Spectrum Wright’s Stain Solution 125ml is a laboratory staining reagent used for the differential staining of peripheral blood smears, bone marrow smears and suitable cytological preparations.
Wright stain belongs to the Romanowsky group of stains and is commonly used in hematology laboratories to differentiate blood-cell components by producing characteristic colour contrast between nuclei, cytoplasm, granules and red blood cells.
This Spectrum product is supplied in a 125 ml glass bottle and is intended for professional laboratory and educational use.
Customers looking for Spectrum Wright’s Stain Solution in Bengaluru can order online from Microsidd India, RT Nagar, Bengaluru, subject to stock availability.
Wright’s stain is a Romanowsky-type hematology stain used to provide differential colouration of blood cells and cellular structures.
Standard Wright stain formulations contain combinations of eosin and polychromed methylene-blue / azure dyes.
These acidic and basic dyes interact differently with cellular components, allowing red cells, white-cell nuclei, cytoplasm and granules to be distinguished under a microscope.
Spectrum Wright’s Stain Solution may be used in suitable laboratory procedures for:
Wright staining works through the differential binding of acidic and basic dyes to cellular components.
The eosin component behaves as an acidic dye and tends to stain basic cellular structures in pink to red shades.
Methylene-blue-derived and azure dyes act as basic dyes and stain acidic cellular structures, especially nuclear material, in blue to purple shades.
The combined Romanowsky reaction produces characteristic differential colours that help distinguish blood-cell types and cellular details.
When Wright staining is performed correctly, typical appearances may include:
Final colour depends on specimen preparation, stain quality, staining time, buffer pH and washing technique.
Romanowsky staining is sensitive to pH.
Standard Wright staining procedures commonly use a buffer around pH 6.4.
If the staining environment becomes too alkaline, the smear may appear excessively blue. If it becomes too acidic, the smear may appear excessively red.
For consistent laboratory results, use the buffer and pH specified by your validated procedure.
Always follow the current Spectrum instructions and your laboratory SOP.
A general Wright staining workflow is:
Important: Staining times vary between Wright stain formulations and laboratory protocols. Do not use arbitrary timings for quantitative or diagnostic laboratory work.
| Step | Action | Purpose |
|---|---|---|
| 1 | Prepare and air-dry smear | Create suitable cellular film |
| 2 | Apply Wright’s Stain | Fix and begin staining |
| 3 | Add buffer | Develop Romanowsky colour reaction |
| 4 | Wash gently | Remove excess stain |
| 5 | Air dry and examine | Assess cellular morphology |
| Product Name | Wright’s Stain Solution |
| Brand | Spectrum |
| Product Code | W0103 |
| Pack Size | 125 ml |
| HSN | 3822.00.19 |
| Packaging | Glass Bottle |
| Stain Type | Modified Romanowsky Stain |
| Typical Dye System | Eosin with polychromed methylene-blue / azure dyes |
| Primary Application | Differential staining of blood and bone marrow smears |
| Method | Wright Staining Method |
| Intended Use | Professional laboratory and educational use |
Important: Spectrum’s current catalogue confirms product code W0103, 125 ml pack, glass-bottle packaging and HSN 3822.00.19. Exact formulation, methanol concentration, staining times, storage conditions and hazard classification should be verified from the actual Spectrum label, SDS or technical documentation.
| Feature | Wright Stain | Leishman Stain | Giemsa Stain |
|---|---|---|---|
| Stain Family | Romanowsky | Romanowsky | Romanowsky |
| Common Use | Peripheral blood and bone marrow | Peripheral blood smear differential staining | Blood parasites and detailed hematology staining |
| Typical Workflow | Stain followed by buffer | Stain followed by buffered dilution | Usually diluted before use |
| Selection | Follow laboratory SOP | Follow laboratory SOP | Follow laboratory SOP |
These stains are not automatically interchangeable. Use the stain specified by your laboratory procedure or institutional protocol.
You can buy Spectrum Wright’s Stain Solution 125ml online from Microsidd India, Bengaluru.
Microsidd India supplies laboratory stains, diagnostic reagents, hematology products, laboratory consumables and medical products to laboratories, hospitals, clinics, educational institutions and institutional buyers.
Microsidd India
RT Nagar, Bengaluru, Karnataka, India
View Microsidd India Bengaluru Store & Location Information
Bengaluru customers can order through Microsidd.com. Depending on stock availability and location, local delivery or urgent pickup arrangements may also be available.
Customers searching for:
can order Spectrum Wright’s Stain Solution through Microsidd India, subject to stock availability.
| Buying Factor | Microsidd India | Other Online Stores | Offline Stores |
|---|---|---|---|
| Product Identification | Spectrum Wright’s Stain clearly identified | Depends on seller listing | Depends on available stock |
| Pack Size | 125 ml clearly stated | May vary between listings | Depends on stock |
| Method Information | Romanowsky staining workflow explained | May be limited | Depends on product knowledge |
| Bengaluru Local Presence | Yes – Bengaluru based | Seller location may vary | Yes when buying locally |
| Online Ordering | Available through Microsidd.com | Usually available | May not be available |
| Laboratory Product Range | Multiple stains, diagnostic reagents and laboratory products | Varies by seller | Depends on store specialisation |
Wright’s Stain is used primarily for differential staining of peripheral blood smears, bone marrow smears and suitable cytological preparations.
Yes. Wright’s Stain belongs to the Romanowsky group of hematology stains.
Standard Wright stain formulations use eosin together with polychromed methylene-blue and azure-type dyes.
This Spectrum product is supplied in a 125 ml bottle.
Spectrum lists Wright’s Stain Solution 125 ml under product code W0103.
Spectrum’s current catalogue lists HSN 3822.00.19.
Yes. Wright-type Romanowsky staining is commonly used for peripheral blood and bone marrow smear examination.
Standard Wright staining procedures commonly use a buffer around pH 6.4. Always follow your laboratory method.
Many Wright stain formulations are methanol-based and can provide fixation during the staining process. However, follow the exact Spectrum instructions or your laboratory SOP before assuming that no separate fixation is required.
Properly stained red blood cells typically appear pink to salmon-pink.
White-cell nuclei generally appear blue to purple depending on cell type and staining conditions.
Yes. Wright-type staining is commonly used to differentiate neutrophils, lymphocytes, monocytes, eosinophils and basophils during microscopic examination.
No. It is a professional laboratory staining reagent intended for trained laboratory personnel and educational use.
No. Both belong to the Romanowsky family but differ in formulation and procedure. Use the stain specified by your laboratory SOP.
You can order Spectrum Wright’s Stain Solution 125 ml from Microsidd India, RT Nagar, Bengaluru through Microsidd.com, subject to availability.
Before purchasing, verify:
Hematology stains are method-specific. Confirm that Wright’s Stain is the reagent required by your laboratory procedure before ordering.
Spectrum Wright’s Stain Solution is a laboratory staining reagent and is supplied under Microsidd India's applicable No Return / No Exchange policy.
Customers must verify the brand, product name, product code, pack size, staining method and intended application before ordering.
If a parcel is received damaged, incorrect or with another eligible fulfilment issue, follow Microsidd India's applicable support policy.
For eligible delivery-related claims, an original, continuous and unedited unboxing video may be required. Recording should begin before opening the shipment and continue until all contents are clearly visible.
When opening the shipment, carefully cut the outer packing tape with a blade or suitable cutter instead of tearing the parcel, taking additional care because the product may be supplied in a glass bottle.
Wright’s Stain Solution may contain methanol or other solvent components and should be handled according to the actual Spectrum label and Safety Data Sheet.
Do not assume Spectrum’s exact solvent concentration or hazard classification from another manufacturer’s Wright stain. Refer to the supplied Spectrum SDS for W0103.
Spectrum Wright’s Stain Solution is a professional laboratory staining reagent. It is not intended for self-testing, treatment or unsupervised diagnostic use.
The information on this page is provided for product identification, purchasing guidance and general laboratory education only. It does not replace the manufacturer’s label, Safety Data Sheet, validated laboratory SOP or hematology interpretation guidelines.
Blood-cell morphology and differential counts should be evaluated by appropriately trained laboratory professionals using properly prepared smears, quality-control procedures and validated methods.
Microscopic staining results should always be interpreted within the appropriate laboratory and clinical context.
Always follow the current Spectrum documentation and your laboratory’s approved staining procedure.
Microsidd India – Medical, Diagnostic & Laboratory Products
RT Nagar, Bengaluru, Karnataka, India
Online Store: Microsidd.com
Microsidd India – Bengaluru Store, Location & Contact Information
```
| Specification name | Specification Value |
|---|---|
| Chemical grade | Laboratory |
| Color pattern | Brown, Blue |