The Meril Merilyzer EIAWash ELISA Microplate Washer is a professional laboratory instrument designed for automated washing of microtiter plates used in ELISA and compatible microplate-based immunoassays.
Correct washing is a critical part of the ELISA workflow because unbound sample components and reagents must be removed between assay stages while retaining the specific antigen-antibody reaction within the wells.
The EIAWash provides programmable washing, adjustable dispensing volumes, configurable wash cycles, shaking and soaking functions, and support for different microwell geometries to help laboratories standardise routine ELISA plate-washing procedures.
It is suitable for diagnostic laboratories, hospital laboratories, blood banks, serology laboratories, microbiology departments and other professional healthcare laboratories performing compatible ELISA assays.
Brand: Meril Diagnostics
Product Name: Merilyzer EIAWash
Product Type: ELISA Microplate Washer
Category: Laboratory Equipment
Subcategory: ELISA Washer / Microplate Washer
Application: Automated Washing of ELISA Microplates
Compatible Well Types: Flat Bottom / U Bottom / Round Bottom
Washing Manifold: 8 Channel / 12 Channel
Programmable Tests: Up to 100
Wash Cycles: Programmable 0–255
Wash Volume: 50–400 µL per well
Wash Volume Increment: 50 µL
Residual Volume: <2 µL
Washing Accuracy: <±3% at 300 µL
Shake Rate: 1–5 Levels
Shake Time: 0–255 Seconds
Soak Function: Programmable
Display: 192 × 64 Pixel Monochrome LCD with LED Backlight
Operating Temperature: 5°C–40°C
Relative Humidity: <95%
Power Supply: 100–240 VAC, 50/60 Hz
Maximum Power: 55 W
Dimensions: Approx. 390 × 410 × 330 mm
Weight: Approx. 11.5 kg
Intended Use: Professional Laboratory Use
Seller: Microsidd India
Location: RT Nagar, Bengaluru, Karnataka, India
The Merilyzer EIAWash is an automated plate washer used during ELISA testing.
An ELISA assay normally involves several stages where liquid reagents are added to microplate wells, incubated, and subsequently removed.
Between these stages, the wells must be washed thoroughly to remove unbound material.
The EIAWash automates this process by dispensing wash buffer into the wells and aspirating the liquid according to a programmed wash protocol.
This helps laboratories achieve more consistent washing compared with purely manual plate-washing techniques.
ELISA results depend not only on the reader and reagents, but also on proper washing.
Insufficient washing may leave unbound enzyme conjugate or sample components in the wells, potentially increasing background optical density.
Excessively aggressive or inappropriate washing may interfere with the assay reaction.
A programmable microplate washer therefore helps laboratories control important washing parameters such as:
The exact washing program must always follow the requirements of the specific ELISA kit.
The EIAWash supports:
Flat-bottom wells
U-bottom wells
Round-bottom wells
This provides flexibility for laboratories using different microplate formats.
The washer supports 8-channel and 12-channel washing manifolds, allowing laboratories to select an appropriate washing configuration for their workflow.
The system can store up to 100 programmable test protocols, helping laboratories save frequently used wash programs.
This is particularly useful in laboratories running multiple ELISA parameters.
Wash cycles can be programmed from:
0 to 255 cycles
according to the requirements of the assay protocol.
Wash-liquid volume can be set between:
50 µL and 400 µL
with:
50 µL increments
This enables the washing program to be adapted to different assay requirements.
Meril specifies a residual volume of:
<2 µL
after washing under the stated operating conditions.
Low residual liquid can help reduce carryover of unbound material between assay stages.
Manufacturer specifications list washing accuracy of:
<±3% at 300 µL
under the stated conditions.
The EIAWash provides:
5 shake-rate levels
with programmable shaking time from:
0–255 seconds
This may be useful where the assay protocol requires plate agitation during washing.
The instrument provides programmable soaking capability, allowing wash buffer to remain within the wells for a defined period when required by the assay protocol.
The Merilyzer EIAWash incorporates a dedicated bottle system comprising:
1 Wash Buffer Bottle
1 Rinse Water Bottle
1 Pressure Bottle
1 Waste Liquid Bottle
The waste bottle includes a liquid-level sensor to assist with waste-management monitoring during operation.
| Specification | Details |
|---|---|
| Brand | Meril Diagnostics |
| Model | Merilyzer EIAWash |
| Instrument Type | ELISA Microplate Washer |
| Programmable Tests | Up to 100 |
| Microwell Types | Flat, U & Round Bottom |
| Washing Manifold | 8 & 12 Channels |
| Wash Cycles | 0–255 |
| Wash Volume | 50–400 µL |
| Volume Increment | 50 µL |
| Residual Volume | <2 µL |
| Washing Accuracy | <±3% at 300 µL |
| Shake Rate | 1–5 Levels |
| Shake Time | 0–255 Seconds |
| Soak Function | Programmable |
| Display | 192 × 64 Pixel Monochrome LCD |
| Backlight | LED |
| Relative Humidity | <95% |
| Operating Temperature | 5°C–40°C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Maximum Power | 55 W |
| Dimensions | Approx. 390 × 410 × 330 mm |
| Weight | Approx. 11.5 kg |
| Use | Professional Laboratory |
Meril lists these specifications for EIAWash in its ELISA reader/washer technical literature. Meril Life
A typical ELISA washing process involves:
The exact wash-cycle number, buffer volume, soak time and shaking settings must follow the ELISA kit manufacturer’s current Instructions for Use.
An ELISA washer and ELISA reader perform completely different functions.
| Feature | ELISA Washer | ELISA Reader |
|---|---|---|
| Main Function | Washes microplate wells | Measures optical density |
| ELISA Stage | During assay processing | Final/measurement stage |
| Dispenses Wash Buffer | Yes | No |
| Aspirates Wells | Yes | No |
| Measures Absorbance | No | Yes |
| Uses Optical Filters | No | Yes |
| Typically Required Together | Yes, depending on assay workflow | Yes |
For a complete ELISA laboratory setup, a laboratory may require both:
Meril Merilyzer EIAWash – Microplate Washer
and
Meril Merilyzer EIAQuant – ELISA Reader
The EIAWash may support ELISA protocols for parameters such as:
Compatibility depends on the specific plate type and assay washing protocol.
The Merilyzer EIAWash is especially relevant for laboratories already using Meril MeriLisa ELISA kits.
https://microsidd.com/products/merilisa-hiv-96t-pack
https://microsidd.com/products/merilisa-hcv-elisa-3-0-96t-pack
https://microsidd.com/products/merilisa-hbsag-96t-pack
https://microsidd.com/collections/elisa-range
The instrument is intended for appropriately trained professionals working in:
The EIAWash is professional laboratory equipment and is not intended for home use.
The EIAWash can help laboratories improve workflow consistency through:
Programmable washing protocols
Automated aspiration and dispensing
Multiple well-type support
Adjustable wash volume
Configurable wash cycles
Low residual liquid volume
Built-in soaking and shaking
8- and 12-channel manifold options
Stored test programs
Waste-level monitoring
Automation can also reduce repetitive manual washing steps during high-volume ELISA testing.
Reliable plate washing requires correct:
Laboratories should perform routine quality checks and cleaning according to the instrument manual.
The EIAWash should be maintained according to Meril’s current operating instructions.
General good laboratory practices include:
Do not dismantle or service internal components unless authorised.
Install the EIAWash on a stable laboratory bench.
Keep the instrument away from:
Ensure sufficient space around the instrument for ventilation and bottle placement.
The manufacturer's specifications list:
Operating Temperature: 5°C–40°C
Relative Humidity: <95%
The instrument should be operated within its specified environmental limits.
During transport:
After relocation, allow the instrument to stabilise and verify its operation before processing clinical assays.
https://microsidd.com/collections/elisa-range
https://microsidd.com/collections/blood-bank-range
https://microsidd.com/collections/chemicals-liquids
Microsidd India supplies professional laboratory equipment, ELISA kits, blood-bank products and diagnostic reagents to laboratories and healthcare institutions.
Benefits include:
✓ Meril ELISA instruments and reagents in one catalogue
✓ Dedicated ELISA product range
✓ HIV, HCV and HBsAg ELISA kits available
✓ Blood-bank products available
✓ Laboratory reagents and supporting products available
✓ Technical specifications clearly presented
✓ Bengaluru-based customer support
✓ GST invoice where applicable
✓ Institutional supply support subject to availability
✓ Online ordering across serviceable locations in India
Microsidd India supplies ELISA plate washers and diagnostic laboratory equipment in Bengaluru and serves professional customers across serviceable locations in India.
Customers searching for:
ELISA washer Bangalore
ELISA plate washer Bengaluru
microplate washer Bangalore
Meril EIAWash India
ELISA equipment near me
blood bank ELISA equipment Bangalore
order through Microsidd.com subject to stock and serviceability.
Business Name: Microsidd India
Address: #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India
Phone / WhatsApp: +91 63667 72288
Email: support@microsidd.com
Website: https://microsidd.com
Working Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST
Get product explainers, laboratory equipment videos, diagnostic guides and new-product updates:
https://www.youtube.com/channel/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1
Get updates about new diagnostic products, ELISA kits, laboratory equipment and offers:
https://whatsapp.com/channel/0029Va5lCoi1nozBZBL1gx3P
The Merilyzer EIAWash is an automated ELISA microplate washer designed for professional laboratory plate-washing workflows.
It dispenses wash buffer into microplate wells and aspirates liquid between ELISA reaction stages.
No.
An ELISA reader measures optical density. The EIAWash performs plate washing.
It supports flat-, U- and round-bottom microwells.
Meril lists 8-channel and 12-channel manifolds.
Up to 100 programmable tests.
50–400 µL, adjustable in 50 µL increments.
Meril specifies <2 µL.
Manufacturer specification is <±3% at 300 µL.
Yes.
Shake rate can be set from 1 to 5 levels, with adjustable shake time.
Yes. It includes a programmable soaking function.
The system supports programming from 0 to 255 wash cycles.
The system specification includes:
The waste bottle has a liquid-level sensor.
5°C–40°C.
Approximately 11.5 kg.
Approximately 390 × 410 × 330 mm.
Yes, where the ELISA kit uses a compatible microplate and washing protocol.
Yes, subject to the assay protocol.
Yes, subject to the test kit’s current washing instructions.
Most standard ELISA workflows require a compatible microplate reader to measure the final optical density.
No. It is professional laboratory equipment.
This product is non-returnable and non-exchangeable. 2Years Warranty
Please verify the brand, model, plate compatibility, washing-manifold requirement, assay methodology, laboratory workflow and instrument specifications before placing your order.
For laboratory equipment, customers should specifically verify the required methodology, plate format, compatible ELISA kit, washing protocol, laboratory infrastructure and intended application before ordering.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
The Meril Merilyzer EIAWash is intended for professional laboratory use.
The instrument should be installed, programmed, operated, cleaned and maintained by appropriately trained personnel according to the manufacturer’s current operating manual, ELISA kit Instructions for Use, laboratory SOPs and applicable quality-control procedures.
Incorrect washing parameters may affect ELISA assay performance. Wash volume, wash cycles, soaking and shaking parameters should therefore be selected according to the specific reagent kit rather than using one generic program for all assays.
| Specification name | Specification Value |
|---|---|
| Color pattern | White |
| Material | Plastic |