{"product_id":"peerless-crp-turbidimetric-reagent-1x50ml","title":"CRP Turbidimetric Reagent 1×50 mL | Turbilatex | Professional IVD | Peerless","description":"\u003ch2\u003ePeerless CRP Turbidimetric Reagent 1×50 mL | Latex Turbidimetry | Professional IVD\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePeerless CRP Turbidimetric Reagent\u003c\/strong\u003e is a professional in-vitro diagnostic reagent for the quantitative determination of \u003cstrong\u003eC-Reactive Protein (CRP)\u003c\/strong\u003e in serum using a \u003cstrong\u003elatex turbidimetric method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis listing is for the \u003cstrong\u003e1 × 50 mL pack\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe supplied method uses latex particles coated with anti-CRP antibodies. When these particles react with CRP present in the specimen, agglutination occurs. The degree of agglutination is proportional to the CRP concentration and is measured turbidimetrically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional laboratory use only.\u003c\/strong\u003e This product should be used by trained laboratory personnel on compatible validated photometric \/ chemistry analyser systems according to the current Peerless IFU and laboratory SOP.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e CRP – Turbidimetric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod:\u003c\/strong\u003e Latex Turbidimetry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \/ Marketed By:\u003c\/strong\u003e Peerless Biotech Pvt. Ltd.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack Size:\u003c\/strong\u003e 1 × 50 mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalyte:\u003c\/strong\u003e C-Reactive Protein \/ CRP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecimen:\u003c\/strong\u003e Serum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReaction:\u003c\/strong\u003e Increasing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMode:\u003c\/strong\u003e Two Point Kinetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength:\u003c\/strong\u003e 540 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Volume:\u003c\/strong\u003e 10 µL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking Reagent Volume:\u003c\/strong\u003e 1.0 mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLag Time:\u003c\/strong\u003e 10 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Time:\u003c\/strong\u003e 120 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Up to 150 mg\/L under the described assay conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit:\u003c\/strong\u003e mg\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Value:\u003c\/strong\u003e Adults up to 5 mg\/L; laboratories should establish their own reference range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage:\u003c\/strong\u003e 2–8°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePrinciple of the CRP Turbidimetric Test\u003c\/h2\u003e\n\u003cp\u003eThe reagent uses \u003cstrong\u003elatex particles coated with anti-CRP antibodies\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhen a serum sample containing C-Reactive Protein is mixed with the latex reagent, antigen-antibody agglutination occurs. The resulting increase in turbidity is proportional to the CRP concentration in the specimen and is measured photometrically.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eReagent Composition\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eR1 – Diluent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTris buffer, 20 mmol\/L, pH 8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eR2 – Latex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLatex particles coated with goat anti-human CRP, pH 7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCAL – Calibrator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eHuman serum; CRP concentration stated on the vial label and traceable to Certified Reference Material BCR 470 (IRMM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe IFU states that R1, R2 and calibrator are ready to use. R2 should be gently shaken \/ swirled before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e the supplied IFU contains an apparent inconsistency between its stated working-reagent mixing ratio and the numerical example. Laboratories should follow the current manufacturer application sheet \/ lot-specific IFU or confirm the preparation directly with Peerless before routine use rather than resolving this discrepancy by assumption.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAssay Procedure – Manufacturer Method\u003c\/h2\u003e\n\u003cp\u003ePrewarm the working reagent and photometer \/ cuvette holder to \u003cstrong\u003e37°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eInstrument Zero\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDistilled water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e540 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSample \/ Calibrator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eWorking Reagent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1.0 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eFirst Reading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eImmediately after sample addition – A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSecond Reading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAfter 2 minutes – A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eCRP Calculation\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer IFU calculates CRP concentration using the change in absorbance of the sample relative to the calibrator:\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e CRP (mg\/L) = [(A2 − A1) Sample ÷ (A2 − A1) Calibrator] × Calibrator Concentration \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe calibrator concentration should be taken from the value stated on the supplied calibrator vial.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSystem Parameters\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTwo Point Kinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eReaction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e540 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBlank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDistilled Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eReagent Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1.0 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eLag Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMeasuring Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eLinearity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUp to 150 mg\/L under the described assay conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eReporting Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003emg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecimen Requirements\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecimen: Fresh serum.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccording to the IFU:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSerum is stable for \u003cstrong\u003e7 days at 2–8°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSerum may be stored for up to \u003cstrong\u003e3 months at −20°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eSamples containing fibrin should be centrifuged before testing.\u003c\/li\u003e\n\u003cli\u003eHemolysed or contaminated samples are not suitable for testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eStorage \u0026amp; Stability\u003c\/h2\u003e\n\u003cp\u003eStore the reagents tightly closed at \u003cstrong\u003e2–8°C\u003c\/strong\u003e and prevent contamination during use.\u003c\/p\u003e\n\u003cp\u003eAccording to the IFU:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnopened \/ properly stored reagents remain stable until the expiry date printed on the label.\u003c\/li\u003e\n\u003cli\u003eDo not use reagents after their expiry date.\u003c\/li\u003e\n\u003cli\u003eThe prepared working reagent is stated to be stable for \u003cstrong\u003e20 days at 2–8°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eGently shake the reagent before use.\u003c\/li\u003e\n\u003cli\u003eVisible particles or abnormal turbidity may indicate reagent deterioration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eAnalytical Performance\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUp to 150 mg\/L under the described assay conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eAbove Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIFU instructs samples above the range to be diluted 1\/5 in 9 g\/L NaCl and retested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eDetection Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eValues below 1 mg\/L are stated to give non-reproducible results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eAnalytical Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2.9 mA \/ mg CRP\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProzone Effect\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUp to 250 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe IFU also reports that results did not show systematic differences when compared with commercial reagents of similar characteristics; detailed comparison data are available from the manufacturer on request.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eInterference Information\u003c\/h2\u003e\n\u003cp\u003eUnder the conditions stated in the Peerless IFU, the following concentrations are reported not to interfere:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLipemia:\u003c\/strong\u003e 10 g\/L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRheumatoid Factors:\u003c\/strong\u003e 800 IU\/mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBilirubin:\u003c\/strong\u003e 40 mg\/dL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHemoglobin:\u003c\/strong\u003e 12 g\/L\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOther substances may interfere. Laboratories should follow the complete current IFU and their internal interference-investigation policy when unexpected results occur.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eQuality Control\u003c\/h2\u003e\n\u003cp\u003eControl sera should be used to monitor the performance of both manual and automated assay procedures.\u003c\/p\u003e\n\u003cp\u003eThe Peerless IFU recommends:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlasma Protein Control N-I – Ref. 3915010\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePlasma Protein Control N-II – Ref. 3915015\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach laboratory should establish its own quality-control scheme, acceptable limits and corrective actions when controls fall outside established tolerances.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eReference Values\u003c\/h2\u003e\n\u003cp\u003eThe IFU lists the following adult reference value:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdults: Up to 5 mg\/L\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach laboratory should establish or verify its own reference interval appropriate to its population, analytical system and laboratory practice.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAnalyser Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe Peerless IFU states that this method may be used with different instruments; however, \u003cstrong\u003eevery analyser application should be validated\u003c\/strong\u003e to demonstrate that the required analytical performance characteristics are achieved.\u003c\/p\u003e\n\u003cp\u003eThe IFU further notes that the linearity limit can depend on the sample-to-reagent ratio and analyser being used.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, laboratories should therefore verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAnalyser model\u003c\/li\u003e\n\u003cli\u003eOpen-system capability\u003c\/li\u003e\n\u003cli\u003e540 nm photometric capability\u003c\/li\u003e\n\u003cli\u003e37°C thermostatic capability\u003c\/li\u003e\n\u003cli\u003eTwo-point kinetic programming\u003c\/li\u003e\n\u003cli\u003eSample and reagent volumes\u003c\/li\u003e\n\u003cli\u003eCalibration procedure\u003c\/li\u003e\n\u003cli\u003eQuality-control requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eClinical Significance of CRP\u003c\/h2\u003e\n\u003cp\u003eC-Reactive Protein is an acute-phase protein that may increase following tissue injury, infection, inflammation and other pathological processes.\u003c\/p\u003e\n\u003cp\u003eCRP is a non-specific laboratory marker. A result should not be used alone to establish a diagnosis or determine the cause of inflammation.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifically states that clinical diagnosis should not be made from a single test result but should be based on appropriate clinical and laboratory information.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eManufacturer \u0026amp; Marketing Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eManufactured by:\u003c\/strong\u003e Asritha Diatech India Pvt. Ltd.\u003cbr\u003e\u003cstrong\u003eMarketed by:\u003c\/strong\u003e Peerless Biotech Pvt. Ltd.\u003c\/p\u003e\n\u003cp\u003eThis distinction is useful for laboratories verifying the exact reagent source, current IFU and technical support documentation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Laboratory Products at Microsidd\u003c\/h2\u003e\n\u003cp\u003eBrowse professional laboratory reagents and equipment:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/bio-chemistry-reagents\"\u003e\u003cstrong\u003eBio Chemistry Reagents\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/laboratory-needs\"\u003e\u003cstrong\u003eLaboratory Needs \u0026amp; Equipment\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/microsidd.com\/pages\/microsidd-india-bangalore\"\u003e\u003cstrong\u003eMicrosidd India – Laboratory \u0026amp; Medical Supplies Bangalore\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy Peerless CRP Reagent from Microsidd India?\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBuying Consideration\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMicrosidd India\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eGeneral Marketplace \/ Local Market\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eExact Method Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCRP Latex Turbidimetry clearly identified\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMethod details may be omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 × 50 mL clearly stated\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMay vary between listings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eTechnical Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIFU-based parameters presented for pre-purchase verification\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOften limited to basic product title and price\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eAnalyser Compatibility Warning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBuyers advised to verify analyser and method settings before ordering\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProfessional Laboratory Focus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDiagnostic and laboratory-product focused supplier\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMay be a general marketplace seller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eGST Invoice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAvailable for eligible orders\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBengaluru Presence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRT Nagar, Bengaluru\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller location varies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eInstitutional Procurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eLaboratory, clinic and hospital enquiries supported subject to availability\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eBuy Peerless CRP Turbidimetric Reagent in Bangalore\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMicrosidd India\u003c\/strong\u003e supplies professional diagnostic and laboratory products from \u003cstrong\u003eRT Nagar, Bengaluru\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eLaboratories searching for \u003cstrong\u003ePeerless CRP Turbidimetric reagent Bangalore\u003c\/strong\u003e, CRP Latex Turbidimetry reagent Bengaluru, CRP 1×50 mL reagent near me, CRP reagent supplier RT Nagar, biochemistry reagent supplier Bangalore or professional laboratory reagents Karnataka can check availability through Microsidd.com.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMicrosidd India – NAP\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBusiness Name:\u003c\/strong\u003e Microsidd India\u003cbr\u003e\u003cstrong\u003eAddress:\u003c\/strong\u003e 09, 2nd Floor, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India\u003cbr\u003e\u003cstrong\u003ePhone \/ WhatsApp:\u003c\/strong\u003e +91 63667 72288\u003cbr\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e support@microsidd.com\u003cbr\u003e\u003cstrong\u003eWebsite:\u003c\/strong\u003e https:\/\/microsidd.com\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.google.com\/maps\/place\/Microsidd+India\/@13.0193885,77.5967849,17z\/data=!4m14!1m7!3m6!1s0x3bae3d88d30dba57:0x8fc1ceef7bbff265!2sMicrosidd+India!8m2!3d13.0193885!4d77.5967849!16s%2Fg%2F11bw7cvpyd!3m5!1s0x3bae3d88d30dba57:0x8fc1ceef7bbff265!8m2!3d13.0193885!4d77.5967849!16s%2Fg%2F11bw7cvpyd?entry=ttu\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cstrong\u003eView Microsidd India on Google Maps\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions – Peerless CRP Turbidimetric Reagent\u003c\/h2\u003e\n\u003ch3\u003eWhat is the pack size?\u003c\/h3\u003e\n\u003cp\u003eThe pack size is \u003cstrong\u003e1 × 50 mL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method does this CRP reagent use?\u003c\/h3\u003e\n\u003cp\u003eIt uses \u003cstrong\u003elatex turbidimetry\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat sample is required?\u003c\/h3\u003e\n\u003cp\u003eThe supplied IFU specifies \u003cstrong\u003eserum\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer method uses \u003cstrong\u003e540 nm\u003c\/strong\u003e. The IFU specifies a photometer \/ spectrophotometer thermostatable at 37°C with a 540 ±20 nm filter for the manual method.\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe stated sample \/ calibrator volume is \u003cstrong\u003e10 µL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the working reagent volume?\u003c\/h3\u003e\n\u003cp\u003eThe stated working reagent volume is \u003cstrong\u003e1.0 mL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the reaction mode?\u003c\/h3\u003e\n\u003cp\u003eThe system parameter is \u003cstrong\u003eTwo Point Kinetic\u003c\/strong\u003e with an increasing reaction.\u003c\/p\u003e\n\u003ch3\u003eHow long is the measuring time?\u003c\/h3\u003e\n\u003cp\u003eThe IFU specifies a \u003cstrong\u003e10-second lag time\u003c\/strong\u003e and a \u003cstrong\u003e120-second measuring time\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003eThe stated linearity is \u003cstrong\u003eup to 150 mg\/L\u003c\/strong\u003e under the described assay conditions.\u003c\/p\u003e\n\u003ch3\u003eWhat should be done with samples above 150 mg\/L?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer IFU instructs that higher-concentration specimens should be diluted \u003cstrong\u003e1\/5 in 9 g\/L NaCl\u003c\/strong\u003e and retested.\u003c\/p\u003e\n\u003ch3\u003eWhat is the detection limit?\u003c\/h3\u003e\n\u003cp\u003eThe IFU states that values \u003cstrong\u003ebelow 1 mg\/L give non-reproducible results\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the prozone limit?\u003c\/h3\u003e\n\u003cp\u003eThe supplied analytical-performance section states a \u003cstrong\u003eprozone effect up to 250 mg\/L\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow should the reagent be stored?\u003c\/h3\u003e\n\u003cp\u003eStore tightly closed at \u003cstrong\u003e2–8°C\u003c\/strong\u003e and prevent contamination.\u003c\/p\u003e\n\u003ch3\u003eHow stable is the working reagent?\u003c\/h3\u003e\n\u003cp\u003eThe IFU states that the working reagent is stable for \u003cstrong\u003e20 days at 2–8°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow long is serum stable?\u003c\/h3\u003e\n\u003cp\u003eThe IFU states \u003cstrong\u003e7 days at 2–8°C\u003c\/strong\u003e or \u003cstrong\u003e3 months at −20°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the adult reference value?\u003c\/h3\u003e\n\u003cp\u003eThe IFU lists \u003cstrong\u003eup to 5 mg\/L\u003c\/strong\u003e for adults while advising each laboratory to establish its own reference range.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on different analysers?\u003c\/h3\u003e\n\u003cp\u003eThe IFU states that the method may be used with different instruments, but every analyser application should be validated to demonstrate acceptable performance.\u003c\/p\u003e\n\u003ch3\u003eAre calibrators required?\u003c\/h3\u003e\n\u003cp\u003eYes. The supplied calibrator uses human serum, and its CRP concentration is stated on the vial. The value is traceable to Certified Reference Material BCR 470 (IRMM).\u003c\/p\u003e\n\u003ch3\u003eIs quality control required?\u003c\/h3\u003e\n\u003cp\u003eYes. Control sera are recommended for both manual and automated procedures. Each laboratory should establish its own QC scheme and corrective actions.\u003c\/p\u003e\n\u003ch3\u003eCan CRP alone diagnose infection?\u003c\/h3\u003e\n\u003cp\u003eNo. CRP is a non-specific laboratory marker. Clinical diagnosis should not be based on a single CRP result.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProfessional IVD \/ Medical Disclaimer\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis reagent is for professional in-vitro diagnostic laboratory use by trained personnel.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll analyser settings, reagent preparation, calibration, quality control, specimen handling, calculations and result interpretation must follow the current Peerless \/ manufacturer IFU and the laboratory's validated SOP.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifically notes that applications to different instruments must be validated and periodically verified.\u003c\/p\u003e\n\u003cp\u003eCRP is a non-specific acute-phase marker. A single CRP result should not be used independently to diagnose the underlying disease, infection or inflammatory condition.\u003c\/p\u003e\n\u003cp\u003eThe current IFU supplied with the actual product lot takes precedence over information displayed on an ecommerce page.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eNo Return \/ No Exchange\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis professional laboratory reagent is non-returnable and non-exchangeable once correctly supplied.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Peerless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter:\u003c\/strong\u003e CRP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod:\u003c\/strong\u003e Latex Turbidimetry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack Size:\u003c\/strong\u003e 1 × 50 mL\u003c\/li\u003e\n\u003cli\u003eRequired analyser model\u003c\/li\u003e\n\u003cli\u003eAnalyser compatibility\u003c\/li\u003e\n\u003cli\u003eRequired application \/ method parameters\u003c\/li\u003e\n\u003cli\u003eCalibration requirement\u003c\/li\u003e\n\u003cli\u003eStorage requirements\u003c\/li\u003e\n\u003cli\u003eLot and expiry requirements where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOrdering an incompatible reagent, incorrect method or unsuitable pack configuration is not considered a product defect when the supplied product matches the confirmed order.\u003c\/p\u003e\n\u003cp\u003eLaboratory reagents are storage-, contamination- and expiry-sensitive products and cannot normally be returned to saleable inventory after delivery.\u003c\/p\u003e\n\u003cp\u003eIncorrect supply, verified transit damage or other valid claims will be handled according to the \u003ca href=\"https:\/\/microsidd.com\/pages\/cancellation-and-refunds\"\u003e\u003cstrong\u003eMicrosidd Refund, Return, Replacement \u0026amp; Cancellation Policy\u003c\/strong\u003e\u003c\/a\u003e and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for claims involving incorrect, missing or damaged products.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBegin recording before opening the parcel. Open the carton by \u003cstrong\u003ecutting the sealing tape carefully with a blade; do not tear the carton\u003c\/strong\u003e. Keep the courier label, sealed package, reagent packaging and product condition continuously visible.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003ePeerless CRP Turbidimetric – Product Entity Summary\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e CRP – Turbidimetric\u003cbr\u003e\u003cstrong\u003eMethod:\u003c\/strong\u003e Latex Turbidimetry\u003cbr\u003e\u003cstrong\u003ePack:\u003c\/strong\u003e 1 × 50 mL\u003cbr\u003e\u003cstrong\u003eMarketed By:\u003c\/strong\u003e Peerless Biotech Pvt. Ltd.\u003cbr\u003e\u003cstrong\u003eManufactured By:\u003c\/strong\u003e Asritha Diatech India Pvt. Ltd.\u003cbr\u003e\u003cstrong\u003eAnalyte:\u003c\/strong\u003e C-Reactive Protein \/ CRP\u003cbr\u003e\u003cstrong\u003eSpecimen:\u003c\/strong\u003e Serum\u003cbr\u003e\u003cstrong\u003eMode:\u003c\/strong\u003e Two Point Kinetic\u003cbr\u003e\u003cstrong\u003eReaction:\u003c\/strong\u003e Increasing\u003cbr\u003e\u003cstrong\u003eWavelength:\u003c\/strong\u003e 540 nm\u003cbr\u003e\u003cstrong\u003eSample Volume:\u003c\/strong\u003e 10 µL\u003cbr\u003e\u003cstrong\u003eWorking Reagent:\u003c\/strong\u003e 1.0 mL\u003cbr\u003e\u003cstrong\u003eLag Time:\u003c\/strong\u003e 10 seconds\u003cbr\u003e\u003cstrong\u003eMeasuring Time:\u003c\/strong\u003e 120 seconds\u003cbr\u003e\u003cstrong\u003eLinearity:\u003c\/strong\u003e Up to 150 mg\/L under stated conditions\u003cbr\u003e\u003cstrong\u003eDetection Limit:\u003c\/strong\u003e Values below 1 mg\/L stated as non-reproducible\u003cbr\u003e\u003cstrong\u003eProzone:\u003c\/strong\u003e Up to 250 mg\/L\u003cbr\u003e\u003cstrong\u003eReference Value:\u003c\/strong\u003e Adults up to 5 mg\/L; laboratory-specific range recommended\u003cbr\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e 2–8°C\u003cbr\u003e\u003cstrong\u003eProfessional Use:\u003c\/strong\u003e In-vitro diagnostic laboratory use\u003cbr\u003e\u003cstrong\u003eSupplier:\u003c\/strong\u003e Microsidd India, RT Nagar, Bengaluru\u003c\/p\u003e","brand":"Peerless","offers":[{"title":"Default Title","offer_id":68054743253312,"sku":"EURO CRPTURBI","price":1799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/PeerlessCRPReagentKitBox.png?v=1794076751","url":"https:\/\/microsidd.com\/products\/peerless-crp-turbidimetric-reagent-1x50ml","provider":"Microsidd India","version":"1.0","type":"link"}