The Erba Creatinine CREA 275 Reagent System Pack is a professional clinical chemistry reagent designed for the quantitative determination of creatinine using the established Jaffe method.
Erba identifies this dedicated system reagent as CREA 275, catalogue number XSYS0024. The official pack configuration contains R1: 5 × 44 ml and R2: 5 × 11 ml.
According to Erba's current clinical chemistry reagent catalogue, CREA 275 is designed for compatible Erba XL clinical chemistry analysers and provides approximately 1,600 tests per kit, subject to analyser configuration, calibration, quality-control usage and routine laboratory workflow.
| Product | Creatinine Reagent |
| Brand | Erba Mannheim |
| Pack Name | CREA 275 |
| Catalogue Number | XSYS0024 |
| R1 Pack | 5 × 44 ml |
| R2 Pack | 5 × 11 ml |
| Method | Jaffe |
| Reagent Type | Liquid Stable / Ready to Use |
| Pack Type | Erba SYSPACK™ |
| Manufacturer-Listed Tests / Kit | Approximately 1,600 |
| Analyser Platform | Compatible Erba XL Clinical Chemistry Analysers |
| Clinical Category | Renal Function / Clinical Chemistry |
| Intended Use | Professional In-Vitro Diagnostic Use |
| Seller | Microsidd India |
| Location | Bangalore / Bengaluru, Karnataka, India |
The Jaffe method is a widely used clinical chemistry method for quantitative creatinine determination.
Creatinine reacts with picrate under alkaline conditions to produce a coloured complex. The change in absorbance is related to the creatinine concentration in the specimen.
The exact analyser wavelength, timing, reagent volumes, sample volume, calibration settings and application parameters should always be taken from the current Erba Instructions for Use and analyser application supplied for the actual reagent lot.
Erba SYSPACK™ reagents are dedicated reagent packs developed for use with compatible Erba XL clinical chemistry analysers.
The system-pack format helps support:
| Component | Pack Configuration |
|---|---|
| Creatinine Reagent R1 | 5 × 44 ml |
| Creatinine Reagent R2 | 5 × 11 ml |
| Erba XL Platform | Manufacturer-Listed Tests / Kit |
|---|---|
| Erba XL-180 | Approximately 1,600 tests |
| Erba XL-200 | Approximately 1,600 tests |
| Erba XL-640 | Approximately 1,600 tests |
| Erba XL-1000 | Approximately 1,600 tests |
Actual usable test yield can vary according to calibration frequency, internal quality-control runs, repeats, analyser dead volume and laboratory workflow.
CREA 275 is designed for compatible analysers within the Erba XL clinical chemistry family.
Always confirm compatibility with the exact analyser model, application software and current manufacturer documentation before routine use.
Creatinine is a metabolic waste product formed mainly from normal muscle metabolism and is eliminated predominantly through the kidneys.
Creatinine testing is widely used as part of:
Creatinine is commonly interpreted together with other renal markers and may also contribute to calculated kidney-function estimates such as eGFR, depending on the laboratory's reporting system and applicable clinical formula.
| Parameter | General Laboratory Role |
|---|---|
| Creatinine | Renal filtration-related biochemical marker |
| Urea | Protein metabolism and renal excretion |
| Uric Acid | Purine metabolism and renal excretion |
| Sodium | Fluid and electrolyte balance |
| Potassium | Electrolyte and renal balance |
| Chloride | Fluid and acid-base balance |
| Buyer Type | Typical Application |
|---|---|
| Pathology Laboratories | Routine creatinine testing |
| Diagnostic Centres | RFT and renal profiles |
| Hospital Laboratories | Automated clinical chemistry |
| Nephrology Centres | Renal investigations |
| Dialysis Centres | Renal chemistry monitoring |
| Diabetes Centres | Renal profile assessment |
| Clinical Chemistry Laboratories | High-volume creatinine testing |
| Healthcare Institutions | Institutional laboratory procurement |
Browse the dedicated Erba Lab Reagents Collection at Microsidd.com for Erba Mannheim clinical chemistry system packs and related professional laboratory reagents.
The Erba collection currently includes products such as:
This product should be linked reciprocally from the Erba collection to strengthen brand-level navigation and help laboratories compare compatible Erba XL system reagents.
Browse the broader Biochemistry Reagents Collection for renal, liver, lipid, electrolyte and other clinical chemistry reagents from multiple diagnostic brands.
For laboratories building a renal testing menu, also explore:
Microsidd India focuses on professional diagnostic, laboratory and IVD products and now maintains a dedicated Erba Lab Reagents collection for easier brand-specific procurement.
| Microsidd Advantage | Benefit for Laboratory Buyers |
|---|---|
| Dedicated Erba Collection | Easy access to Erba XL system reagents |
| Diagnostic / IVD Focus | Professional laboratory-oriented procurement |
| Clear Pack Identification | Product code, pack size and method shown before purchase |
| Technical Product Information | Helps laboratories confirm requirements before ordering |
| Related Clinical Chemistry Range | Easier multi-reagent procurement |
| GST Invoice | Available for eligible purchases |
| Bangalore-Based Operations | Convenient for Bengaluru and Karnataka laboratories |
| India-Wide Supply | Subject to stock and serviceability |
Microsidd India supplies Erba clinical chemistry reagents, renal-function reagents and professional laboratory products from Bangalore / Bengaluru, Karnataka.
The Erba CREA 275 Creatinine System Pack is designed for laboratories using compatible Erba XL chemistry analysers and requiring a dedicated Jaffe-method creatinine reagent system.
CREA 275 is Erba Mannheim's dedicated Creatinine SYSPACK reagent for compatible XL clinical chemistry analysers.
The manufacturer catalogue number is XSYS0024.
The manufacturer lists the method as Jaffe.
The official configuration is R1 5 × 44 ml + R2 5 × 11 ml.
Erba lists approximately 1,600 tests per kit on the compatible XL analyser platforms.
Yes. Erba SYSPACK reagents are designed as liquid-stable, ready-to-use system reagents.
Yes, subject to the current manufacturer application and analyser configuration.
This product should primarily be treated as a dedicated Erba XL system reagent. Use on another analyser should only be considered where specifically supported by manufacturer documentation and validated by the laboratory.
Visit the Erba Lab Reagents Collection on Microsidd.com.
No. This product is intended for professional in-vitro diagnostic laboratory use only.
The information on this page is provided for product identification, professional laboratory procurement and educational purposes only.
Creatinine results should not be interpreted independently to diagnose or exclude kidney disease. Results should be interpreted together with clinical history, eGFR where applicable, urea, electrolytes, urine findings and other relevant laboratory investigations.
Laboratories must follow the current Erba Mannheim Instructions for Use supplied with the actual reagent lot, including analyser application parameters, calibration, internal quality control, storage and analytical limitations.
This product is non-returnable and non-exchangeable.
Please verify the brand, reagent name, catalogue number, analyser compatibility, method and pack configuration before placing your order.
For this product, customers should specifically verify that they require Erba CREA 275 / XSYS0024 / Jaffe Method / R1 5 × 44 ml + R2 5 × 11 ml.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
| Specification name | Specification Value |
|---|---|
| Chemical grade | Laboratory, Reagent |
| Color pattern | White |