{"product_id":"magnesium-reagent","title":"Magnesium Electrolyte Reagent Kit 2 × 50 ml – Xylidyl Blue \/ EGTA Method","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed Magnesium Electrolyte Reagent Kit 2 × 50 ml\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Magnesium Electrolyte Reagent Kit 2 × 50 ml\u003c\/strong\u003e is a professional clinical biochemistry reagent intended for the \u003cstrong\u003equantitative determination of magnesium in serum and plasma\u003c\/strong\u003e using the \u003cstrong\u003eXylidyl Blue method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwemed’s official literature states that magnesium ions react with \u003cstrong\u003eXylidyl Blue under alkaline conditions\u003c\/strong\u003e to form a purple-red chelate complex. The intensity of the colour produced is directly proportional to the magnesium concentration in the specimen. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSwemed’s current catalogue lists \u003cstrong\u003eMagnesium 2 × 50 ml\u003c\/strong\u003e, product code \u003cstrong\u003eMAG 717\u003c\/strong\u003e, with \u003cstrong\u003eEGTA\u003c\/strong\u003e as the stated method classification and a 24-month shelf life. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is intended for professional pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories, including compatible \u003cstrong\u003eopen-system fully automatic and semi-automatic biochemistry analysers\u003c\/strong\u003e after method programming and laboratory validation.\u003c\/p\u003e\n\u003ch2\u003eProduct at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eMagnesium Electrolyte Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 × 50 ml\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Code\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMAG 717\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eMagnesium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eXylidyl Blue \/ EGTA Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Mode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Concentration\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 minutes at room temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1–5.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 5.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum \/ Heparin Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Preparation\u003c\/td\u003e\n\u003ctd\u003eReady to Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Storage\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18–30°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFreezing\u003c\/td\u003e\n\u003ctd\u003eDo Not Freeze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyser Compatibility\u003c\/td\u003e\n\u003ctd\u003eOpen-System Fully Automatic \u0026amp; Semi-Automatic Biochemistry Analysers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eProfessional In Vitro Diagnostic Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru, Karnataka, India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe assay parameters above are provided in Swemed’s official Magnesium insert. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics Magnesium Reagent Kit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003ePack size: \u003cstrong\u003e2 × 50 ml\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct code: \u003cstrong\u003eMAG 717\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eXylidyl Blue \/ EGTA method\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eReady-to-use reagent\u003c\/li\u003e\n\u003cli\u003eReady-to-use magnesium standard\u003c\/li\u003e\n\u003cli\u003eEndpoint colorimetric assay\u003c\/li\u003e\n\u003cli\u003eMeasurement wavelength: \u003cstrong\u003e505 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eStandard concentration: \u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample volume: \u003cstrong\u003e10 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReagent volume: \u003cstrong\u003e1000 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncubation: \u003cstrong\u003e10 minutes at room temperature\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasuring range: \u003cstrong\u003e1–5.0 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLinearity up to \u003cstrong\u003e5.0 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for serum and heparin plasma\u003c\/li\u003e\n\u003cli\u003eCompatible with open-system semi-auto analysers\u003c\/li\u003e\n\u003cli\u003eCompatible with open-system fully automatic analysers\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eWhy Magnesium Testing Is Important\u003c\/h1\u003e\n\u003cp\u003eMagnesium is a major intracellular cation and plays an important role in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnzyme activation\u003c\/li\u003e\n\u003cli\u003eProtein synthesis\u003c\/li\u003e\n\u003cli\u003eAmino-acid activation\u003c\/li\u003e\n\u003cli\u003eNeuromuscular function\u003c\/li\u003e\n\u003cli\u003eElectrolyte balance\u003c\/li\u003e\n\u003cli\u003eRenal and metabolic physiology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSwemed notes that increased magnesium levels may occur in conditions such as \u003cstrong\u003edehydration, Addison’s disease and uraemia\u003c\/strong\u003e, while decreased levels may be seen in \u003cstrong\u003emalabsorption, chronic renal disease, chronic alcoholism, hyperthyroidism, pancreatitis and during treatment of diabetic coma\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMagnesium is commonly evaluated together with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSodium\u003c\/li\u003e\n\u003cli\u003ePotassium\u003c\/li\u003e\n\u003cli\u003eChloride\u003c\/li\u003e\n\u003cli\u003eCalcium\u003c\/li\u003e\n\u003cli\u003ePhosphorus\u003c\/li\u003e\n\u003cli\u003eUrea\u003c\/li\u003e\n\u003cli\u003eCreatinine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eTest Principle\u003c\/h1\u003e\n\u003cp\u003eMagnesium ions react with \u003cstrong\u003eXylidyl Blue in an alkaline medium\u003c\/strong\u003e to form a coloured magnesium-Xylidyl Blue complex.\u003c\/p\u003e\n\u003cp\u003eThe intensity of the purple-red colour formed is proportional to the magnesium concentration in the specimen. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eReagent Composition\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTris Buffer pH 10\u003c\/td\u003e\n\u003ctd\u003e24.2 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXylidyl Blue\u003c\/td\u003e\n\u003ctd\u003e50.3 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Carbonate\u003c\/td\u003e\n\u003ctd\u003e10.3 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEGTA\u003c\/td\u003e\n\u003ctd\u003e19.0 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSodium Azide\u003c\/td\u003e\n\u003ctd\u003e500 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Standard\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003eReagent Preparation\u003c\/h1\u003e\n\u003cp\u003eSwemed states that:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe reagent and standard are ready to use.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis makes the product convenient for routine clinical chemistry workflows without reagent reconstitution.\u003c\/p\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSwemed Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest\u003c\/td\u003e\n\u003ctd\u003eMagnesium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eXylidyl Blue \/ EGTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Concentration\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Slope\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 minutes at room temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking\u003c\/td\u003e\n\u003ctd\u003eReagent Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1–5.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1\u003eAssay Procedure Summary\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTube\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eReagent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStandard \/ Sample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e10 µl Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e10 µl Sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eMix and incubate for:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10 minutes at room temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThen measure the absorbance of the sample and standard against the reagent blank at:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eCalculation\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eMagnesium (mg\/dL) = Absorbance of Sample ÷ Absorbance of Standard × Concentration of Standard\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer standard:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eCompatible with Open-System Biochemistry Analysers\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Magnesium Reagent Kit\u003c\/strong\u003e can be used with compatible open-system analysers that allow the required endpoint application to be programmed.\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eOpen-System Setting\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMagnesium Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e37°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 minutes at RT\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank\u003c\/td\u003e\n\u003ctd\u003eReagent Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003emg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSuitable analyser categories include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eOpen-system semi-automatic biochemistry analysers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOpen-system fully automatic biochemistry analysers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eProgrammable chemistry systems supporting 505 nm endpoint measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe laboratory should verify analyser compatibility and validate the application before routine patient reporting.\u003c\/p\u003e\n\u003ch1\u003eSpecimen Requirements\u003c\/h1\u003e\n\u003cp\u003eSwemed lists:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSerum\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeparin plasma\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFresh, clear, \u003cstrong\u003enon-haemolysed serum\u003c\/strong\u003e is recommended.\u003c\/p\u003e\n\u003cp\u003eThis is particularly important because erythrocytes contain higher magnesium concentrations than serum, so haemolysis can produce falsely elevated magnesium results. Swemed advises that visibly haemolysed specimens should not be used. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eAnticoagulants to Avoid\u003c\/h1\u003e\n\u003cp\u003eSwemed advises avoiding:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEDTA\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSodium fluoride\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOxalate\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ebecause these substances can interfere with the assay. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe manufacturer also notes that trace chelating agents such as \u003cstrong\u003eEDTA, oxalate and citrate\u003c\/strong\u003e can prevent formation of the colour complex. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eSpecimen Stability\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecimen\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerum \/ Plasma at 2–8°C\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 days\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eContaminated specimens should be discarded. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eMeasuring Range and Linearity\u003c\/h1\u003e\n\u003cp\u003eThe assay is designed to measure magnesium concentrations in the range:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1–5.0 mg\/dL\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe stated linearity is:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor samples above the measuring range, Swemed recommends dilution \u003cstrong\u003e1 + 1 with 0.9% NaCl\u003c\/strong\u003e, repeating the test and multiplying the obtained result by \u003cstrong\u003e2\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eImportant Laboratory Precautions\u003c\/h1\u003e\n\u003cp\u003eSwemed specifically recommends:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvoid visibly haemolysed specimens\u003c\/li\u003e\n\u003cli\u003eSeparate serum from the clot promptly\u003c\/li\u003e\n\u003cli\u003eAvoid chelating agents such as EDTA, oxalate and citrate\u003c\/li\u003e\n\u003cli\u003eUse clean glassware\u003c\/li\u003e\n\u003cli\u003eRinse glassware with \u003cstrong\u003e1% or 0.1 N HCl\u003c\/strong\u003e, followed by good-quality deionised water before testing \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese precautions are especially important in magnesium testing because trace contamination or chelation can affect analytical performance.\u003c\/p\u003e\n\u003ch1\u003eManufacturer Reference Range\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003ePopulation\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Reference Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNewborn\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.2–2.6 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChildren\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.5–2.3 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWomen\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.9–2.5 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMen\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.8–2.6 mg\/dL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSwemed recommends that each laboratory establish or verify its own reference interval for its patient population. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eStorage and Stability\u003c\/h1\u003e\n\u003cp\u003eStore the reagent:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e18–30°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtected from light\u003c\/li\u003e\n\u003cli\u003eProtected from contamination\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDo not freeze\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUse only within the labelled expiry date \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSwemed lists possible signs of deterioration as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReagent blank absorbance at 505 nm above \u003cstrong\u003e1.0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVisible particles\u003c\/li\u003e\n\u003cli\u003eTurbidity \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe current Swemed catalogue lists a \u003cstrong\u003e24-month shelf life\u003c\/strong\u003e for Magnesium when stored correctly. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003eSafety and Precautions\u003c\/h1\u003e\n\u003cp\u003eThe reagent contains \u003cstrong\u003esodium azide preservative\u003c\/strong\u003e and should be handled using routine laboratory safety precautions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eProfessional users should:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWear suitable gloves\u003c\/li\u003e\n\u003cli\u003eUse eye\/face protection\u003c\/li\u003e\n\u003cli\u003eAvoid skin or mucous-membrane contact\u003c\/li\u003e\n\u003cli\u003eNever pipette by mouth\u003c\/li\u003e\n\u003cli\u003eFollow current Good Laboratory Practice\u003c\/li\u003e\n\u003cli\u003eDispose of reagent according to institutional procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eMagnesium in an Electrolyte \/ Renal Profile\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLaboratory Relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium\u003c\/td\u003e\n\u003ctd\u003eIntracellular mineral and enzyme-related function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSodium\u003c\/td\u003e\n\u003ctd\u003eExtracellular fluid balance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium\u003c\/td\u003e\n\u003ctd\u003eCardiac and intracellular electrolyte balance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride\u003c\/td\u003e\n\u003ctd\u003eFluid and acid-base balance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium\u003c\/td\u003e\n\u003ctd\u003eMineral and neuromuscular function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorus\u003c\/td\u003e\n\u003ctd\u003eBone and renal metabolism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUrea\u003c\/td\u003e\n\u003ctd\u003eRenal and protein metabolism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCreatinine\u003c\/td\u003e\n\u003ctd\u003eRenal filtration assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eWho Can Buy This Product?\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine magnesium testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eElectrolyte and metabolic testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNephrology Centres\u003c\/td\u003e\n\u003ctd\u003eRenal and electrolyte monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDialysis Centres\u003c\/td\u003e\n\u003ctd\u003eMineral and electrolyte testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndocrinology Centres\u003c\/td\u003e\n\u003ctd\u003eMetabolic and electrolyte investigation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine magnesium estimation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eTeaching and diagnostic laboratory use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eInstitutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional supply where permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eUseful Tips Before Ordering\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that \u003cstrong\u003eMagnesium – Xylidyl Blue \/ EGTA Method\u003c\/strong\u003e is required.\u003c\/li\u003e\n\u003cli\u003eVerify the pack size: \u003cstrong\u003e2 × 50 ml\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm analyser support for \u003cstrong\u003e505 nm endpoint measurement\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify that your analyser is an \u003cstrong\u003eopen system\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm sample volume: \u003cstrong\u003e10 µl\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm reagent volume: \u003cstrong\u003e1000 µl\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify the standard concentration: \u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAvoid haemolysed samples.\u003c\/li\u003e\n\u003cli\u003eAvoid EDTA, oxalate, citrate and sodium fluoride contamination.\u003c\/li\u003e\n\u003cli\u003eStore reagent at \u003cstrong\u003e18–30°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDo not freeze.\u003c\/li\u003e\n\u003cli\u003ePerform calibration and internal quality control before routine use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eBuy Swemed Magnesium Reagent in Bangalore\u003c\/h1\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003eelectrolyte reagents, renal-profile reagents and clinical biochemistry products from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Magnesium Electrolyte Reagent Kit 2 × 50 ml\u003c\/strong\u003e is suitable for pathology laboratories, diagnostic centres, hospitals, nephrology facilities, dialysis centres and professional clinical chemistry laboratories using compatible open-system analysers.\u003c\/p\u003e\n\u003cp\u003eThe product can be ordered through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e, subject to stock availability and serviceability.\u003c\/p\u003e\n\u003ch1\u003eSearch Relevance\u003c\/h1\u003e\n\u003cp\u003eRelevant buyer searches include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMagnesium reagent supplier in Bangalore\u003c\/li\u003e\n\u003cli\u003eSwemed Magnesium Reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eMagnesium electrolyte reagent Bengaluru\u003c\/li\u003e\n\u003cli\u003eXylidyl Blue magnesium reagent India\u003c\/li\u003e\n\u003cli\u003eMagnesium reagent 2 × 50 ml\u003c\/li\u003e\n\u003cli\u003eMagnesium reagent for semi auto analyser\u003c\/li\u003e\n\u003cli\u003eMagnesium reagent for fully automatic analyser\u003c\/li\u003e\n\u003cli\u003eOpen system magnesium reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eElectrolyte reagent supplier Bengaluru\u003c\/li\u003e\n\u003cli\u003eRenal profile reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier near me\u003c\/li\u003e\n\u003cli\u003eSwemed Diagnostics magnesium reagent India\u003c\/li\u003e\n\u003cli\u003eLaboratory reagent supplier in bangalore\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eProduct Summary\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed Magnesium Reagent Kit?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Magnesium Electrolyte Reagent Kit 2 × 50 ml\u003c\/strong\u003e is a ready-to-use professional clinical chemistry reagent for quantitative magnesium determination using the \u003cstrong\u003eXylidyl Blue \/ EGTA endpoint method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method is used?\u003c\/h3\u003e\n\u003cp\u003eSwemed’s product insert identifies the assay as the \u003cstrong\u003eXylidyl Blue Method\u003c\/strong\u003e, while the current catalogue classifies the product method as \u003cstrong\u003eEGTA\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reagent volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the magnesium standard concentration?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the measuring range?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1–5.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e5.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich specimens can be used?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSerum and heparin plasma\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhy should haemolysed samples be avoided?\u003c\/h3\u003e\n\u003cp\u003eRed blood cells contain more magnesium than serum, so haemolysis can cause falsely elevated results. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the reagent ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. Swemed states that the \u003cstrong\u003ereagent and standard are ready to use\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan it be used on semi-automatic analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible \u003cstrong\u003eopen-system semi-automatic biochemistry analysers\u003c\/strong\u003e after method programming and validation.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on fully automatic analysers?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible \u003cstrong\u003eopen-system fully automatic biochemistry analysers\u003c\/strong\u003e that allow third-party reagent programming and support the required endpoint parameters.\u003c\/p\u003e\n\u003ch1\u003eInformation\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eMagnesium Electrolyte Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e2 × 50 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Code\u003c\/td\u003e\n\u003ctd\u003eMAG 717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyte\u003c\/td\u003e\n\u003ctd\u003eMagnesium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eXylidyl Blue \/ EGTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e505 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003emg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum \/ Heparin Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eElectrolytes \/ Renal \/ Metabolic Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubcategory\u003c\/td\u003e\n\u003ctd\u003eBiochemistry Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyser Compatibility\u003c\/td\u003e\n\u003ctd\u003eOpen-System Fully Automatic \u0026amp; Semi-Automatic Analysers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"relative w-full mt-4 mb-1\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"contents\"\u003e\n\u003cdiv class=\"relative\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eWhy Buy Swemed Magnesium Reagent from Microsidd.com?\u003c\/h1\u003e\n\u003cp\u003eElectrolyte and mineral reagents should be purchased only after verifying the \u003cstrong\u003ecorrect analyte, methodology, wavelength, sample type, pack size, storage requirements and analyser compatibility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMicrosidd India specialises in laboratory and diagnostic products and has long-standing experience in the IVD sector, helping professional buyers verify technical requirements before ordering.\u003c\/p\u003e\n\u003ch2\u003eMicrosidd.com vs Online Marketplaces vs Offline Suppliers\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLarge Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline \/ Local Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Specialisation\u003c\/td\u003e\n\u003ctd\u003eDiagnostic \u0026amp; laboratory focused\u003c\/td\u003e\n\u003ctd\u003eSeller expertise varies\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod Verification\u003c\/td\u003e\n\u003ctd\u003eXylidyl Blue \/ EGTA can be confirmed\u003c\/td\u003e\n\u003ctd\u003eListing details may be limited\u003c\/td\u003e\n\u003ctd\u003eDepends on dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Verification\u003c\/td\u003e\n\u003ctd\u003e2 × 50 ml can be checked\u003c\/td\u003e\n\u003ctd\u003ePack listing may vary\u003c\/td\u003e\n\u003ctd\u003eStock dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-System Guidance\u003c\/td\u003e\n\u003ctd\u003eBetter suited to analyser-specific enquiries\u003c\/td\u003e\n\u003ctd\u003eOften limited\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Support\u003c\/td\u003e\n\u003ctd\u003eTechnical parameters can be checked before ordering\u003c\/td\u003e\n\u003ctd\u003eGeneral support\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for labs and institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eUsually local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSpecialist electrolyte and biochemistry catalogue\u003c\/td\u003e\n\u003ctd\u003eBroad but not specialised\u003c\/td\u003e\n\u003ctd\u003eOften limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect Microsidd support\u003c\/td\u003e\n\u003ctd\u003eMarketplace + seller layer\u003c\/td\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eSubject to serviceability\u003c\/td\u003e\n\u003ctd\u003eBroad\u003c\/td\u003e\n\u003ctd\u003eUsually regional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed Magnesium Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is used for quantitative determination of \u003cstrong\u003emagnesium in serum and plasma\u003c\/strong\u003e using the Xylidyl Blue method. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the pack size?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e2 × 50 ml\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method does it use?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eXylidyl Blue \/ EGTA Method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e505 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay mode?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEndpoint\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e10 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reagent volume?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1000 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the standard concentration?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e2.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the measuring range?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1–5.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e5.0 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the reagent ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. Both the reagent and standard are \u003cstrong\u003eready to use\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan haemolysed samples be used?\u003c\/h3\u003e\n\u003cp\u003eNo. Swemed advises against visibly haemolysed specimens because erythrocytes contain high magnesium concentrations. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich anticoagulants should be avoided?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEDTA, sodium fluoride and oxalate\u003c\/strong\u003e should be avoided. Trace citrate can also interfere because chelating agents prevent formation of the colour complex. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow should the reagent be stored?\u003c\/h3\u003e\n\u003cp\u003eAt \u003cstrong\u003e18–30°C\u003c\/strong\u003e, protected from light and contamination. Do not freeze. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan it be used on a semi-auto analyser?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible \u003cstrong\u003eopen-system semi-automatic biochemistry analysers\u003c\/strong\u003e after programming and validation.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on a fully automatic analyser?\u003c\/h3\u003e\n\u003cp\u003eYes, on compatible \u003cstrong\u003eopen-system fully automatic analysers\u003c\/strong\u003e supporting the required endpoint application.\u003c\/p\u003e\n\u003ch3\u003eIs this for home testing?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1\u003eMedical and Laboratory Disclaimer\u003c\/h1\u003e\n\u003cp\u003eThe information on this product page is provided for \u003cstrong\u003egeneral product identification, procurement and laboratory educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMagnesium results should not be interpreted independently to diagnose or exclude renal, endocrine, gastrointestinal, metabolic or electrolyte disorders. Results should be correlated with clinical history, calcium, potassium, renal-function tests and other relevant investigations.\u003c\/p\u003e\n\u003cp\u003eBecause haemolysis, chelating agents and glassware contamination can significantly affect magnesium measurement, correct specimen handling and laboratory technique are especially important.\u003c\/p\u003e\n\u003cp\u003eFor open-system fully automatic and semi-automatic analysers, \u003cstrong\u003einstrument compatibility, application settings, calibration, quality control and analytical performance must be verified and validated by the laboratory before routine patient reporting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe current Swemed package insert supplied with the actual product lot should always be treated as the definitive technical specification.\u003c\/p\u003e\n\u003ch1\u003eNo Return \/ No Exchange Policy\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Swemed Diagnostics","offers":[{"title":"Default Title","offer_id":53147844018496,"sku":"Magnesium 100ml","price":1000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/Swemed_Magnesium_Reagent_2x50ml_Xylidyl_Blue_Method_Microsidd.png?v=1789290398","url":"https:\/\/microsidd.com\/products\/magnesium-reagent","provider":"Microsidd India","version":"1.0","type":"link"}