The Erba SGPT ALT/GPT 330 Reagent System Pack is a professional clinical chemistry reagent intended for the quantitative determination of Alanine Aminotransferase (ALT), commonly known as SGPT.
Erba identifies this dedicated system reagent as ALT/GPT 330, catalogue number XSYS0017, using the Modified IFCC method.
This Microsidd listing is for the physical pack configuration R1: 6 × 44 ml + R2: 6 × 12.5 ml and is intended for compatible Erba XL Clinical Chemistry Analysers.
| Product | SGPT / ALT Reagent |
| Brand | Erba Mannheim |
| Pack Name | ALT/GPT 330 |
| Catalogue Number | XSYS0017 |
| R1 Pack | 6 × 44 ml |
| R2 Pack | 6 × 12.5 ml – Microsidd-listed physical pack |
| Method | Modified IFCC |
| Reagent Format | Liquid Stable / Ready to Use |
| Pack Type | Erba SYSPACK™ System Reagent |
| XL-180 / XL-200 / XL-640 | Approx. 1,500 Tests / Kit |
| XL-1000 | Approx. 1,920 Tests / Kit |
| Clinical Category | Liver Function / Enzyme Testing / Clinical Chemistry |
| Intended Use | Professional In-Vitro Diagnostic Use |
| Seller | Microsidd India |
| Location | Bangalore / Bengaluru, Karnataka, India |
SGPT is the older commonly used name for Alanine Aminotransferase (ALT), an intracellular enzyme found predominantly in liver tissue.
ALT is commonly measured as part of:
ALT results should not be interpreted independently and should be considered together with AST, bilirubin, alkaline phosphatase, GGT and other relevant clinical findings.
Erba lists the ALT/GPT 330 reagent as using the Modified IFCC method.
The assay is designed for quantitative determination of ALT enzyme activity according to the manufacturer's validated Erba XL analyser application.
The exact wavelength, sample volume, reagent volumes, reaction timing, calibration and analyser-specific programming should always be taken from the current Erba Mannheim Instructions for Use supplied with the actual reagent lot.
Erba SYSPACK™ reagents are dedicated liquid-stable reagents designed specifically for compatible Erba XL clinical chemistry analysers.
| Component | Microsidd Listing | Current Erba Catalogue |
|---|---|---|
| R1 | 6 × 44 ml | 6 × 44 ml |
| R2 | 6 × 12.5 ml | 6 × 11 ml |
Customers should verify the physical product label before ordering where exact reagent volume is important.
| Erba XL Analyser | Manufacturer-Listed Tests / Kit |
|---|---|
| Erba XL-180 | Approx. 1,500 |
| Erba XL-200 | Approx. 1,500 |
| Erba XL-640 | Approx. 1,500 |
| Erba XL-1000 | Approx. 1,920 |
Actual usable test yield may vary depending on calibration frequency, internal quality-control runs, repeat testing and analyser dead volume.
Compatibility should always be confirmed against the exact analyser model, software configuration and current Erba application documentation.
| Parameter | General Laboratory Relevance |
|---|---|
| ALT / SGPT | Liver-associated aminotransferase |
| AST / SGOT | Hepatic and extra-hepatic enzyme |
| Alkaline Phosphatase | Hepatobiliary and bone-associated enzyme |
| GGT | Hepatobiliary-associated enzyme |
| Total Bilirubin | Overall circulating bilirubin |
| Direct Bilirubin | Predominantly conjugated bilirubin fraction |
| Albumin | Major circulating protein |
| Total Protein | Overall serum protein measurement |
| Feature | SGPT / ALT | SGOT / AST |
|---|---|---|
| Modern Name | ALT | AST |
| Common Older Name | SGPT | SGOT |
| Tissue Distribution | More strongly associated with liver tissue | Liver, heart, skeletal muscle and other tissues |
| Role in LFT | Common hepatocellular enzyme marker | Complementary enzyme marker |
ALT and AST are commonly assessed together and should not be interpreted as stand-alone diagnostic tests.
Laboratories using compatible Erba XL systems can build a broader liver-function reagent panel with:
Browse the dedicated Erba Lab Reagents Collection at Microsidd.com.
This page should be linked reciprocally with the Erba collection and related ALT, AST, bilirubin, ALP and other liver-function reagent pages.
Browse the broader Biochemistry Reagents Collection for liver, renal, lipid, electrolyte and general clinical chemistry reagents from multiple diagnostic brands.
| Microsidd Advantage | Benefit |
|---|---|
| Dedicated Erba Collection | Easy access to compatible Erba XL system reagents |
| Diagnostic / IVD Focus | Professional laboratory-oriented procurement |
| Clear Product Identification | Pack name, catalogue number and method shown clearly |
| Related LFT Reagents | Easier sourcing of liver-function reagents together |
| Technical Product Information | Helps laboratories verify the correct reagent before ordering |
| GST Invoice | Available for eligible purchases |
| Bangalore-Based Operations | Convenient for Bengaluru and Karnataka laboratories |
| India-Wide Supply | Subject to stock availability and serviceability |
Microsidd India supplies Erba clinical chemistry reagents, Liver Function Test reagents and professional laboratory products from Bangalore / Bengaluru, Karnataka.
The Erba ALT/GPT 330 SGPT System Pack is intended for professional laboratories operating compatible Erba XL clinical chemistry analysers.
ALT/GPT 330 is Erba Mannheim's dedicated ALT / SGPT SYSPACK reagent for compatible Erba XL clinical chemistry analysers.
XSYS0017.
Erba lists the method as Modified IFCC.
This Microsidd listing is for R1 6 × 44 ml + R2 6 × 12.5 ml.
Current Erba catalogue literature lists R2 6 × 11 ml, while this Microsidd SKU is based on the physical stock configuration of R2 6 × 12.5 ml. The actual pack label should be used to verify the product supplied.
Erba lists approximately 1,500 tests on XL-180, XL-200 and XL-640, and approximately 1,920 tests on XL-1000.
Yes. SGPT is the older name commonly used for ALT, Alanine Aminotransferase.
Yes, subject to the current Erba application and analyser configuration.
No. It should primarily be treated as a dedicated Erba XL SYSPACK reagent.
Visit the Erba Lab Reagents Collection .
No. It is intended for professional in-vitro diagnostic laboratory use only.
This page is provided for product identification, professional procurement and laboratory education.
ALT / SGPT results should not be interpreted independently to diagnose or exclude liver disease or other medical conditions.
Laboratories must follow the current Erba Mannheim Instructions for Use supplied with the actual reagent lot, including analyser parameters, specimen requirements, calibration, internal quality control, storage and analytical limitations.
This product is non-returnable and non-exchangeable.
Please verify the brand, parameter, catalogue number, method, analyser compatibility and exact R1/R2 pack configuration before ordering.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.