Mission Hemoglobin Monitor and Hb test strips complete guide for hemoglobin and hematocrit testing

Mission Hemoglobin Monitor & Test Strips Complete Guide: Hb, Hct, Compatibility, Use & Specifications

The Mission Hemoglobin Monitor from Mission / ACON is a portable digital point-of-care testing system designed for rapid quantitative measurement of Hemoglobin (Hb) and calculated Hematocrit (Hct).

The current Mission Hb system requires approximately 10 µL of capillary or venous whole blood and provides results in less than approximately 15 seconds when used with compatible Mission Hemoglobin Test Strips.

The Microsidd starter configuration currently includes the Mission Hb Meter with 10 compatible Hb strips, making it a convenient option for customers who want both the meter and an initial strip supply.

This guide covers Mission Hb strip compatibility, testing method, sample requirement, Hb and Hct measurement ranges, memory, calibration, available strip packs, storage and practical buying information.

Shop the meter: Mission Hemoglobin Monitor with 10 Strips →

Compatible refill strips: Mission Hemoglobin Test Strips 50 →


What Is the Mission Hemoglobin Monitor?

The Mission Hemoglobin Monitoring System is a digital Hb testing platform from Mission / ACON designed for rapid point-of-care hemoglobin measurement.

The system provides:

  • quantitative Hemoglobin (Hb), and
  • calculated Hematocrit (Hct).

It uses compatible dry-reagent Mission Hb Test Strips together with an appropriately collected whole-blood specimen.


Mission Hemoglobin Monitor Specifications

Specification Mission Hb System
Brand Mission / ACON
Measured parameter Hemoglobin (Hb)
Additional output Calculated Hematocrit (Hct)
Method Reflectance photometry
Detection principle Methemoglobin
Approx. wavelength 525 nm
Sample type Capillary or venous whole blood
Approx. sample volume 10 µL
Approx. result time Less than 15 seconds
Hb measurement range Approx. 4.0–25.6 g/dL
Calculated Hct range Approx. 13–75%
Memory Up to approximately 1,000 results
Stored information Date, time and ID
Calibration Automatic with the appropriate strip coding / calibration system
Data interface Mini USB
Power 4 × AAA batteries
Operating temperature Approx. 10–40°C
Operating humidity Approx. ≤90% RH
Automatic shut-off Approx. 8 minutes

What Does the Mission Hb Meter Measure?

Hemoglobin (Hb)

The primary measurement is the concentration of hemoglobin in whole blood.

Hemoglobin is the oxygen-carrying protein contained inside red blood cells.

Calculated Hematocrit (Hct)

The compatible Mission system also provides a calculated hematocrit percentage.

Hematocrit represents the approximate proportion of blood volume occupied by red blood cells.

The displayed Hct is a calculated system output and should not automatically be considered identical to a direct hematocrit measurement obtained by another laboratory method.


Which Test Strips Work with the Mission Hb Meter?

Use compatible:

Mission Hemoglobin Test Strips.

Microsidd currently offers a 50-strip replacement pack.

Shop Mission Hemoglobin Test Strips 50 →

Mission Hb strips should not be assumed to be interchangeable with:

  • Quikchek Plus Hb strips,
  • TrueHb strips,
  • blood glucose test strips, or
  • HbA1c test cartridges.

For detailed compatibility information:

Mission Hb Test Strip Compatibility Guide →


What Is Included with the Mission Hb Meter?

The current Microsidd Mission starter kit includes:

Pack Component Quantity
Mission Hemoglobin Monitor 1
Compatible Mission Hb Test Strips 10
Lancing Device 1
Carry Case 1
User Guide 1

Pack contents can change, so customers should always check the current product listing and supplied box before ordering.

View Mission Hb Meter with 10 Strips →


Mission Hb Test Strips 50 Pack

Customers who already own the compatible meter can purchase the 50-strip refill pack separately.

The current standard product configuration is typically supplied as:

25 strips per canister × 2 canisters = 50 strips

The pack also includes the applicable strip information and calibration / coding component supplied for the system.

Shop Mission Hb Test Strips 50 →


Mission Hb Meter Combo with More Strips

Microsidd also offers a larger meter-and-strip combination for customers who want additional testing supplies from the beginning.

The current larger configuration combines the Mission meter starter pack with an additional 50-strip supply, giving a higher total initial strip quantity.

Shop Mission Hb Meter Larger Strip Combo →


How Much Blood Does the Mission Hb Meter Need?

The current system requires approximately:

10 µL of whole blood per test.

Supported specimen types include:

  • capillary whole blood, and
  • venous whole blood.

Use the exact collection and application procedure specified in the current Mission instructions.


How Fast Is the Mission Hemoglobin Test?

The current system provides an Hb result in:

less than approximately 15 seconds.

This rapid result time can be useful in professional point-of-care workflows where a quick Hb assessment is required.


Mission Hb Measurement Range

The current Mission Plus Hb specification lists an Hb measurement range of approximately:

4.0–25.6 g/dL

The calculated Hct range is approximately:

13–75%


How Does the Mission Hemoglobin Monitor Work?

The Mission system uses:

  • reflectance photometry, and
  • a methemoglobin detection principle.

A simplified testing process is:

  1. Insert the correct Mission Hb Test Strip.
  2. Prepare the required whole-blood specimen.
  3. Apply approximately 10 µL of blood as instructed.
  4. The strip reagents react with hemoglobin.
  5. The meter measures the optical response.
  6. The system calculates and displays the Hb result.
  7. The corresponding calculated Hct value is also displayed.

What Is Reflectance Photometry?

Reflectance photometry is an optical measurement technique.

After the blood specimen reacts with the dry reagents on the compatible Mission strip, the meter measures reflected light from the reaction area.

The system then converts that optical signal into a quantitative hemoglobin measurement.


How to Use the Mission Hemoglobin Monitor

The general workflow includes:

  1. Prepare the Mission meter and testing supplies.
  2. Confirm the correct Mission Hb Test Strip.
  3. Check strip expiry and condition.
  4. Insert the strip correctly.
  5. Obtain the required capillary or venous whole-blood specimen.
  6. Apply approximately 10 µL of blood according to instructions.
  7. Allow the meter to complete the test.
  8. Read the Hb and calculated Hct results.
  9. Record the result where required.
  10. Dispose of used blood-contact materials appropriately.

For the full step-by-step article:

How to Use Mission Hemoglobin Monitor & Hb Strips →


Mission Hb Calibration & Code Information

The Mission Hb testing system uses the appropriate strip coding / calibration component supplied with the compatible strip system.

When beginning a new strip supply:

  • follow the instructions supplied with the strip pack,
  • use the correct calibration or coding component, and
  • do not substitute one from another meter or strip system.

Automatic system calibration does not mean that lot-specific setup instructions can be ignored.


Mission Hb Meter Memory

The meter can store up to approximately:

1,000 test results

with information including:

  • date,
  • time, and
  • ID number.

This can be useful in point-of-care environments where multiple results need to be maintained or reviewed.


Mission Hb Mini USB Interface

The current meter includes a Mini USB interface for compatible data transfer.

Actual data-transfer functionality depends on the compatible software and workflow being used.


Mission Hb Power Supply

The current Mission Hb meter uses:

4 × AAA 1.5 V batteries

and can also support compatible external power according to the system specification.

The current technical information lists approximate battery capability of up to 2,700 tests or 360 operating hours, depending on use.


Mission Hb Operating Conditions

The current meter specification lists:

  • Operating temperature: approximately 10–40°C
  • Operating humidity: approximately ≤90% RH

The meter and the test strips may have different storage specifications, so do not use meter storage conditions as a substitute for strip storage guidance.


Mission Hb Strip Storage

Current Mission Hb strip specifications list storage at approximately:

  • 2°C–30°C, and
  • ≤85% relative humidity.

The strips should remain in their original manufacturer container and the canister should be closed promptly after removing a strip.

For detailed guidance:

Mission Hemoglobin Strips Expiry & Storage Guide →


Mission Hb vs Quikchek Plus Hb

Mission and Quikchek Plus share several core characteristics.

Feature Mission Hb Quikchek Plus
Hb measurement Yes Yes
Calculated Hct Yes Yes
Approx. sample 10 µL 10 µL
Approx. result time <15 sec <15 sec
Hb range Approx. 4.0–25.6 g/dL Approx. 4.5–25.6 g/dL
Memory Up to 1,000 Up to 1,000
Compatible strips Mission Hb Quikchek Plus Hb

Despite the similarities, do not assume the strips are interchangeable.


Mission Hb vs TrueHb

Feature Mission Hb TrueHb
Approx. sample 10 µL 10–12 µL
Approx. result time <15 sec Within 60 sec
Calculated Hct Yes Not listed as primary output
Memory Up to 1,000 Up to 1,000
Power AAA batteries Rechargeable battery
Compatible strips Mission Hb TrueHb

For the full comparison:

Quikchek Plus vs Mission vs TrueHb Hemoglobin Meter Comparison →


Is Mission Hb a Glucometer?

No.

A glucometer measures blood glucose.

The Mission Hemoglobin Monitor measures hemoglobin concentration and provides calculated hematocrit.

Glucose test strips cannot be substituted for Mission Hb Test Strips.


Does Mission Hb Measure HbA1c?

No.

The Mission Hb system described here measures hemoglobin concentration.

HbA1c is a different diagnostic parameter and requires a dedicated HbA1c testing system.


Can Mission Hb Diagnose Anemia?

The meter provides a quantitative Hb result that may support anemia screening and clinical assessment.

The result does not by itself determine:

  • the cause of a low Hb value,
  • the type of anemia,
  • iron status,
  • vitamin deficiency, or
  • the appropriate treatment.

Clinical interpretation may require additional evaluation and laboratory testing.


Who May Use the Mission Hemoglobin Monitor?

The system is particularly suited to applicable professional point-of-care settings such as:

  • hospitals,
  • physician clinics,
  • diagnostic centres,
  • nursing facilities,
  • health-screening programmes,
  • medical camps,
  • occupational health programmes, and
  • community healthcare services.

Use should remain consistent with the manufacturer's intended-use information and applicable professional procedures.


Which Mission Hb Pack Should You Buy?

Your Requirement Mission Option
New user needing a starter kit Mission Hb Meter + 10 strips
Already own the compatible meter Mission Hb Test Strips 50
Want meter + larger initial strip quantity Mission Hb larger combo
Repeat professional testing Compare ongoing 50-strip refill requirements

If You Already Own a Mission Hb Meter

You normally only need the compatible refill strips.

Microsidd currently supplies:

Mission Hemoglobin Test Strips 50 →

Before ordering, verify the exact Mission Hb meter model printed on your device.


Frequently Asked Questions

What does the Mission Hemoglobin Monitor measure?

It measures quantitative Hemoglobin (Hb) and provides calculated Hematocrit (Hct).

How much blood does the test require?

Approximately 10 µL of whole blood.

How fast is the result?

Less than approximately 15 seconds.

Can capillary blood be used?

Yes. The current system supports capillary whole blood.

Can venous blood be used?

Yes. Appropriately collected venous whole blood is also supported.

What is the Hb measurement range?

Approximately 4.0–25.6 g/dL.

What is the calculated Hct range?

Approximately 13–75%.

How many results can be stored?

Up to approximately 1,000 results.

Does the meter have USB connectivity?

Yes. The current system includes a Mini USB interface.

How is the meter powered?

The current meter uses four AAA batteries and supports compatible external power according to the system specification.

How many strips come with the current starter kit?

The current Microsidd starter configuration includes 10 Mission Hb Test Strips.

How many strips are in the refill pack?

The replacement product contains 50 strips, typically supplied as two canisters of 25.

Can Quikchek Plus strips be used?

Do not substitute Quikchek Plus strips. Use the Mission strip system specified for the Mission Hb meter.

Can TrueHb strips be used?

No substitution should be made. TrueHb is a separate testing platform.

Is Mission Hb a glucose meter?

No. It measures hemoglobin rather than blood glucose.

Does it measure HbA1c?

No. HbA1c requires a separate appropriate analyser.


Mission Hb Knowledge Hub


Shop Mission Hb Products

Mission Hemoglobin Monitor with 10 Strips →

Mission Hemoglobin Test Strips 50 →

Mission Hb Meter Larger Strip Combo →

Browse the complete Hb category:

Hemoglobin Meters & Test Strips →


Compatibility notice: Use only the Mission Hb test-strip system specified for the exact compatible Mission Hemoglobin Monitor. Verify the meter model, strip pack, coding / calibration requirements, expiry and storage conditions before testing.

Medical information notice: This guide provides technical and product information about the Mission Hemoglobin Monitoring System. It does not diagnose anemia, identify the cause of an abnormal Hb value, recommend testing frequency or replace the manufacturer's instructions, professional training or clinical assessment.

Previous Next

Leave a comment

0 comments

Please note, comments need to be approved before they are published.