{"product_id":"meril-merilyzer-eiaquant-elisa-reader","title":"Meril Merilyzer EIAQuant ELISA Microplate Reader – 96 Well","description":"\u003ch2\u003e\u003cspan\u003eCompact ELISA Reader for Professional Diagnostic Laboratories\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMeril Merilyzer EIAQuant ELISA Microplate Reader\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a professional laboratory instrument designed for photometric reading of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e96-well microtiter plates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e used in ELISA and other absorbance-based microplate assays.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system is designed for laboratories that require a compact ELISA reader with automated plate feeding, absorbance measurement, result calculation, data processing, quality-control support and built-in printing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith standard wavelengths of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e405 nm, 450 nm, 492 nm and 630 nm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, monochromatic and bichromatic reading modes, fast plate-reading capability and an interactive LCD touch screen, the EIAQuant is suitable for diagnostic laboratories, blood banks, hospital laboratories, serology departments and other professional ELISA workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eProduct Information\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Meril Diagnostics\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Name:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Merilyzer EIAQuant\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ELISA Microplate Reader\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCategory:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Laboratory Instruments\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSubcategory:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ELISA Reader \/ Microplate Reader\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePlate Format:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 96-Well Microtiter Plate\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Absorbance \/ Optical Density\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eStandard Wavelengths:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 405 nm, 450 nm, 492 nm, 630 nm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAdditional Filter Positions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 Optional Positions\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eReading Modes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Monochromatic and Bichromatic\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSingle-Wavelength Reading Speed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 6.5 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDual-Wavelength Reading Speed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 16 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOptical Density Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0–4.0 OD\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLight Source:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Halogen\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOptical System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Eight-Channel Fibre Optics\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDisplay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Large Interactive LCD Touch Screen\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePrinter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-In Thermal Printer\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eQC:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 4 Levels of Control Sera with Levey-Jennings Graph\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFunctions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Self Diagnosis, Copy Test, Rerun, Automatic Feeding, Automatic Measurement, Data Analysis and Processing\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIntended Use:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Professional Laboratory Use\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSuitable Users:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Diagnostic laboratories, blood banks, hospital laboratories, serology laboratories, research and clinical laboratories\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSeller:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Microsidd India\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLocation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e RT Nagar, Bengaluru, Karnataka\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWhat Is Merilyzer EIAQuant?\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMerilyzer EIAQuant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a compact ELISA microplate reader used to measure the absorbance of samples processed in a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e96-well microtiter plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is designed for laboratories performing qualitative and quantitative enzyme immunoassays where optical-density measurement is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument automates several parts of the reading workflow, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eplate feeding\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eabsorbance measurement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003edata processing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eresult analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQC review\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ereport printing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis makes it suitable for laboratories running routine ELISA assays for infectious disease, hormones and other compatible parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eFour Standard Wavelength Filters\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant includes four standard spectral filters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e405 nm\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e450 nm\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e492 nm\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e630 nm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe system also provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethree optional filter positions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for additional assay requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMonochromatic \u0026amp; Bichromatic Reading\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument supports both:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMonochromatic reading\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eand\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBichromatic reading\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eallowing laboratories to select the reading mode required by the assay protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFast Plate Reading\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMeril lists the reading speed as approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e6.5 seconds at single wavelength\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eand\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e16 seconds at dual wavelength\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003efor a compatible microplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e0–4.0 OD Dynamic Range\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument supports an optical-density range of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0 to 4.0 OD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing a broad absorbance measurement range for compatible ELISA assays.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEight-Channel Fibre-Optic System\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant uses an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eeight-channel fibre-optic optical system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing efficient microplate reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHalogen Light Source\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eA halogen light source is used for absorbance measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eInteractive Touch Screen\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eA large LCD touch screen provides direct instrument control and easier laboratory operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt-In Thermal Printer\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe integrated thermal printer allows laboratories to generate results without requiring a separate external printer for routine reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt-In Quality Control\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant supports up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efour levels of control sera\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLevey-Jennings graph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping laboratories monitor assay performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSelf-Diagnosis Function\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe system includes built-in self-diagnostic functionality to support routine instrument checks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCopy Test \u0026amp; Rerun Functions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument includes convenient workflow features such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCopy Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eand\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRerun\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003efor repeat or related assay processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeril Diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMerilyzer EIAQuant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInstrument Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eELISA Microplate Reader\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePlate Format\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e96-Well Microtiter Plate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAbsorbance \/ Optical Density\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandard Filters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e405, 450, 492, 630 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOptional Filter Positions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eReading Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMonochromatic \/ Bichromatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSingle-Wavelength Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 6.5 sec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDual-Wavelength Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 16 sec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOD Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–4.0 OD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLight Source\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHalogen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOptical System\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEight-Channel Fibre Optics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLarge LCD Touch Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePrinter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-In Thermal Printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eQC Levels\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eQC Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLevey-Jennings Graph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFunctions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSelf Diagnosis, Copy Test, Rerun\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePlate Feeding\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMeasurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eData Analysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfessional Laboratory Use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan\u003eHow the ELISA Reader Works\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eAfter an ELISA assay is completed in a 96-well plate, the microplate is placed into the EIAQuant.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument:\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003efeeds the plate into the optical system,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ereads absorbance at the selected wavelength,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003emeasures each well,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eprocesses the optical-density data,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eapplies the programmed test calculation,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003egenerates qualitative or quantitative results according to the configured assay,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003edisplays or prints the final report.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eThe exact wavelength, cut-off formula, calibration model and assay interpretation should be programmed according to the specific ELISA kit being used.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCompatible ELISA Applications\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant can be used with compatible ELISA assays requiring microplate absorbance measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical applications may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHIV ELISA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHCV ELISA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHBsAg ELISA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDengue ELISA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThyroid ELISA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHormone ELISA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInfectious-disease ELISA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSerology assays\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuantitative immunoassays\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQualitative ELISA screening\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAssay compatibility depends on the wavelength, plate format and protocol specified by the reagent manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCompatible Meril ELISA Kits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant naturally complements Meril’s own ELISA range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMeril MeriLisa HIV ELISA – 96 Tests\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/microsidd.com\/products\/merilisa-hiv-96t-pack?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\/products\/merilisa-hiv-96t-pack\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMeril MeriLisa HCV ELISA 3.0 – 96 Tests\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/microsidd.com\/products\/merilisa-hcv-elisa-3-0-96t-pack?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\/products\/merilisa-hcv-elisa-3-0-96t-pack\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMeril MeriLisa HBsAg ELISA – 96 Tests\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/microsidd.com\/products\/merilisa-hbsag-96t-pack?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\/products\/merilisa-hbsag-96t-pack\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eExplore the Full ELISA Range\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/elisa-range?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\/collections\/elisa-range\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eYour ELISA collection currently includes Meril HIV, HCV and HBsAg products alongside other professional ELISA kits, so linking this reader into that collection will make the category significantly stronger. \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/elisa-range\"\u003eMicrosidd India\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eELISA Reader vs ELISA Washer\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ELISA reader and ELISA washer perform different functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eInstrument\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eMain Function\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eELISA Reader\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasures optical density \/ absorbance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eELISA Washer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWashes microplate wells between assay steps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe reader interprets the final colour reaction, while the washer is used during the assay workflow to remove unbound reagents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor a complete ELISA laboratory setup, both instruments may be required depending on the test protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWho Can Use This Instrument?\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe Merilyzer EIAQuant is intended for trained laboratory professionals working in:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDiagnostic laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBlood banks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHospital laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSerology laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClinical microbiology laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePathology laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMedical colleges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResearch laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstitutional laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePublic-health laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTransfusion-medicine laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis is a professional laboratory instrument and is not intended for household or consumer self-testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eBenefits for Diagnostic Laboratories\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant provides several practical benefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ecompact laboratory footprint\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e96-well microplate reading\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003efast reading times\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ebuilt-in printer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003etouch-screen operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eautomatic plate feeding\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eautomatic measurement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eautomated data analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ebuilt-in QC functionality\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLevey-Jennings QC graphing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003emonochromatic and bichromatic reading\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003emultiple filter options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ewide optical-density range\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eQuality Control Features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eQuality-control monitoring is especially important in ELISA workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant supports:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUp to 4 levels of control sera\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ewith\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLevey-Jennings graphical display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis helps laboratories monitor control trends and detect shifts or analytical variation during routine testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCalibration \u0026amp; Quantitative Testing\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe EIAQuant can support quantitative ELISA workflows where the assay requires calibration curves.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe correct calibration model depends on the individual assay.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLaboratories should use the calibration approach specified by the ELISA kit manufacturer rather than applying a generic calculation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eQualitative Testing \u0026amp; Cut-Off Analysis\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eFor qualitative ELISA assays, the reader can process optical-density values and apply assay-specific cut-off calculations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument also supports grey-zone and reverse cut-off workflows where required by the programmed test method.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInterpretation should always follow the individual assay IFU.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eLaboratory Setup Requirements\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eA typical ELISA setup may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMerilyzer EIAQuant reader\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eELISA microplate washer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ecalibrated micropipettes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003edisposable pipette tips\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eELISA reagent kits\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eincubator where required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003erefrigerator for reagent storage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ecentrifuge where required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003etimer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003elaboratory computer if external data management is used\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eappropriate PPE\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eInstallation \u0026amp; Operation\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument should be installed on a stable, clean laboratory bench away from:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003edirect sunlight\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eexcessive vibration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003emoisture\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003edust\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eextreme temperature variation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eInstallation, calibration and commissioning should follow the manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOnly appropriately trained personnel should operate the reader.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eCleaning \u0026amp; Maintenance\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eRoutine maintenance should follow Meril’s operating manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGeneral laboratory practices include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ekeep the instrument clean and dry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eavoid reagent spills inside the plate chamber\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eclean external surfaces appropriately\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003euse only recommended service procedures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eavoid unauthorised disassembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eperiodically verify instrument performance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eperform preventive maintenance according to the manufacturer schedule\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan\u003eStorage \u0026amp; Transportation\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eFor transport or relocation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003euse the original protective packaging where available\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eprotect the instrument from impact and vibration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ekeep it dry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eavoid extreme temperature exposure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003etransport in the correct orientation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eallow the instrument to acclimatise before operation after significant temperature changes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eperform verification after installation or relocation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eExact transport and operating conditions should follow the current manufacturer manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eExplore Related Microsidd Collections\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003eELISA Range\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/elisa-range?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\/collections\/elisa-range\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBlood Bank Range\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/blood-bank-range\" style=\"color: rgb(43, 0, 255);\"\u003ehttps:\/\/microsidd.com\/collections\/blood-bank-range\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLaboratory Reagents \u0026amp; Kits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/chemicals-liquids?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\/collections\/chemicals-liquids\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eWhy Buy Meril EIAQuant from Microsidd?\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eMicrosidd India supplies professional diagnostic equipment, laboratory reagents, ELISA kits and blood-bank products to healthcare and laboratory customers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBenefits include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e✓ Genuine brand-specific laboratory equipment\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Meril ELISA kits available alongside the reader\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Dedicated ELISA collection\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Blood-bank and laboratory reagents available\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Technical product information before ordering\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Bengaluru-based support\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ GST invoice where applicable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Institutional supply support subject to availability\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Online ordering for serviceable locations across India\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Easier sourcing of compatible reagents and accessories from one supplier\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eBuy ELISA Reader in Bangalore \/ Bengaluru\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eMicrosidd India supplies \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eELISA readers and professional diagnostic laboratory products in Bengaluru\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and serves laboratories across serviceable locations in India.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProfessional buyers searching for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eELISA reader Bangalore\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003emicroplate reader Bengaluru\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMeril ELISA reader\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e96 well ELISA reader India\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eELISA equipment near me\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eblood bank ELISA equipment Bangalore\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eorder through Microsidd.com subject to stock and serviceability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eMicrosidd India – NAP\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBusiness Name:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Microsidd India\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAddress:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePhone \/ WhatsApp:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e +91 63667 72288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eEmail:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"mailto:support@microsidd.com\"\u003e\u003cspan\u003esupport@microsidd.com\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eWebsite:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/microsidd.com?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eWorking Hours:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Monday to Saturday, 10:00 AM – 6:00 PM IST\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFind Microsidd India on Google Maps\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.google.com\/maps\/search\/?api=1\u0026amp;query=Microsidd+India%2C+09+Green+Chambers%2C+14th+Cross%2C+RT+Nagar%2C+Bengaluru+560032\"\u003e\u003cspan\u003ehttps:\/\/www.google.com\/maps\/search\/?api=1\u0026amp;query=Microsidd+India%2C+09+Green+Chambers%2C+14th+Cross%2C+RT+Nagar%2C+Bengaluru+560032\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eStay Connected with Microsidd\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eSubscribe to Microsidd on YouTube\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratory product videos, diagnostic guides and product explainers:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/channel\/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1\"\u003e\u003cspan\u003ehttps:\/\/www.youtube.com\/channel\/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFollow the Microsidd WhatsApp Channel\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFor updates about new diagnostic products, laboratory equipment and offers:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/whatsapp.com\/channel\/0029Va5lCoi1nozBZBL1gx3P\"\u003e\u003cspan\u003ehttps:\/\/whatsapp.com\/channel\/0029Va5lCoi1nozBZBL1gx3P\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the Meril Merilyzer EIAQuant?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIt is a professional \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e96-well ELISA microplate reader\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e used to measure absorbance in ELISA and compatible microplate assays. \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.merillife.com\/our-products\/diagnostics\/merilyzer-eiaquant\"\u003eMeril Life\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat plate size does it support?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIt is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e96-well microtiter plates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhich wavelengths are included?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe standard filters are:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e405 nm, 450 nm, 492 nm and 630 nm.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAre additional filters available?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. The instrument has \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ethree optional filter positions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes it support dual-wavelength reading?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. It supports both monochromatic and bichromatic reading. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the reading speed?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMeril lists approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e6.5 seconds at single wavelength\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e16 seconds at dual wavelength\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the optical-density range?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument supports a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0–4.0 OD dynamic range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes it have a built-in printer?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. It includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt-in thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes it have a touch screen?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. It uses a large interactive LCD touch screen. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes it support quality control?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. It supports up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efour levels of control sera with Levey-Jennings graphing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan it be used for HIV ELISA?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes, if the HIV ELISA assay uses compatible wavelengths and a 96-well plate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan it be used for HCV ELISA?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes, subject to assay compatibility and programming.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan it be used for HBsAg ELISA?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes, subject to the assay IFU and wavelength requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan it be used for quantitative ELISA?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes, where the assay requires absorbance-based quantitative calculation and the appropriate calibration model is programmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan it be used for qualitative ELISA?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the instrument automatically analyse data?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Meril describes automatic measurement, data analysis and processing. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes it include self-diagnosis?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Self Diagnosis is one of the listed functions. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the test be rerun?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRerun option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIs this product for home use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eNo. It is professional laboratory equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes an ELISA reader perform washing?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eNo. Plate washing is normally performed with an ELISA washer or validated manual washing process.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes Microsidd also supply ELISA kits?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBrowse: \u003c\/span\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/elisa-range?utm_source=chatgpt.com\"\u003e\u003cspan\u003ehttps:\/\/microsidd.com\/collections\/elisa-range\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes Microsidd supply blood-bank products?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. \u003c\/span\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/microsidd.com\/collections\/blood-bank-range\" style=\"color: rgb(43, 0, 255);\"\u003ehttps:\/\/microsidd.com\/collections\/blood-bank-range\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eNo Return \/ No Exchange Policy\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThis product is non-returnable and non-exchangeable, has 2 years warranty \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease verify the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebrand, model, application, wavelength requirements, plate compatibility, assay requirements, instrument specifications and installation requirements before placing your order\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor laboratory equipment, customers should specifically verify the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erequired test methodology, compatible ELISA kit, wavelength, plate format, laboratory infrastructure and intended workflow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGenuine cases involving an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eincorrect product received\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cspan\u003eProfessional \/ Laboratory Disclaimer\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMeril Merilyzer EIAQuant is intended for professional laboratory use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe instrument must be installed, operated, calibrated and maintained by appropriately trained personnel according to the manufacturer’s current operating instructions, laboratory SOPs, quality-control procedures and applicable regulatory requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTest results depend on the performance of the complete analytical system, including the assay kit, specimen quality, instrument programming, wavelength selection, calibration, QC and laboratory procedure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eClinical decisions should not be based solely on an instrument reading without appropriate assay validation and professional interpretation.\u003c\/span\u003e\u003c\/p\u003e","brand":"MERIL DIAGNOSTICS","offers":[{"title":"Default Title","offer_id":67582310416704,"sku":"Meril EIA Reader","price":159000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/Merilyzer_EIA_Quantelisareader.png?v=1790445244","url":"https:\/\/microsidd.com\/products\/meril-merilyzer-eiaquant-elisa-reader","provider":"Microsidd India","version":"1.0","type":"link"}