The Erba Bilirubin Direct BIL D 330 Reagent System Pack is a professional clinical chemistry reagent intended for the quantitative determination of Direct Bilirubin.
Erba identifies this reagent as BIL D 330, catalogue number XSYS0028, using the established Walter & Gerard method.
This Microsidd listing is for the pack configuration R1: 6 × 44 ml + R2: 6 × 12.3 ml and is intended for compatible Erba XL Clinical Chemistry Analysers.
| Product | Bilirubin Direct Reagent |
| Brand | Erba Mannheim |
| Pack Name | BIL D 330 |
| Catalogue Number | XSYS0028 |
| R1 Pack | 6 × 44 ml |
| R2 Pack | 6 × 12.3 ml – Microsidd-listed physical pack |
| Method | Walter & Gerard |
| Reagent Type | Liquid Stable / Ready to Use |
| Pack Type | Erba SYSPACK™ System Reagent |
| XL-180 / XL-200 / XL-640 | Approx. 1,200 Tests / Kit |
| XL-1000 | Approx. 1,500 Tests / Kit |
| Clinical Category | Liver Function / Hepatobiliary Chemistry |
| Intended Use | Professional In-Vitro Diagnostic Use |
| Seller | Microsidd India |
| Location | Bangalore / Bengaluru, Karnataka, India |
Direct Bilirubin generally represents the water-soluble, predominantly conjugated bilirubin fraction measured in routine clinical chemistry.
It is commonly evaluated together with Total Bilirubin as part of liver-function and hepatobiliary investigations.
Direct bilirubin testing may be used in laboratory assessment involving:
Direct bilirubin values should not be interpreted alone and should be considered together with total bilirubin, liver enzymes, clinical history and other relevant investigations.
Erba lists BIL D 330 as using the Walter & Gerard method.
The assay provides quantitative photometric measurement of direct bilirubin according to Erba's validated clinical chemistry application.
The exact wavelength, reaction volumes, sample volume, timing, calibration and analyser application should always be taken from the current Erba Mannheim Instructions for Use supplied with the actual reagent lot.
Erba SYSPACK™ reagents are dedicated reagent packs designed for the Erba XL clinical chemistry analyser family.
| Component | Microsidd Listing | Current Erba Catalogue |
|---|---|---|
| R1 | 6 × 44 ml | 6 × 44 ml |
| R2 | 6 × 12.3 ml | 6 × 11 ml |
Customers should verify the physical pack configuration before ordering where exact reagent volume is important.
| Erba XL Analyser | Manufacturer-Listed Tests / Kit |
|---|---|
| Erba XL-180 | Approx. 1,200 |
| Erba XL-200 | Approx. 1,200 |
| Erba XL-640 | Approx. 1,200 |
| Erba XL-1000 | Approx. 1,500 |
Actual test yield can vary according to calibration frequency, quality-control runs, repeat testing and analyser dead volume.
Compatibility should always be confirmed against the exact analyser model and current Erba application documentation.
| Test | What It Measures | Erba System Pack |
|---|---|---|
| Total Bilirubin | Overall measured bilirubin | BIL T 330 |
| Direct Bilirubin | Predominantly conjugated bilirubin fraction | BIL D 330 |
Direct and total bilirubin are commonly interpreted together rather than as isolated laboratory values.
| Parameter | General Laboratory Relevance |
|---|---|
| Total Bilirubin | Overall circulating bilirubin |
| Direct Bilirubin | Predominantly conjugated bilirubin fraction |
| ALT / SGPT | Hepatocellular-associated enzyme |
| AST / SGOT | Hepatic and extra-hepatic enzyme |
| Alkaline Phosphatase | Hepatobiliary and bone-associated enzyme |
| GGT | Hepatobiliary-associated enzyme |
| Albumin | Major circulating protein |
| Total Protein | Overall serum protein measurement |
Laboratories using compatible Erba XL chemistry systems can build a broader LFT reagent menu with:
Browse the dedicated Erba Lab Reagents Collection at Microsidd.com for Erba Mannheim clinical chemistry system-pack reagents.
This Bilirubin Direct page should be linked reciprocally with the Erba collection, Bilirubin Total product, other liver-function reagents and the broader clinical chemistry catalogue.
Browse the broader Biochemistry Reagents Collection for liver, renal, lipid, electrolyte and other clinical chemistry reagents from multiple professional diagnostic brands.
| Microsidd Advantage | Benefit |
|---|---|
| Dedicated Erba Collection | Easy access to related Erba XL system reagents |
| Diagnostic / IVD Focus | Professional laboratory-oriented procurement |
| Pack Details Clearly Listed | Helps reduce ordering errors |
| LFT Reagent Range | Easier sourcing of related liver-function reagents |
| Technical Product Information | Supports product verification before ordering |
| GST Invoice | Available for eligible purchases |
| Bangalore-Based Operations | Convenient for Bengaluru and Karnataka laboratories |
| India-Wide Supply | Subject to stock availability and serviceability |
Microsidd India supplies Erba clinical chemistry reagents, Liver Function Test reagents and laboratory diagnostic products from Bangalore / Bengaluru, Karnataka.
The Erba BIL D 330 Bilirubin Direct System Pack is intended for professional laboratories using compatible Erba XL chemistry analysers.
BIL D 330 is Erba Mannheim's dedicated Bilirubin Direct SYSPACK reagent for compatible XL clinical chemistry analysers.
XSYS0028.
The manufacturer lists the method as Walter & Gerard.
This Microsidd listing is for R1 6 × 44 ml + R2 6 × 12.3 ml.
The current catalogue lists R2 6 × 11 ml, while this Microsidd SKU is based on the physical pack configuration supplied as 6 × 12.3 ml. The actual product label should be used to verify the pack supplied.
Erba currently lists approximately 1,200 tests on XL-180, XL-200 and XL-640, and approximately 1,500 tests on XL-1000.
No. Bilirubin Direct measures a different bilirubin fraction, whereas Bilirubin Total represents the overall measured bilirubin concentration. Both are commonly interpreted together.
Yes, subject to the current manufacturer application and analyser configuration.
No. It should primarily be treated as a dedicated Erba XL SYSPACK reagent.
Visit the Erba Lab Reagents Collection at Microsidd.com.
No. It is intended for professional in-vitro diagnostic laboratory use only.
This information is provided for product identification, professional procurement and laboratory education.
Direct bilirubin results should not be interpreted independently to diagnose or exclude liver disease, biliary obstruction, haemolysis or other medical conditions.
Laboratories must follow the current Erba Mannheim Instructions for Use supplied with the actual reagent lot, including analyser parameters, specimen requirements, calibration, internal quality control, storage and analytical limitations.
This product is non-returnable and non-exchangeable.
Please verify the brand, test parameter, catalogue number, analyser compatibility and exact R1/R2 pack configuration before ordering.
Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law.
An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.
| Specification name | Specification Value |
|---|---|
| Chemical grade | Laboratory |
| Color pattern | White |