Dr Trust USA Platinum Glucometer 9002 is a digital blood glucose monitoring system designed for routine blood sugar testing at home or under professional guidance.
The meter uses a small blood sample of approximately 0.5 µL and provides a result in approximately 5 seconds, according to the manufacturer's current product information.
Model 9002 features no-coding operation, automatic strip detection, automatic sample-loading detection, 4 testing modes, QC mode, reminder alarms, large LCD display, strip-ejection button, temperature warning and automatic power-off.
This listing includes the Dr Trust Platinum Glucometer 9002 with 10 test strips.
Brand: Dr Trust USA
Model: 9002
Product Type: Digital Blood Glucose Monitoring System
The Dr Trust 9002 requires approximately 0.5 µL of blood for a glucose test.
A small sample requirement can make routine finger-prick testing more convenient, especially for users who need to monitor glucose regularly.
Always use a fresh sterile lancet and follow the lancing-device instructions.
Once an adequate blood sample has been correctly applied to the compatible test strip, the meter displays the glucose reading after approximately 5 seconds.
Actual testing should follow the meter and strip instructions supplied with the current pack.
Dr Trust describes Model 9002 as a no-coding glucometer.
This eliminates the need to manually enter a code each time a new pack of compatible test strips is opened.
The meter includes four operating modes:
Used for routine blood glucose testing.
Intended to help mark readings taken before meals.
Intended to help mark readings taken after meals.
Designed for quality-control testing using the appropriate control solution and manufacturer procedure.
QC mode can help users verify meter and strip performance according to the supplied instructions.
Dr Trust states that the Platinum 9002 system uses GDH-FAD based test-strip technology.
The manufacturer describes this chemistry as designed to reduce interference associated with factors such as blood oxygen variation and certain sugars.
For accurate product selection, always use only the test-strip model specifically approved for the Dr Trust 9002 meter.
Test-strip compatibility should be verified carefully before reordering strips.
Dr Trust's current Model 9002 product page states that the meter should be used with Dr Trust test strips 9009.
However, Dr Trust's current Gold Standard strip listing identifies Model 9003 strips as compatible with meters 9001 and 9002.
Because the manufacturer's own current web pages are inconsistent, Microsidd recommends verifying the strip model printed on the test-strip vial / box supplied with your meter before purchasing replacement strips.
Do not purchase strips based only on visual similarity.
The meter is designed to detect:
This simplifies the testing workflow and reduces the number of manual steps.
The Dr Trust 9002 uses a large LCD screen designed to display glucose readings clearly.
The meter supports readings in:
Use the unit recommended by your healthcare provider and avoid switching units unintentionally.
The meter includes a visual indicator designed to make the displayed result easier to interpret.
The visual symbol is only a convenience feature and should not replace the actual numerical glucose reading or professional medical guidance.
Reminder alarms can be used to help users remember planned blood-glucose measurements.
This may be useful for people following a structured monitoring schedule recommended by a healthcare professional.
The built-in strip-ejection function allows a used strip to be removed without directly touching the blood-contact portion.
This can make disposal more convenient and hygienic.
Used strips and lancets should be discarded safely according to local sharps and biomedical-waste guidance.
Model 9002 includes a temperature-warning feature.
Testing outside the operating-temperature range specified by the manufacturer can affect meter or strip performance, so follow the storage and operating conditions provided with the current kit.
The manufacturer describes Model 9002 as including a blood-glucose related ketone warning / early-warning feature.
Important: this glucometer does not independently measure blood ketones unless a specific compatible ketone-testing system is provided and approved for that purpose.
A warning generated from a high glucose result should not be interpreted as a direct ketone measurement.
| Product | Platinum Blood Glucose Monitoring System |
| Brand | Dr Trust USA |
| Model | 9002 |
| Sample Volume | Approx. 0.5 µL |
| Result Time | Approx. 5 Seconds |
| Coding | No Coding Required |
| Testing Modes | General, AC, PC & QC |
| Strip Chemistry | GDH-FAD |
| Display | Large LCD |
| Units | mg/dL / mmol/L |
| QC Mode | Yes |
| Reminder Alarm | Yes |
| Strip Ejection | Yes |
| Auto Power-Off | Yes |
| Temperature Warning | Yes |
| Included Strips | 10 Test Strips |
| Warranty | 1 Year Manufacturer Warranty + Conditional Extended Warranty Registration |
The official Dr Trust product title currently describes the kit as including:
The product-detail section separately states “Gold Standard Glucose Monitor with 10 Strips.”
Because manufacturer packaging can be revised, verify the exact supplied components against the sealed box when received.
Model 9002 provides AC and PC tagging modes so users can organise readings according to meal timing.
The timing of pre-meal and post-meal testing should follow the monitoring plan provided by your healthcare professional.
QC mode is designed for use with the appropriate glucose control solution to check the meter and compatible strips.
Quality-control testing may be appropriate:
Use only the control solution and procedure specified for the system.
| Feature | Dr Trust 9002 | Laboratory Glucose Test |
|---|---|---|
| Use | Routine self-monitoring | Clinical laboratory measurement |
| Sample | Small blood sample | Laboratory specimen |
| Result Time | Approx. 5 seconds | Depends on laboratory workflow |
| Purpose | Monitoring glucose trends | Diagnosis / clinical assessment as ordered |
A home glucometer is useful for monitoring but should not replace laboratory testing or professional medical assessment when these are required.
Glucometers and test strips are model-specific compatibility products. A strip that looks similar may not work correctly with another meter.
| Buying Consideration | Microsidd India | General Marketplace / Local Market |
|---|---|---|
| Exact Brand | Dr Trust USA clearly identified | Generic meters may look similar |
| Exact Model | Model 9002 clearly stated | Model may be unclear |
| Pack Size | 10-strip starter configuration clearly stated | Bundle contents vary |
| Compatibility Guidance | Replacement-strip model should be verified before ordering | Seller dependent |
| GST Invoice | Available for eligible purchases | Seller dependent |
| Bengaluru Presence | RT Nagar, Bengaluru | Seller location varies |
Microsidd India supplies glucometers, compatible glucose test strips, lancets and diabetes-monitoring products from RT Nagar, Bengaluru.
Customers searching for Dr Trust Glucometer 9002 Bangalore, Platinum glucometer Bengaluru, blood sugar machine near me, glucose meter RT Nagar, Dr Trust sugar testing machine Bangalore or glucometer strips Bengaluru can check current availability through Microsidd.com.
Business Name: Microsidd India
Address: #09 Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India
Phone / WhatsApp: +91 63667 72288
Email: support@microsidd.com
Website: https://microsidd.com
Working Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST
View Microsidd India on Google Maps
This product is Dr Trust USA Platinum Glucometer Model 9002.
This listing includes 10 glucose test strips.
The manufacturer specifies approximately 0.5 µL.
The reading is displayed in approximately 5 seconds.
No. Model 9002 is described as a no-coding glucometer.
The meter has General, AC, PC and QC modes.
AC is used to mark a reading taken before a meal.
PC is used to mark a reading taken after a meal.
QC mode is intended for quality-control testing with the appropriate control solution.
Dr Trust specifies GDH-FAD based strip chemistry.
Verify the exact strip model printed on the vial supplied with your meter. Dr Trust's current webpages contain conflicting references to Models 9009 and 9003 for Model 9002, so replacement-strip compatibility should be checked before purchase.
Yes. A strip-ejection button allows the used strip to be removed without directly touching the blood-contact area.
Yes. Dr Trust states that readings may be displayed in mg/dL or mmol/L.
Yes. The manufacturer lists a reminder alarm function.
Dr Trust describes a ketone-related warning feature associated with high glucose readings. This should not be confused with a direct blood-ketone measurement.
Yes. Automatic power-off is included.
The current official product title states that 10 lancets and 1 lancing device are included, although the detailed “In the Box” line only explicitly states the meter with 10 strips. Verify actual sealed pack contents on receipt.
Dr Trust states a 1-year warranty plus an additional conditional extended-warranty programme requiring registration on the manufacturer website within 15 days.
Dr Trust Model 9002 can be ordered through Microsidd India, RT Nagar, Bengaluru, subject to stock availability.
Yes. Microsidd supplies diabetes-monitoring products to serviceable PIN codes across India, subject to stock and courier availability.
A glucometer is intended for blood-glucose monitoring and does not independently diagnose diabetes or determine medication changes.
Do not start, stop or change insulin, tablets or other treatment based solely on one home glucose result unless instructed by an appropriate healthcare professional.
If a reading is unexpectedly high or low:
Seek urgent medical attention for severe symptoms such as confusion, loss of consciousness, persistent vomiting, severe weakness or other signs of a medical emergency.
This is a personal-use healthcare device and a compatibility-sensitive test-strip system.
Please verify before ordering:
A correctly supplied product cannot normally be returned or exchanged because the wrong model was selected or incompatible replacement strips were purchased without verification.
Genuine cases involving incorrect supply, verified transit damage, materially misdescribed goods or remedies required under applicable law will be handled according to the Microsidd Refund, Return, Replacement & Cancellation Policy.
An original, continuous, unedited and uncut unboxing video is compulsory for claims involving an incorrect, missing or damaged product.
Begin recording before opening the parcel. Open the outer carton carefully by cutting the sealing tape with a blade or suitable cutter; do not tear the carton. Keep the courier label, sealed package, Dr Trust box, meter, strip vial, lancing device and accessories continuously visible.
Product: Digital Blood Glucose Monitoring System
Brand: Dr Trust USA
Series: Platinum
Model: 9002
Included Strips: 10
Sample Volume: Approx. 0.5 µL
Result Time: Approx. 5 Seconds
Coding: No Coding Required
Testing Modes: General, AC, PC & QC
Strip Chemistry: GDH-FAD
Display: Large LCD
Units: mg/dL / mmol/L
Reminder Alarm: Yes
Strip Ejector: Yes
Auto Power-Off: Yes
Temperature Warning: Yes
Warranty: 1 Year + Conditional Extended Warranty Registration, subject to terms
Seller: Microsidd India
Seller Location: RT Nagar, Bengaluru, Karnataka, India
| Specification name | Specification Value |
|---|---|
| Analyte measured | Glucose |
| Biometric monitor accessory features | Sugar % |
| Color pattern | White |
| Control type | Sensor |
| Display technology | LCD |
| Glucose measurement units | mg/dL (milligrams per deciliter) |
| Medical device certification | CE, FDA, ISO 13485 |
| Monitoring method | Finger-stick capillary blood |
| Power source | Battery-powered |