Peerless FIAflex™ Reagent Packs are professional in-vitro diagnostic assay kits designed for use with the FIAflex™ Time-Resolved Fluorescence Immunoassay (TR-FIA) Analyzer.
The FIAflex system combines a compact fluorescence immunoassay analyser with parameter-specific reagent packs covering cardiac markers, coagulation, thyroid function, diabetes, renal markers, inflammation, fertility and Vitamin D.
Each currently listed Microsidd FIAflex reagent variant contains 25 tests.
Analyzer compatibility is essential. These reagent packs are intended for the compatible FIAflex platform and should not be assumed compatible with another FIA / immunofluorescence analyser.
Need the instrument? View the Peerless FIAflex Fluorescence Immunoassay Analyzer →
FIAflex is based on Time-Resolved Fluorescence Immunoassay (TR-FIA) technology using Europium-ion fluorescent particles.
Europium fluorescence has a comparatively long lifetime, allowing the analyser to measure the assay signal after much of the short-lived background fluorescence has decayed.
This approach helps improve signal-to-background performance and supports quantitative measurement across compatible FIAflex assays.
By using different reagent packs on the same FIAflex analyser, laboratories can expand their available test menu without purchasing a separate analyser for every individual parameter.
| Category | FIAflex Test | Pack | Catalogue No. |
|---|---|---|---|
| Cardiac Markers | cTnI FIA Test | 25 Tests | F131-40111 |
| CK-MB FIA Test | 25 Tests | F131-40211 | |
| Myoglobin FIA Test | 25 Tests | F131-40311 | |
| NT-proBNP FIA Test | 25 Tests | F131-40511 | |
| cTnI / CK-MB / Myoglobin Combo FIA Test | 25 Tests | F131-40611 | |
| Coagulation | D-Dimer FIA Test | 25 Tests | F131-40411 |
| Thyroid Function | TSH FIA Test | 25 Tests | F131-20111 |
| T3 FIA Test | 25 Tests | F131-20211 | |
| T4 FIA Test | 25 Tests | F131-20311 | |
| Diabetes & Renal | HbA1c FIA Test | 25 Tests | F131-30111 |
| Microalbumin FIA Test | 25 Tests | F131-30221 | |
| Inflammation / Infection Markers | CRP FIA Test | 25 Tests | F131-50111 |
| Procalcitonin – PCT FIA Test | 25 Tests | F131-50211 | |
| IL-6 FIA Test | 25 Tests | F131-50311 | |
| Fertility | β-hCG FIA Test | 25 Tests | F131-21011 |
| Vitamin / Bone Metabolism | Vitamin D FIA Test | 25 Tests | F131-90111 |
The FIAflex cardiac test menu currently includes:
These assays provide laboratories with multiple cardiac-marker options on the same FIAflex platform.
Cardiac-marker results must always be interpreted by qualified healthcare professionals together with the patient's history, clinical presentation, ECG and other appropriate investigations.
The D-Dimer FIA Test extends the FIAflex menu into professional coagulation-related laboratory testing.
Use only the specimen type, sample volume, reaction time, reference information and interpretation criteria defined in the current D-Dimer FIA package insert.
The current thyroid-function reagent range includes:
This allows laboratories using FIAflex to perform multiple thyroid-related immunoassays through one compact analyser platform.
FIAflex also supports professional laboratory testing for:
These assays use different specimen requirements, so laboratory staff must select and handle specimens according to the individual assay Instructions for Use.
The current FIAflex inflammation-marker menu includes:
These are laboratory measurements. No single result should be interpreted independently as confirmation or exclusion of infection, inflammation, sepsis or another medical condition.
The β-hCG FIA Test provides an additional quantitative immunoassay option on the FIAflex platform.
Use and interpretation must follow the current assay-specific instructions and professional clinical context.
The Vitamin D FIA Test expands FIAflex into professional Vitamin D testing using compatible specimens and the manufacturer's validated FIA procedure.
Sample requirements and analytical interpretation must be taken from the current Vitamin D FIA package insert.
These reagent packs form part of the same FIAflex diagnostic platform as the Peerless FIAflex Fluorescence Immunoassay Analyzer.
The analyser uses Time-Resolved Fluorescence Immunoassay technology with Europium-ion fluorescent particles.
The FIAflex instrument also supports:
Do not use FIAflex reagent packs with another FIA analyser unless written manufacturer documentation specifically confirms compatibility.
The exact analytical procedure differs between parameters, but the general FIAflex workflow involves:
This is a general system overview and not a substitute for the package insert supplied with each individual test.
The FIAflex assay family includes tests that may use:
Do not assume that every FIAflex test accepts every specimen type.
For example, the specimen accepted by a cardiac marker assay may differ from an HbA1c, thyroid, Vitamin D or Microalbumin assay.
Always verify the exact specimen requirement before collection and testing.
For professional specimen collection products, browse the Microsidd Blood Collection Tubes Collection.
FIAflex assays are designed for relatively rapid professional immunoassay workflows, but individual reaction times vary by parameter.
The FIAflex analyser supports both Walk-Away and Read-Now workflow modes.
Always follow the reaction time stated in the current reagent-pack Instructions for Use. Reading a cassette too early or too late can affect assay validity.
The FIAflex analyser is designed with automatic calibration and automatic strip recognition according to Peerless FIAflex product literature.
This reduces manual assay identification steps and means laboratories do not need to manually handle a separate RFID card / ID chip as part of routine FIAflex testing.
Correct reagent identity, lot, expiry and instrument compatibility must nevertheless still be checked before testing.
Do not apply one generic storage rule to all FIAflex reagent packs.
Storage requirements, unopened stability and component handling can vary between assays.
Always verify:
If you need a specific minimum shelf life for institutional procurement, contact Microsidd before ordering.
Professional quantitative immunoassays require appropriate laboratory quality management.
Laboratories should maintain procedures covering:
Do not report results when required quality-control acceptance criteria are not satisfied.
FIAflex reagent packs are intended for professional facilities such as:
Fluorescence immunoassay cassettes are generally platform-specific products. A reagent with the same parameter name does not automatically mean it will operate correctly on a different FIA analyser.
| Buying Consideration | Microsidd FIAflex Listing | General Marketplace / Local Listing |
|---|---|---|
| Platform Compatibility | Clearly linked to the Peerless FIAflex analyser | Analyzer compatibility may not always be clearly described |
| Available Parameters | 16 current variants grouped on one product page | May be split among multiple sellers or listings |
| Catalogue Number | Specified for each assay variant | May not always be shown |
| Pack Size | 25 Tests clearly stated | Can vary between listings |
| Analyzer Availability | Compatible FIAflex analyser available on Microsidd | May require sourcing separately |
| Laboratory Product Range | Blood tubes, laboratory consumables and related equipment available | Depends on seller catalogue |
| GST Invoice | Available for eligible purchases | Seller dependent |
| Bengaluru Presence | RT Nagar, Bengaluru-based supplier | Depends on seller location |
| Institutional Requirements | Multiple-pack / laboratory procurement may be supported subject to stock | Seller dependent |
FIA reagents should be purchased by verifying the exact analyzer platform, parameter, catalogue number, pack size, specimen requirement and current expiry.
Microsidd India provides both the Peerless FIAflex analyser and compatible FIAflex reagent menu within the same specialist laboratory catalogue.
This helps laboratories review the instrument and its consumables together before making a procurement decision.
Also browse:
Microsidd India is a medical, diagnostic and laboratory-products supplier based in RT Nagar, Bengaluru.
Professional buyers searching for FIA reagent packs in Bangalore, Peerless FIAflex reagents Bengaluru, cTnI FIA reagent, D-Dimer FIA test, TSH FIA reagent, HbA1c fluorescence immunoassay, CRP FIA kit, PCT FIA reagent, IL-6 FIA test, Vitamin D FIA reagent or FIAflex test kits near RT Nagar can check current availability through Microsidd.com.
For laboratories purchasing multiple reagent packs, contact Microsidd to verify current stock, lot availability and remaining shelf life before placing a bulk order.
Business Name: Microsidd India
Address: #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India
Phone / WhatsApp: +91 63667 72288
Email: support@microsidd.com
Website: https://microsidd.com
Working Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST
View Microsidd India on Google Maps
For Bengaluru ordering information, visit Microsidd India – Medical & Laboratory Supplies Bangalore.
They are parameter-specific professional fluorescence immunoassay test kits designed for the Peerless FIAflex analyser.
FIAflex uses Time-Resolved Fluorescence Immunoassay technology with Europium-ion fluorescent particles.
The currently listed Microsidd FIAflex variants contain 25 tests per pack.
These packs are intended for use with the compatible Peerless FIAflex Fluorescence Immunoassay Analyzer.
Compatibility should not be assumed. Use these reagent packs only with a manufacturer-compatible FIAflex platform unless written documentation confirms otherwise.
Microsidd currently lists 16 FIAflex reagent variants.
cTnI, CK-MB, Myoglobin, NT-proBNP and cTnI / CK-MB / Myoglobin Combo FIA tests are currently listed.
Yes. A D-Dimer FIA 25-test pack is currently listed.
Current variants include TSH, T3 and T4 FIA tests.
Yes. An HbA1c FIA 25-test reagent pack is currently available as a selectable variant.
Yes. FIAflex Microalbumin is included in the current reagent menu.
Yes. Both CRP and Procalcitonin FIA reagent packs are currently listed.
Yes. An IL-6 FIA 25-test variant is currently listed.
Yes. β-hCG is included in the current FIAflex assay menu.
Yes. A Vitamin D FIA reagent pack is currently listed.
No. Specimen requirements vary between parameters and may include whole blood, serum, plasma or urine depending on the assay.
No. Sample volume is assay-specific. Follow the Instructions for Use supplied with the selected test.
No. Reaction time varies by parameter. Use the exact timing stated in the current assay package insert.
Peerless describes the FIAflex platform as using automatic calibration and automatic strip recognition without the need for a separate RFID card / ID chip in routine testing.
Storage requirements can vary by assay. Check the current reagent label and package insert for the exact parameter purchased.
Expiry is batch-specific. Customers requiring a particular minimum shelf life should contact Microsidd before ordering.
No. They are intended for professional in-vitro diagnostic testing by appropriately trained personnel.
Yes. Microsidd lists both the FIAflex analyser and its current compatible reagent menu.
Peerless FIAflex reagent packs can be ordered through Microsidd.com subject to stock. Microsidd India is based in RT Nagar, Bengaluru.
Institutional and multiple-pack requirements may be supported subject to current inventory, batch availability, required shelf life and commercial terms.
Peerless FIAflex reagent packs are professional in-vitro diagnostic products intended for appropriately trained laboratory and healthcare personnel.
Information on this product page is provided for product identification, procurement and general educational purposes. It does not replace:
Analytical results must not be interpreted independently as a diagnosis. Results should be assessed by qualified professionals together with clinical information, applicable reference intervals, assay limitations, quality-control status and other investigations where required.
If the current manufacturer label or package insert differs from general information displayed online, the current manufacturer documentation supplied with the reagent pack takes precedence.
FIAflex diagnostic reagent packs are non-returnable and non-exchangeable once correctly supplied.
Please verify before ordering:
Ordering the wrong assay, parameter, catalogue number or analyzer-incompatible reagent is not considered a product defect where the supplied item matches the confirmed order.
Diagnostic kits and reagent packs can be affected by storage conditions, temperature, contamination and handling after delivery. Correctly supplied products therefore cannot normally be accepted back into saleable inventory.
Genuine cases involving incorrect supply, verified transit damage, materially misdescribed goods or other remedies required under applicable law will be handled according to the Microsidd Refund, Return, Replacement & Cancellation Policy.
An original, continuous, unedited and uncut unboxing video is compulsory for delivery-related claims involving an incorrect, missing or damaged product.
The recording must begin before opening the shipment. Open the outer package carefully by cutting the sealing tape with a blade or suitable cutter; do not tear open the carton. Keep the courier label, sealed pack, reagent-box labels and product condition continuously visible while opening.
Product: FIAflex Reagent Packs
Brand: Peerless
Platform: FIAflex™
Technology: Time-Resolved Fluorescence Immunoassay (TR-FIA)
Pack Size: 25 Tests per Current Variant
Current Number of Variants: 16
Categories: Cardiac, Coagulation, Thyroid, Diabetes, Renal, Inflammation, Fertility & Vitamin D
Compatible Instrument: Peerless FIAflex Fluorescence Immunoassay Analyzer
Use: Professional In-Vitro Diagnostic Use
Typical Users: Diagnostic Laboratories, Hospitals, Emergency Departments & Professional POCT Environments
Supplier: Microsidd India
Supplier Location: RT Nagar, Bengaluru, Karnataka, India
| Specification name | Specification Value |
|---|---|
| Chemical grade | Laboratory |
| Color pattern | White |