4TH GENERATION MICROLISA HIV Ag & Ab 96 test pack


Price:
Sale priceRs. 4,850.00

Description

HIV ELISA 96t 4th Generation


4TH GENERATION ELISA HIV Ag & Ab


INTENDED USE


4TH GENERATION MICROLISA HIV Ag & Ab is an in- vitro qualitative enzyme immunoassay for the detection of antibodies to HIV-1 and/or HIV-2 and HIV-1 p24 antigen in human serum or plasma. It is intended for screening of blood donors or other individuals at risk for HIV-1 and/or HIV-2 infection and for clinical diagnostic testing.


SALIENT FEATURES


Use of Envelope Antigens gp41, C terminus of gp120 for HIV-1 and gp36 for HIV-2 & simultaneously detection of p24 antigen with p24 monoclonal antibodies


Detection of Group O & subtype C for HIV-1 prevalent in India


Colour coded reagents to monitor the procedural steps


Assay procedure: 120 mins


Shelf life: 12 months at 2-8°C


Sensitivity 100% & Specificity 99.97%


Significant reduction in window period


Easy to use on automated and semi-automatic processor


4TH GENERATION MICROLISA HIV Ag & Ab test is an enzyme immunoassay based on "Sandwich ELISA". HIV envelop proteins gp41 representing immunodominant epitopes and anti-p24 antibodies are coated into microtiter wells. Specimens and controls are added to the microtiter wells and incubated. Antibodies to HIV-1 and HIV-2 if present in the specimen, will bind to the specific antigens absorbed onto the surface of the wells. The plate is then washed to remove unbound material. Horseradish peroxidase (HRPO) conjugated gp41, C-terminus of gp120 of HIV-1 and gp36 of HIV-2 and anti-p24 antibodies is added to each well. The conjugate will bind to HIV antigen-antibody or anti-p24 antibody-antigen complex present. Finally substrate solution containing chromogen and hydrogen peroxide is added to the wells and incubated. A blue colour will develop in proportion to the amount of HIV-1 and/or HIV-2 antibodies and /or HIV-1 p24 antigen present in the specimen. The colour reaction is stopped by a stop solution. The enzyme substrate reaction is read by EIA reader for absorbance at a wavelength of 450 nm. If the sample does not contain HIV-1 or HIV-2 antibodies or HIV-1 p24 antigen, then enzyme conjugate will not bind and the solution in the wells will be either colourless or only a faint background colors develops.


EVALUATIONS


NARI-PUNE As per evaluation at National Aids Research centre (reference laboratory) following results were obtained 



Sensitivity- 100 % & Specificity-100 %


NIMHANS-BANGALORE Evaluation at NIMHANS National AIDS reference Laboratory indicated overall Sensitivity of 100 % & Specificity of 100 %


HIV Test Approved by Drug Controller General of India( DCGI) for the usage in Blood Banks