{"product_id":"swemed-ldh-reagent","title":"LDH Reagent Kit 25 ml | Optimized DGKC Method","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed LDH Reagent Kit 25 ml\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit 25 ml\u003c\/strong\u003e is a professional clinical biochemistry reagent intended for the \u003cstrong\u003equantitative determination of Lactate Dehydrogenase (LDH) activity\u003c\/strong\u003e in suitable laboratory specimens.\u003c\/p\u003e\n\u003cp\u003eSwemed identifies its LDH assay as an \u003cstrong\u003eOptimized DGKC method\u003c\/strong\u003e using the \u003cstrong\u003epyruvate-to-lactate reaction\u003c\/strong\u003e, with a kinetic measurement at \u003cstrong\u003e340 nm\u003c\/strong\u003e. The reagent system is liquid stable, ready to use, and designed for routine professional clinical chemistry laboratories. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis 25 ml pack is suitable for pathology laboratories, diagnostic centres, hospitals and clinical chemistry facilities using compatible \u003cstrong\u003eopen-system semi-automatic and fully automatic biochemistry analysers\u003c\/strong\u003e, subject to application programming and laboratory validation.\u003c\/p\u003e\n\u003ch1\u003eProduct at a Glance\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eLDH Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 ml\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eLactate Dehydrogenase \/ LDH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOptimized DGKC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKinetic UV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction\u003c\/td\u003e\n\u003ctd\u003ePyruvate → Lactate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e340 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eU\/L or IU\/L\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDecreasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e180 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelta Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8199\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking\u003c\/td\u003e\n\u003ctd\u003eWater Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Insert Linearity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 1000 U\/L\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eProfessional In Vitro Diagnostic Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSwemed's LDH insert specifies kinetic mode, 340 nm, 37°C, a factor of 8199, 1000 µl reagent, 25 µl sample, 60-second delay, 180-second reaction time and linearity to 1000 U\/L. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics LDH Reagent Kit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003ePack size: \u003cstrong\u003e25 ml\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptimized DGKC methodology\u003c\/li\u003e\n\u003cli\u003eKinetic UV assay\u003c\/li\u003e\n\u003cli\u003eMeasures LDH activity through pyruvate-to-lactate reaction\u003c\/li\u003e\n\u003cli\u003eMeasurement wavelength: \u003cstrong\u003e340 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReaction direction: \u003cstrong\u003eDecreasing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample volume: \u003cstrong\u003e25 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReagent volume: \u003cstrong\u003e1000 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFactor: \u003cstrong\u003e8199\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer insert linearity: \u003cstrong\u003eup to 1000 U\/L\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLiquid-stable reagent system\u003c\/li\u003e\n\u003cli\u003eSuitable for professional clinical chemistry laboratories\u003c\/li\u003e\n\u003cli\u003eCompatible with suitable open-system semi-auto and fully automatic analysers\u003c\/li\u003e\n\u003cli\u003eFor professional in-vitro diagnostic use only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSwemed's current catalogue additionally describes the LDH reagent as having \u003cstrong\u003ehigh working-reagent stability up to 30 days\u003c\/strong\u003e, and lists a convenient \u003cstrong\u003e25 ml pack size\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eWhat is LDH?\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eLactate Dehydrogenase (LDH)\u003c\/strong\u003e is an intracellular enzyme involved in the reversible conversion between lactate and pyruvate.\u003c\/p\u003e\n\u003cp\u003eLDH is widely distributed in tissues including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeart\u003c\/li\u003e\n\u003cli\u003eLiver\u003c\/li\u003e\n\u003cli\u003eSkeletal muscle\u003c\/li\u003e\n\u003cli\u003eKidney\u003c\/li\u003e\n\u003cli\u003eBlood cells\u003c\/li\u003e\n\u003cli\u003eOther metabolically active tissues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause LDH occurs in many tissues, elevated LDH activity is \u003cstrong\u003enot disease-specific\u003c\/strong\u003e and should always be interpreted with other laboratory findings and clinical information.\u003c\/p\u003e\n\u003ch1\u003eTest Principle\u003c\/h1\u003e\n\u003cp\u003eThe Swemed LDH method is based on the conversion of \u003cstrong\u003epyruvate to lactate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDuring the reaction, \u003cstrong\u003eNADH is oxidised to NAD+\u003c\/strong\u003e. The decrease in NADH absorbance at \u003cstrong\u003e340 nm\u003c\/strong\u003e is measured kinetically.\u003c\/p\u003e\n\u003cp\u003eThe rate of decrease in absorbance is proportional to the LDH activity present in the sample.\u003c\/p\u003e\n\u003cp\u003eSwemed's catalogue specifically describes its LDH assay as an \u003cstrong\u003eOptimized DGKC method with pyruvate-to-lactate test reaction\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSwemed Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest\u003c\/td\u003e\n\u003ctd\u003eLDH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eOptimized DGKC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eKinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e340 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIU\/L\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8199\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Slope\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDecreasing\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e180 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelta Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking\u003c\/td\u003e\n\u003ctd\u003eWater Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 U\/L\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003eAssay Procedure Summary\u003c\/h1\u003e\n\u003cp\u003eSwemed's LDH insert provides the following macro application:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eVolume\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent R1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e800 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent R2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e200 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eMix well and read the initial absorbance after the specified delay, then continue absorbance readings at one-minute intervals.\u003c\/p\u003e\n\u003cp\u003eThe average absorbance change per minute is used to calculate LDH activity. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eCalculation\u003c\/h1\u003e\n\u003cp\u003eFor the Swemed application:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLDH activity = ΔA\/min × Factor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer factor:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8199\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe exact analyser application should be confirmed using the current Swemed insert supplied with the reagent lot. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eMeasuring Range and Linearity\u003c\/h1\u003e\n\u003cp\u003eSwemed's LDH insert states that the assay is linear up to:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1000 U\/L\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor specimens above the validated range, the manufacturer instructs dilution \u003cstrong\u003e1 + 5 with physiological saline\u003c\/strong\u003e, repeating the test and multiplying the result by \u003cstrong\u003e6\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSwemed's newer product catalogue describes LDH as having high linearity up to \u003cstrong\u003e1200 IU\/L\u003c\/strong\u003e. Because manufacturer documents differ, laboratories should follow the \u003cstrong\u003ecurrent lot-specific IFU supplied with the product\u003c\/strong\u003e as the definitive specification. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eReference Range\u003c\/h1\u003e\n\u003cp\u003eSwemed's LDH insert provides a serum reference range of:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e230–460 U\/L\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manufacturer also recommends that each laboratory establish or verify its own reference interval according to its patient population, analyser and analytical system. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eCompatible with Open-System Biochemistry Analysers\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit\u003c\/strong\u003e can be used on compatible programmable open-system chemistry analysers that support kinetic UV measurement at \u003cstrong\u003e340 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSuitable categories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOpen-system semi-automatic biochemistry analysers\u003c\/li\u003e\n\u003cli\u003eOpen-system fully automatic biochemistry analysers\u003c\/li\u003e\n\u003cli\u003eProgrammable clinical chemistry platforms\u003c\/li\u003e\n\u003cli\u003eUV-capable analysers supporting kinetic assays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical application requirements include:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSetting\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLDH Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eKinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e340 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e180 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003eDecreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8199\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe laboratory must validate the method on its own analyser before routine patient reporting.\u003c\/p\u003e\n\u003ch1\u003eWho Can Buy This Product?\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine enzyme testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eLDH estimation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCardiology Laboratories\u003c\/td\u003e\n\u003ctd\u003eEnzyme profile testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHepatology Laboratories\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOncology Laboratories\u003c\/td\u003e\n\u003ctd\u003eGeneral biochemical monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Labs\u003c\/td\u003e\n\u003ctd\u003eKinetic UV enzyme assays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eTeaching and diagnostic use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eInstitutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional reagent supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eUseful Tips Before Ordering\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that you require \u003cstrong\u003eLDH – Optimized DGKC Method\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify pack size: \u003cstrong\u003e25 ml\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm analyser support for \u003cstrong\u003e340 nm kinetic UV measurement\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify that your analyser allows open-system reagent programming.\u003c\/li\u003e\n\u003cli\u003eConfirm sample volume: \u003cstrong\u003e25 µl\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm reagent volume: \u003cstrong\u003e1000 µl\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify the factor and timing parameters before use.\u003c\/li\u003e\n\u003cli\u003eConfirm current linearity from the supplied package insert.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate internal quality control.\u003c\/li\u003e\n\u003cli\u003eCheck expiry and storage requirements before routine use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eBuy Swemed LDH Reagent in Bangalore\u003c\/h1\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003eLDH reagents, cardiac enzyme reagents and clinical biochemistry products from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit 25 ml\u003c\/strong\u003e is suitable for pathology laboratories, diagnostic centres, hospital laboratories and clinical chemistry facilities using compatible open-system analysers.\u003c\/p\u003e\n\u003cp\u003eIt can be ordered through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e, subject to stock availability and serviceability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExplore other Swemed enzyme and clinical chemistry reagents including CK-MB, CK-NAC, SGOT and SGPT.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/swemed-diagnostics\" target=\"_blank\" title=\"Buy Swemed diagnostics laboratory reagents at microsidd.com\" rel=\"noopener\"\u003e\u003cstrong\u003eSwemed Diagnostics Collection\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/bio-chemistry-reagents\" target=\"_blank\" title=\"Buy Laboratory Biochemistry Reagents from microsidd India\" rel=\"noopener\"\u003e\u003cstrong\u003eBiochemistry Reagents Collection\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/microsidd.com\/products\/ck-mb-reagent-kit-25-ml\" target=\"_blank\" title=\"Buy CK MB Laborratory reagents on microsidd.com\" rel=\"noopener\"\u003e\u003cstrong\u003eSwemed CK-MB Reagent\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/microsidd.com\/products\/swemed-ck-nac-reagent-kit-25-ml\" target=\"_blank\" title=\"Buy CK NAC laboratory reagent online microsidd.com\" rel=\"noopener\"\u003e\u003cstrong\u003eSwemed CK-NAC Reagent\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/microsidd.com\/products\/sgot-ast-liquid-stable-reagent-kit\" target=\"_blank\" title=\"Buy Online SGOT reagent on microsidd.com\" rel=\"noopener\"\u003e\u003cstrong\u003eSwemed SGOT Reagent\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/microsidd.com\/products\/sgpt-alt-liquid-stable-reagent-kit\" target=\"_blank\" title=\"Buy SGPT reagent online on microsidd.com\" rel=\"noopener\"\u003e\u003cstrong\u003eSwemed SGPT Reagent\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003eOther related enzyme-reagent products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eSearch Relevance\u003c\/h1\u003e\n\u003cp\u003eRelevant buyer searches include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLDH reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eSwemed LDH reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eLDH reagent 25 ml\u003c\/li\u003e\n\u003cli\u003eLactate dehydrogenase reagent India\u003c\/li\u003e\n\u003cli\u003eDGKC LDH reagent\u003c\/li\u003e\n\u003cli\u003eLDH reagent for semi auto analyser\u003c\/li\u003e\n\u003cli\u003eLDH reagent for fully automatic analyser\u003c\/li\u003e\n\u003cli\u003eCardiac enzyme reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier Bengaluru\u003c\/li\u003e\n\u003cli\u003eBiochemistry reagent supplier near me\u003c\/li\u003e\n\u003cli\u003eSwemed Diagnostics LDH reagent India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eEntity Information\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eLDH Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e25 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyte\u003c\/td\u003e\n\u003ctd\u003eLactate Dehydrogenase \/ LDH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eOptimized DGKC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Type\u003c\/td\u003e\n\u003ctd\u003eKinetic UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e8199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eManufacturer insert: up to 1000 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eEnzyme \/ Clinical Chemistry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubcategory\u003c\/td\u003e\n\u003ctd\u003eBiochemistry Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyser Compatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible Open-System Fully Automatic \u0026amp; Semi-Automatic Analysers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eProduct Summary\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed LDH Reagent Kit?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit 25 ml\u003c\/strong\u003e is a professional clinical chemistry reagent used for quantitative measurement of Lactate Dehydrogenase activity.\u003c\/p\u003e\n\u003ch3\u003eWhat method does it use?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized DGKC Method.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat assay type is used?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003ekinetic UV assay\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e340 nm.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e25 µl.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reagent volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1000 µl.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reaction direction?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDecreasing.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the factor?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e8199.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay linearity?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer insert states \u003cstrong\u003e1000 U\/L\u003c\/strong\u003e, while the newer catalogue describes high linearity up to \u003cstrong\u003e1200 IU\/L\u003c\/strong\u003e. Follow the current lot-specific IFU for final application parameters. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan it be used on semi-automatic analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible open-system semi-automatic biochemistry analysers after method programming and validation.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on fully automatic analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible open-system fully automatic chemistry analysers supporting the required kinetic UV application.\u003c\/p\u003e\n\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eWhy Buy Swemed LDH Reagent from Microsidd.com?\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eLaboratory reagents should be purchased only after confirming the \u003cstrong\u003ecorrect analyte, methodology, pack size, wavelength, analyser compatibility and assay parameters\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMicrosidd India focuses on professional diagnostic, laboratory and IVD products and provides Swemed reagents through dedicated Swemed and Biochemistry collections, making related reagent procurement easier for laboratories.\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eGeneral Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Specialisation\u003c\/td\u003e\n\u003ctd\u003eLaboratory \/ IVD focused\u003c\/td\u003e\n\u003ctd\u003eSeller expertise varies\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod Verification\u003c\/td\u003e\n\u003ctd\u003eOptimized DGKC clearly identified\u003c\/td\u003e\n\u003ctd\u003eListing dependent\u003c\/td\u003e\n\u003ctd\u003eDepends on dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Verification\u003c\/td\u003e\n\u003ctd\u003e25 ml clearly listed\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003ctd\u003eStock dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-System Guidance\u003c\/td\u003e\n\u003ctd\u003eSuitable for analyser-specific queries\u003c\/td\u003e\n\u003ctd\u003eOften limited\u003c\/td\u003e\n\u003ctd\u003eDepends on expertise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelated Swemed Reagents\u003c\/td\u003e\n\u003ctd\u003eEasy cross-navigation\u003c\/td\u003e\n\u003ctd\u003eOften scattered\u003c\/td\u003e\n\u003ctd\u003eStock dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for labs and institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eUsually suitable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Identity\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003ctd\u003eMarketplace seller may vary\u003c\/td\u003e\n\u003ctd\u003eUsually identifiable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed LDH Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is used for quantitative determination of \u003cstrong\u003eLactate Dehydrogenase enzyme activity\u003c\/strong\u003e in professional clinical chemistry laboratories.\u003c\/p\u003e\n\u003ch3\u003eWhat method is used?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized DGKC Method.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the pack size?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e25 ml.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e340 nm.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay mode?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eKinetic.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e25 µl.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reagent volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1000 µl.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the factor?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e8199.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reaction direction?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDecreasing.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the manufacturer-stated linearity?\u003c\/h3\u003e\n\u003cp\u003eThe technical insert states \u003cstrong\u003e1000 U\/L\u003c\/strong\u003e, while the current catalogue describes up to \u003cstrong\u003e1200 IU\/L\u003c\/strong\u003e. Use the current lot-specific manufacturer IFU as the definitive value. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan it be used on semi-auto analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible \u003cstrong\u003eopen-system semi-automatic biochemistry analysers\u003c\/strong\u003e after programming and validation.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on fully automatic analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible open-system fully automatic analysers supporting the required kinetic UV method.\u003c\/p\u003e\n\u003ch3\u003eIs LDH specific to one disease?\u003c\/h3\u003e\n\u003cp\u003eNo. LDH is present in multiple tissues, so an abnormal value should be interpreted with other clinical and laboratory findings.\u003c\/p\u003e\n\u003ch3\u003eIs this product for home use?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in-vitro diagnostic laboratory use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1\u003eMedical and Laboratory Disclaimer\u003c\/h1\u003e\n\u003cp\u003eThe information on this page is provided for \u003cstrong\u003eproduct identification, laboratory procurement and professional educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eLDH is a non-specific enzyme marker and should not be interpreted independently to diagnose or exclude cardiac, hepatic, haematological, muscular, oncological or other disorders.\u003c\/p\u003e\n\u003cp\u003eFor open-system fully automatic and semi-automatic analysers, \u003cstrong\u003einstrument compatibility, reagent application settings, quality control and analytical performance must be independently verified and validated by the laboratory before routine patient reporting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBecause manufacturer documentation currently shows a difference between the technical insert and newer catalogue for maximum linearity, the \u003cstrong\u003ecurrent package insert supplied with the actual reagent lot should be treated as the definitive technical specification\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1\u003eNo Return \/ No Exchange Policy\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Swemed Diagnostics","offers":[{"title":"Default Title","offer_id":53152242925888,"sku":"LDH 25ml","price":850.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/SwemedLDHReagent25mlOptimizedDGKCMethodMicrosidd.png?v=1789403409","url":"https:\/\/microsidd.com\/products\/swemed-ldh-reagent","provider":"Microsidd India","version":"1.0","type":"link"}