{"product_id":"sgot-ast-liquid-stable-reagent-kit","title":"SGOT (AST) Liquid Stable Reagent Kit 50 ml – Modified IFCC Kinetic Method","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed SGOT (AST) Liquid Stable Reagent Kit 50 ml\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed SGOT (AST) Liquid Stable Reagent Kit 50 ml\u003c\/strong\u003e is a professional clinical biochemistry reagent intended for quantitative determination of \u003cstrong\u003eAspartate Aminotransferase (AST), also known as SGOT\u003c\/strong\u003e, using the \u003cstrong\u003eModified IFCC kinetic method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwemed’s official SGOT literature describes the assay as a kinetic UV method in which AST catalyses transfer of an amino group from L-aspartate to α-ketoglutarate, producing oxaloacetate and L-glutamate. The oxaloacetate then reacts with NADH in the presence of malate dehydrogenase, and the resulting \u003cstrong\u003edecrease in absorbance at 340 nm\u003c\/strong\u003e is proportional to SGOT\/AST activity in the sample. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSGOT\/AST is an important enzyme found in tissues including the \u003cstrong\u003eliver, heart, skeletal muscle and kidneys\u003c\/strong\u003e. Its measurement is commonly included in \u003cstrong\u003eliver function testing and broader clinical chemistry enzyme panels\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e in pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eSGOT \/ AST Liquid Stable Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e50 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eClinical Biochemistry Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eSGOT \/ AST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Name\u003c\/td\u003e\n\u003ctd\u003eAspartate Aminotransferase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eModified IFCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Mode\u003c\/td\u003e\n\u003ctd\u003eKinetic UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003eDecreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwemed Website Listing\u003c\/td\u003e\n\u003ctd\u003eSerum \/ Plasma (EDTA \/ Heparin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent System\u003c\/td\u003e\n\u003ctd\u003eR1 + R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Reagent Ratio\u003c\/td\u003e\n\u003ctd\u003e4 parts R1 + 1 part R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e100 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Interval\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalculation Factor\u003c\/td\u003e\n\u003ctd\u003e1746\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eUp to 300 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eProfessional In Vitro Diagnostic Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru, Karnataka, India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe technical assay parameters above are taken from Swemed’s official SGOT product insert. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics SGOT \/ AST Reagent Kit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003ePack size: \u003cstrong\u003e50 ml\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModified IFCC kinetic method\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUV measurement at \u003cstrong\u003e340 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLiquid stable two-reagent system\u003c\/li\u003e\n\u003cli\u003eSuitable for routine AST \/ SGOT activity measurement\u003c\/li\u003e\n\u003cli\u003eWorking reagent prepared using \u003cstrong\u003e4 parts R1 + 1 part R2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWorking reagent stability: \u003cstrong\u003e7 days at 15–25°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWorking reagent stability: \u003cstrong\u003e4 weeks at 2–8°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLinearity up to \u003cstrong\u003e300 U\/L\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for professional liver and enzyme-profile testing\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003ein vitro diagnostic use only\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Benefits\u003c\/h1\u003e\n\u003ch2\u003eModified IFCC Method\u003c\/h2\u003e\n\u003cp\u003eThe Swemed SGOT assay uses a \u003cstrong\u003eModified IFCC kinetic method\u003c\/strong\u003e, providing a standardised enzymatic approach for routine AST activity measurement.\u003c\/p\u003e\n\u003ch2\u003eLiquid Stable Reagent System\u003c\/h2\u003e\n\u003cp\u003eThe product uses a two-reagent system designed for routine laboratory use and working-reagent preparation.\u003c\/p\u003e\n\u003ch2\u003eUseful Working Reagent Stability\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer states that prepared working reagent remains stable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e7 days at 15–25°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 weeks at 2–8°C\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSuitable for Routine Liver Function Testing\u003c\/h2\u003e\n\u003cp\u003eSGOT \/ AST is commonly measured together with SGPT \/ ALT, bilirubin, alkaline phosphatase, albumin and total protein as part of \u003cstrong\u003eliver function assessment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eProfessional Laboratory Application\u003c\/h2\u003e\n\u003cp\u003eThe method is suitable for trained laboratory personnel using compatible semi-automated or automated chemistry systems after analyser validation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eIntended Use\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed SGOT \/ AST Reagent Kit\u003c\/strong\u003e is intended for quantitative determination of \u003cstrong\u003eAspartate Aminotransferase activity\u003c\/strong\u003e in professional clinical chemistry laboratories.\u003c\/p\u003e\n\u003cp\u003eThe official Swemed insert specifies \u003cstrong\u003eserum\u003c\/strong\u003e as the specimen and recommends fresh, clear, non-haemolysed serum. Swemed’s biochemistry listing also associates SGOT with serum\/plasma including EDTA and heparin plasma, so the actual specimen type should follow the current kit insert supplied with the product and the laboratory’s validated method. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTest Principle\u003c\/h1\u003e\n\u003cp\u003eSGOT \/ AST catalyses the following reaction:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eL-Aspartate + α-Ketoglutarate → L-Glutamate + Oxaloacetate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe oxaloacetate formed then reacts with NADH in the presence of \u003cstrong\u003emalate dehydrogenase (MDH)\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOxaloacetate + NADH + H+ → L-Malate + NAD+\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe rate at which NADH is oxidised to NAD+ is measured as a \u003cstrong\u003edecrease in absorbance at 340 nm\u003c\/strong\u003e, and this rate is proportional to AST activity in the sample. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eReagent Composition\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eTris Buffer pH 7.8 – 6 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eL-Aspartate – 30.5 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eLDH – 4 kU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eMDH – 700 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 2\u003c\/td\u003e\n\u003ctd\u003eα-Ketoglutarate – 3.4 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 2\u003c\/td\u003e\n\u003ctd\u003eNADH – 1.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe manufacturer also states that the reagents contain \u003cstrong\u003esodium azide 0.95 g\/L as preservative\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eReagent Preparation\u003c\/h1\u003e\n\u003cp\u003ePrepare the working reagent by mixing:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4 parts Reagent R1 + 1 part Reagent R2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlternatively, the Swemed insert states that \u003cstrong\u003e0.8 ml R1 + 0.2 ml R2\u003c\/strong\u003e may be used directly instead of 1 ml of pre-mixed working reagent during the assay. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe working reagent should have an absorbance \u003cstrong\u003eabove 1.0 against distilled water at 340 nm\u003c\/strong\u003e. Reagent falling below this level should not be used. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWorking Reagent Stability\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eStorage Condition\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e15–25°C\u003c\/td\u003e\n\u003ctd\u003e7 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003ctd\u003e4 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTest Parameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSGOT \/ AST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eModified IFCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eKinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003eIU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Slope\u003c\/td\u003e\n\u003ctd\u003eDecreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e100 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Interval\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking\u003c\/td\u003e\n\u003ctd\u003eWater Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e1746\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e300 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese values are listed in Swemed’s quick-reference section. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManual Assay Procedure\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMacro Method\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSemi-Micro Method\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent R1 + R2\u003c\/td\u003e\n\u003ctd\u003e800 µl + 200 µl\u003c\/td\u003e\n\u003ctd\u003e400 µl + 100 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e100 µl\u003c\/td\u003e\n\u003ctd\u003e50 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eMix well and read the initial absorbance after \u003cstrong\u003e1 minute\u003c\/strong\u003e. Continue readings at approximately \u003cstrong\u003e1-minute intervals for 3 minutes\u003c\/strong\u003e, then calculate the mean absorbance change per minute. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCalculation\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSGOT \/ AST (U\/L) = ΔA\/min × 1746\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMeasuring Range and Linearity\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer states a linearity of \u003cstrong\u003e300 U\/L\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhen the reaction rate exceeds the stated measuring range, Swemed describes dilution of the sample \u003cstrong\u003e1 + 9 with 0.9% NaCl\u003c\/strong\u003e, followed by multiplication of the obtained result by \u003cstrong\u003e10\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Requirements\u003c\/h1\u003e\n\u003cp\u003eThe official product insert recommends:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eFresh serum\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eClear sample\u003c\/li\u003e\n\u003cli\u003eNon-haemolysed specimen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is particularly important because \u003cstrong\u003ered blood cells contain AST\u003c\/strong\u003e, and haemolysis may cause falsely elevated results. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Stability\u003c\/h1\u003e\n\u003cp\u003eAccording to the Swemed product literature, SGOT \/ AST in serum is reported stable for:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eStorage Condition\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e15–30°C\u003c\/td\u003e\n\u003ctd\u003e4 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003ctd\u003e10 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e−20°C\u003c\/td\u003e\n\u003ctd\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eInterference Information\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer reports that under the evaluated conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBilirubin up to \u003cstrong\u003e18 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHaemoglobin up to \u003cstrong\u003e300 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ehad negligible effect on the assay. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, haemolysed samples should still be avoided because red cells contain AST and can produce misleadingly elevated results.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManufacturer Reference Range\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eGroup\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Reference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWomen\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 31 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMen\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 32 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSwemed also advises that each laboratory establish or validate reference intervals appropriate for its own patient population. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy SGOT \/ AST Testing Is Important\u003c\/h1\u003e\n\u003cp\u003eAST is present in several tissues, particularly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLiver\u003c\/li\u003e\n\u003cli\u003eCardiac muscle\u003c\/li\u003e\n\u003cli\u003eSkeletal muscle\u003c\/li\u003e\n\u003cli\u003eKidneys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAST activity may rise when cells in these tissues are injured. SGOT \/ AST testing may therefore form part of laboratory investigations related to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLiver injury\u003c\/li\u003e\n\u003cli\u003eHepatitis\u003c\/li\u003e\n\u003cli\u003eCirrhosis\u003c\/li\u003e\n\u003cli\u003eMuscle injury\u003c\/li\u003e\n\u003cli\u003eCardiac-related investigations\u003c\/li\u003e\n\u003cli\u003eAcute pancreatitis\u003c\/li\u003e\n\u003cli\u003eRenal disease\u003c\/li\u003e\n\u003cli\u003eRoutine liver-function profiles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause AST is \u003cstrong\u003enot liver-specific\u003c\/strong\u003e, results should be interpreted together with other parameters such as ALT \/ SGPT, bilirubin, alkaline phosphatase, albumin and clinical findings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSGOT \/ AST in a Liver Function Profile\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTest\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLaboratory Relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGOT \/ AST\u003c\/td\u003e\n\u003ctd\u003eHepatic and extra-hepatic enzyme assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGPT \/ ALT\u003c\/td\u003e\n\u003ctd\u003eMore liver-associated transaminase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBilirubin Total\u003c\/td\u003e\n\u003ctd\u003eBilirubin metabolism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBilirubin Direct\u003c\/td\u003e\n\u003ctd\u003eConjugated bilirubin assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkaline Phosphatase\u003c\/td\u003e\n\u003ctd\u003eHepatobiliary and bone-related enzyme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlbumin\u003c\/td\u003e\n\u003ctd\u003eLiver synthetic function \/ nutritional assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Protein\u003c\/td\u003e\n\u003ctd\u003eProtein status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGGT\u003c\/td\u003e\n\u003ctd\u003eHepatobiliary enzyme where included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eStorage and Handling\u003c\/h1\u003e\n\u003cp\u003eSwemed states that the reagents should be:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStored at \u003cstrong\u003e2–8°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtected from light\u003c\/li\u003e\n\u003cli\u003eProtected from contamination\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNot frozen\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUsed only within the stated shelf life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer also advises against using reagent if the initial absorbance at 340 nm falls below the stated acceptable level or if performance requirements are not met. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSafety and Precautions\u003c\/h1\u003e\n\u003cp\u003eLaboratory personnel should:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWear suitable gloves\u003c\/li\u003e\n\u003cli\u003eUse eye and face protection\u003c\/li\u003e\n\u003cli\u003eAvoid skin and mucous membrane contact\u003c\/li\u003e\n\u003cli\u003eAvoid ingestion\u003c\/li\u003e\n\u003cli\u003eFollow current Good Laboratory Practice\u003c\/li\u003e\n\u003cli\u003eHandle sodium-azide-containing reagent appropriately\u003c\/li\u003e\n\u003cli\u003eDispose of reagents according to institutional procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWho Can Buy This Product?\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine AST \/ SGOT testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eLiver function testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGastroenterology Centres\u003c\/td\u003e\n\u003ctd\u003eLiver enzyme assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHepatology Centres\u003c\/td\u003e\n\u003ctd\u003eLiver function monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Laboratories\u003c\/td\u003e\n\u003ctd\u003eEnzyme testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and teaching laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eInstitutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional supply where permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eUseful Tips Before Ordering\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that \u003cstrong\u003eSGOT \/ AST\u003c\/strong\u003e is the required test.\u003c\/li\u003e\n\u003cli\u003eConfirm the pack size: \u003cstrong\u003e50 ml\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eEnsure analyser support for \u003cstrong\u003e340 nm kinetic measurement\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm the laboratory uses the \u003cstrong\u003eModified IFCC method\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with your analyser.\u003c\/li\u003e\n\u003cli\u003eConfirm suitable sample type.\u003c\/li\u003e\n\u003cli\u003eAvoid haemolysed specimens.\u003c\/li\u003e\n\u003cli\u003eFollow the \u003cstrong\u003e4:1 R1:R2 working reagent ratio\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eStore reagents at \u003cstrong\u003e2–8°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDo not freeze.\u003c\/li\u003e\n\u003cli\u003eFollow current manufacturer and laboratory quality-control procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eBuy Swemed SGOT Reagent in Bangalore\u003c\/h1\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003eliver-function reagents, clinical biochemistry reagents and laboratory products from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed SGOT \/ AST Liquid Stable Reagent Kit 50 ml\u003c\/strong\u003e is suitable for procurement by pathology laboratories, diagnostic centres, hospitals, gastroenterology centres, clinical chemistry laboratories and other professional healthcare buyers.\u003c\/p\u003e\n\u003cp\u003eCustomers can order through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e, subject to stock availability and delivery serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSearch Relevance\u003c\/h1\u003e\n\u003cp\u003eThis product is relevant for buyers searching for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSGOT reagent supplier in Bangalore\u003c\/li\u003e\n\u003cli\u003eAST reagent supplier Bengaluru\u003c\/li\u003e\n\u003cli\u003eSwemed SGOT reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eSGOT reagent 50 ml\u003c\/li\u003e\n\u003cli\u003eAST Modified IFCC reagent India\u003c\/li\u003e\n\u003cli\u003eLiver function reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eSGOT kinetic reagent supplier Karnataka\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier near me\u003c\/li\u003e\n\u003cli\u003ePathology lab reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eSGOT test reagent online India\u003c\/li\u003e\n\u003cli\u003eSwemed Diagnostics reagent supplier India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eAI \/ LLM-Friendly Product Summary\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed SGOT Liquid Stable Reagent Kit 50 ml?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed SGOT \/ AST Liquid Stable Reagent Kit 50 ml\u003c\/strong\u003e is a professional clinical chemistry reagent used for quantitative measurement of Aspartate Aminotransferase activity using a \u003cstrong\u003eModified IFCC kinetic UV method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay is measured at \u003cstrong\u003e340 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe macro method uses \u003cstrong\u003e100 µl sample\u003c\/strong\u003e, while the semi-micro method uses \u003cstrong\u003e50 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the calculation factor?\u003c\/h3\u003e\n\u003cp\u003eThe stated factor is \u003cstrong\u003e1746\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay linearity?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer states a linearity of \u003cstrong\u003e300 U\/L\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow is the working reagent prepared?\u003c\/h3\u003e\n\u003cp\u003eMix \u003cstrong\u003e4 parts R1 with 1 part R2\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow long is the working reagent stable?\u003c\/h3\u003e\n\u003cp\u003eSwemed states \u003cstrong\u003e7 days at 15–25°C\u003c\/strong\u003e and \u003cstrong\u003e4 weeks at 2–8°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhere can Swemed SGOT reagent be purchased?\u003c\/h3\u003e\n\u003cp\u003eIt can be purchased from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to stock availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eGEO and Entity Information\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eSGOT \/ AST Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e50 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyte\u003c\/td\u003e\n\u003ctd\u003eAspartate Aminotransferase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Name\u003c\/td\u003e\n\u003ctd\u003eSGOT \/ AST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eModified IFCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eKinetic UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eLiver Function \/ Clinical Chemistry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuyer Type\u003c\/td\u003e\n\u003ctd\u003eLaboratory \/ Hospital \/ Diagnostic Centre \/ B2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eWhy Buy Swemed SGOT Reagent from Microsidd.com?\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eClinical chemistry reagents should be purchased with careful attention to the \u003cstrong\u003ecorrect analyte, method, reagent configuration, pack size, analyser compatibility, storage requirements, expiry and seller credibility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMicrosidd India has been involved in the \u003cstrong\u003eIVD and diagnostic-product sector since 2000\u003c\/strong\u003e and focuses on laboratory, diagnostic and healthcare supplies. Professional buyers therefore deal with an identifiable diagnostic-products specialist rather than depending only on general marketplace sellers.\u003c\/p\u003e\n\u003ch2\u003eMicrosidd.com vs Online Marketplaces vs Offline Suppliers\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLarge Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline \/ Local Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Specialisation\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and laboratory focused\u003c\/td\u003e\n\u003ctd\u003eSeller expertise varies\u003c\/td\u003e\n\u003ctd\u003eDepends on dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Knowledge\u003c\/td\u003e\n\u003ctd\u003eBetter suited to reagent-specific enquiries\u003c\/td\u003e\n\u003ctd\u003eOften general marketplace support\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Identity\u003c\/td\u003e\n\u003ctd\u003eDirect purchase from Microsidd India\u003c\/td\u003e\n\u003ctd\u003eMarketplace and actual seller may differ\u003c\/td\u003e\n\u003ctd\u003eUsually locally identifiable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod Verification\u003c\/td\u003e\n\u003ctd\u003eSGOT, Modified IFCC and pack can be verified before order\u003c\/td\u003e\n\u003ctd\u003eSimilar listings may cause confusion\u003c\/td\u003e\n\u003ctd\u003eDepends on dealer knowledge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for labs, hospitals and institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eUsually local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSpecialist diagnostic and laboratory catalogue\u003c\/td\u003e\n\u003ctd\u003eBroad but not specialised\u003c\/td\u003e\n\u003ctd\u003eUsually limited by local inventory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect Microsidd assistance\u003c\/td\u003e\n\u003ctd\u003eMarketplace plus seller layer\u003c\/td\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccountability\u003c\/td\u003e\n\u003ctd\u003eOne identifiable specialist supplier\u003c\/td\u003e\n\u003ctd\u003eSeller may vary between listings\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eSubject to serviceability\u003c\/td\u003e\n\u003ctd\u003eBroad\u003c\/td\u003e\n\u003ctd\u003eUsually regional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eBenefits of Buying from Microsidd.com\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd Advantage\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBenefit to Laboratory Buyers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Product Specialisation\u003c\/td\u003e\n\u003ctd\u003eBetter suited to professional laboratory procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIVD Experience Since 2000\u003c\/td\u003e\n\u003ctd\u003eLong-standing diagnostic-sector experience\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Seller Accountability\u003c\/td\u003e\n\u003ctd\u003ePurchase directly from Microsidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eUseful for laboratories and institutional buyers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification Support\u003c\/td\u003e\n\u003ctd\u003eMethod, pack and specifications can be checked before purchase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Category Procurement\u003c\/td\u003e\n\u003ctd\u003eLiver, renal, lipid, cardiac and other reagents can be sourced together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBangalore-Based Operations\u003c\/td\u003e\n\u003ctd\u003eConvenient for Bengaluru and Karnataka laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eDelivery to serviceable locations across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Customer Support\u003c\/td\u003e\n\u003ctd\u003eProduct and order queries handled directly by Microsidd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed SGOT Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is intended for quantitative determination of \u003cstrong\u003eAST \/ SGOT enzyme activity\u003c\/strong\u003e in professional clinical chemistry laboratories.\u003c\/p\u003e\n\u003ch3\u003eWhat is the pack size?\u003c\/h3\u003e\n\u003cp\u003eThe pack size is \u003cstrong\u003e50 ml\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method does the Swemed SGOT Reagent use?\u003c\/h3\u003e\n\u003cp\u003eIt uses a \u003cstrong\u003eModified IFCC kinetic method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e340 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat temperature is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay is performed at \u003cstrong\u003e37°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe macro method uses \u003cstrong\u003e100 µl\u003c\/strong\u003e, and the semi-micro method uses \u003cstrong\u003e50 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay factor?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer factor is \u003cstrong\u003e1746\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer states \u003cstrong\u003e300 U\/L\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow is the working reagent prepared?\u003c\/h3\u003e\n\u003cp\u003eMix \u003cstrong\u003e4 parts R1 with 1 part R2\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow long is the prepared reagent stable?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer states \u003cstrong\u003e7 days at 15–25°C\u003c\/strong\u003e and \u003cstrong\u003e4 weeks at 2–8°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan haemolysed serum be used?\u003c\/h3\u003e\n\u003cp\u003eIt should be avoided because red blood cells contain AST and can produce falsely elevated results. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs this product for home testing?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on any biochemistry analyser?\u003c\/h3\u003e\n\u003cp\u003eThe laboratory should verify \u003cstrong\u003e340 nm capability, kinetic programming, reagent ratio, sample volume and validated application\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Swemed SGOT Reagent in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eIt can be ordered through \u003cstrong\u003eMicrosidd India at microsidd.com\u003c\/strong\u003e, subject to stock availability.\u003c\/p\u003e\n\u003ch3\u003eWhy buy from Microsidd.com?\u003c\/h3\u003e\n\u003cp\u003eMicrosidd India specialises in diagnostic and laboratory products and provides direct seller accountability, GST invoicing for eligible purchases, product-verification support and professional procurement convenience.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMedical and Laboratory Disclaimer\u003c\/h1\u003e\n\u003cp\u003eThe information on this product page is provided for \u003cstrong\u003egeneral product identification, procurement and educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAST \/ SGOT is not specific to a single organ. An elevated result should not be used independently to diagnose liver, cardiac, muscular or renal disease. Clinical interpretation should consider ALT \/ SGPT, bilirubin, alkaline phosphatase, symptoms, history and other relevant investigations.\u003c\/p\u003e\n\u003cp\u003eThe information provided by Microsidd India does not replace the official Swemed Diagnostics package insert, analyser instructions, laboratory standard operating procedures, calibration requirements, quality-control procedures or professional medical judgement.\u003c\/p\u003e\n\u003cp\u003eSpecimen requirements, reagent preparation, analyser settings, calibration, reference intervals, storage, stability and interpretation must always follow current manufacturer instructions and validated laboratory procedures.\u003c\/p\u003e\n\u003ch1\u003eNo Return \/ No Exchange Policy\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Microsidd India","offers":[{"title":"Default Title","offer_id":53143495901504,"sku":"SGOT 50ml","price":950.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/SGOT_AST_ReagentKit50mlModifiedIFCCMethodMicrosidd.png?v=1789141832","url":"https:\/\/microsidd.com\/products\/sgot-ast-liquid-stable-reagent-kit","provider":"Microsidd India","version":"1.0","type":"link"}