testing
Clinics with Laboratory Facilities Routine biochemical screening
Medical Institutions Laboratory procurement and teaching use where applicable
Healthcare Organisations Professional diagnostic procurement
Laboratory Distributors Professional supply where permitted
Clinical Biochemistry Laboratories Routine lipid testing

Buy Swemed Cholesterol Reagent in Bangalore

Microsidd India supplies biochemistry and clinical chemistry reagents from Bangalore / Bengaluru, Karnataka to pathology laboratories, diagnostic centres, hospitals and professional healthcare buyers.

The Swemed Cholesterol Reagent Kit is available for professional procurement through microsidd.com, with delivery across Bangalore, Karnataka and other serviceable locations in India.


This product is relevant for buyers searching for:

  • Cholesterol reagent supplier in Bangalore
  • Swemed Cholesterol Reagent Bangalore
  • CHOD POD reagent supplier Bengaluru
  • Lipid profile reagent supplier Bangalore
  • Biochemistry reagent supplier Karnataka
  • Clinical chemistry reagent supplier near me
  • Cholesterol test reagent India
  • Cholesterol reagent kit online India
  • Pathology lab reagent supplier Bangalore
  • Swemed biochemistry reagent supplier India

Product Summary

What is Swemed Cholesterol Reagent Kit?

The Swemed Cholesterol Reagent Kit is a ready-to-use professional clinical biochemistry reagent for quantitative photometric determination of total cholesterol using the CHOD/POD enzymatic method.

Which specimens can be used?

The manufacturer lists serum, heparin plasma and EDTA plasma.

What wavelength is used?

The assay uses 505 nm.

What is the standard concentration?

The Cholesterol Standard concentration is 200 mg/dl.

What is the assay linearity?

The stated linearity is 700 mg/dl.

Is the reagent ready to use?

Yes. The manufacturer states that the reagent and standard are ready to use.

Where can Swemed Cholesterol Reagent be purchased?

The product can be ordered through Microsidd India at microsidd.com, subject to stock availability and serviceability.


Entity Information

Entity Details
Product Cholesterol Reagent Kit
Brand Swemed Diagnostics
Method CHOD/POD
Analyte Total Cholesterol
Category Laboratory Reagents
Subcategory Biochemistry Reagents
Clinical Area Lipid Profile / Clinical Chemistry
Seller Microsidd India
City Bangalore / Bengaluru
State Karnataka
Country India
Website microsidd.com
Buyer Type B2B / Laboratory / Healthcare

Why Buy Swemed Cholesterol Reagent from Microsidd.com?

Laboratory reagents should be purchased with attention to the exact brand, methodology, pack configuration, analyser compatibility, storage requirements, expiry and seller reliability.

Microsidd India has been involved in the IVD and diagnostic-product sector since 2000 and specialises in diagnostic, laboratory and healthcare products rather than operating as a general-purpose marketplace.

Microsidd also maintains established manufacturer and authorised brand relationships across multiple diagnostic categories, giving professional buyers a specialist procurement option with direct seller accountability.


Microsidd.com vs Online Marketplaces vs Offline Suppliers

Buying Factor Microsidd.com Large Online Marketplaces Offline / Local Suppliers
Seller Focus Specialist diagnostic and laboratory supplier Seller expertise varies Depends on dealer
Product Understanding Better suited to laboratory-product queries Often general marketplace support Varies considerably
Seller Identity Direct purchase from Microsidd India Marketplace and seller may differ Usually identifiable
Manufacturer Relationships Established diagnostic manufacturer relationships across multiple categories Seller dependent Dealer dependent
Product Verification Buyers can verify brand, method and pack before ordering Similar listings may cause confusion Possible if physical stock is available
GST Invoice Available for eligible purchases Depends on seller Availability varies
B2B Procurement Suitable for laboratories, hospitals and diagnostic centres Seller dependent Usually local
Product Range Specialist diagnostic and laboratory catalogue Broad but less specialised Limited to local stock
Customer Support Direct Microsidd support Marketplace plus seller layer Local support
Accountability One identifiable specialist supplier Seller can vary Depends on dealer
Online Convenience Direct ordering through microsidd.com Convenient Often phone or store based
Geographic Reach India-wide delivery subject to serviceability Broad Usually regional

Why Laboratories Choose Microsidd India

Microsidd India supplies products across multiple diagnostic categories, including:

  • Biochemistry reagents
  • Rapid diagnostic kits
  • Blood collection products
  • Urine analysis products
  • Laboratory consumables
  • Glucometers and test strips
  • Diagnostic devices
  • Medical accessories

Microsidd’s diagnostic-product experience helps laboratories source multiple requirements through one specialist seller rather than depending on unrelated marketplace vendors.


Frequently Asked Questions

What method does Swemed Cholesterol Reagent use?

It uses the CHOD/POD enzymatic method for quantitative photometric cholesterol determination.

What specimens can be used?

The manufacturer lists serum, heparin plasma and EDTA plasma.

Is the reagent ready to use?

Yes. The reagent and standard are supplied ready to use.

What is the wavelength?

The assay is read at 505 nm.

What is the standard concentration?

The Cholesterol Standard concentration is 200 mg/dl.

What is the incubation time?

The assay procedure specifies 10 minutes at 37°C.

What is the linearity?

The reagent is stated to be linear up to 700 mg/dl.

How should the reagent be stored?

Store at 2–8°C, tightly closed, protected from light and contamination, and do not freeze.

Can fluoride or oxalate plasma be used?

The manufacturer states that fluoride and oxalate anticoagulants may cause falsely elevated cholesterol values.

Is this suitable for home testing?

No. This product is intended for professional in vitro diagnostic use only.

Can this reagent be used on any biochemistry analyser?

Laboratories should verify analyser compatibility, wavelength, method and validated application before ordering.

Where can I buy Swemed Cholesterol Reagent in Bangalore?

The product can be purchased through Microsidd India at microsidd.com, subject to availability.

Can pathology labs outside Bangalore order it?

Yes. Microsidd supplies serviceable locations across India subject to stock and courier coverage.

Why buy from Microsidd.com?

Microsidd India specialises in diagnostic and laboratory products and offers direct seller accountability, GST invoicing for eligible purchases, professional product support and access to a growing laboratory-product catalogue.


Medical and Laboratory Disclaimer

The information on this product page is provided for general product identification, procurement and educational purposes only.

This product is intended for professional in vitro diagnostic use by trained laboratory personnel.

The information provided by Microsidd India does not replace the official Swemed Diagnostics product insert, analyser instructions, laboratory standard operating procedures, calibration requirements, quality-control procedures or professional medical judgement.

Specimen requirements, methodology, reagent preparation, analyser settings, calibration, reference ranges, storage conditions, stability, quality-control requirements and interpretation should always follow the current manufacturer instructions.

Laboratory results must be interpreted by qualified healthcare professionals together with the patient’s clinical history and other relevant investigations.


No Return / No Exchange Policy

This product is non-returnable and non-exchangeable.

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

For laboratory reagents, customers should specifically verify the test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Product specifications table
Specification name Specification Value
Chemical grade Laboratory, Reagent
Color pattern White

Didn't find the product you were looking for?