The Meril Merilyzer EIAQuant ELISA Microplate Reader is a professional laboratory instrument designed for photometric reading of 96-well microtiter plates used in ELISA and other absorbance-based microplate assays.
The system is designed for laboratories that require a compact ELISA reader with automated plate feeding, absorbance measurement, result calculation, data processing, quality-control support and built-in printing.
With standard wavelengths of 405 nm, 450 nm, 492 nm and 630 nm, monochromatic and bichromatic reading modes, fast plate-reading capability and an interactive LCD touch screen, the EIAQuant is suitable for diagnostic laboratories, blood banks, hospital laboratories, serology departments and other professional ELISA workflows.
Brand: Meril Diagnostics
Product Name: Merilyzer EIAQuant
Product Type: ELISA Microplate Reader
Category: Laboratory Instruments
Subcategory: ELISA Reader / Microplate Reader
Plate Format: 96-Well Microtiter Plate
Measurement: Absorbance / Optical Density
Standard Wavelengths: 405 nm, 450 nm, 492 nm, 630 nm
Additional Filter Positions: 3 Optional Positions
Reading Modes: Monochromatic and Bichromatic
Single-Wavelength Reading Speed: Approx. 6.5 Seconds
Dual-Wavelength Reading Speed: Approx. 16 Seconds
Optical Density Range: 0–4.0 OD
Light Source: Halogen
Optical System: Eight-Channel Fibre Optics
Display: Large Interactive LCD Touch Screen
Printer: Built-In Thermal Printer
QC: Up to 4 Levels of Control Sera with Levey-Jennings Graph
Functions: Self Diagnosis, Copy Test, Rerun, Automatic Feeding, Automatic Measurement, Data Analysis and Processing
Intended Use: Professional Laboratory Use
Suitable Users: Diagnostic laboratories, blood banks, hospital laboratories, serology laboratories, research and clinical laboratories
Seller: Microsidd India
Location: RT Nagar, Bengaluru, Karnataka
The Merilyzer EIAQuant is a compact ELISA microplate reader used to measure the absorbance of samples processed in a 96-well microtiter plate.
It is designed for laboratories performing qualitative and quantitative enzyme immunoassays where optical-density measurement is required.
The instrument automates several parts of the reading workflow, including:
This makes it suitable for laboratories running routine ELISA assays for infectious disease, hormones and other compatible parameters.
The EIAQuant includes four standard spectral filters:
405 nm
450 nm
492 nm
630 nm
The system also provides three optional filter positions for additional assay requirements.
The instrument supports both:
Monochromatic reading
and
Bichromatic reading
allowing laboratories to select the reading mode required by the assay protocol.
Meril lists the reading speed as approximately:
6.5 seconds at single wavelength
and
16 seconds at dual wavelength
for a compatible microplate.
The instrument supports an optical-density range of 0 to 4.0 OD, providing a broad absorbance measurement range for compatible ELISA assays.
The EIAQuant uses an eight-channel fibre-optic optical system, allowing efficient microplate reading.
A halogen light source is used for absorbance measurement.
A large LCD touch screen provides direct instrument control and easier laboratory operation.
The integrated thermal printer allows laboratories to generate results without requiring a separate external printer for routine reporting.
The EIAQuant supports up to four levels of control sera with a Levey-Jennings graph, helping laboratories monitor assay performance.
The system includes built-in self-diagnostic functionality to support routine instrument checks.
The instrument includes convenient workflow features such as:
Copy Test
and
Rerun
for repeat or related assay processing.
| Specification | Details |
|---|---|
| Brand | Meril Diagnostics |
| Model | Merilyzer EIAQuant |
| Instrument Type | ELISA Microplate Reader |
| Plate Format | 96-Well Microtiter Plate |
| Measurement | Absorbance / Optical Density |
| Standard Filters | 405, 450, 492, 630 nm |
| Optional Filter Positions | 3 |
| Reading Modes | Monochromatic / Bichromatic |
| Single-Wavelength Speed | Approx. 6.5 sec |
| Dual-Wavelength Speed | Approx. 16 sec |
| OD Range | 0–4.0 OD |
| Light Source | Halogen |
| Optical System | Eight-Channel Fibre Optics |
| Display | Large LCD Touch Screen |
| Printer | Built-In Thermal Printer |
| QC Levels | Up to 4 |
| QC Display | Levey-Jennings Graph |
| Functions | Self Diagnosis, Copy Test, Rerun |
| Plate Feeding | Automatic |
| Measurement | Automatic |
| Data Analysis | Automatic |
| Intended Use | Professional Laboratory Use |
After an ELISA assay is completed in a 96-well plate, the microplate is placed into the EIAQuant.
The instrument:
The exact wavelength, cut-off formula, calibration model and assay interpretation should be programmed according to the specific ELISA kit being used.
The EIAQuant can be used with compatible ELISA assays requiring microplate absorbance measurement.
Typical applications may include:
Assay compatibility depends on the wavelength, plate format and protocol specified by the reagent manufacturer.
The EIAQuant naturally complements Meril’s own ELISA range.
https://microsidd.com/products/merilisa-hiv-96t-pack
https://microsidd.com/products/merilisa-hcv-elisa-3-0-96t-pack
https://microsidd.com/products/merilisa-hbsag-96t-pack
https://microsidd.com/collections/elisa-range
Your ELISA collection currently includes Meril HIV, HCV and HBsAg products alongside other professional ELISA kits, so linking this reader into that collection will make the category significantly stronger. Microsidd India
The ELISA reader and ELISA washer perform different functions.
| Instrument | Main Function |
|---|---|
| ELISA Reader | Measures optical density / absorbance |
| ELISA Washer | Washes microplate wells between assay steps |
The reader interprets the final colour reaction, while the washer is used during the assay workflow to remove unbound reagents.
For a complete ELISA laboratory setup, both instruments may be required depending on the test protocol.
The Merilyzer EIAQuant is intended for trained laboratory professionals working in:
This is a professional laboratory instrument and is not intended for household or consumer self-testing.
The EIAQuant provides several practical benefits:
Quality-control monitoring is especially important in ELISA workflows.
The EIAQuant supports:
Up to 4 levels of control sera
with
Levey-Jennings graphical display
This helps laboratories monitor control trends and detect shifts or analytical variation during routine testing.
The EIAQuant can support quantitative ELISA workflows where the assay requires calibration curves.
The correct calibration model depends on the individual assay.
Laboratories should use the calibration approach specified by the ELISA kit manufacturer rather than applying a generic calculation.
For qualitative ELISA assays, the reader can process optical-density values and apply assay-specific cut-off calculations.
The instrument also supports grey-zone and reverse cut-off workflows where required by the programmed test method.
Interpretation should always follow the individual assay IFU.
A typical ELISA setup may include:
The instrument should be installed on a stable, clean laboratory bench away from:
Installation, calibration and commissioning should follow the manufacturer's instructions.
Only appropriately trained personnel should operate the reader.
Routine maintenance should follow Meril’s operating manual.
General laboratory practices include:
For transport or relocation:
Exact transport and operating conditions should follow the current manufacturer manual.
https://microsidd.com/collections/elisa-range
https://microsidd.com/collections/blood-bank-range
https://microsidd.com/collections/chemicals-liquids
Microsidd India supplies professional diagnostic equipment, laboratory reagents, ELISA kits and blood-bank products to healthcare and laboratory customers.
Benefits include:
✓ Genuine brand-specific laboratory equipment
✓ Meril ELISA kits available alongside the reader
✓ Dedicated ELISA collection
✓ Blood-bank and laboratory reagents available
✓ Technical product information before ordering
✓ Bengaluru-based support
✓ GST invoice where applicable
✓ Institutional supply support subject to availability
✓ Online ordering for serviceable locations across India
✓ Easier sourcing of compatible reagents and accessories from one supplier
Microsidd India supplies ELISA readers and professional diagnostic laboratory products in Bengaluru and serves laboratories across serviceable locations in India.
Professional buyers searching for:
ELISA reader Bangalore
microplate reader Bengaluru
Meril ELISA reader
96 well ELISA reader India
ELISA equipment near me
blood bank ELISA equipment Bangalore
order through Microsidd.com subject to stock and serviceability.
Business Name: Microsidd India
Address: #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India
Phone / WhatsApp: +91 63667 72288
Email: support@microsidd.com
Website: https://microsidd.com
Working Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST
For laboratory product videos, diagnostic guides and product explainers:
https://www.youtube.com/channel/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1
For updates about new diagnostic products, laboratory equipment and offers:
https://whatsapp.com/channel/0029Va5lCoi1nozBZBL1gx3P
It is a professional 96-well ELISA microplate reader used to measure absorbance in ELISA and compatible microplate assays. Meril Life
It is designed for 96-well microtiter plates.
The standard filters are:
405 nm, 450 nm, 492 nm and 630 nm.
Yes. The instrument has three optional filter positions.
Yes. It supports both monochromatic and bichromatic reading.
Meril lists approximately 6.5 seconds at single wavelength and 16 seconds at dual wavelength.
The instrument supports a 0–4.0 OD dynamic range.
Yes. It includes a built-in thermal printer.
Yes. It uses a large interactive LCD touch screen.
Yes. It supports up to four levels of control sera with Levey-Jennings graphing.
Yes, if the HIV ELISA assay uses compatible wavelengths and a 96-well plate.
Yes, subject to assay compatibility and programming.
Yes, subject to the assay IFU and wavelength requirements.
Yes, where the assay requires absorbance-based quantitative calculation and the appropriate calibration model is programmed.
Yes.
Yes. Meril describes automatic measurement, data analysis and processing.
Yes. Self Diagnosis is one of the listed functions.
The instrument includes a Rerun option.
No. It is professional laboratory equipment.
No. Plate washing is normally performed with an ELISA washer or validated manual washing process.
Yes.
Browse: https://microsidd.com/collections/elisa-range
Yes. https://microsidd.com/collections/blood-bank-range
This product is non-returnable and non-exchangeable, has 2 years warranty
Please verify the brand, model, application, wavelength requirements, plate compatibility, assay requirements, instrument specifications and installation requirements before placing your order.
For laboratory equipment, customers should specifically verify the required test methodology, compatible ELISA kit, wavelength, plate format, laboratory infrastructure and intended workflow before ordering.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
The Meril Merilyzer EIAQuant is intended for professional laboratory use.
The instrument must be installed, operated, calibrated and maintained by appropriately trained personnel according to the manufacturer’s current operating instructions, laboratory SOPs, quality-control procedures and applicable regulatory requirements.
Test results depend on the performance of the complete analytical system, including the assay kit, specimen quality, instrument programming, wavelength selection, calibration, QC and laboratory procedure.
Clinical decisions should not be based solely on an instrument reading without appropriate assay validation and professional interpretation.
| Specification name | Specification Value |
|---|---|
| Color pattern | White |