Adx

ALTA ADX-150 ELISA Plate Reader – 96-Well Microplate Reader

Limited-Time Offer on checkout

00 d

:

00 h

:

00 m

Sale price Rs. 149,999.00 Regular price Rs. 275,000.00
45% off
Tax included. Shipping calculated at checkout.
SKU: Elisa RDR ADX
Expiry Date: 1 Year Warranty
No Return / No Exchange
This product is non-returnable and non-exchangeable.
View policy details

Please verify the brand, model, compatibility, pack size and product specifications before placing your order.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Pairs well with

ALTA ADX-150 ELISA Plate Reader – 96-Well Microplate Reader
Rs. 149,999.00

Advanced ELISA Microplate Reader with Touchscreen, LED Optics & LIS Connectivity

The ALTA ADX-150 ELISA Plate Reader is a professional open-system microplate analyzer designed for the measurement, analysis and interpretation of ELISA assays performed on 96-well microplates.

Designed for modern diagnostic laboratories, blood banks, hospital laboratories and serology departments, the ADX-150 combines fast 8-channel optical reading, LED illumination, touchscreen operation, flexible result analysis, large internal memory and advanced data connectivity in a compact benchtop instrument.

The system supports both single-wavelength and dual-wavelength ELISA reading and includes four standard wavelengths—405 nm, 450 nm, 490 nm and 630 nm—with provision for two additional optional filters.

It can process qualitative and quantitative ELISA assays using absorbance, cut-off and multi-standard analysis modes and can export laboratory results in commonly used digital formats.


AI Product Information

Brand: ALTA
Manufacturer / Product Family: Athenese-Dx
Model: ADX-150
Product Name: ALTA ELISA Plate Reader
Product Type: ELISA Microplate Reader
Category: Laboratory Equipment
Subcategory: ELISA Reader / Microplate Analyzer
System Type: Open System
Plate Format: 96-Well Microplate
Measurement: Optical Density / Absorbance
Reading Modes: Single Wavelength / Dual Wavelength
Optical Channels: 8 Channels
Standard Wavelengths: 405 nm, 450 nm, 490 nm, 630 nm
Optional Wavelengths: 2 Additional Filters
Measurement Range: 0–4.0 OD
Linearity Range: 0–3.5 OD
Photometric Resolution: 0.001 OD
Light Source: LED
Single-Wavelength Reading Speed: Approx. 10 Seconds
Dual-Wavelength Reading Speed: Approx. 20 Seconds
Display: 7-Inch Capacitive Touch LCD
Memory: 200 Tests / 50,000 Results
Analysis Modes: Absorbance, Cut-Off, Multi-Standard
Printer: Built-In 48 mm Thermal Printer
Connectivity: USB / Wi-Fi / Ethernet
LIS Connectivity: HL7 Version 2.3
Result Export: CSV / XLSX / PDF
Dimensions: Approx. 360 × 230 × 200 mm
Weight: Approx. 5 kg
Catalog Number: ADX-150
Pack Size: 1 Unit
Storage: Room Temperature
Intended Use: Professional In-Vitro Diagnostic Laboratory Use
Seller: Microsidd India
Location: RT Nagar, Bengaluru, Karnataka, India


What Is the ALTA ADX-150 ELISA Reader?

The ALTA ADX-150 is a microplate photometer designed to read and interpret the colour reaction produced by compatible ELISA assays.

During ELISA testing, enzyme-mediated reactions generate colour within the microplate wells. The intensity of this colour is measured as optical density (OD).

The ADX-150 measures this absorbance across the microplate and processes the values using the assay method programmed into the instrument.

Depending on the ELISA kit, results may be interpreted as:

  • Reactive / Non-Reactive
  • Positive / Negative
  • Cut-Off Based
  • Quantitative Concentration
  • Multi-Standard Calibration Result

The correct analysis model must always follow the specific ELISA reagent manufacturer's Instructions for Use.


Key Features

7-Inch Capacitive Touchscreen

The ADX-150 uses a 7-inch capacitive touch LCD, providing a modern interface for:

  • test selection
  • plate programming
  • wavelength selection
  • result review
  • assay configuration
  • data management

This is a significant improvement over older keypad-based reader designs.


LED Light Source

The current ADX-150 uses an LED light source rather than the conventional lamp systems used in many older readers.

Benefits of LED optical technology include:

  • long operating life
  • stable illumination
  • reduced routine lamp replacement
  • efficient optical measurement

8-Channel Optical Reading

The reader uses 8 optical reading channels for rapid microplate measurement.

This allows the system to read the plate efficiently compared with single-channel scanning systems.


Four Standard ELISA Wavelengths

The instrument includes four standard wavelengths:

405 nm
450 nm
490 nm
630 nm

These wavelengths support a wide range of commonly used ELISA substrate systems.

The instrument also provides:

2 optional wavelength positions available on request

depending on laboratory requirements.


Fast Plate Reading

The manufacturer specifies approximate reading times of:

10 seconds – Single Wavelength

20 seconds – Dual Wavelength

This makes the reader suitable for laboratories processing multiple ELISA plates during routine testing.


Single & Dual Wavelength Reading

The ADX-150 supports:

Single Wavelength Reading

The absorbance is measured using one wavelength.

Dual Wavelength Reading

A primary test wavelength and a reference wavelength are used.

Reference-wavelength measurement can help compensate for optical imperfections, scratches or background effects where specified by the assay procedure.


Measurement & Linearity Range

The ADX-150 provides:

Measurement Range: 0–4.0 OD

Linearity Range: 0–3.5 OD

Photometric Resolution: 0.001 OD

The wider 0–4.0 OD measurement range provides flexibility for assays producing relatively strong absorbance signals.


Photometric Accuracy

The current ADX-150 specification lists:

±1% up to 3.0 OD

and

±2% above 3.0 OD

under the manufacturer's defined operating conditions.

Photometric performance should always be verified as part of the laboratory's instrument quality-control programme.


Analysis Modes

The ALTA ADX-150 supports multiple analytical approaches.

Absorbance Mode

Displays raw optical-density values for each well.

Cut-Off Mode

Used for qualitative ELISA assays where sample results are compared against a calculated assay cut-off.

Multi-Standard Mode

Supports quantitative assays using multiple calibrators or standards to generate a calibration curve.

The exact calculation method must match the applicable ELISA kit protocol.


Result Colour Indication

The ADX-150 provides visual colour indication for result interpretation:

Green – Normal

Red – Abnormal

where applicable to the programmed assay.

This can help laboratory operators identify flagged results quickly during result review.


Advanced Data Management

One of the most important improvements in the current ALTA reader is its modern digital data-handling capability.

The system can store:

Up to 200 Test Programs

and

Up to 50,000 Results

This allows laboratories to retain significantly more testing information directly within the instrument.


Export Results to CSV, XLSX & PDF

Laboratory results can be exported in commonly used file formats including:

CSV

XLSX

PDF

This makes it easier to:

  • archive results
  • transfer data to computers
  • prepare reports
  • share test information
  • perform further analysis where permitted

USB, Wi-Fi & Ethernet Connectivity

The ADX-150 provides multiple connectivity options:

USB

Wi-Fi

Ethernet

This gives laboratories flexibility in integrating the reader into their local data infrastructure.


Direct LIS Connectivity

The instrument supports direct Laboratory Information System connectivity using HL7 Version 2.3.

This can allow compatible laboratories to connect the ELISA reader directly with an LIS without requiring separate middleware.

Actual LIS integration depends on the receiving laboratory system and should be configured by qualified technical personnel.


Flexible Printing Options

The ADX-150 supports several report-printing options.

Built-In Printer

An integrated 48 mm thermal printer is provided for routine reporting.

External Printer

Compatible external printers may be used where configured.

Network Printer

Network printing is supported within compatible laboratory infrastructure.

This provides substantially greater reporting flexibility than older ELISA readers limited to an internal thermal printer.


Technical Specifications

Specification Details
Brand ALTA
Model ADX-150
Product ELISA Plate Reader
System Type Open
Plate Format 96-Well
Display 7" Capacitive Touch LCD
Measurement Range 0–4.0 OD
Linearity Range 0–3.5 OD
Photometric Resolution 0.001 OD
Accuracy up to 3 OD ±1%
Accuracy Above 3 OD ±2%
Light Source LED
Optical Channels 8
Single-Wavelength Reading Approx. 10 sec
Dual-Wavelength Reading Approx. 20 sec
Standard Wavelengths 405 / 450 / 490 / 630 nm
Optional Filters 2
Memory 200 Tests / 50,000 Results
Analysis Modes Absorbance / Cut-Off / Multi-Standard
Printer 48 mm Built-In Thermal
External Printing Supported
Network Printing Supported
Export Formats CSV / XLSX / PDF
Connectivity USB / Wi-Fi / Ethernet
LIS Interface HL7 V2.3
Dimensions Approx. 360 × 230 × 200 mm
Weight Approx. 5 kg
Catalog Number ADX-150
Pack Size 1 Unit
Use Professional IVD

Compatible ELISA Applications

The ALTA ADX-150 can support compatible ELISA assays such as:

  • HIV ELISA
  • HCV ELISA
  • HBsAg ELISA
  • Dengue ELISA
  • Infectious-disease ELISA
  • Thyroid ELISA
  • Hormone assays
  • Fertility assays
  • Serology assays
  • Endocrinology assays
  • Immunology assays
  • Other compatible absorbance-based 96-well assays

Compatibility depends on:

  • required wavelength
  • plate format
  • assay protocol
  • cut-off calculation
  • calibration model

Always verify the ELISA kit requirements before programming the instrument.


Compatible Microsidd ELISA Products

Meril MeriLisa HIV ELISA – 96 Tests

https://microsidd.com/products/merilisa-hiv-96t-pack

Meril MeriLisa HCV ELISA 3.0 – 96 Tests

https://microsidd.com/products/merilisa-hcv-elisa-3-0-96t-pack

Meril MeriLisa HBsAg ELISA – 96 Tests

https://microsidd.com/products/merilisa-hbsag-96t-pack

Explore the Complete ELISA Range

https://microsidd.com/collections/elisa-range


ALTA ELISA Reader vs ALTA ELISA Washer

A complete ELISA workflow normally involves separate reading and washing functions.

Feature ALTA ADX-150 Reader ALTA ELISA Washer
Measures Optical Density Yes No
Washes Microplate Wells No Yes
Uses Optical Filters Yes No
Aspirates Wash Buffer No Yes
Analyses Results Yes No
ELISA Workflow Stage Measurement Washing
96-Well Use Yes Yes

Both instruments can form part of a complete professional ELISA workstation.


Typical ELISA Laboratory Setup

A professional ELISA laboratory may include:

  • ELISA Plate Reader
  • ELISA Plate Washer
  • Micropipettes
  • ELISA reagent kits
  • Incubator where required
  • Refrigerator for reagent storage
  • Distilled / purified water
  • Timer
  • Laboratory computer or LIS
  • Calibrators and controls
  • Laboratory PPE

Who Can Use the ALTA ADX-150?

The instrument is intended for trained laboratory professionals working in:

  • Diagnostic laboratories
  • Pathology laboratories
  • Hospital laboratories
  • Blood banks
  • Transfusion-medicine laboratories
  • Serology laboratories
  • Clinical microbiology laboratories
  • Medical colleges
  • Research laboratories
  • Government laboratories
  • Institutional healthcare facilities

The ALTA ADX-150 is professional laboratory equipment and is not intended for consumer or home use.


Benefits for Modern Diagnostic Laboratories

The current ADX-150 provides several advantages over older-generation ELISA readers:

✓ 7-inch capacitive touchscreen
✓ LED optical system
✓ 8-channel plate reading
✓ Fast 10-second single-wavelength reading
✓ Dual-wavelength capability
✓ 0–4.0 OD measurement range
✓ 200 assay-program memory
✓ 50,000-result storage
✓ CSV, XLSX and PDF export
✓ USB connectivity
✓ Wi-Fi connectivity
✓ Ethernet connectivity
✓ HL7 LIS integration
✓ Internal and external printing options
✓ Compact 5 kg benchtop format


Installation

Install the reader on a stable laboratory bench with adequate ventilation.

Avoid:

  • excessive vibration
  • direct sunlight
  • dust
  • moisture
  • corrosive chemical vapours
  • extreme temperature changes
  • unstable power supply

The instrument should be commissioned and verified before routine patient testing.


Maintenance & Quality Control

Laboratories should establish a preventive maintenance and quality-control programme.

Typical requirements may include:

  • regular optical verification
  • reader calibration checks
  • plate-carrier inspection
  • cleaning the plate chamber
  • preventing reagent spills
  • checking printer performance
  • testing data connectivity
  • periodically verifying assay controls

Internal service or repair should be performed only by authorised or qualified technical personnel.


Transportation

When relocating the reader:

  • use the original protective packaging where possible
  • protect against impact
  • avoid excessive vibration
  • keep the instrument dry
  • transport in the recommended orientation
  • allow the unit to acclimatise after large temperature changes
  • verify instrument performance after installation

Explore Related Microsidd Collections

ELISA Range

https://microsidd.com/collections/elisa-range

Blood Bank Range

https://microsidd.com/collections/blood-bank-range

Laboratory Reagents & Kits

https://microsidd.com/collections/chemicals-liquids

The internal Microsidd cluster should now be:

ALTA ADX-150 ELISA Reader → ALTA ELISA Washer → ELISA Kits → HIV / HCV / HBsAg → Blood Bank Range → Laboratory Reagents

This is much stronger than treating the reader as an isolated equipment page.


Why Buy ALTA ADX-150 ELISA Reader from Microsidd?

Microsidd India supplies professional laboratory equipment, ELISA kits, blood-bank products and diagnostic reagents to healthcare facilities and laboratories across India.

Benefits include:

✓ Updated ALTA ADX-150 model
✓ ELISA Reader and Washer options available
✓ Multiple ELISA reagent kits available
✓ HIV, HCV and HBsAg assays available
✓ Blood-bank products available
✓ Professional laboratory-focused catalogue
✓ Technical specification support before purchase
✓ GST invoice where applicable
✓ Bengaluru-based customer support
✓ Institutional requirements supported subject to availability
✓ Online ordering to serviceable locations across India


Buy ALTA ELISA Reader in Bangalore / Bengaluru

Microsidd India supplies professional ELISA readers in Bengaluru and serves laboratories across serviceable locations in India.

Professional buyers searching for:

ELISA reader Bangalore
ELISA plate reader Bengaluru
ALTA ADX-150 India
96-well ELISA reader Bangalore
microplate reader near me
blood bank ELISA reader Bengaluru

can order through Microsidd.com subject to stock, institutional requirements and serviceability.


Microsidd India – NAP

Business Name: Microsidd India
Address: #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India
Phone / WhatsApp: +91 63667 72288
Email: support@microsidd.com
Website: https://microsidd.com
Working Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST

Find Microsidd India on Google Maps

https://www.google.com/maps/search/?api=1&query=Microsidd+India%2C+09+Green+Chambers%2C+14th+Cross%2C+RT+Nagar%2C+Bengaluru+560032


Stay Connected with Microsidd

Subscribe to Microsidd on YouTube

https://www.youtube.com/channel/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1

Follow the Microsidd WhatsApp Channel

https://whatsapp.com/channel/0029Va5lCoi1nozBZBL1gx3P


Frequently Asked Questions

What is the current ALTA ELISA reader model?

The current model is ALTA ADX-150.

Is ADX-150 an open-system reader?

Yes. It is an open-system ELISA reader.

What plate size does it read?

It is designed for 96-well ELISA microplates.

What wavelengths are included?

Four standard wavelengths are provided:

405 nm
450 nm
490 nm
630 nm

Are optional wavelengths available?

Yes. Two additional optional wavelength positions can be configured subject to requirement and availability.

What is the OD measurement range?

0–4.0 OD.

What is the linearity range?

0–3.5 OD.

What is the photometric resolution?

0.001 OD.

What type of light source does the new model use?

The ADX-150 uses an LED light source.

How many optical reading channels are provided?

The reader has 8 optical reading channels.

How fast does it read a plate?

Approximately:

10 seconds at a single wavelength

and

20 seconds at dual wavelength.

Does it support dual-wavelength reading?

Yes.

Does it have a touchscreen?

Yes. It features a 7-inch capacitive touchscreen LCD.

How many tests can be stored?

Up to 200 assay programs.

How many results can be stored?

Up to 50,000 results.

Which analysis modes are available?

The instrument supports:

Absorbance

Cut-Off

and

Multi-Standard

analysis.

Does the reader have a built-in printer?

Yes. It incorporates a 48 mm thermal printer.

Can an external printer be used?

Yes, compatible external-printing options are supported.

Can it print through a network?

Yes, network-printing functionality is supported within compatible infrastructure.

Can results be exported?

Yes.

Supported formats include:

CSV
XLSX
PDF

Does the instrument have USB?

Yes.

Does it support Wi-Fi?

Yes.

Does it support Ethernet?

Yes.

Can the reader connect directly to an LIS?

Yes. It supports HL7 Version 2.3 LIS connectivity, subject to configuration and compatibility with the laboratory information system.

Can it be used for HIV ELISA?

Yes, when the assay uses a compatible wavelength and plate format.

Can it be used for HCV ELISA?

Yes, subject to the ELISA kit requirements.

Can it be used for HBsAg ELISA?

Yes, subject to wavelength and protocol compatibility.

Does the reader wash plates?

No.

A separate ELISA microplate washer performs the washing step.

What is the approximate weight?

Approximately 5 kg.

What are the dimensions?

Approximately 360 × 230 × 200 mm.

Is this instrument for home use?

No. It is intended for professional in-vitro diagnostic laboratory use.


No Return / No Exchange Policy

This product is non-returnable and non-exchangeable.

Please verify the brand, model, wavelength requirements, plate compatibility, assay methodology, LIS requirements, laboratory workflow and product specifications before placing your order.

For laboratory equipment, customers should specifically verify the required test methodology, compatible ELISA kit, wavelength, plate format, data-connectivity requirements, laboratory infrastructure and intended application before ordering.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.


Professional / Laboratory Disclaimer

The ALTA ADX-150 ELISA Plate Reader is intended for professional in-vitro diagnostic laboratory use.

The instrument must be installed, configured, operated, maintained and quality-controlled by appropriately trained personnel according to the current manufacturer operating manual, applicable assay IFUs and the laboratory's validated SOPs.

ELISA results depend on the performance of the complete analytical system, including specimen quality, reagent quality, pipetting, washing, incubation, reader configuration, wavelength selection, controls and result interpretation.

Clinical decisions should not be based solely on an instrument-generated value without appropriate assay validation and professional interpretation.

Product specifications table
Specification name Specification Value
Color pattern White

Didn't find the product you were looking for?