Accurex Lipid Profile Meter and test strips complete guide showing total cholesterol HDL triglycerides calculated LDL LPS-101 strips and point of care lipid testing

Accurex Lipid Profile Meter & Test Strips Complete Guide

The Accurex Lipid Profile Meter, also described as the Accurex Blood Lipid Analysis System, is a portable point-of-care analyser designed for broader lipid testing than a conventional Total Cholesterol-only meter.

Using compatible Accurex dry-chemistry test strips, the system can directly measure:

  • Total Cholesterol – TC
  • HDL Cholesterol
  • Triglycerides – TG

With the appropriate 3-in-1 lipid panel, the meter can also calculate:

  • LDL Cholesterol
  • TC/HDL Ratio

This makes the Accurex system different from portable meters that measure only Total Cholesterol.

This complete guide explains how the Accurex Lipid Profile Meter works, compatible test strips, specimen types, sample volume, result time, coding, memory, operating conditions and what to check before purchasing the meter and consumables.


Accurex Lipid Profile Meter at a Glance

Feature Accurex Lipid Profile Meter
System Type Blood Lipid Analysis System / Lipid Profile Meter
Meter Model Platform LPM-101 platform
Total Cholesterol – TC ✅ Directly measured
HDL Cholesterol ✅ Directly measured
Triglycerides – TG ✅ Directly measured
LDL Cholesterol ✅ Calculated by the compatible system where applicable
TC/HDL Ratio ✅ Calculated
Measurement Principle Reflectance photometry / photochemical dry chemistry
Sample Types Capillary whole blood, venous whole blood, plasma and serum
LPS-101 Sample Volume Approximately 35 µL
Test Time Approximately 2 minutes
Memory Up to 500 records
Units mg/dL or mmol/L
Operating Temperature 10°C–35°C
Test Strip Storage 2°C–30°C
Power Rechargeable battery
Compatible Strip References LPS-101, TCS-101, TGS-101, HLS-101

What Does the Accurex Lipid Profile Meter Measure?

The Accurex platform is designed to provide multiple lipid parameters rather than Total Cholesterol alone.

With the compatible 3-in-1 lipid profile strip, it directly measures:

TC + HDL + TG

and can calculate:

LDL + TC/HDL Ratio

This makes the meter useful where a broader point-of-care lipid assessment is required.


Which Lipid Parameters Are Directly Measured?

Parameter How Accurex Reports It
Total Cholesterol – TC Directly measured
HDL Cholesterol Directly measured
Triglycerides – TG Directly measured
LDL Cholesterol Calculated from the measured lipid values when applicable
TC/HDL Ratio Calculated by the meter

Does Accurex Measure LDL Directly?

No.

With the LPS-101 lipid-panel strip, LDL is calculated from the directly measured:

  • Total Cholesterol
  • HDL
  • Triglycerides

The system uses the applicable lipid-calculation formula programmed into the meter.

This is different from a system that directly assays LDL itself.

Always interpret calculated LDL according to the manufacturer's limitations and appropriate clinical guidance.


What Is the TC/HDL Ratio?

The Accurex system can also calculate the ratio between:

Total Cholesterol and HDL Cholesterol

This is displayed as:

TC/HDL Ratio

The ratio is derived from the directly measured TC and HDL results.


How Does the Accurex Lipid Profile Meter Work?

The system uses photochemical dry-chemistry technology.

After an appropriate specimen is applied to the compatible test strip:

  1. The specimen enters the reaction area.
  2. Blood cells are filtered or processed by the strip system.
  3. The lipid analytes react with enzymes and other chemicals in the reaction layer.
  4. The reaction creates a colour change.
  5. The meter measures the optical response.
  6. The colour intensity is converted into a lipid concentration.

The LPM-101 system measures the reflectance response at the reaction endpoint to determine the result.


What Test Strips Work with the Accurex Lipid Profile Meter?

The Accurex Blood Lipid Analysis System supports several designated strip references.

Strip Reference Test Purpose
LPS-101 3-in-1 Lipid Panel Directly measures TC + HDL + TG and enables calculated LDL + TC/HDL ratio
TCS-101 Total Cholesterol TC-only measurement
TGS-101 Triglycerides TG-only measurement
HLS-101 HDL Cholesterol HDL-only measurement

Only use strips specifically identified as compatible with the Accurex Blood Lipid Analysis System.


What Is the Accurex LPS-101 3-in-1 Lipid Panel?

The LPS-101 is the most important strip configuration for users wanting a broader lipid profile from a single test strip.

One compatible LPS-101 test directly measures:

  • Total Cholesterol
  • HDL Cholesterol
  • Triglycerides

The meter then uses those measured results to calculate:

  • LDL Cholesterol
  • TC/HDL Ratio

Therefore, one LPS-101 strip can provide substantially more lipid information than a Total Cholesterol-only strip.

View Accurex Lipid Profile Test Strips – 25 Pack


How Much Sample Does the Accurex Lipid Profile Test Require?

The LPS-101 3-in-1 lipid profile strip requires approximately:

35 µL of specimen

Other compatible parameter-specific Accurex strip configurations may use a different sample volume.

Always follow the instructions supplied with the exact strip being used rather than assuming every Accurex strip requires the same quantity.


How Long Does the Accurex Lipid Profile Test Take?

The LPM-101 system provides lipid results in approximately:

2 minutes

After the sample is applied correctly, the meter automatically begins the testing process and displays the result when the reaction is complete.


Which Sample Types Can Be Used?

The Accurex Blood Lipid Analysis System supports:

  • Capillary whole blood
  • Venous whole blood
  • Plasma
  • Serum

The meter allows the sample type to be selected in its settings so the system can be configured for the specimen being tested.


Using Capillary Blood

For fingertip testing, the manufacturer's instructions advise using a fresh capillary blood specimen.

For the lipid-panel workflow:

  1. Prepare the finger according to the test procedure.
  2. Obtain the blood drop.
  3. Wipe away the first drop.
  4. Use the subsequent drop for testing.
  5. Collect the required amount with the appropriate capillary transfer tube or pipette.
  6. Apply the specimen to the designated area of the test strip.

Follow the current strip insert supplied with your pack.


Using Venous Whole Blood, Serum or Plasma

The meter can also support appropriate professional testing workflows using venous whole blood, serum or plasma.

For venous whole blood, the manufacturer specifies appropriate anticoagulants such as:

  • EDTA
  • Heparin

Professional users should follow the specimen preparation and timing requirements specified in the current manufacturer instructions.


Accurex Lipid Measurement Ranges

The LPM-101 system manual specifies the following measurement ranges:

Parameter Measurement Range
Total Cholesterol Approximately 100–500 mg/dL
HDL Cholesterol Approximately 15–100 mg/dL
Triglycerides Approximately 45–650 mg/dL

Calculated parameters depend on the measured values and the manufacturer's calculation conditions.


Accurex Uses a Code-Chip System

Each new box of compatible Accurex test strips includes a corresponding code chip.

When starting a new strip box:

  1. Locate the code chip supplied with the strips.
  2. Insert it into the meter's code-chip slot.
  3. Check the code number printed on the strip packaging.
  4. Check the code displayed by the meter.
  5. Confirm that the codes match before testing.

The manufacturer warns that incorrect coding can lead to inaccurate results.


Do Not Mix Accurex Code Chips Between Strip Lots

Keep each strip lot together with its corresponding code chip.

When opening a new box:

  • Use the new chip supplied with that box.
  • Do not assume the previous chip is correct.
  • Compare the code before testing.
  • Leave the matching chip installed until changing to another strip box.

How Many Results Can the Accurex Meter Store?

The Accurex / LPM-101 Blood Lipid Analysis System can store up to:

500 test records

This can be useful for clinics and structured monitoring workflows where previous results need to be reviewed.


Accurex Lipid Meter Power Supply

The meter uses a rechargeable battery.

The manufacturer notes that the meter is not intended to perform testing while the battery is actively charging.

Ensure adequate charge before beginning a testing session.


What Temperature Can the Accurex Meter Be Used At?

The system operating range specified for testing is approximately:

10°C–35°C

The test materials should also be within their permitted operating temperature before testing.

Avoid testing in:

  • Direct sunlight
  • Very hot environments
  • Very cold environments
  • Excessive humidity

How Should Accurex Lipid Test Strips Be Stored?

The manufacturer specifies strip storage at approximately:

2°C–30°C

Keep strips:

  • In their original packaging
  • Protected from direct sunlight
  • Dry
  • Within the specified temperature range
  • Away from freezing conditions

Do not use strips after their printed expiry date.


Accurex Meter vs Accurex Test Strips

The meter is reusable, but every lipid test requires a new compatible disposable strip.

Item Reusable?
Accurex Lipid Profile Meter ✅ Yes
Lipid Test Strip ❌ No — single use
Lancet ❌ No — single use
Code Chip Used with the corresponding strip lot

Are Test Strips Included with the Accurex Lipid Meter?

No.

The current Microsidd listing for the Accurex Lipid Profile Meter contains:

1 × Accurex Lipid Profile Meter / Blood Lipid Analysis System

The compatible lipid test strips are sold separately.

This is important to understand before ordering because the meter cannot perform a lipid test without the appropriate compatible strip.

View Accurex Lipid Profile Meter


Accurex Lipid Profile Test Strips – 25 Pack

Microsidd also lists the compatible Accurex Lipid Profile Test Strips in a:

25-strip pack

The 3-in-1 panel is designed to provide:

  • TC
  • HDL
  • TG
  • Calculated LDL
  • Calculated TC/HDL ratio

View Accurex Lipid Profile Test Strips – 25 Pack


Why Does the Meter Say LYSUN?

Customers may notice that the hardware can display the LYSUN name and the model designation LPM-101.

The Blood Lipid Analysis System platform is manufactured by Hangzhou Lysun Biotechnology and marketed in India through Accurex Biomedical.

Therefore, seeing LYSUN branding on the meter does not mean you have received an unrelated cholesterol meter.

Always verify the exact model, compatible strips and supplied product against the current listing and packaging.


Accurex vs QuikCheck: Why They Should Not Be Confused

The two meters may appear similar in size and design, but their capabilities are different.

Parameter QuikCheck Accurex
Total Cholesterol ✅ ✅
HDL ❌ ✅
Triglycerides ❌ ✅
LDL ❌ ✅ Calculated
TC/HDL Ratio ❌ ✅ Calculated

For a detailed buyer comparison:

Read: Total Cholesterol Meter vs Lipid Profile Meter – QuikCheck vs Accurex Complete Comparison


Who Can Consider the Accurex Lipid Profile Meter?

The system can be useful in appropriate point-of-care workflows for:

  • Doctors and clinics
  • Diagnostic centres
  • Laboratories requiring portable lipid testing
  • Preventive-health programmes
  • Corporate wellness programmes
  • Health-screening camps
  • Mobile healthcare services
  • Professional lipid-monitoring workflows

The applicable testing protocol should be determined by the responsible healthcare professional or facility.


Accurex for Health Screening Camps

Portable multi-parameter testing can be particularly useful when screening programmes require more information than Total Cholesterol alone.

One compatible lipid-panel test can provide:

TC + HDL + TG + calculated LDL + TC/HDL ratio

This can make the system useful for appropriate cardiovascular and metabolic screening workflows.


Accurex for Clinics and Diagnostic Centres

The system offers several features useful in professional environments:

  • Multi-parameter lipid testing
  • Portable design
  • Multiple specimen types
  • Approximately 2-minute testing
  • Up to 500 stored records
  • Code-chip calibration
  • Optical system verification
  • Quality-control functionality

Optical Verification

The Accurex LPM-101 platform includes an Optical Verify Strip procedure.

This is used to check whether the meter's optical measurement system is functioning correctly.

The manufacturer recommends performing an optical check when appropriate, particularly if:

  • The meter has been dropped
  • The meter has become wet
  • Meter operation is uncertain
  • A performance check is required

Quality Control

Professional users should follow appropriate quality-control procedures.

The manufacturer's manual specifically recommends control testing in situations including:

  • When a new package of strips is opened
  • When a new operator begins using the meter
  • When results appear inaccurate
  • After maintenance or service

Facilities should also follow their own laboratory, accreditation and regulatory requirements.


Basic Accurex Lipid Testing Workflow

The exact procedure depends on the strip being used, but the general workflow is:

  1. Check the meter and strip pack.
  2. Insert the correct code chip.
  3. Verify that the code matches the strip pack.
  4. Select the correct specimen type.
  5. Insert the compatible strip fully into the meter.
  6. Wait for the blood-drop/sample symbol.
  7. Prepare the appropriate specimen.
  8. Apply the required sample volume to the designated application area.
  9. Allow the test to complete.
  10. Read the result from the display.
  11. Dispose of the used strip and sampling material appropriately.

Do Not Touch the Strip Reaction Area

When handling Accurex test strips:

  • Hold the strip by its designated handle area.
  • Do not touch the reagent or reaction area.
  • Do not use discoloured strips.
  • Do not use physically damaged strips.
  • Do not use expired strips.

Can Accurex Test Strips Be Reused?

No.

Every lipid test requires a new compatible strip.

Do not:

  • Wash a used strip
  • Apply another specimen to the same strip
  • Reuse the strip for another patient
  • Return a used strip to the package

What If an Accurex Result Is Unexpected?

If a result appears inconsistent with expectations, review:

  • Correct strip selection
  • Strip expiry
  • Strip storage conditions
  • Code-chip matching
  • Selected specimen type
  • Required sample volume
  • Specimen handling
  • Operating temperature
  • Meter cleanliness
  • Quality-control results

Repeat testing should use a fresh compatible strip where appropriate.

Unexpected or clinically important lipid results may require confirmation using an appropriate laboratory method.


Can Accurex Replace a Laboratory Lipid Profile?

The Accurex system provides quantitative point-of-care lipid measurements and can be useful for appropriate screening and monitoring workflows.

However, it should not automatically be considered a replacement for laboratory testing in every clinical situation.

Laboratory testing may still be required when:

  • A diagnosis is being established
  • Results are unexpected
  • Treatment decisions depend on precise lipid assessment
  • Additional lipid or biochemical parameters are required
  • A healthcare professional recommends confirmation

Which Accurex Product Should You Buy?

If You Need the Meter

Choose:

Accurex Lipid Profile Meter / Blood Lipid Analysis System

Remember: the current Microsidd meter listing does not include test strips.

If You Already Own the Meter

Choose the compatible consumable required for your test.

For the 3-in-1 lipid profile:

Accurex Lipid Profile Test Strips – 25 Pack

If You Only Need Total Cholesterol

A simpler Total Cholesterol system may be sufficient depending on your workflow.

Compare both systems here:

QuikCheck vs Accurex Complete Comparison


Accurex Purchasing Checklist

  • ✓ Do you need a full lipid profile or only Total Cholesterol?
  • ✓ Have you selected the correct compatible Accurex strip?
  • ✓ Do you need LPS-101, TCS-101, TGS-101 or HLS-101?
  • ✓ Have you ordered strips separately with the meter?
  • ✓ Is the code chip supplied with the strip lot available?
  • ✓ Is the strip pack within expiry?
  • ✓ Can you store strips at 2°C–30°C?
  • ✓ Is the intended specimen type supported?
  • ✓ Does the system fit your clinic or screening workflow?

Frequently Asked Questions

What is the Accurex Lipid Profile Meter?

It is a portable Blood Lipid Analysis System designed for quantitative lipid testing using compatible dry-chemistry strips.

What does the Accurex Lipid Meter measure?

The compatible system directly measures Total Cholesterol, HDL and Triglycerides and can calculate LDL and the TC/HDL ratio.

Does Accurex measure LDL directly?

No. LDL is calculated from the applicable measured lipid values when using the compatible lipid-panel system.

Does Accurex measure HDL?

Yes. HDL Cholesterol is directly measured.

Does Accurex measure triglycerides?

Yes. Triglycerides are directly measured.

Does the meter show TC/HDL ratio?

Yes. The compatible system calculates the TC/HDL ratio.

Which test strips work with the Accurex Lipid Profile Meter?

The LPM-101 platform supports Accurex-compatible strip references including LPS-101, TCS-101, TGS-101 and HLS-101.

What does LPS-101 test?

LPS-101 is the 3-in-1 lipid panel that directly measures Total Cholesterol, HDL and Triglycerides and enables calculated LDL and TC/HDL ratio.

How much specimen does the Accurex lipid profile test require?

The LPS-101 lipid profile strip requires approximately 35 µL.

How quickly does the Accurex lipid test provide results?

The LPM-101 system provides results in approximately 2 minutes.

Can fingertip blood be used?

Yes. Capillary whole blood is supported.

Can venous blood be used?

Yes. Venous whole blood is supported when collected and handled according to the manufacturer's instructions.

Can serum or plasma be used?

Yes. The system supports serum and plasma in addition to whole blood.

How many results can the Accurex meter store?

The system stores up to approximately 500 records.

Does the meter use batteries?

The LPM-101 platform uses a rechargeable battery.

What temperature should the test be performed at?

The system operating temperature is approximately 10°C–35°C.

How should the strips be stored?

Compatible Accurex lipid strips should generally be stored at approximately 2°C–30°C, protected from direct sunlight and freezing.

Do I need a code chip?

Yes. Use the code chip supplied with the current box of compatible strips and confirm that the displayed code matches the strip packaging.

Are Accurex strips compatible with QuikCheck?

No. QuikCheck and Accurex are different meter-and-strip systems and their consumables are not interchangeable.

Are test strips included with the Accurex meter?

No. The current Microsidd meter listing does not include lipid test strips. They must be purchased separately.

Why does the Accurex meter show LYSUN on the device?

The LPM-101 hardware platform is manufactured by Hangzhou Lysun Biotechnology and marketed in India through Accurex Biomedical. Verify the exact meter and compatible consumables according to the current product packaging.

Can Accurex replace a laboratory lipid profile?

It is a point-of-care quantitative lipid-testing system. Laboratory confirmation remains appropriate where clinically indicated, especially for diagnosis, unexpected results or treatment decisions.


Related Knowledge Hub Guides

Total Cholesterol Meter vs Lipid Profile Meter: QuikCheck vs Accurex

Understand why these similar-looking meters perform different tests and use completely different consumables.

Read QuikCheck vs Accurex Complete Comparison

ACON QuikCheck Cholesterol Monitor & Test Strips Complete Guide

Learn about the Total Cholesterol-only QuikCheck system.

Read the QuikCheck Complete Guide

QuikCheck Cholesterol Test Strip Compatibility, Expiry & Storage Guide

Learn how QuikCheck strips differ from Accurex lipid strips.

Read the QuikCheck Strip Compatibility Guide


Shop Accurex Lipid Testing Products

Accurex Lipid Profile Meter

Portable multi-parameter Blood Lipid Analysis System for compatible Accurex lipid test strips.

View Accurex Lipid Profile Meter

Accurex Lipid Profile Test Strips – 25 Pack

Compatible 3-in-1 lipid-panel strips for Total Cholesterol, HDL and Triglycerides with calculated LDL and TC/HDL ratio.

View Accurex Lipid Profile Test Strips – 25 Pack


Explore the Microsidd Knowledge Hub

Read more practical guides covering diagnostic meters, test-strip compatibility, point-of-care testing and laboratory diagnostics:

Visit the Microsidd Knowledge Hub


Important Medical & Purchasing Note

The Accurex Lipid Profile Meter is an in-vitro diagnostic point-of-care system intended for use with the compatible Accurex test strips specified for the LPM-101 platform.

Always verify:

  • The exact meter model
  • The lipid parameters required
  • The correct test-strip reference
  • The code chip supplied with the strip lot
  • Sample type
  • Required specimen volume
  • Strip expiry
  • Storage conditions

before testing.

Unexpected, abnormal or clinically important lipid results should be interpreted in the appropriate clinical context and confirmed with laboratory testing when indicated.

These diagnostic products are non-returnable and non-exchangeable.
Please verify the meter model, test parameter, strip compatibility, pack size and product specifications before placing your order.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making a claim regarding an incorrect product received.

Previous Next

Leave a comment

0 comments

Please note, comments need to be approved before they are published.