{"product_id":"triglycerides-liquid-stable-reagent","title":"Triglycerides Liquid Stable Reagent – 50 ml \u0026 2 × 50 ml | GPO-PAP Method","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed Triglycerides Liquid Stable Reagent\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Triglycerides Liquid Stable Reagent\u003c\/strong\u003e is a professional clinical biochemistry reagent intended for the \u003cstrong\u003equantitative photometric determination of triglycerides\u003c\/strong\u003e using the \u003cstrong\u003eGPO-PAP enzymatic endpoint method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is available in \u003cstrong\u003e50 ml and 2 × 50 ml variants\u003c\/strong\u003e and is suitable for routine lipid-profile testing in pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories.\u003c\/p\u003e\n\u003cp\u003eSwemed identifies Triglycerides as a \u003cstrong\u003eGPO-PAP method\u003c\/strong\u003e assay for serum and plasma specimens, including EDTA and heparin plasma. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe reagent is suitable for compatible \u003cstrong\u003eopen-system fully automatic and semi-automatic biochemistry analysers\u003c\/strong\u003e that allow user-programmable assay parameters, subject to analyser compatibility and laboratory validation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAvailable Pack Sizes\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eVariant\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003ePack Size\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwemed Triglycerides Reagent\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 ml\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwemed Triglycerides Reagent\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 × 50 ml\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct at a Glance\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eTriglycerides Liquid Stable Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Pack Sizes\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 ml, 2 × 50 ml\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eTriglycerides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGPO-PAP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Type\u003c\/td\u003e\n\u003ctd\u003eEnzymatic \/ Photometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Mode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum \/ Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlasma Types\u003c\/td\u003e\n\u003ctd\u003eEDTA \/ Heparin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Concentration\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 minutes at room temperature or 10 minutes at 37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 1000 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Preparation\u003c\/td\u003e\n\u003ctd\u003eReady to Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyser Compatibility\u003c\/td\u003e\n\u003ctd\u003eOpen-system Fully Automatic \u0026amp; Semi-Automatic Analysers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eProfessional In Vitro Diagnostic Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru, Karnataka, India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe wavelength, reagent volume, sample volume, incubation, standard concentration and linearity above are taken from the Swemed technical insert. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics Triglycerides Reagent\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAvailable in \u003cstrong\u003e50 ml and 2 × 50 ml\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGPO-PAP enzymatic method\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eReady-to-use reagent\u003c\/li\u003e\n\u003cli\u003eReady-to-use triglyceride standard\u003c\/li\u003e\n\u003cli\u003eEndpoint photometric assay\u003c\/li\u003e\n\u003cli\u003eRecommended wavelength: \u003cstrong\u003e505 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eStandard concentration: \u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample volume: \u003cstrong\u003e10 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReagent volume: \u003cstrong\u003e1000 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLinearity up to \u003cstrong\u003e1000 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for serum and compatible plasma samples\u003c\/li\u003e\n\u003cli\u003eSuitable for lipid-profile testing\u003c\/li\u003e\n\u003cli\u003eSuitable for compatible \u003cstrong\u003eopen-system fully automatic analysers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for compatible \u003cstrong\u003eopen-system semi-automatic analysers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Benefits\u003c\/h1\u003e\n\u003ch2\u003eGPO-PAP Enzymatic Method\u003c\/h2\u003e\n\u003cp\u003eThe Swemed Triglycerides assay uses an enzymatic sequence in which triglycerides are hydrolysed, and subsequent reactions generate hydrogen peroxide. In the presence of peroxidase, a coloured quinoneimine compound is formed, and the intensity of the colour is proportional to the triglyceride concentration in the sample. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReady-to-Use Reagent System\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer technical insert lists both the \u003cstrong\u003eTriglyceride Reagent and Triglyceride Standard as ready to use\u003c\/strong\u003e, helping simplify routine laboratory workflow. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eHigh Linearity\u003c\/h2\u003e\n\u003cp\u003eThe assay is stated to be linear up to \u003cstrong\u003e1000 mg\/dL\u003c\/strong\u003e, providing a practical analytical range for routine triglyceride testing. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eOpen-System Analyser Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe reagent can be used on compatible \u003cstrong\u003eopen-system semi-automatic and fully automatic biochemistry analysers\u003c\/strong\u003e that permit programming of endpoint chemistry parameters such as wavelength, sample volume, reagent volume, temperature and incubation.\u003c\/p\u003e\n\u003ch2\u003eUseful for Routine Lipid Profiles\u003c\/h2\u003e\n\u003cp\u003eTriglycerides are commonly measured together with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Cholesterol\u003c\/li\u003e\n\u003cli\u003eHDL Cholesterol\u003c\/li\u003e\n\u003cli\u003eLDL Cholesterol\u003c\/li\u003e\n\u003cli\u003eVLDL estimation\u003c\/li\u003e\n\u003cli\u003eOther lipid-related parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eCompatible with Open-System Biochemistry Analysers\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Triglycerides Reagent\u003c\/strong\u003e is suitable for use on compatible open-system analysers where laboratories can program the required assay settings.\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eAnalyser Parameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSwemed Triglycerides Setting\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e15 min at room temperature or 10 min at 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eAgainst Reagent Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003emg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe laboratory should verify analyser compatibility and validate the programmed application before reporting patient results. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eIntended Use\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Triglycerides Liquid Stable Reagent\u003c\/strong\u003e is intended for the quantitative determination of triglycerides in serum and suitable plasma specimens by an enzymatic photometric GPO-PAP method.\u003c\/p\u003e\n\u003cp\u003eSwemed lists triglycerides for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSerum\u003c\/li\u003e\n\u003cli\u003ePlasma\u003c\/li\u003e\n\u003cli\u003eEDTA plasma\u003c\/li\u003e\n\u003cli\u003eHeparin plasma \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic laboratory use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTest Principle\u003c\/h1\u003e\n\u003cp\u003eTriglycerides are hydrolysed by lipoprotein lipase to form \u003cstrong\u003eglycerol and free fatty acids\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe glycerol undergoes further enzymatic reactions involving glycerol kinase and glycerol phosphate oxidase, producing \u003cstrong\u003ehydrogen peroxide\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn the presence of peroxidase, hydrogen peroxide reacts with the chromogen to form a coloured \u003cstrong\u003equinoneimine compound\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe intensity of the resulting colour is proportional to the triglyceride concentration in the specimen. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTest Parameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eTriglycerides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eGPO-PAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette\u003c\/td\u003e\n\u003ctd\u003e10 mm path length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eAgainst Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Concentration\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation at Room Temperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 minutes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation at 37°C\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 minutes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003emg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eAssay Procedure Summary\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTube\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eReagent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStandard \/ Sample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e10 µl Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e10 µl Sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eMix and incubate for:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e15 minutes at room temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10 minutes at 37°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRead the absorbance of the standard and test against the reagent blank at \u003cstrong\u003e505 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCalculation\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eTriglycerides (mg\/dL) = Absorbance of Sample ÷ Absorbance of Standard × Concentration of Standard\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manufacturer states a standard concentration of \u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Requirements\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer recommends:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFresh specimen\u003c\/li\u003e\n\u003cli\u003eClear sample\u003c\/li\u003e\n\u003cli\u003eNon-haemolysed serum\u003c\/li\u003e\n\u003cli\u003eFasting patient sample where clinically appropriate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSwemed also notes that blood-collection devices lubricated with \u003cstrong\u003eglycerin \/ glycerol should not be used\u003c\/strong\u003e, because glycerol can interfere with triglyceride measurement. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Stability\u003c\/h1\u003e\n\u003cp\u003eThe Swemed technical insert states that triglycerides in serum remain stable for approximately:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eStorage Condition\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3 days\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eProlonged storage at room temperature is discouraged because hydrolysis of glycerol-containing compounds can produce an apparent increase in measured triglycerides. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eInterfering Substances\u003c\/h1\u003e\n\u003cp\u003eSwemed identifies the following as potential interfering substances:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeparin\u003c\/li\u003e\n\u003cli\u003eEDTA\u003c\/li\u003e\n\u003cli\u003eFluoride\u003c\/li\u003e\n\u003cli\u003eOxalate\u003c\/li\u003e\n\u003cli\u003eCitrate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe insert states these may inhibit the triglyceride assay and should be avoided in the manufacturer procedure. Lipemic or grossly icteric samples may also produce falsely elevated results. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eBecause Swemed’s broader product listing describes EDTA and heparin plasma as supported sample types, laboratories should follow the \u003cstrong\u003ecurrent insert supplied with the actual reagent lot and their validated analyser application\u003c\/strong\u003e where specimen guidance differs. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMeasuring Range and Linearity\u003c\/h1\u003e\n\u003cp\u003eThe Swemed Triglycerides assay is stated to be linear up to:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1000 mg\/dL\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSamples exceeding the validated measuring range should be handled according to the current manufacturer instructions and the laboratory’s validated dilution procedure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManufacturer Expected Values\u003c\/h1\u003e\n\u003cp\u003eThe Swemed insert provides the following expected range:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Expected Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTriglycerides\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36–165 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eReference intervals can differ according to population, fasting status, laboratory method and clinical guidelines. Each laboratory should establish or verify an appropriate reference interval for its own patient population. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy Triglycerides Testing Is Important\u003c\/h1\u003e\n\u003cp\u003eTriglycerides are esters of fatty acids and glycerol and represent an important form of lipid storage and transport in the body.\u003c\/p\u003e\n\u003cp\u003eTriglyceride testing is commonly used as part of investigations involving:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLipid-profile evaluation\u003c\/li\u003e\n\u003cli\u003eHypertriglyceridaemia\u003c\/li\u003e\n\u003cli\u003eDyslipidaemia\u003c\/li\u003e\n\u003cli\u003eCardiovascular-risk assessment\u003c\/li\u003e\n\u003cli\u003eDiabetes mellitus\u003c\/li\u003e\n\u003cli\u003eMetabolic disorders\u003c\/li\u003e\n\u003cli\u003eEndocrine disturbances\u003c\/li\u003e\n\u003cli\u003eNephrotic conditions\u003c\/li\u003e\n\u003cli\u003eFollow-up of lipid-management programmes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSwemed notes that triglyceride testing is useful in the assessment of primary and secondary hyperlipoproteinaemia and may also be relevant in diabetes, nephrosis, biliary obstruction and metabolic abnormalities. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTriglycerides in a Lipid Profile\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLaboratory Relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cholesterol\u003c\/td\u003e\n\u003ctd\u003eOverall cholesterol measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHDL Cholesterol\u003c\/td\u003e\n\u003ctd\u003eHigh-density lipoprotein cholesterol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLDL Cholesterol\u003c\/td\u003e\n\u003ctd\u003eLow-density lipoprotein cholesterol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTriglycerides\u003c\/td\u003e\n\u003ctd\u003eCirculating triglyceride concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLDL\u003c\/td\u003e\n\u003ctd\u003eOften estimated from triglyceride values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eWho Can Buy This Product?\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine triglyceride testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eLipid profile investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCardiology Centres\u003c\/td\u003e\n\u003ctd\u003eLipid and cardiovascular-risk profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiabetes Care Centres\u003c\/td\u003e\n\u003ctd\u003eMetabolic and lipid testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreventive Health Centres\u003c\/td\u003e\n\u003ctd\u003eRoutine lipid-profile screening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine enzymatic testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and teaching use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eInstitutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional supply where permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eUseful Tips Before Ordering\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that \u003cstrong\u003eTriglycerides – GPO-PAP Method\u003c\/strong\u003e is required.\u003c\/li\u003e\n\u003cli\u003eChoose the correct pack: \u003cstrong\u003e50 ml or 2 × 50 ml\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm your analyser is an \u003cstrong\u003eopen system\u003c\/strong\u003e before programming third-party reagents.\u003c\/li\u003e\n\u003cli\u003eEnsure the analyser supports \u003cstrong\u003e505 nm endpoint measurement\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm 1000 µl reagent and 10 µl sample programming.\u003c\/li\u003e\n\u003cli\u003eVerify the standard concentration: \u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFollow current manufacturer instructions for sample type.\u003c\/li\u003e\n\u003cli\u003eUse fresh and properly handled specimens.\u003c\/li\u003e\n\u003cli\u003eAvoid glycerol-contaminated sample-collection equipment.\u003c\/li\u003e\n\u003cli\u003ePerform calibration and internal quality control before routine use.\u003c\/li\u003e\n\u003cli\u003eVerify analyser application and method performance before reporting patient results.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eBuy Swemed Triglycerides Reagent in Bangalore\u003c\/h1\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003elipid-profile reagents, clinical chemistry reagents and laboratory products from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Triglycerides Liquid Stable Reagent\u003c\/strong\u003e is available in \u003cstrong\u003e50 ml and 2 × 50 ml pack variants\u003c\/strong\u003e and is suitable for pathology laboratories, diagnostic centres, hospitals and clinical chemistry facilities using compatible open-system analysers.\u003c\/p\u003e\n\u003cp\u003eThe product can be ordered through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e, subject to stock availability and serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSearch Relevance\u003c\/h1\u003e\n\u003cp\u003eThis product is relevant for buyers searching for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTriglycerides reagent supplier in Bangalore\u003c\/li\u003e\n\u003cli\u003eSwemed Triglycerides Reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eTriglycerides GPO PAP reagent Bengaluru\u003c\/li\u003e\n\u003cli\u003eTriglyceride reagent 50 ml\u003c\/li\u003e\n\u003cli\u003eTriglycerides reagent 2 × 50 ml\u003c\/li\u003e\n\u003cli\u003eLipid profile reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eTriglyceride reagent for semi auto analyser\u003c\/li\u003e\n\u003cli\u003eTriglycerides reagent for fully automatic analyser\u003c\/li\u003e\n\u003cli\u003eOpen system biochemistry reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier near me\u003c\/li\u003e\n\u003cli\u003ePathology lab reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eSwemed Triglycerides reagent online India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct Summary\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed Triglycerides Liquid Stable Reagent?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Triglycerides Liquid Stable Reagent\u003c\/strong\u003e is a ready-to-use professional clinical chemistry reagent for quantitative triglyceride estimation using the \u003cstrong\u003eGPO-PAP enzymatic endpoint method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhich pack sizes are available?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e50 ml\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 × 50 ml\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhich method is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses the \u003cstrong\u003eGPO-PAP method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer specifies \u003cstrong\u003e505 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e10 µl sample\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reagent volume?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e1000 µl reagent\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the triglyceride standard concentration?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer insert specifies \u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003eThe stated linearity is \u003cstrong\u003e1000 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the reagent ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. The manufacturer lists both reagent and standard as \u003cstrong\u003eready to use\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs it suitable for semi-automatic analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, for compatible \u003cstrong\u003eopen-system semi-automatic biochemistry analysers\u003c\/strong\u003e after application programming and method validation.\u003c\/p\u003e\n\u003ch3\u003eIs it suitable for fully automatic analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, for compatible \u003cstrong\u003eopen-system fully automatic biochemistry analysers\u003c\/strong\u003e that permit third-party reagent programming, subject to analyser compatibility and laboratory validation.\u003c\/p\u003e\n\u003ch3\u003eWhere can it be purchased?\u003c\/h3\u003e\n\u003cp\u003eThe product can be ordered from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eEntity Information\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eTriglycerides Liquid Stable Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Sizes\u003c\/td\u003e\n\u003ctd\u003e50 ml \/ 2 × 50 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyte\u003c\/td\u003e\n\u003ctd\u003eTriglycerides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eGPO-PAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Type\u003c\/td\u003e\n\u003ctd\u003eEnzymatic Photometric Endpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e505 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e200 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum \/ Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubcategory\u003c\/td\u003e\n\u003ctd\u003eBiochemistry Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eLipid Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyser Compatibility\u003c\/td\u003e\n\u003ctd\u003eOpen-System Fully Automatic \u0026amp; Semi-Automatic Biochemistry Analysers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuyer Type\u003c\/td\u003e\n\u003ctd\u003eLaboratory \/ Hospital \/ Diagnostic Centre \/ B2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"relative w-full mt-4 mb-1\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"contents\"\u003e\n\u003cdiv class=\"relative\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eWhy Buy Swemed Triglycerides Reagent from Microsidd.com?\u003c\/h1\u003e\n\u003cp\u003eLipid-profile reagents require careful procurement because laboratories need to verify the \u003cstrong\u003ecorrect method, pack size, analyser compatibility, standard concentration, storage conditions, expiry and seller source\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMicrosidd India has long-standing experience in the \u003cstrong\u003eIVD and diagnostic-products sector\u003c\/strong\u003e and focuses specifically on laboratory, diagnostic and healthcare products. This gives professional buyers an identifiable specialist procurement source instead of relying only on general marketplace listings.\u003c\/p\u003e\n\u003ch1\u003eMicrosidd.com vs Online Marketplaces vs Offline Suppliers\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLarge Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline \/ Local Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Specialisation\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and laboratory focused\u003c\/td\u003e\n\u003ctd\u003eSeller expertise varies\u003c\/td\u003e\n\u003ctd\u003eDepends on dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Understanding\u003c\/td\u003e\n\u003ctd\u003eBetter suited to reagent-specific enquiries\u003c\/td\u003e\n\u003ctd\u003eOften general marketplace support\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Identity\u003c\/td\u003e\n\u003ctd\u003eDirect purchase from Microsidd India\u003c\/td\u003e\n\u003ctd\u003eMarketplace and actual seller may differ\u003c\/td\u003e\n\u003ctd\u003eUsually locally identifiable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Verification\u003c\/td\u003e\n\u003ctd\u003e50 ml \/ 2 × 50 ml can be confirmed before ordering\u003c\/td\u003e\n\u003ctd\u003eSimilar listings may cause confusion\u003c\/td\u003e\n\u003ctd\u003eDepends on local stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod Verification\u003c\/td\u003e\n\u003ctd\u003eGPO-PAP can be confirmed\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyser Compatibility Support\u003c\/td\u003e\n\u003ctd\u003eBetter suited to open-system analyser queries\u003c\/td\u003e\n\u003ctd\u003eOften limited\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier knowledge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for labs, hospitals and institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eUsually local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSpecialist diagnostic and laboratory catalogue\u003c\/td\u003e\n\u003ctd\u003eBroad but not specialised\u003c\/td\u003e\n\u003ctd\u003eUsually limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect Microsidd support\u003c\/td\u003e\n\u003ctd\u003eMarketplace plus seller layer\u003c\/td\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccountability\u003c\/td\u003e\n\u003ctd\u003eOne identifiable specialist supplier\u003c\/td\u003e\n\u003ctd\u003eSeller may vary by listing\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eSubject to serviceability\u003c\/td\u003e\n\u003ctd\u003eBroad\u003c\/td\u003e\n\u003ctd\u003eUsually regional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eBenefits of Buying from Microsidd.com\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd Advantage\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBenefit to Laboratory Buyers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Product Specialisation\u003c\/td\u003e\n\u003ctd\u003eBetter understanding of professional laboratory procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-Standing IVD Experience\u003c\/td\u003e\n\u003ctd\u003eFamiliarity with clinical chemistry requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Seller Accountability\u003c\/td\u003e\n\u003ctd\u003ePurchase directly from Microsidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification\u003c\/td\u003e\n\u003ctd\u003eMethod and pack variants can be checked before purchase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-System Analyser Support\u003c\/td\u003e\n\u003ctd\u003eEasier verification of programmable settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eUseful for professional and institutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Category Procurement\u003c\/td\u003e\n\u003ctd\u003eLipid, liver, renal and cardiac reagents can be sourced together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBangalore-Based Operations\u003c\/td\u003e\n\u003ctd\u003eConvenient for Bengaluru and Karnataka laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eDelivery to serviceable locations across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Customer Support\u003c\/td\u003e\n\u003ctd\u003eProduct and order-related queries handled directly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed Triglycerides Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is used for quantitative determination of \u003cstrong\u003etriglycerides in serum\/plasma\u003c\/strong\u003e by the GPO-PAP method.\u003c\/p\u003e\n\u003ch3\u003eWhat pack sizes are available?\u003c\/h3\u003e\n\u003cp\u003eThe product is available in \u003cstrong\u003e50 ml and 2 × 50 ml variants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method does the reagent use?\u003c\/h3\u003e\n\u003cp\u003eIt uses the \u003cstrong\u003eGPO-PAP enzymatic method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay is read at \u003cstrong\u003e505 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the standard concentration?\u003c\/h3\u003e\n\u003cp\u003eThe standard concentration is \u003cstrong\u003e200 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e10 µl sample\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reagent volume?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e1000 µl reagent\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the incubation time?\u003c\/h3\u003e\n\u003cp\u003eSwemed specifies \u003cstrong\u003e15 minutes at room temperature or 10 minutes at 37°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003eThe assay is linear up to \u003cstrong\u003e1000 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the reagent ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. Swemed identifies both the reagent and standard as \u003cstrong\u003eready to use\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan it be used on semi-automatic biochemistry analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible \u003cstrong\u003eopen-system semi-automatic analysers\u003c\/strong\u003e after programming and method validation.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on fully automatic biochemistry analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible \u003cstrong\u003eopen-system fully automatic analysers\u003c\/strong\u003e that allow third-party reagent programming.\u003c\/p\u003e\n\u003ch3\u003eIs this product for home testing?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Swemed Triglycerides Reagent in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eThe product can be ordered through \u003cstrong\u003eMicrosidd India at microsidd.com\u003c\/strong\u003e, subject to stock availability.\u003c\/p\u003e\n\u003ch1\u003eMedical and Laboratory Disclaimer\u003c\/h1\u003e\n\u003cp\u003eThe information on this product page is provided for \u003cstrong\u003egeneral product identification, procurement and laboratory educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eTriglyceride results should not be interpreted independently to diagnose or exclude cardiovascular disease, diabetes, metabolic disease or any other condition. Clinical interpretation should consider fasting status, total cholesterol, HDL, LDL, patient history and other relevant investigations.\u003c\/p\u003e\n\u003cp\u003eThe information provided by Microsidd India does not replace the current Swemed Diagnostics package insert, analyser instructions, laboratory SOPs, calibration requirements, internal quality-control procedures or professional medical judgement.\u003c\/p\u003e\n\u003cp\u003eFor open-system fully automatic and semi-automatic analysers, \u003cstrong\u003ecompatibility and application parameters must be programmed and validated by the laboratory before routine clinical use\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhere older and newer manufacturer documents differ in specimen handling or pack configurations, the \u003cstrong\u003ecurrent label and package insert supplied with the actual reagent lot should be treated as the definitive specification\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1\u003eNo Return \/ No Exchange Policy\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Swemed Diagnostics","offers":[{"title":"50ml","offer_id":53147368784192,"sku":"TGL 50ml","price":1800.0,"currency_code":"INR","in_stock":true},{"title":"100ml","offer_id":53147368816960,"sku":"TGL 100ml","price":3499.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/Swemed_Triglycerides_Reagent_50ml_2x50ml_GPO-PAP_Microsidd.png?v=1789261307","url":"https:\/\/microsidd.com\/products\/triglycerides-liquid-stable-reagent","provider":"Microsidd India","version":"1.0","type":"link"}