MERIL DIAGNOSTICS

Meril Merilyzer EIAQuant ELISA Microplate Reader – 96 Well

Limited-Time Offer on checkout

00 d

:

00 h

:

00 m

Sale price Rs. 159,000.00 Regular price Rs. 320,000.00
50% off
Tax included. Shipping calculated at checkout.
SKU: Meril EIA Reader
Expiry Date: 2 Year Warranty
No Return / No Exchange
This product is non-returnable and non-exchangeable.
View policy details

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Pairs well with

Meril EIAQuant ELISA Reader 96 Well | Microsidd India
Rs. 159,000.00

Compact ELISA Reader for Professional Diagnostic Laboratories

The Meril Merilyzer EIAQuant ELISA Microplate Reader is a professional laboratory instrument designed for photometric reading of 96-well microtiter plates used in ELISA and other absorbance-based microplate assays.

The system is designed for laboratories that require a compact ELISA reader with automated plate feeding, absorbance measurement, result calculation, data processing, quality-control support and built-in printing.

With standard wavelengths of 405 nm, 450 nm, 492 nm and 630 nm, monochromatic and bichromatic reading modes, fast plate-reading capability and an interactive LCD touch screen, the EIAQuant is suitable for diagnostic laboratories, blood banks, hospital laboratories, serology departments and other professional ELISA workflows.

Product Information

Brand: Meril Diagnostics
Product Name: Merilyzer EIAQuant
Product Type: ELISA Microplate Reader
Category: Laboratory Instruments
Subcategory: ELISA Reader / Microplate Reader
Plate Format: 96-Well Microtiter Plate
Measurement: Absorbance / Optical Density
Standard Wavelengths: 405 nm, 450 nm, 492 nm, 630 nm
Additional Filter Positions: 3 Optional Positions
Reading Modes: Monochromatic and Bichromatic
Single-Wavelength Reading Speed: Approx. 6.5 Seconds
Dual-Wavelength Reading Speed: Approx. 16 Seconds
Optical Density Range: 0–4.0 OD
Light Source: Halogen
Optical System: Eight-Channel Fibre Optics
Display: Large Interactive LCD Touch Screen
Printer: Built-In Thermal Printer
QC: Up to 4 Levels of Control Sera with Levey-Jennings Graph
Functions: Self Diagnosis, Copy Test, Rerun, Automatic Feeding, Automatic Measurement, Data Analysis and Processing
Intended Use: Professional Laboratory Use
Suitable Users: Diagnostic laboratories, blood banks, hospital laboratories, serology laboratories, research and clinical laboratories
Seller: Microsidd India
Location: RT Nagar, Bengaluru, Karnataka

What Is Merilyzer EIAQuant?

The Merilyzer EIAQuant is a compact ELISA microplate reader used to measure the absorbance of samples processed in a 96-well microtiter plate.

It is designed for laboratories performing qualitative and quantitative enzyme immunoassays where optical-density measurement is required.

The instrument automates several parts of the reading workflow, including:

  • plate feeding
  • absorbance measurement
  • data processing
  • result analysis
  • QC review
  • report printing

This makes it suitable for laboratories running routine ELISA assays for infectious disease, hormones and other compatible parameters.

Key Features

Four Standard Wavelength Filters

The EIAQuant includes four standard spectral filters:

405 nm
450 nm
492 nm
630 nm

The system also provides three optional filter positions for additional assay requirements.

Monochromatic & Bichromatic Reading

The instrument supports both:

Monochromatic reading

and

Bichromatic reading

allowing laboratories to select the reading mode required by the assay protocol.

Fast Plate Reading

Meril lists the reading speed as approximately:

6.5 seconds at single wavelength

and

16 seconds at dual wavelength

for a compatible microplate.

0–4.0 OD Dynamic Range

The instrument supports an optical-density range of 0 to 4.0 OD, providing a broad absorbance measurement range for compatible ELISA assays.

Eight-Channel Fibre-Optic System

The EIAQuant uses an eight-channel fibre-optic optical system, allowing efficient microplate reading.

Halogen Light Source

A halogen light source is used for absorbance measurement.

Interactive Touch Screen

A large LCD touch screen provides direct instrument control and easier laboratory operation.

Built-In Thermal Printer

The integrated thermal printer allows laboratories to generate results without requiring a separate external printer for routine reporting.

Built-In Quality Control

The EIAQuant supports up to four levels of control sera with a Levey-Jennings graph, helping laboratories monitor assay performance.

Self-Diagnosis Function

The system includes built-in self-diagnostic functionality to support routine instrument checks.

Copy Test & Rerun Functions

The instrument includes convenient workflow features such as:

Copy Test

and

Rerun

for repeat or related assay processing.

Technical Specifications

Specification Details
Brand Meril Diagnostics
Model Merilyzer EIAQuant
Instrument Type ELISA Microplate Reader
Plate Format 96-Well Microtiter Plate
Measurement Absorbance / Optical Density
Standard Filters 405, 450, 492, 630 nm
Optional Filter Positions 3
Reading Modes Monochromatic / Bichromatic
Single-Wavelength Speed Approx. 6.5 sec
Dual-Wavelength Speed Approx. 16 sec
OD Range 0–4.0 OD
Light Source Halogen
Optical System Eight-Channel Fibre Optics
Display Large LCD Touch Screen
Printer Built-In Thermal Printer
QC Levels Up to 4
QC Display Levey-Jennings Graph
Functions Self Diagnosis, Copy Test, Rerun
Plate Feeding Automatic
Measurement Automatic
Data Analysis Automatic
Intended Use Professional Laboratory Use

How the ELISA Reader Works

After an ELISA assay is completed in a 96-well plate, the microplate is placed into the EIAQuant.

The instrument:

  1. feeds the plate into the optical system,
  2. reads absorbance at the selected wavelength,
  3. measures each well,
  4. processes the optical-density data,
  5. applies the programmed test calculation,
  6. generates qualitative or quantitative results according to the configured assay,
  7. displays or prints the final report.

The exact wavelength, cut-off formula, calibration model and assay interpretation should be programmed according to the specific ELISA kit being used.

Compatible ELISA Applications

The EIAQuant can be used with compatible ELISA assays requiring microplate absorbance measurement.

Typical applications may include:

  • HIV ELISA
  • HCV ELISA
  • HBsAg ELISA
  • Dengue ELISA
  • Thyroid ELISA
  • Hormone ELISA
  • Infectious-disease ELISA
  • Serology assays
  • Quantitative immunoassays
  • Qualitative ELISA screening

Assay compatibility depends on the wavelength, plate format and protocol specified by the reagent manufacturer.

Compatible Meril ELISA Kits

The EIAQuant naturally complements Meril’s own ELISA range.

Meril MeriLisa HIV ELISA – 96 Tests

https://microsidd.com/products/merilisa-hiv-96t-pack

Meril MeriLisa HCV ELISA 3.0 – 96 Tests

https://microsidd.com/products/merilisa-hcv-elisa-3-0-96t-pack

Meril MeriLisa HBsAg ELISA – 96 Tests

https://microsidd.com/products/merilisa-hbsag-96t-pack

Explore the Full ELISA Range

https://microsidd.com/collections/elisa-range

Your ELISA collection currently includes Meril HIV, HCV and HBsAg products alongside other professional ELISA kits, so linking this reader into that collection will make the category significantly stronger. Microsidd India

ELISA Reader vs ELISA Washer

The ELISA reader and ELISA washer perform different functions.

Instrument Main Function
ELISA Reader Measures optical density / absorbance
ELISA Washer Washes microplate wells between assay steps

The reader interprets the final colour reaction, while the washer is used during the assay workflow to remove unbound reagents.

For a complete ELISA laboratory setup, both instruments may be required depending on the test protocol.

Who Can Use This Instrument?

The Merilyzer EIAQuant is intended for trained laboratory professionals working in:

  • Diagnostic laboratories
  • Blood banks
  • Hospital laboratories
  • Serology laboratories
  • Clinical microbiology laboratories
  • Pathology laboratories
  • Medical colleges
  • Research laboratories
  • Institutional laboratories
  • Public-health laboratories
  • Transfusion-medicine laboratories

This is a professional laboratory instrument and is not intended for household or consumer self-testing.

Benefits for Diagnostic Laboratories

The EIAQuant provides several practical benefits:

  • compact laboratory footprint
  • 96-well microplate reading
  • fast reading times
  • built-in printer
  • touch-screen operation
  • automatic plate feeding
  • automatic measurement
  • automated data analysis
  • built-in QC functionality
  • Levey-Jennings QC graphing
  • monochromatic and bichromatic reading
  • multiple filter options
  • wide optical-density range

Quality Control Features

Quality-control monitoring is especially important in ELISA workflows.

The EIAQuant supports:

Up to 4 levels of control sera

with

Levey-Jennings graphical display

This helps laboratories monitor control trends and detect shifts or analytical variation during routine testing.

Calibration & Quantitative Testing

The EIAQuant can support quantitative ELISA workflows where the assay requires calibration curves.

The correct calibration model depends on the individual assay.

Laboratories should use the calibration approach specified by the ELISA kit manufacturer rather than applying a generic calculation.

Qualitative Testing & Cut-Off Analysis

For qualitative ELISA assays, the reader can process optical-density values and apply assay-specific cut-off calculations.

The instrument also supports grey-zone and reverse cut-off workflows where required by the programmed test method.

Interpretation should always follow the individual assay IFU.

Laboratory Setup Requirements

A typical ELISA setup may include:

  • Merilyzer EIAQuant reader
  • ELISA microplate washer
  • calibrated micropipettes
  • disposable pipette tips
  • ELISA reagent kits
  • incubator where required
  • refrigerator for reagent storage
  • centrifuge where required
  • timer
  • laboratory computer if external data management is used
  • appropriate PPE

Installation & Operation

The instrument should be installed on a stable, clean laboratory bench away from:

  • direct sunlight
  • excessive vibration
  • moisture
  • dust
  • extreme temperature variation

Installation, calibration and commissioning should follow the manufacturer's instructions.

Only appropriately trained personnel should operate the reader.

Cleaning & Maintenance

Routine maintenance should follow Meril’s operating manual.

General laboratory practices include:

  • keep the instrument clean and dry
  • avoid reagent spills inside the plate chamber
  • clean external surfaces appropriately
  • use only recommended service procedures
  • avoid unauthorised disassembly
  • periodically verify instrument performance
  • perform preventive maintenance according to the manufacturer schedule

Storage & Transportation

For transport or relocation:

  • use the original protective packaging where available
  • protect the instrument from impact and vibration
  • keep it dry
  • avoid extreme temperature exposure
  • transport in the correct orientation
  • allow the instrument to acclimatise before operation after significant temperature changes
  • perform verification after installation or relocation

Exact transport and operating conditions should follow the current manufacturer manual.

Explore Related Microsidd Collections

ELISA Range

https://microsidd.com/collections/elisa-range

Blood Bank Range

https://microsidd.com/collections/blood-bank-range

Laboratory Reagents & Kits

https://microsidd.com/collections/chemicals-liquids

Why Buy Meril EIAQuant from Microsidd?

Microsidd India supplies professional diagnostic equipment, laboratory reagents, ELISA kits and blood-bank products to healthcare and laboratory customers.

Benefits include:

✓ Genuine brand-specific laboratory equipment
✓ Meril ELISA kits available alongside the reader
✓ Dedicated ELISA collection
✓ Blood-bank and laboratory reagents available
✓ Technical product information before ordering
✓ Bengaluru-based support
✓ GST invoice where applicable
✓ Institutional supply support subject to availability
✓ Online ordering for serviceable locations across India
✓ Easier sourcing of compatible reagents and accessories from one supplier

Buy ELISA Reader in Bangalore / Bengaluru

Microsidd India supplies ELISA readers and professional diagnostic laboratory products in Bengaluru and serves laboratories across serviceable locations in India.

Professional buyers searching for:

ELISA reader Bangalore
microplate reader Bengaluru
Meril ELISA reader
96 well ELISA reader India
ELISA equipment near me
blood bank ELISA equipment Bangalore

order through Microsidd.com subject to stock and serviceability.

Microsidd India – NAP

Business Name: Microsidd India
Address: #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India
Phone / WhatsApp: +91 63667 72288
Email: support@microsidd.com
Website: https://microsidd.com
Working Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST

Find Microsidd India on Google Maps

https://www.google.com/maps/search/?api=1&query=Microsidd+India%2C+09+Green+Chambers%2C+14th+Cross%2C+RT+Nagar%2C+Bengaluru+560032

Stay Connected with Microsidd

Subscribe to Microsidd on YouTube

For laboratory product videos, diagnostic guides and product explainers:

https://www.youtube.com/channel/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1

Follow the Microsidd WhatsApp Channel

For updates about new diagnostic products, laboratory equipment and offers:

https://whatsapp.com/channel/0029Va5lCoi1nozBZBL1gx3P

Frequently Asked Questions

What is the Meril Merilyzer EIAQuant?

It is a professional 96-well ELISA microplate reader used to measure absorbance in ELISA and compatible microplate assays. Meril Life

What plate size does it support?

It is designed for 96-well microtiter plates. 

Which wavelengths are included?

The standard filters are:

405 nm, 450 nm, 492 nm and 630 nm. 

Are additional filters available?

Yes. The instrument has three optional filter positions. 

Does it support dual-wavelength reading?

Yes. It supports both monochromatic and bichromatic reading. 

What is the reading speed?

Meril lists approximately 6.5 seconds at single wavelength and 16 seconds at dual wavelength. 

What is the optical-density range?

The instrument supports a 0–4.0 OD dynamic range. 

Does it have a built-in printer?

Yes. It includes a built-in thermal printer. 

Does it have a touch screen?

Yes. It uses a large interactive LCD touch screen. 

Does it support quality control?

Yes. It supports up to four levels of control sera with Levey-Jennings graphing. 

Can it be used for HIV ELISA?

Yes, if the HIV ELISA assay uses compatible wavelengths and a 96-well plate.

Can it be used for HCV ELISA?

Yes, subject to assay compatibility and programming.

Can it be used for HBsAg ELISA?

Yes, subject to the assay IFU and wavelength requirements.

Can it be used for quantitative ELISA?

Yes, where the assay requires absorbance-based quantitative calculation and the appropriate calibration model is programmed.

Can it be used for qualitative ELISA?

Yes.

Does the instrument automatically analyse data?

Yes. Meril describes automatic measurement, data analysis and processing. 

Does it include self-diagnosis?

Yes. Self Diagnosis is one of the listed functions. 

Can the test be rerun?

The instrument includes a Rerun option. 

Is this product for home use?

No. It is professional laboratory equipment.

Does an ELISA reader perform washing?

No. Plate washing is normally performed with an ELISA washer or validated manual washing process.

Does Microsidd also supply ELISA kits?

Yes.

Browse: https://microsidd.com/collections/elisa-range

Does Microsidd supply blood-bank products?

Yes. https://microsidd.com/collections/blood-bank-range

No Return / No Exchange Policy

This product is non-returnable and non-exchangeable, has 2 years warranty 

Please verify the brand, model, application, wavelength requirements, plate compatibility, assay requirements, instrument specifications and installation requirements before placing your order.

For laboratory equipment, customers should specifically verify the required test methodology, compatible ELISA kit, wavelength, plate format, laboratory infrastructure and intended workflow before ordering.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Professional / Laboratory Disclaimer

The Meril Merilyzer EIAQuant is intended for professional laboratory use.

The instrument must be installed, operated, calibrated and maintained by appropriately trained personnel according to the manufacturer’s current operating instructions, laboratory SOPs, quality-control procedures and applicable regulatory requirements.

Test results depend on the performance of the complete analytical system, including the assay kit, specimen quality, instrument programming, wavelength selection, calibration, QC and laboratory procedure.

Clinical decisions should not be based solely on an instrument reading without appropriate assay validation and professional interpretation.

Product specifications table