The Erba Alkaline Phosphatase (ALP) Reagent Kit is a professional clinical chemistry reagent designed for the quantitative determination of Alkaline Phosphatase enzyme activity.
Erba identifies the reagent as ALP 110 and uses the established IFCC, AMP method. The reagent system is designed for use with compatible Erba XL clinical chemistry analysers and is intended for professional in-vitro diagnostic laboratory use.
According to Erba Mannheim's current clinical chemistry catalogue, the ALP 110 SYSPACK contains R1: 2 × 44 ml and R2: 2 × 11 ml and provides approximately 500 tests on XL-180 / XL-200 / XL-640 systems and up to 640 tests on XL-1000, depending on analyser configuration and application settings.
| Product | Alkaline Phosphatase / ALP Reagent |
| Brand | Erba Mannheim |
| Erba Pack Name | ALP 110 |
| Method | IFCC, AMP |
| R1 Pack | 2 × 44 ml |
| R2 Pack | 2 × 11 ml |
| Assay Type | Clinical Chemistry Enzyme Assay |
| Reagent Format | Liquid Stable / Ready to Use |
| Analyser Category | Erba XL Clinical Chemistry Analysers |
| Intended Use | Professional In-Vitro Diagnostic Use |
| Seller | Microsidd India |
| Location | Bangalore / Bengaluru, Karnataka, India |
Alkaline Phosphatase (ALP) is an enzyme found in several tissues, particularly the liver, biliary system, bone, intestine and placenta.
ALP measurement is commonly included in routine clinical chemistry investigations and is frequently interpreted alongside other biochemical parameters such as:
An ALP result should not be interpreted alone to determine the source or cause of an abnormal enzyme level.
The Erba ALP 110 reagent uses the IFCC, AMP method for Alkaline Phosphatase measurement.
This methodology is designed for automated clinical chemistry workflows and allows measurement of ALP enzyme activity according to Erba's validated analyser application.
Erba's SYSPACK reagents are dedicated reagent packs designed for Erba XL clinical chemistry analysers.
Erba describes these reagents as:
| Component | Pack Configuration |
|---|---|
| Reagent R1 | 2 × 44 ml |
| Reagent R2 | 2 × 11 ml |
Always verify the reagent components and volumes printed on the physical product supplied to your laboratory.
| Analyser | Manufacturer-Listed Tests / Kit |
|---|---|
| Erba XL-180 / XL-200 / XL-640 | Approximately 500 tests |
| Erba XL-1000 | Approximately 640 tests |
Actual usable test yield can vary depending on analyser dead volume, calibration, quality-control frequency and laboratory workflow.
The ALP 110 system reagent is designed for compatible instruments in the Erba XL clinical chemistry analyser family, including systems such as:
Compatibility should always be confirmed against the exact analyser model, software application and current Erba reagent documentation before use.
Dedicated analyser reagent packs can simplify clinical chemistry workflows by providing reagent configurations developed specifically for the manufacturer's analyser platform.
Alkaline Phosphatase testing is commonly used as part of:
| Parameter | General Laboratory Role |
|---|---|
| ALT / SGPT | Hepatocellular-associated enzyme |
| AST / SGOT | Hepatic and extra-hepatic enzyme |
| Alkaline Phosphatase | Hepatobiliary and bone-associated enzyme |
| Bilirubin | Bilirubin metabolism |
| Albumin | Major circulating protein |
| Total Protein | Overall serum protein measurement |
Browse the complete Biochemistry Reagents Collection at Microsidd.com.
For laboratories building complete clinical chemistry profiles, also explore related reagents for: SGOT / AST, SGPT / ALT, Bilirubin, Albumin, Total Protein, Calcium and Phosphorus.
As the Erba range expands on Microsidd.com, this product should also be linked reciprocally with the dedicated Erba brand collection and related Erba XL system reagents.
Microsidd India focuses on professional diagnostic, laboratory and IVD products, helping laboratories source clinical chemistry reagents from a specialist supplier rather than a general marketplace.
| Microsidd Advantage | Benefit for Laboratory Buyers |
|---|---|
| Diagnostic & IVD Specialisation | Focused laboratory-product procurement |
| Product Method Information | Helps verify reagent requirements before ordering |
| Pack Configuration Information | Reduces risk of ordering an incorrect reagent pack |
| Related Biochemistry Products | Convenient multi-reagent procurement |
| GST Invoice | Available for eligible purchases |
| Bangalore-Based Operations | Convenient for Bengaluru and Karnataka laboratories |
| India-Wide Supply | Subject to stock and serviceability |
Microsidd India supplies clinical chemistry reagents, liver-function reagents and laboratory diagnostic products from Bangalore / Bengaluru, Karnataka.
The Erba ALP 110 Alkaline Phosphatase Reagent Kit is suitable for professional laboratories using compatible Erba XL clinical chemistry systems.
It is used for quantitative determination of Alkaline Phosphatase enzyme activity in professional clinical chemistry laboratories.
The manufacturer lists the method as IFCC, AMP.
The official Erba system-pack listing specifies R1: 2 × 44 ml.
Yes. Erba's current official ALP 110 configuration lists R2: 2 × 11 ml in addition to R1 2 × 44 ml.
Erba describes its XL system reagents as liquid stable and ready to use.
Erba lists approximately 500 tests on XL-180 / XL-200 / XL-640 systems and approximately 640 tests on XL-1000, subject to analyser configuration and laboratory workflow.
Yes. ALP 110 is a dedicated Erba SYSPACK reagent intended for compatible Erba XL clinical chemistry analysers.
This listing should primarily be treated as an Erba XL system reagent. Use on any other analyser should only be considered where supported by manufacturer documentation and validated by the laboratory.
No. It is intended for professional in-vitro diagnostic laboratory use only.
The information on this page is provided for product identification, professional laboratory procurement and educational purposes only.
This product is intended for use by trained laboratory personnel. Alkaline Phosphatase results should not be interpreted independently to diagnose or exclude liver, biliary, bone, endocrine or other medical conditions.
Laboratories must follow the current Erba Mannheim Instructions for Use supplied with the actual reagent lot, including analyser-specific application settings, calibration, quality control, specimen requirements, storage and analytical limitations.
This product is non-returnable and non-exchangeable.
Please verify the brand, reagent name, analyser compatibility, pack configuration and product specifications before placing your order.
For this product, customers should specifically verify that they require Erba ALP 110 / Alkaline Phosphatase, IFCC AMP method and confirm the exact R1 and R2 configuration.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
| Specification name | Specification Value |
|---|---|
| Chemical grade | Laboratory, Reagent |
| Color pattern | Green |
| Test method | Lab analysis |
| Test sample | Blood |