{"product_id":"tulip-insight-doa-panel-6-1-drug-test","title":"Tulip Insight DOA Panel 6.1 – 6 Parameter Urine Screening Test | 10 Tests \/ 1 Test","description":"\u003ch2\u003eTulip Insight DOA Panel 6.1 | 6-Parameter Urine Screening Test\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eInsight DOA Panel 6.1\u003c\/strong\u003e by \u003cstrong\u003eTulip Diagnostics\u003c\/strong\u003e is a rapid, qualitative, competitive immunochromatographic test designed for simultaneous screening of six parameters in \u003cstrong\u003ehuman urine\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe panel screens for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTHC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAMP\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBAR\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBZO\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCOC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOPI\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Tulip Diagnostics\u003cbr\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e Insight DOA Panel 6.1\u003cbr\u003e\u003cstrong\u003eMethod:\u003c\/strong\u003e Competitive Immunochromatographic Assay\u003cbr\u003e\u003cstrong\u003eSample:\u003c\/strong\u003e Human Urine\u003cbr\u003e\u003cstrong\u003eResult Type:\u003c\/strong\u003e Qualitative \/ Preliminary Screening\u003cbr\u003e\u003cstrong\u003eTesting Time:\u003c\/strong\u003e Read at approximately 5 minutes; confirm negative results at 8 minutes\u003cbr\u003e\u003cstrong\u003eAvailable Microsidd Variants:\u003c\/strong\u003e 10 Tests \/ 1 Test Loose\u003cbr\u003e\u003cstrong\u003eIntended User:\u003c\/strong\u003e Professional In-Vitro Diagnostic Use\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAvailable Pack Options\u003c\/h2\u003e\n\u003ch3\u003e10-Test Pack\u003c\/h3\u003e\n\u003cp\u003eSuitable for diagnostic laboratories, hospitals, clinics, institutions and other professional testing environments requiring multiple tests.\u003c\/p\u003e\n\u003ch3\u003e1-Test Loose\u003c\/h3\u003e\n\u003cp\u003eMicrosidd also offers a \u003cstrong\u003e1-Test Loose\u003c\/strong\u003e option for professional users requiring a single test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The 1-Test Loose option is a Microsidd unit-sale configuration supplied from the manufacturer's multipack. It is not a separate Tulip retail carton.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e6 Parameters \u0026amp; Analytical Cut-Offs\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCut-Off\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eTHC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003e50 ng\/mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eAMP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003e1000 ng\/mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBAR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003e300 ng\/mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBZO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003e300 ng\/mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCOC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003e300 ng\/mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eOPI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003e300 ng\/mL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003ePrimary Uses \u0026amp; Applications\u003c\/h2\u003e\n\u003cp\u003eInsight DOA Panel 6.1 is intended for professional preliminary screening where simultaneous testing of multiple parameters is required.\u003c\/p\u003e\n\u003cp\u003eTypical applications may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClinical toxicology screening\u003c\/li\u003e\n\u003cli\u003eHospital and diagnostic laboratory testing\u003c\/li\u003e\n\u003cli\u003eEmergency \/ clinical assessment support\u003c\/li\u003e\n\u003cli\u003eProfessional monitoring programmes\u003c\/li\u003e\n\u003cli\u003eInstitutional screening programmes\u003c\/li\u003e\n\u003cli\u003eOccupational screening where legally and ethically permitted\u003c\/li\u003e\n\u003cli\u003eProfessional laboratory screening workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eA preliminary positive result should not be used by itself for employment, legal, disciplinary, forensic or other consequential decisions.\u003c\/strong\u003e Appropriate confirmatory testing and professional interpretation are required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eHow Insight DOA Panel 6.1 Works\u003c\/h2\u003e\n\u003cp\u003eThe test works by \u003cstrong\u003ecompetitive immunochromatography\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEach parameter-specific test area contains reagents that interact with compounds present in the urine specimen.\u003c\/p\u003e\n\u003cp\u003eAs the sample migrates through the membrane by capillary action, the presence or absence of sufficient target compound affects whether the corresponding test line develops.\u003c\/p\u003e\n\u003ch3\u003eImportant – Interpretation Is Opposite to Many Other Rapid Tests\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTwo lines (C + T) = Negative\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOnly Control line (C) = Preliminary Positive\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis interpretation pattern is a key feature of competitive screening assays and should be understood before testing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eHow to Use Insight DOA Panel 6.1\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFor professional use. Follow the current Tulip IFU supplied with the test.\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eBring the test device and urine specimen to room temperature before testing.\u003c\/li\u003e\n\u003cli\u003eOpen the foil pouch by tearing at the notch.\u003c\/li\u003e\n\u003cli\u003eRemove the test device, sample applicator and desiccant.\u003c\/li\u003e\n\u003cli\u003eCheck the desiccant indicator.\u003c\/li\u003e\n\u003cli\u003eIf the desiccant indicator is pink or colourless, do not use that device.\u003c\/li\u003e\n\u003cli\u003ePlace the device on a flat horizontal surface.\u003c\/li\u003e\n\u003cli\u003eLabel the test with the specimen \/ patient identification.\u003c\/li\u003e\n\u003cli\u003eCollect urine in a clean, dry container.\u003c\/li\u003e\n\u003cli\u003eUsing the supplied applicator, fill urine exactly to the \u003cstrong\u003e0.5 mark\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDispense the full sample into the sample well marked \u003cstrong\u003eS\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAlternatively, use approximately \u003cstrong\u003e500 µL urine\u003c\/strong\u003e with a suitable micropipette.\u003c\/li\u003e\n\u003cli\u003eAvoid introducing air bubbles into the sample well.\u003c\/li\u003e\n\u003cli\u003eStart the timer.\u003c\/li\u003e\n\u003cli\u003eRead the parameter windows at approximately \u003cstrong\u003e5 minutes\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm apparently negative results at \u003cstrong\u003e8 minutes\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDo not interpret the device after 8 minutes.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eHow to Read the Result\u003c\/h2\u003e\n\u003ch3\u003eNegative\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTwo pink bands appear:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl line – C\u003c\/li\u003e\n\u003cli\u003eTest line – T\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis indicates that the corresponding parameter has not been detected at or above the assay cut-off.\u003c\/p\u003e\n\u003ch3\u003ePreliminary Positive\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOnly the Control line C appears.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe absence of the corresponding T line indicates that the parameter may be present at or above the stated cut-off.\u003c\/p\u003e\n\u003ch3\u003eInvalid\u003c\/h3\u003e\n\u003cp\u003eIf the required Control line does not appear, the test is invalid.\u003c\/p\u003e\n\u003cp\u003eRepeat using a new Insight DOA Panel 6.1 device.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhat Does a Faint Test Line Mean?\u003c\/h2\u003e\n\u003cp\u003eTulip's IFU states that a very faint Test line may occur when the concentration is close to the assay cut-off.\u003c\/p\u003e\n\u003cp\u003eSuch samples should be:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRe-tested, and\/or\u003c\/li\u003e\n\u003cli\u003eConfirmed using a more specific analytical method before a positive determination is made.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecimen Requirements\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecimen:\u003c\/strong\u003e Human urine.\u003c\/p\u003e\n\u003cp\u003eTulip specifies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo special preparation is required before specimen collection.\u003c\/li\u003e\n\u003cli\u003eCollect urine in a clean, dry glass or plastic container.\u003c\/li\u003e\n\u003cli\u003eFresh urine is preferred.\u003c\/li\u003e\n\u003cli\u003eIf testing is delayed, urine may be stored at \u003cstrong\u003e2–8°C for up to approximately 24 hours\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eBring refrigerated specimens to room temperature before testing.\u003c\/li\u003e\n\u003cli\u003eAvoid repeated freezing and thawing.\u003c\/li\u003e\n\u003cli\u003eSamples containing precipitates or particulate matter should be appropriately clarified according to the IFU.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eStorage \u0026amp; Stability\u003c\/h2\u003e\n\u003cp\u003eStore sealed Insight DOA Panel 6.1 devices at:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4°C to 30°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDo not freeze.\u003c\/li\u003e\n\u003cli\u003eKeep each device sealed until use.\u003c\/li\u003e\n\u003cli\u003eUse immediately after opening the foil pouch.\u003c\/li\u003e\n\u003cli\u003eDo not use after the printed expiry date.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer's quick-reference information lists unopened-kit stability of approximately \u003cstrong\u003e18 months at 4–30°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eThe expiry printed on the actual supplied pouch \/ carton is the final reference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous 6-parameter urine screening\u003c\/li\u003e\n\u003cli\u003eTHC + AMP + BAR + BZO + COC + OPI\u003c\/li\u003e\n\u003cli\u003eCompetitive immunochromatographic method\u003c\/li\u003e\n\u003cli\u003eQualitative visual interpretation\u003c\/li\u003e\n\u003cli\u003eApprox. 5-minute initial result\u003c\/li\u003e\n\u003cli\u003eNegative-result confirmation at 8 minutes\u003c\/li\u003e\n\u003cli\u003eApprox. 500 µL urine required\u003c\/li\u003e\n\u003cli\u003eNo specialised analyser required for visual reading\u003c\/li\u003e\n\u003cli\u003eIndividually pouched devices\u003c\/li\u003e\n\u003cli\u003eBuilt-in procedural Control line\u003c\/li\u003e\n\u003cli\u003eProfessional IVD screening format\u003c\/li\u003e\n\u003cli\u003eStorage at 4–30°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of a 6-Parameter Panel\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Parameters:\u003c\/strong\u003e Six parameters screened using one urine specimen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid:\u003c\/strong\u003e Initial results in approximately 5 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient:\u003c\/strong\u003e Uses a urine specimen rather than blood collection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact:\u003c\/strong\u003e No large analyser required for visual interpretation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Parameter Windows:\u003c\/strong\u003e Each parameter can be interpreted independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Control:\u003c\/strong\u003e Control line helps verify test migration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Screening:\u003c\/strong\u003e Useful as a preliminary analytical tool before confirmatory testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eImportant Test Limitations\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eInsight DOA Panel 6.1 provides a preliminary qualitative analytical screening result only.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA preliminary positive result does not establish intoxication.\u003c\/li\u003e\n\u003cli\u003eThe test does not quantify the concentration present.\u003c\/li\u003e\n\u003cli\u003eA negative result does not prove that exposure has never occurred.\u003c\/li\u003e\n\u003cli\u003eDetection duration can vary with amount, frequency, metabolism, excretion and individual factors.\u003c\/li\u003e\n\u003cli\u003ePrescription medicines, over-the-counter products or other substances may affect screening results.\u003c\/li\u003e\n\u003cli\u003eTechnical or procedural errors may cause incorrect results.\u003c\/li\u003e\n\u003cli\u003eSuspected adulterated specimens should be re-tested using a newly collected sample.\u003c\/li\u003e\n\u003cli\u003eClinical or consequential decisions must not be based solely on a single rapid-screening result.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTulip's IFU specifies that preliminary positive results should be evaluated using a more specific confirmatory analytical method.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eInsight DOA Panel 6.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTulip Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e6-Parameter Urine Screening Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCompetitive Immunochromatographic Assay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eParameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTHC, AMP, BAR, BZO, COC, OPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eNumber of Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSpecimen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHuman Urine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 500 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eTHC Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e50 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eAMP Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBAR Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e300 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBZO Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e300 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCOC Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e300 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eOPI Cut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e300 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eResult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eQualitative \/ Preliminary Screening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eInitial Reading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 5 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eNegative Confirmation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e8 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMaximum Interpretation Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDo Not Interpret After 8 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e4–30°C; Do Not Freeze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMicrosidd Pack Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10 Tests \/ 1 Test Loose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eIntended Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eProfessional In-Vitro Diagnostic Screening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy Insight DOA Panel 6.1 from Microsidd India?\u003c\/h2\u003e\n\u003cp\u003eMulti-parameter urine screening panels can vary by \u003cstrong\u003eparameter combination, analytical cut-off, specimen type, pack quantity and interpretation method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMicrosidd clearly identifies this listing as \u003cstrong\u003eTulip Insight DOA Panel 6.1 – THC + AMP + BAR + BZO + COC + OPI – 6-Parameter Urine Screening Panel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMicrosidd India\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eGeneral Online Store\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTypical Offline Store\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eExact Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAll 6 parameters clearly identified\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eListing detail may vary\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRequires pack verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCut-Off Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eManufacturer cut-offs clearly displayed\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOften omitted\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMay require IFU review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePack Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10 Tests + 1-Test Loose option\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller dependent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDepends on stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMethod Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eProcedure and interpretation clearly explained\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eVaries by seller\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUsually verbal guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eGST Invoice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller dependent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eStore dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBengaluru Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRT Nagar, Bengaluru\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller may be elsewhere\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLocal supplier dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eIndia-Wide Ordering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAvailable to serviceable locations\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePlatform dependent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUsually local purchase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eWhere to Buy Insight DOA Panel 6.1 in Bangalore?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTulip Insight DOA Panel 6.1 is available from Microsidd India, RT Nagar, Bengaluru\u003c\/strong\u003e, subject to current stock, batch and expiry availability.\u003c\/p\u003e\n\u003cp\u003eCustomers searching for \u003cstrong\u003eInsight DOA Panel 6.1 Bangalore\u003c\/strong\u003e, 6-parameter urine screening test Bengaluru, DOA panel near me, professional urine screening panel RT Nagar, Tulip screening kit Bangalore or laboratory screening test supplier Karnataka can check current availability through Microsidd.com.\u003c\/p\u003e\n\u003cp\u003eProfessional laboratories and institutions requiring multiple packs should confirm current batch, expiry and quantity before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMicrosidd India – NAP\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBusiness Name:\u003c\/strong\u003e Microsidd India\u003cbr\u003e\u003cstrong\u003eAddress:\u003c\/strong\u003e #09 Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India\u003cbr\u003e\u003cstrong\u003ePhone \/ WhatsApp:\u003c\/strong\u003e +91 63667 72288\u003cbr\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e support@microsidd.com\u003cbr\u003e\u003cstrong\u003eWebsite:\u003c\/strong\u003e https:\/\/microsidd.com\u003cbr\u003e\u003cstrong\u003eWorking Hours:\u003c\/strong\u003e Monday to Saturday, 10:00 AM – 6:00 PM IST\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/share.google\/NWhhEfmvlEyIfAShq\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cstrong\u003eView Microsidd India on Google Maps\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eFor Bengaluru ordering information, visit \u003ca href=\"https:\/\/microsidd.com\/pages\/microsidd-india-bangalore\"\u003e\u003cstrong\u003eMicrosidd India – Medical \u0026amp; Laboratory Supplies Bangalore\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions – Insight DOA Panel 6.1\u003c\/h2\u003e\n\u003ch3\u003eWhat does Insight DOA Panel 6.1 screen?\u003c\/h3\u003e\n\u003cp\u003eIt simultaneously screens six parameters: \u003cstrong\u003eTHC, AMP, BAR, BZO, COC and OPI\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow many parameters does the panel test?\u003c\/h3\u003e\n\u003cp\u003eSix.\u003c\/p\u003e\n\u003ch3\u003eWhat specimen is required?\u003c\/h3\u003e\n\u003cp\u003eHuman urine.\u003c\/p\u003e\n\u003ch3\u003eHow much urine is required?\u003c\/h3\u003e\n\u003cp\u003eApproximately \u003cstrong\u003e500 µL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow quickly is the result available?\u003c\/h3\u003e\n\u003cp\u003eInitial results are read at approximately 5 minutes. Tulip advises confirming negative results at 8 minutes and not interpreting the device after 8 minutes.\u003c\/p\u003e\n\u003ch3\u003eWhat does two lines mean?\u003c\/h3\u003e\n\u003cp\u003eTwo lines — Control and Test — indicate a \u003cstrong\u003enegative\u003c\/strong\u003e result for that parameter.\u003c\/p\u003e\n\u003ch3\u003eWhat does only one Control line mean?\u003c\/h3\u003e\n\u003cp\u003eA Control line without a corresponding Test line represents a \u003cstrong\u003epreliminary positive\u003c\/strong\u003e result for that parameter.\u003c\/p\u003e\n\u003ch3\u003eWhy does a preliminary positive result have fewer lines?\u003c\/h3\u003e\n\u003cp\u003eThis is a competitive immunochromatographic assay. When sufficient target compound is present, formation of the corresponding Test line is inhibited.\u003c\/p\u003e\n\u003ch3\u003eWhat does a faint Test line mean?\u003c\/h3\u003e\n\u003cp\u003eA faint Test line may occur when the concentration is close to the assay cut-off. Follow the Tulip IFU regarding re-testing and confirmation.\u003c\/p\u003e\n\u003ch3\u003eDoes a preliminary positive result establish misuse or intoxication?\u003c\/h3\u003e\n\u003cp\u003eNo. The test provides a preliminary qualitative analytical result only. Appropriate confirmatory testing and professional interpretation are required.\u003c\/p\u003e\n\u003ch3\u003eCan the test determine the concentration present?\u003c\/h3\u003e\n\u003cp\u003eNo. This is a qualitative screening test, not a quantitative assay.\u003c\/p\u003e\n\u003ch3\u003eCan the test determine when exposure occurred?\u003c\/h3\u003e\n\u003cp\u003eNo. Detection duration varies according to multiple individual and analytical factors.\u003c\/p\u003e\n\u003ch3\u003eWhat are the cut-offs?\u003c\/h3\u003e\n\u003cp\u003eTHC 50 ng\/mL; AMP 1000 ng\/mL; BAR 300 ng\/mL; BZO 300 ng\/mL; COC 300 ng\/mL; OPI 300 ng\/mL.\u003c\/p\u003e\n\u003ch3\u003eHow should the test be stored?\u003c\/h3\u003e\n\u003cp\u003eStore sealed devices at \u003cstrong\u003e4–30°C\u003c\/strong\u003e. Do not freeze.\u003c\/p\u003e\n\u003ch3\u003eHow should urine be stored if testing is delayed?\u003c\/h3\u003e\n\u003cp\u003eFresh urine is preferred. Tulip permits approximately 2–8°C storage for up to 24 hours when necessary. Bring refrigerated urine to room temperature before testing.\u003c\/p\u003e\n\u003ch3\u003eCan the device be reused?\u003c\/h3\u003e\n\u003cp\u003eNo. Each device is intended for single use.\u003c\/p\u003e\n\u003ch3\u003eCan the pouch be opened in advance?\u003c\/h3\u003e\n\u003cp\u003eNo. Use the device immediately after opening the foil pouch.\u003c\/p\u003e\n\u003ch3\u003eIs this suitable for home self-testing?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer identifies the product for \u003cstrong\u003eprofessional in-vitro diagnostic use\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eIs a 1-Test option available?\u003c\/h3\u003e\n\u003cp\u003eYes. Microsidd offers a 1-Test Loose option in addition to the 10-Test pack. The loose option is supplied from the manufacturer's multipack and is not a separate Tulip retail carton.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Insight DOA Panel 6.1 in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eIt can be ordered through Microsidd India in RT Nagar, Bengaluru, subject to current stock, batch and expiry availability.\u003c\/p\u003e\n\u003ch3\u003eDoes Microsidd deliver outside Bengaluru?\u003c\/h3\u003e\n\u003cp\u003eYes. Microsidd supplies professional medical and laboratory products to serviceable locations across India, subject to stock and courier serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMedical \u0026amp; Diagnostic Disclaimer\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eInsight DOA Panel 6.1 is an in-vitro diagnostic screening device intended for professional use.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe test provides a \u003cstrong\u003epreliminary qualitative analytical result only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA preliminary positive result:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDoes not independently establish misuse\u003c\/li\u003e\n\u003cli\u003eDoes not establish intoxication\u003c\/li\u003e\n\u003cli\u003eDoes not quantify the concentration present\u003c\/li\u003e\n\u003cli\u003eDoes not determine the timing of exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePrescription medicines, over-the-counter medicines, interfering compounds, specimen adulteration, procedural errors and other factors may affect screening results.\u003c\/p\u003e\n\u003cp\u003ePreliminary positive or clinically inconsistent results should be confirmed using an appropriate more-specific analytical method according to laboratory practice and the Tulip IFU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNo employment, legal, disciplinary, forensic, treatment or other consequential decision should be based solely on an unconfirmed rapid-screening result.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFinal interpretation should be performed by appropriately qualified healthcare \/ laboratory professionals together with relevant clinical and laboratory information.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eNo Return \/ No Exchange – Verify Panel, Pack \u0026amp; Intended Use Before Ordering\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis is an expiry-sensitive professional diagnostic test kit.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Tulip Diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Insight DOA Panel 6.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameters:\u003c\/strong\u003e THC + AMP + BAR + BZO + COC + OPI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecimen:\u003c\/strong\u003e Human Urine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack Variant:\u003c\/strong\u003e 10 Tests or 1 Test Loose\u003c\/li\u003e\n\u003cli\u003eRequired analytical cut-offs\u003c\/li\u003e\n\u003cli\u003eProfessional-use requirement\u003c\/li\u003e\n\u003cli\u003eCurrent batch and expiry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA correctly supplied diagnostic kit cannot normally be returned or exchanged because the wrong parameter combination, pack size, specimen type or test method was selected.\u003c\/p\u003e\n\u003cp\u003eDiagnostic tests are hygiene-sensitive, contamination-sensitive, storage-sensitive and expiry-sensitive consumables and cannot normally be returned to saleable inventory after correct delivery.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving incorrect supply, verified transit damage, materially misdescribed goods, defects or remedies required under applicable Indian law will be handled according to the \u003ca href=\"https:\/\/microsidd.com\/pages\/cancellation-and-refunds\"\u003e\u003cstrong\u003eMicrosidd Refund, Return, Replacement \u0026amp; Cancellation Policy\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for delivery-related claims involving an incorrect, missing or damaged product.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBegin recording before opening the parcel. Open the outer carton carefully by \u003cstrong\u003ecutting the sealing tape with a blade or suitable cutter; do not tear the carton\u003c\/strong\u003e. Keep the courier label, sealed test pouches, product name, pack quantity, batch and expiry continuously visible.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTulip Insight DOA Panel 6.1 – Product Entity Summary\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e Insight DOA Panel 6.1\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Tulip Diagnostics\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e 6-Parameter Urine Screening Test\u003cbr\u003e\u003cstrong\u003eMethod:\u003c\/strong\u003e Competitive Immunochromatography\u003cbr\u003e\u003cstrong\u003eParameters:\u003c\/strong\u003e THC, AMP, BAR, BZO, COC, OPI\u003cbr\u003e\u003cstrong\u003eSpecimen:\u003c\/strong\u003e Human Urine\u003cbr\u003e\u003cstrong\u003eSample Volume:\u003c\/strong\u003e Approx. 500 µL\u003cbr\u003e\u003cstrong\u003eTHC Cut-Off:\u003c\/strong\u003e 50 ng\/mL\u003cbr\u003e\u003cstrong\u003eAMP Cut-Off:\u003c\/strong\u003e 1000 ng\/mL\u003cbr\u003e\u003cstrong\u003eBAR Cut-Off:\u003c\/strong\u003e 300 ng\/mL\u003cbr\u003e\u003cstrong\u003eBZO Cut-Off:\u003c\/strong\u003e 300 ng\/mL\u003cbr\u003e\u003cstrong\u003eCOC Cut-Off:\u003c\/strong\u003e 300 ng\/mL\u003cbr\u003e\u003cstrong\u003eOPI Cut-Off:\u003c\/strong\u003e 300 ng\/mL\u003cbr\u003e\u003cstrong\u003eResult:\u003c\/strong\u003e Preliminary Qualitative Screening\u003cbr\u003e\u003cstrong\u003eInitial Reading:\u003c\/strong\u003e Approx. 5 Minutes\u003cbr\u003e\u003cstrong\u003eNegative Confirmation:\u003c\/strong\u003e 8 Minutes\u003cbr\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e 4–30°C; Do Not Freeze\u003cbr\u003e\u003cstrong\u003eMicrosidd Pack Options:\u003c\/strong\u003e 10 Tests \/ 1 Test Loose\u003cbr\u003e\u003cstrong\u003eIntended User:\u003c\/strong\u003e Professional IVD Use\u003cbr\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Microsidd India\u003cbr\u003e\u003cstrong\u003eSeller Location:\u003c\/strong\u003e RT Nagar, Bengaluru, Karnataka, India\u003c\/p\u003e","brand":"Tulip","offers":[{"title":"1 Test Kit","offer_id":68094621679936,"sku":null,"price":299.0,"currency_code":"INR","in_stock":true},{"title":"10 Test Kit","offer_id":68094621712704,"sku":null,"price":2490.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/Tulip_Insight_DOA_Panel_6.1_six_parameter_urine_screening_test.png?v=1794464994","url":"https:\/\/microsidd.com\/products\/tulip-insight-doa-panel-6-1-drug-test","provider":"Microsidd India","version":"1.0","type":"link"}