{"product_id":"ldh-reagent-kit-25-ml-modified-ifcc-optimized-dgkc-kinetic-method","title":"LDH Reagent Kit 25 ml – Modified IFCC \/ Optimized DGKC Kinetic Method","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed LDH Reagent Kit 25 ml\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit 25 ml\u003c\/strong\u003e is a professional \u003cstrong\u003eclinical biochemistry reagent\u003c\/strong\u003e intended for quantitative determination of \u003cstrong\u003eLactate Dehydrogenase (LDH) activity\u003c\/strong\u003e in serum using a kinetic UV method.\u003c\/p\u003e\n\u003cp\u003eSwemed’s current catalogue describes LDH under its cardiac reagent range as an \u003cstrong\u003eOptimized DGKC method\u003c\/strong\u003e based on the \u003cstrong\u003epyruvate-to-lactate reaction\u003c\/strong\u003e, with liquid-stable ready-to-use reagents, high working-reagent stability and a convenient \u003cstrong\u003e25 ml pack size\u003c\/strong\u003e. The current Swemed LDH product literature labels the assay as a \u003cstrong\u003eModified IFCC Method\u003c\/strong\u003e. Both describe the same pyruvate-to-lactate kinetic LDH principle. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe test measures the rate at which \u003cstrong\u003eNADH is oxidized to NAD+\u003c\/strong\u003e during the LDH-catalysed conversion of pyruvate to lactate. The resulting decrease in absorbance is proportional to the LDH activity present in the specimen. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e in pathology laboratories, hospital laboratories, diagnostic centres and clinical chemistry facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eLDH Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e25 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eLDH25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eClinical Biochemistry Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eLactate Dehydrogenase \/ LDH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eModified IFCC \/ Optimized DGKC Kinetic Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction\u003c\/td\u003e\n\u003ctd\u003ePyruvate → Lactate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eUV Kinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003eDecreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum, Heparin Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e25 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Interval\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalculation Factor\u003c\/td\u003e\n\u003ctd\u003e8199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Insert Linearity\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Reagent\u003c\/td\u003e\n\u003ctd\u003eR1 + R2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eProfessional In Vitro Diagnostic Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru, Karnataka, India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe assay parameters above are from the official Swemed LDH product literature. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics LDH Reagent Kit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eConvenient \u003cstrong\u003e25 ml pack size\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModified IFCC \/ Optimized DGKC kinetic method\u003c\/li\u003e\n\u003cli\u003ePyruvate-to-lactate reaction\u003c\/li\u003e\n\u003cli\u003eUV kinetic measurement at \u003cstrong\u003e340 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for serum and heparin plasma\u003c\/li\u003e\n\u003cli\u003eReaction performed at \u003cstrong\u003e37°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReady-to-use R1 and R2 components\u003c\/li\u003e\n\u003cli\u003eWorking reagent prepared at \u003cstrong\u003e4 parts R1 + 1 part R2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWorking reagent stability stated as \u003cstrong\u003e1 week at 2–8°C\u003c\/strong\u003e in the product insert\u003c\/li\u003e\n\u003cli\u003eSuitable for routine clinical chemistry testing\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Benefits\u003c\/h1\u003e\n\u003ch2\u003eKinetic UV Measurement\u003c\/h2\u003e\n\u003cp\u003eThe Swemed LDH assay uses a kinetic UV method in which the decrease in NADH absorbance at \u003cstrong\u003e340 nm\u003c\/strong\u003e is measured over time, providing a direct rate-based estimate of LDH enzyme activity. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eDefined Two-Reagent System\u003c\/h2\u003e\n\u003cp\u003eThe kit uses \u003cstrong\u003eR1 and R2\u003c\/strong\u003e, which can be combined in a \u003cstrong\u003e4:1 ratio\u003c\/strong\u003e to form the working reagent. The manufacturer also permits direct use of \u003cstrong\u003e0.8 ml R1 + 0.2 ml R2\u003c\/strong\u003e during the assay. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eConvenient 25 ml Pack\u003c\/h2\u003e\n\u003cp\u003eSwemed specifically lists a \u003cstrong\u003e25 ml LDH pack\u003c\/strong\u003e for laboratories with routine or moderate LDH workloads. Its latest catalogue highlights this pack as a convenient size. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSuitable for Routine Clinical Chemistry\u003c\/h2\u003e\n\u003cp\u003eLDH measurement is used in a variety of laboratory investigations involving tissue injury and enzyme activity assessment.\u003c\/p\u003e\n\u003ch2\u003eSpecialist Laboratory Use\u003c\/h2\u003e\n\u003cp\u003eThe reagent is designed for trained laboratory personnel following validated analyser settings, internal quality control and current manufacturer instructions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eIntended Use\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit 25 ml\u003c\/strong\u003e is intended for quantitative determination of \u003cstrong\u003eLactate Dehydrogenase activity\u003c\/strong\u003e in serum and compatible heparin plasma.\u003c\/p\u003e\n\u003cp\u003eThe product insert specifically identifies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSerum\u003c\/li\u003e\n\u003cli\u003eHeparin plasma\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt also states that \u003cstrong\u003eEDTA and sodium citrate should not be used\u003c\/strong\u003e because they may inhibit the assay. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTest Principle\u003c\/h1\u003e\n\u003cp\u003eLDH catalyses the reduction of pyruvate to lactate while NADH is oxidized to NAD+:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePyruvate + NADH + H+ → Lactate + NAD+\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe rate of decrease in absorbance caused by NADH oxidation is directly proportional to the amount of LDH activity present in the sample. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eReagent Preparation\u003c\/h1\u003e\n\u003cp\u003eSwemed instructs laboratories to prepare the working reagent by mixing:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4 parts Reagent R1 + 1 part Reagent R2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manufacturer states that the prepared working reagent remains stable for \u003cstrong\u003e1 week at 2–8°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAn alternative direct assay setup is:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eR1: 0.8 ml\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eR2: 0.2 ml\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe combined reagent should have an absorbance \u003cstrong\u003eabove 1.0 against distilled water at 340 nm\u003c\/strong\u003e. If the absorbance is below this level, the reagent should be discarded. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eReagent Composition\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eComposition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eTris buffer pH 7.0 – 6 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eEDTA – 1.5 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eSodium Pyruvate – 0.2 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eL-Alanine – 44.5 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 2\u003c\/td\u003e\n\u003ctd\u003eKH₂PO₄ – 0.9 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 2\u003c\/td\u003e\n\u003ctd\u003eK₂HPO₄ – 0.8 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe reagents also contain sodium azide as a preservative according to the manufacturer insert. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTest Parameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eLDH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eKinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003eIU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Slope\u003c\/td\u003e\n\u003ctd\u003eDecreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e25 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelta \/ Reading Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking\u003c\/td\u003e\n\u003ctd\u003eWater Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e8199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e1000 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese quick-reference parameters are provided in the official Swemed LDH insert. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManual Assay Procedure\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMacro Method\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSemi-Micro Method\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent R1 + R2\u003c\/td\u003e\n\u003ctd\u003e800 + 200 µl\u003c\/td\u003e\n\u003ctd\u003e400 + 100 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e25 µl\u003c\/td\u003e\n\u003ctd\u003e12.5 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eMix well and measure the initial absorbance after \u003cstrong\u003e1 minute\u003c\/strong\u003e, then repeat readings at approximately \u003cstrong\u003e1-minute intervals for 3 minutes\u003c\/strong\u003e. Calculate the mean absorbance change per minute. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCalculation\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLDH (U\/L) = ΔA\/min × 8199\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Requirements\u003c\/h1\u003e\n\u003cp\u003eSwemed recommends:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-haemolysed serum\u003c\/li\u003e\n\u003cli\u003eHeparin plasma\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant manufacturer precautions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not use haemolysed samples\u003c\/strong\u003e, because red blood cells contain high concentrations of LDH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDo not use EDTA or sodium citrate plasma\u003c\/strong\u003e, because they may inhibit the assay.\u003c\/li\u003e\n\u003cli\u003eAvoid lipemic samples where possible. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Stability\u003c\/h1\u003e\n\u003cp\u003eThe Swemed literature states:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecimen\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerum\u003c\/td\u003e\n\u003ctd\u003eApproximately 1–3 days at 2–8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe manufacturer also notes that \u003cstrong\u003efreezing can inactivate liver LDH isoenzymes\u003c\/strong\u003e, so specimen handling should follow the laboratory’s validated procedure. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMeasuring Range and Linearity\u003c\/h1\u003e\n\u003cp\u003eThe official LDH insert states that the method is linear up to \u003cstrong\u003e1000 U\/L\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor samples exceeding this level, Swemed recommends dilution \u003cstrong\u003e1 + 5 with physiological saline\u003c\/strong\u003e, repeating the assay and multiplying the result by \u003cstrong\u003e6\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSwemed’s newer catalogue describes an updated LDH offering with \u003cstrong\u003ehigh linearity up to 1200 IU\/L\u003c\/strong\u003e and working-reagent stability up to 30 days. Because assay configuration may vary by production version, the \u003cstrong\u003ecurrent kit label and current package insert supplied with the 25 ml pack should be treated as the controlling specification\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManufacturer Reference Range\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecimen\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Reference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerum\u003c\/td\u003e\n\u003ctd\u003e230–460 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSwemed recommends that each laboratory establish or verify its own reference interval for its patient population. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy LDH Testing Is Performed\u003c\/h1\u003e\n\u003cp\u003eLactate Dehydrogenase is present in many tissues, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLiver\u003c\/li\u003e\n\u003cli\u003eHeart\u003c\/li\u003e\n\u003cli\u003eSkeletal muscle\u003c\/li\u003e\n\u003cli\u003eKidney\u003c\/li\u003e\n\u003cli\u003eRed blood cells\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLDH may become elevated in several conditions involving tissue damage or cell turnover. The manufacturer literature mentions associations with myocardial injury, pulmonary disease, hepatic disease, haemolytic anaemia, renal disease and muscular dystrophy. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eLDH testing may therefore form part of laboratory evaluation related to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTissue injury\u003c\/li\u003e\n\u003cli\u003eLiver-related investigations\u003c\/li\u003e\n\u003cli\u003eMuscle injury\u003c\/li\u003e\n\u003cli\u003eHaemolysis-related assessment\u003c\/li\u003e\n\u003cli\u003eRenal disease\u003c\/li\u003e\n\u003cli\u003eSelected cardiac investigations\u003c\/li\u003e\n\u003cli\u003eGeneral enzyme-profile testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLDH is \u003cstrong\u003enot tissue-specific\u003c\/strong\u003e, so results should always be interpreted with other laboratory and clinical findings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eLDH in a Clinical Chemistry Profile\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eRelated Test\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLaboratory Relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLDH\u003c\/td\u003e\n\u003ctd\u003eGeneral tissue enzyme \/ tissue injury marker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAST \/ SGOT\u003c\/td\u003e\n\u003ctd\u003eLiver and muscle enzyme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eALT \/ SGPT\u003c\/td\u003e\n\u003ctd\u003eLiver-associated enzyme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCK-NAC\u003c\/td\u003e\n\u003ctd\u003eMuscle enzyme assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCK-MB\u003c\/td\u003e\n\u003ctd\u003eCardiac-associated CK fraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBilirubin\u003c\/td\u003e\n\u003ctd\u003eLiver \/ haemolysis-related assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCreatinine\u003c\/td\u003e\n\u003ctd\u003eRenal profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUrea\u003c\/td\u003e\n\u003ctd\u003eRenal profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eStorage and Stability\u003c\/h1\u003e\n\u003cp\u003eStore the LDH reagents:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e2–8°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTightly closed\u003c\/li\u003e\n\u003cli\u003eProtected from light\u003c\/li\u003e\n\u003cli\u003eProtected from contamination\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDo not freeze\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe reagents should be brought to the required working temperature before testing and should not be used beyond the labelled expiry date. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSafety and Handling\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer notes that the reagents contain \u003cstrong\u003esodium azide\u003c\/strong\u003e, which requires appropriate laboratory handling.\u003c\/p\u003e\n\u003cp\u003eLaboratory personnel should:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWear suitable gloves\u003c\/li\u003e\n\u003cli\u003eUse eye \/ face protection\u003c\/li\u003e\n\u003cli\u003eAvoid ingestion or inhalation\u003c\/li\u003e\n\u003cli\u003eAvoid direct skin and mucous-membrane contact\u003c\/li\u003e\n\u003cli\u003eFollow current Good Laboratory Practice\u003c\/li\u003e\n\u003cli\u003eDispose of reagents according to institutional and applicable safety procedures \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eWho Can Buy This Product?\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine LDH testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry enzyme testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eInpatient and outpatient biochemical testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCardiac Laboratories\u003c\/td\u003e\n\u003ctd\u003eSelected enzyme-profile testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiver \/ Gastroenterology Centres\u003c\/td\u003e\n\u003ctd\u003eHepatic enzyme assessment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine LDH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and teaching laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eInstitutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional supply where permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eUseful Tips Before Ordering\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the required method is \u003cstrong\u003eLDH Modified IFCC \/ DGKC kinetic\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify the \u003cstrong\u003e25 ml pack size\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm analyser support for \u003cstrong\u003e340 nm kinetic measurement\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCheck that the analyser can maintain \u003cstrong\u003e37°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify the required sample volume and factor.\u003c\/li\u003e\n\u003cli\u003eEnsure the specimen type is serum or heparin plasma.\u003c\/li\u003e\n\u003cli\u003eDo not use EDTA or citrate plasma for this method.\u003c\/li\u003e\n\u003cli\u003eAvoid haemolysed samples.\u003c\/li\u003e\n\u003cli\u003eConfirm current reagent storage requirements.\u003c\/li\u003e\n\u003cli\u003eFollow the current package insert supplied with the kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eBuy Swemed LDH Reagent in Bangalore\u003c\/h1\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003eclinical chemistry, cardiac, liver and biochemistry reagents from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e to pathology laboratories, diagnostic centres, hospitals and institutional healthcare buyers.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit 25 ml\u003c\/strong\u003e can be ordered through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e, subject to stock availability and delivery serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSearch Relevance\u003c\/h1\u003e\n\u003cp\u003eThis product is relevant for buyers searching for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLDH reagent supplier in Bangalore\u003c\/li\u003e\n\u003cli\u003eSwemed LDH Reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eLDH reagent kit 25 ml\u003c\/li\u003e\n\u003cli\u003eLactate Dehydrogenase reagent Bengaluru\u003c\/li\u003e\n\u003cli\u003eLDH kinetic reagent India\u003c\/li\u003e\n\u003cli\u003eLDH IFCC reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eDGKC LDH reagent Karnataka\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier near me\u003c\/li\u003e\n\u003cli\u003ePathology lab reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eCardiac biochemistry reagent supplier India\u003c\/li\u003e\n\u003cli\u003eBuy LDH reagent online India\u003c\/li\u003e\n\u003cli\u003eSwemed Diagnostics reagent supplier India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct Summary\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed LDH Reagent Kit 25 ml?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed LDH Reagent Kit 25 ml\u003c\/strong\u003e is a professional clinical biochemistry reagent used for quantitative measurement of Lactate Dehydrogenase activity by a kinetic UV method.\u003c\/p\u003e\n\u003ch3\u003eWhat method does it use?\u003c\/h3\u003e\n\u003cp\u003eThe current Swemed product literature identifies the assay as a \u003cstrong\u003eModified IFCC kinetic method\u003c\/strong\u003e, while the newer Swemed catalogue describes LDH as an \u003cstrong\u003eOptimized DGKC pyruvate-to-lactate method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay is measured at \u003cstrong\u003e340 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat specimen is suitable?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer lists \u003cstrong\u003eserum and heparin plasma\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan EDTA plasma be used?\u003c\/h3\u003e\n\u003cp\u003eNo. Swemed states that \u003cstrong\u003eEDTA and sodium citrate may inhibit the assay\u003c\/strong\u003e and should not be used. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe macro procedure uses \u003cstrong\u003e25 µl sample\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay factor?\u003c\/h3\u003e\n\u003cp\u003eThe stated calculation factor is \u003cstrong\u003e8199\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the stated linearity?\u003c\/h3\u003e\n\u003cp\u003eThe current product insert states \u003cstrong\u003e1000 U\/L\u003c\/strong\u003e. The latest Swemed catalogue mentions an updated LDH formulation with linearity up to \u003cstrong\u003e1200 IU\/L\u003c\/strong\u003e, so laboratories should follow the specification on the current supplied kit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhere can Swemed LDH reagent be purchased?\u003c\/h3\u003e\n\u003cp\u003eIt can be purchased from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to stock availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eEntity Information\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eLDH Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e25 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyte\u003c\/td\u003e\n\u003ctd\u003eLactate Dehydrogenase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eModified IFCC \/ Optimized DGKC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction\u003c\/td\u003e\n\u003ctd\u003ePyruvate to Lactate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Type\u003c\/td\u003e\n\u003ctd\u003eUV Kinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum \/ Heparin Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eCardiac \/ Clinical Chemistry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuyer Type\u003c\/td\u003e\n\u003ctd\u003eLaboratory \/ Hospital \/ Diagnostic Centre \/ B2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eWhy Buy Swemed LDH Reagent from Microsidd.com?\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eLDH and other enzyme reagents require careful procurement because laboratories must verify the \u003cstrong\u003ecorrect method, wavelength, reagent configuration, pack size, storage requirements, analyser compatibility and seller source\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eMicrosidd India has been involved in the \u003cstrong\u003eIVD and diagnostic-product sector since 2000\u003c\/strong\u003e and specialises in laboratory, diagnostic and healthcare products. Professional buyers therefore deal with an identifiable specialist seller rather than relying only on an unrelated third-party marketplace listing.\u003c\/p\u003e\n\u003ch2\u003eMicrosidd.com vs Online Marketplaces vs Offline Suppliers\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLarge Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline \/ Local Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Specialisation\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and laboratory focused\u003c\/td\u003e\n\u003ctd\u003eSeller expertise varies\u003c\/td\u003e\n\u003ctd\u003eDepends on individual dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Knowledge\u003c\/td\u003e\n\u003ctd\u003eBetter suited to reagent-specific enquiries\u003c\/td\u003e\n\u003ctd\u003eOften general marketplace support\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Identity\u003c\/td\u003e\n\u003ctd\u003eDirect purchase from Microsidd India\u003c\/td\u003e\n\u003ctd\u003eMarketplace and seller may differ\u003c\/td\u003e\n\u003ctd\u003eUsually identifiable locally\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod Verification\u003c\/td\u003e\n\u003ctd\u003eLDH method and pack can be checked before order\u003c\/td\u003e\n\u003ctd\u003eSimilar listings may cause confusion\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier knowledge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for laboratories and institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eOften local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSpecialist diagnostic and laboratory catalogue\u003c\/td\u003e\n\u003ctd\u003eBroad but not specialised\u003c\/td\u003e\n\u003ctd\u003eUsually limited by local inventory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect Microsidd assistance\u003c\/td\u003e\n\u003ctd\u003eMarketplace plus seller layer\u003c\/td\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccountability\u003c\/td\u003e\n\u003ctd\u003eOne identifiable specialist supplier\u003c\/td\u003e\n\u003ctd\u003eSeller may vary by listing\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Access\u003c\/td\u003e\n\u003ctd\u003eSubject to serviceability\u003c\/td\u003e\n\u003ctd\u003eBroad\u003c\/td\u003e\n\u003ctd\u003eUsually regional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eBenefits of Buying from Microsidd.com\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd Advantage\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBenefit to Laboratory Buyers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Product Specialisation\u003c\/td\u003e\n\u003ctd\u003eBetter suited to professional laboratory procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIVD Experience Since 2000\u003c\/td\u003e\n\u003ctd\u003eLong-standing diagnostic-sector experience\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Seller Accountability\u003c\/td\u003e\n\u003ctd\u003ePurchase directly from Microsidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eUseful for laboratories and institutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification Support\u003c\/td\u003e\n\u003ctd\u003eMethod, pack and compatibility can be checked before purchase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Category Procurement\u003c\/td\u003e\n\u003ctd\u003eCardiac, liver, renal and other reagents can be sourced together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBangalore-Based Operations\u003c\/td\u003e\n\u003ctd\u003eConvenient for Bengaluru and Karnataka laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eDelivery to serviceable locations across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Customer Support\u003c\/td\u003e\n\u003ctd\u003eProduct and order-related queries handled directly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed LDH Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is intended for quantitative determination of \u003cstrong\u003eLactate Dehydrogenase activity\u003c\/strong\u003e in professional clinical chemistry laboratories.\u003c\/p\u003e\n\u003ch3\u003eWhat is the pack size?\u003c\/h3\u003e\n\u003cp\u003eThe pack size is \u003cstrong\u003e25 ml\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method is used?\u003c\/h3\u003e\n\u003cp\u003eThe official product insert states \u003cstrong\u003eModified IFCC Method\u003c\/strong\u003e, while Swemed’s newer catalogue describes an \u003cstrong\u003eOptimized DGKC pyruvate-to-lactate method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e340 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat specimen is suitable?\u003c\/h3\u003e\n\u003cp\u003eSwemed lists \u003cstrong\u003eserum and heparin plasma\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan EDTA or citrate plasma be used?\u003c\/h3\u003e\n\u003cp\u003eNo. The manufacturer states that EDTA and sodium citrate may inhibit the assay. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe macro procedure uses \u003cstrong\u003e25 µl sample\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow is the working reagent prepared?\u003c\/h3\u003e\n\u003cp\u003eMix \u003cstrong\u003e4 parts R1 with 1 part R2\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow long is the working reagent stable?\u003c\/h3\u003e\n\u003cp\u003eThe current product insert states \u003cstrong\u003e1 week at 2–8°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay factor?\u003c\/h3\u003e\n\u003cp\u003eThe calculation factor is \u003cstrong\u003e8199\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay linearity?\u003c\/h3\u003e\n\u003cp\u003eThe current insert states \u003cstrong\u003e1000 U\/L\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs this suitable for home testing?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on any biochemistry analyser?\u003c\/h3\u003e\n\u003cp\u003eThe laboratory should verify \u003cstrong\u003e340 nm capability, kinetic programming, reaction temperature, sample volume and validated application\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Swemed LDH Reagent in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eThe product can be ordered from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to stock availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMedical and Laboratory Disclaimer\u003c\/h1\u003e\n\u003cp\u003eThe information on this product page is provided for \u003cstrong\u003egeneral product identification, procurement and educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eLDH is a non-specific tissue enzyme and an elevated or reduced result must not be used independently to diagnose or exclude any particular disease. Interpretation should consider patient history, clinical findings and other relevant laboratory investigations.\u003c\/p\u003e\n\u003cp\u003eThe information provided by Microsidd India does not replace the official Swemed Diagnostics package insert, analyser instructions, laboratory standard operating procedures, calibration requirements, quality-control procedures or professional medical judgement.\u003c\/p\u003e\n\u003cp\u003eBecause Swemed’s current insert and newer catalogue show slightly different performance claims for LDH linearity and working stability, the \u003cstrong\u003ecurrent package insert supplied with the actual kit should always be followed as the definitive specification\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eNo Return \/ No Exchange Policy\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Swemed Diagnostics","offers":[{"title":"Default Title","offer_id":53143416996160,"sku":"LDH 25ml","price":850.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/Swemed_LDH_Reagent_Kit_25ml_Modified_IFCC_Kinetic_Method_Microsidd.png?v=1789139855","url":"https:\/\/microsidd.com\/products\/ldh-reagent-kit-25-ml-modified-ifcc-optimized-dgkc-kinetic-method","provider":"Microsidd India","version":"1.0","type":"link"}