The Erba Bilirubin Total BIL T 330 Reagent System Pack is a professional clinical chemistry reagent intended for the quantitative determination of Total Bilirubin.
Erba identifies this reagent as BIL T 330, catalogue number XSYS0023, using the established Walter & Gerard method.
This listing is for the pack configuration supplied by Microsidd India as R1: 6 × 44 ml + R2: 6 × 12.3 ml.
| Product | Bilirubin Total Reagent |
| Brand | Erba Mannheim |
| Pack Name | BIL T 330 |
| Catalogue Number | XSYS0023 |
| R1 Pack | 6 × 44 ml |
| R2 Pack | 6 × 12.3 ml – as supplied/listed by Microsidd |
| Method | Walter & Gerard |
| Reagent Type | Liquid Stable / Ready to Use |
| Pack Type | Erba SYSPACK™ System Reagent |
| Manufacturer-Listed Test Yield | Approx. 1,500 Tests / Kit |
| Analyser Platform | Compatible Erba XL Clinical Chemistry Analysers |
| Clinical Category | Liver Function / Hepatobiliary / Clinical Chemistry |
| Intended Use | Professional In-Vitro Diagnostic Use |
| Seller | Microsidd India |
| Location | Bangalore / Bengaluru, Karnataka, India |
Bilirubin is a yellow pigment formed primarily during the breakdown of haemoglobin from aged red blood cells.
Total bilirubin represents the combined bilirubin fractions present in blood and is commonly included in routine Liver Function Test (LFT) profiles.
Total bilirubin testing may contribute to laboratory assessment of:
A bilirubin result should always be interpreted together with clinical findings and other laboratory parameters.
Erba identifies the BIL T 330 reagent as using the Walter & Gerard method.
This methodology is used for quantitative bilirubin determination through a photometric clinical chemistry reaction.
The exact analyser wavelength, sample volume, reagent volumes, timing, calibration and application parameters should always be taken from the current Erba Mannheim Instructions for Use supplied with the actual reagent lot.
Erba SYSPACK™ reagents are dedicated clinical chemistry reagent packs developed for compatible Erba XL analyser systems.
| Component | Microsidd Listing | Current Erba Catalogue |
|---|---|---|
| R1 | 6 × 44 ml | 6 × 44 ml |
| R2 | 6 × 12.3 ml | 6 × 11 ml |
Because pack configurations can vary by production version or market, customers should verify the actual pack label supplied before purchase where exact reagent volume is critical.
| Erba XL Analyser | Manufacturer-Listed Tests / Kit |
|---|---|
| Erba XL-180 | Approx. 1,500 |
| Erba XL-200 | Approx. 1,500 |
| Erba XL-640 | Approx. 1,500 |
| Erba XL-1000 | Approx. 1,500 |
Actual usable yield may vary depending on analyser dead volume, calibration, internal quality control and repeat testing.
Always confirm compatibility with the exact analyser model and current Erba application documentation before use.
| Parameter | General Laboratory Relevance |
|---|---|
| Total Bilirubin | Overall circulating bilirubin |
| Direct Bilirubin | Conjugated bilirubin fraction |
| ALT / SGPT | Hepatocellular-associated enzyme |
| AST / SGOT | Hepatic and extra-hepatic enzyme |
| Alkaline Phosphatase | Hepatobiliary and bone-associated enzyme |
| Albumin | Major circulating protein |
| Total Protein | Overall serum protein measurement |
Laboratories using compatible Erba XL systems can build a broader liver-function reagent menu with:
Browse the dedicated Erba Lab Reagents Collection at Microsidd.com.
This collection brings together Erba Mannheim SYSPACK reagents for compatible XL clinical chemistry analysers and should be linked reciprocally with each individual Erba product page.
Browse the wider Biochemistry Reagents Collection for liver, renal, lipid, electrolyte and other clinical chemistry reagents.
| Microsidd Advantage | Benefit |
|---|---|
| Dedicated Erba Collection | Easy access to compatible Erba XL system reagents |
| Diagnostic / IVD Focus | Professional laboratory-oriented procurement |
| Clear Product Identification | Pack name, method and configuration listed clearly |
| Related LFT Reagents | Easier liver-function reagent procurement |
| Technical Product Information | Helps laboratories verify products before ordering |
| GST Invoice | Available for eligible purchases |
| Bangalore-Based Operations | Convenient for Bengaluru and Karnataka laboratories |
| India-Wide Supply | Subject to stock availability and serviceability |
Microsidd India supplies Erba clinical chemistry reagents, Liver Function Test reagents and laboratory diagnostic products from Bangalore / Bengaluru, Karnataka.
The Erba BIL T 330 Bilirubin Total System Pack is intended for professional laboratories using compatible Erba XL chemistry analysers.
It is Erba Mannheim's dedicated Bilirubin Total SYSPACK reagent for compatible XL clinical chemistry analysers.
XSYS0023.
Erba lists the method as Walter & Gerard.
This Microsidd listing is for R1 6 × 44 ml + R2 6 × 12.3 ml. Current Erba catalogue literature lists the R2 component as 6 × 11 ml, so please verify the physical pack label.
Erba lists approximately 1,500 tests per kit on compatible XL analyser platforms.
Yes, subject to the current manufacturer application and analyser configuration.
No. It should primarily be treated as a dedicated Erba XL SYSPACK reagent.
Visit the Erba Lab Reagents Collection .
This information is provided for product identification, procurement and professional laboratory education.
Bilirubin results should not be interpreted independently to diagnose or exclude liver disease, biliary obstruction, haemolysis or other conditions.
Laboratories must follow the current Erba Mannheim Instructions for Use supplied with the actual reagent lot, including analyser settings, calibration, quality control, specimen requirements, storage and analytical limitations.
This product is non-returnable and non-exchangeable.
Please verify the brand, product name, catalogue number, analyser compatibility and exact R1/R2 pack configuration before ordering.
Genuine cases involving an incorrect product received will be handled according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for any claim regarding an incorrect product received.
| Specification name | Specification Value |
|---|---|
| Chemical grade | Laboratory |
| Color pattern | White |