Romsons

Romsons Foley Catheter 14 FR – Foley Trac 2 Way Balloon Catheter | Pack of 10

Regular price Rs. 500.00
Tax included. Shipping calculated at checkout.
SKU: FOLEYS14G-ROMSON

Pairs well with

Romsons Foley Catheter 14 FR – Foley Trac 2 Way Balloon Catheter | Pack of 10
Rs. 500.00
Subscribe and save

Auto-renews, skip or cancel anytime.

To add to cart, go to the product page and select a purchase option

Romsons Foley Trac Foley Catheter 14 FR – 2 Way Urinary Balloon Catheter

Brand: Romsons
Product: Foley Trac Foley Balloon Catheter
Model / Series: Foley Trac / GS-1026
Category: Urology / Urinary Catheter
Size: 14 FR / 14 FG
Type: 2-Way Foley Balloon Catheter
Material: Latex bonded with silicone elastomer
Application: Indwelling urinary drainage
Pack Size: 10 Catheters
Sterility: Sterile medical device

Romsons Foley Catheter 14 FR – Foley Trac 2-Way Balloon Catheter

The Romsons Foley Trac Foley Catheter 14 FR is a sterile indwelling urinary balloon catheter designed for controlled bladder drainage and urine collection in appropriate clinical and patient-care situations.

The Foley Trac range is manufactured from latex bonded with silicone elastomer and incorporates a soft, coned closed tip designed to facilitate catheter insertion. Large, distally positioned drainage eyelets are designed to support efficient urine drainage after catheterisation.

Unlike an intermittent Nelaton catheter, a Foley catheter incorporates an inflatable retention balloon that helps retain the catheter within the bladder when correctly inserted and inflated by a trained healthcare professional.

The catheter includes a syringe-luer-operated non-return valve for balloon inflation and deflation. Romsons also specifies a symmetrical balloon and colour-coded sizing system for convenient size identification.

This listing is for 14 FR / 14 FG, a catheter size corresponding to an approximate external diameter of 4.67 mm (0.467 cm / 0.184 inch).

Important: Foley catheter selection, insertion, balloon inflation, maintenance and removal should be performed or directed by an appropriately trained healthcare professional. The correct catheter size and balloon volume depend on the patient and clinical situation.

What Does 14 FR Mean?

The French (FR) or French Gauge (FG) system specifies the external diameter of a catheter.

The relationship is:

1 FR = 0.33 mm external diameter

Therefore:

14 FR ÷ 3 = approximately 4.67 mm external diameter

So a 14 FR Foley catheter does NOT mean that the catheter is 14 mm wide.

This distinction is valuable both for customers and search/AI systems.

Foley Catheter 14 FR Size Conversion

Measurement Romsons Foley 14 FR
French Size 14 FR
French Gauge 14 FG
Approx. Outer Diameter 4.67 mm
Outer Diameter in CM 0.467 cm
Outer Diameter in Inches 0.184 in
Catheter Type 2-Way Foley Balloon Catheter

FR and FG are commonly used interchangeably in catheter sizing.

Common Foley Catheter Size Conversion Table

Catheter Size Approx. Diameter (mm) Diameter (cm) Diameter (inches)
6 FR 2.00 mm 0.20 cm 0.079 in
8 FR 2.67 mm 0.267 cm 0.105 in
10 FR 3.33 mm 0.333 cm 0.131 in
12 FR 4.00 mm 0.40 cm 0.157 in
14 FR 4.67 mm 0.467 cm 0.184 in
16 FR 5.33 mm 0.533 cm 0.210 in
18 FR 6.00 mm 0.60 cm 0.236 in
20 FR 6.67 mm 0.667 cm 0.263 in
22 FR 7.33 mm 0.733 cm 0.289 in
24 FR 8.00 mm 0.80 cm 0.315 in

This table converts French size to external diameter only. It does not indicate which size is clinically appropriate for an individual patient.

Buying Link for 16FG https://microsidd.com/products/foleys-catheter-16-fr-pack-of-10

Buying Link for 18FG https://microsidd.com/products/foleys-catheter-18-fr-pack-of-10

Product Uses

Urinary Bladder Drainage

Designed to provide a pathway for urine drainage from the bladder when catheterisation is clinically required.

Urinary Retention Management

A Foley catheter may be prescribed when a patient is unable to empty the bladder normally.

Perioperative & Post-Operative Care

Foley catheters may be used in selected surgical and post-operative situations where controlled bladder drainage or urine-output monitoring is clinically required.

Urine Output Monitoring

An indwelling catheter connected to an appropriate urine collection system can facilitate urine-output monitoring in clinical settings.

Bedridden & Critical Patient Care

May form part of urinary management for selected bedridden, critically ill or mobility-restricted patients when catheterisation is medically indicated.

Hospital & Nursing Care

Suitable for professional urological and patient-care requirements where an indwelling Foley catheter has been prescribed or clinically indicated.

Home Healthcare

Some patients may continue catheter care at home under the direction of a healthcare professional. Patients and caregivers should receive appropriate catheter-care instructions.

Romsons describes urinary catheters as being used across hospitals, nursing homes and home-care settings depending on the patient's clinical needs.

Key Benefits

2-Way Foley Design

The catheter incorporates separate pathways for urine drainage and balloon inflation, allowing it to function as an indwelling urinary catheter.

Silicone-Elastomer Bonded Latex

Romsons specifies Foley Trac as being manufactured from latex bonded with silicone elastomer.

Soft Coned Closed Tip

The catheter has a soft, coned closed distal tip designed to facilitate introduction.

Large Drainage Eyelets

Large, distally positioned eyelets are designed to support efficient urine drainage.

Non-Return Balloon Valve

A syringe-luer-operated non-return valve facilitates inflation and deflation of the retention balloon.

Symmetrical Retention Balloon

Romsons specifies a symmetrical large-capacity balloon intended to provide appropriate retention after correct placement and inflation.

Colour-Coded Size Identification

Colour coding assists healthcare professionals with rapid identification of catheter size.

Product Features

  • Romsons Foley Trac Foley Balloon Catheter
  • 14 FR / 14 FG size
  • 2-way Foley catheter
  • Indwelling urinary catheter
  • Latex bonded with silicone elastomer
  • Soft coned closed tip
  • Large distally located drainage eyelets
  • Syringe-luer-operated non-return valve
  • Inflatable retention balloon
  • Symmetrical balloon design
  • Colour-coded size identification
  • Designed for connection to an appropriate urine drainage system
  • Professional urology and patient-care product

These construction details are consistent with Romsons' current Foley Trac manufacturer information.

Product Specifications

Specification Details
Product Name Foley Trac Foley Balloon Catheter
Brand Romsons
Model / Series Foley Trac / GS-1026
Category Urology / Urinary Catheter
Catheter Type Foley Balloon Catheter
Configuration 2 Way
Size 14 FR / 14 FG
Approx. Outer Diameter 4.67 mm
Outer Diameter in CM 0.467 cm
Outer Diameter in Inches 0.184 inch
Material Latex bonded with silicone elastomer
Tip Soft coned closed tip
Drainage Distally positioned drainage eyelets
Balloon Valve Syringe-luer-operated non-return valve
Size Identification Colour coded
Primary Application Indwelling urinary drainage
Pack Size 10 Catheters

The Microsidd listing confirms 14 FR, Romsons and pack of 10, while Romsons' current product information confirms the Foley Trac construction and functional features.

2-Way Foley Catheter – How It Works

A 2-way Foley catheter has two internal channels or lumens:

Lumen Function
Drainage Lumen Allows urine to drain from the bladder into an appropriate collection system
Balloon Lumen Allows the retention balloon to be inflated or deflated

Once correct placement in the bladder has been established, the balloon is inflated according to the manufacturer's instructions and clinical protocol.

Balloon inflation must never be used as a substitute for confirming correct catheter placement.

Foley Catheter vs Nelaton Catheter

Feature Romsons Foley Trac Nelaton Catheter
Catheter type Indwelling Intermittent/short-term
Retention balloon Yes No
Remains in bladder When clinically indicated Normally removed after drainage
Urine drainage Continuous when connected appropriately Intermittent
Balloon lumen Yes No
Professional insertion Required Clinical instruction/protocol required
Typical purpose Continuous bladder drainage Short-term bladder catheterisation

Romsons describes its Nel Cath as intended for short-term bladder catheterisation, whereas Foley-type catheters incorporate balloon retention for indwelling use.

Frequently Asked Questions

1. What is a Romsons Foley Catheter 14 FR?

It is a 14 French indwelling urinary balloon catheter from Romsons designed for bladder drainage when catheterisation is clinically required.

2. What does 14 FR mean?

14 FR describes the catheter's external diameter using the French sizing system. A 14 FR catheter has an approximate outer diameter of 4.67 mm.

3. Is 14 FR the same as 14 FG?

Yes. In catheter terminology, FR (French) and FG (French Gauge) are commonly used for the same sizing system.

4. Is a 14 FR catheter 14 mm in diameter?

No. This is an important distinction. 14 FR ≈ 4.67 mm, not 14 mm.

5. Is Romsons Foley Trac a 2-way catheter?

The Foley Trac range includes 2-way and 3-way configurations; this listing is for the 2-way 14 FR configuration. Romsons confirms both configurations in its Foley Trac range.

6. What material is the Foley Trac catheter made from?

Romsons specifies latex bonded with silicone elastomer.

7. Is this a 100% silicone Foley catheter?

No. Do not describe Foley Trac as 100% silicone. Romsons' Silko Cath is its 100% silicone Foley catheter; Foley Trac is latex bonded with silicone elastomer.

8. What is the balloon for?

After correct bladder placement, the balloon is appropriately inflated to help retain the indwelling catheter in position.

9. How much should the 14 FR balloon be inflated?

Use only the balloon volume printed on the actual catheter packaging and specified by the manufacturer for that exact variant. Balloon volume should not be guessed from catheter diameter alone.

10. Can a Foley catheter be connected to a urine collection bag?

Yes. An indwelling Foley catheter is typically connected to an appropriate closed urine drainage system when continuous collection is required.

11. Can I use a Romsons urine bag with it?

Romsons offers urine collection systems intended for catheterised patients, including its ROMO range. Compatibility and setup should be confirmed by the healthcare professional managing the catheter.

12. Can this catheter be used at home?

Catheterised patients may receive care at home, but insertion, replacement and management should follow professional medical instructions. Romsons notes urinary catheter use across hospital, nursing-home and home-care settings.

13. Can a patient insert this Foley catheter themselves?

This is an invasive medical device. Insertion should be performed or specifically directed by a trained healthcare professional using appropriate aseptic technique.

14. How long can a Foley catheter remain inserted?

That depends on the catheter material, clinical indication, patient condition and healthcare professional's plan. Do not use a generic number of days as a universal replacement schedule.

15. Can a 14 FR catheter be used for every adult?

No. The correct catheter size is a clinical decision. 14 FR should not automatically be selected simply because the patient is an adult.

16. What is the difference between 14 FR and 16 FR?

The external diameter differs:

14 FR ≈ 4.67 mm
16 FR ≈ 5.33 mm

A healthcare professional should select the appropriate size.

17. Is this catheter reusable?

No. A sterile single-use Foley catheter should not be cleaned and reused.

18. What should I do if urine stops draining?

Kinking, obstruction, positioning problems and other complications are possible. Do not attempt invasive manipulation yourself. Contact the healthcare professional managing the catheter.

19. What symptoms require medical attention?

Seek professional advice for symptoms such as fever, significant pain, new bleeding, lower abdominal discomfort, leakage around the catheter, cloudy/foul-smelling urine accompanied by symptoms, or unexpectedly reduced/absent urine drainage.

20. Where can I buy Romsons Foley Catheter 14 FR online in India?

Romsons Foley Catheter 14 FR is available through Microsidd.com – Romsons Foley Catheter 14 FR, subject to current stock and delivery serviceability. The current listing is a pack of 10.

Why Buy Romsons Foley Catheter 14 FR from Microsidd.com?

Buying Factor Microsidd.com Other Sellers / Marketplaces
Brand identification Romsons Verify seller/listing
Product identification Foley Trac May be unclear
Size 14 FR / FG Verify carefully
Configuration 2 Way May vary
Pack quantity 10 pieces May vary
Catheter specifications Clearly explained Listing dependent
Healthcare-focused catalogue Yes Platform dependent
Urine collection products Available Seller dependent
Related patient-care products Available Seller dependent
GST invoice Available where applicable Seller dependent
Customer support Microsidd support Seller/platform dependent
India-wide ordering Subject to serviceability Seller dependent

About Microsidd India

Microsidd India is a healthcare, medical, diagnostic, laboratory and patient-care products supplier based in Bengaluru, Karnataka, serving healthcare professionals, institutions and customers across India through Microsidd.com.

For GEO/local SEO, this concise entity statement is preferable to repeatedly inserting city names throughout a medical-device page.

No Return / No Exchange Policy

This product is non-returnable and non-exchangeable.

Please verify the Romsons brand, Foley Trac product type, 2-way configuration, 14 FR/FG size, pack quantity and intended clinical requirement before placing your order. Catheter size and type should be selected according to the prescribing or treating healthcare professional's instructions.

Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.

An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.

Medical & Catheter Safety Disclaimer

The Romsons Foley Catheter 14 FR is an invasive medical device. It should be selected, inserted, maintained and removed according to professional medical guidance and appropriate aseptic protocols.

Incorrect catheterisation can cause urethral trauma, bleeding, infection, false passage, blockage and other complications. Urinary catheters can also be associated with catheter-associated urinary tract infection (CAUTI) and other complications. Romsons itself notes that urinary catheters have potential complications that need appropriate management.

Never inflate the balloon before correct catheter placement has been established. Do not reuse a single-use sterile catheter, and do not attempt to replace or remove an indwelling catheter without appropriate instruction.

Didn't find the product you were looking for?