{"product_id":"hdl-cholesterol-direct-reagent-kit","title":"HDL Cholesterol Direct Enzymatic Liquid Reagent Kit 100ml","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed HDL Cholesterol Direct Enzymatic Liquid Reagent Kit 100ml\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed HDL Cholesterol Reagent Kit\u003c\/strong\u003e is a professional \u003cstrong\u003edirect enzymatic liquid biochemistry reagent\u003c\/strong\u003e intended for the quantitative determination of \u003cstrong\u003eHDL Cholesterol (HDL-C)\u003c\/strong\u003e in serum and plasma.\u003c\/p\u003e\n\u003cp\u003eThe assay uses a \u003cstrong\u003etwo-reagent direct enzymatic method\u003c\/strong\u003e designed to selectively measure HDL cholesterol without requiring a separate precipitation step. It is intended for use in pathology laboratories, diagnostic centres, hospitals and clinical biochemistry laboratories performing routine lipid profile testing. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHDL cholesterol is an important component of lipid-profile assessment. High-density lipoproteins participate in cholesterol transport, and HDL-C measurement is commonly used together with total cholesterol, triglycerides and LDL cholesterol in cardiovascular-risk evaluation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct at a Glance\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eHDL Cholesterol Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Type\u003c\/td\u003e\n\u003ctd\u003eDirect Enzymatic Liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eHDL Cholesterol \/ HDL-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Format\u003c\/td\u003e\n\u003ctd\u003eTwo-Reagent System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Type\u003c\/td\u003e\n\u003ctd\u003eDirect Enzymatic \/ Photometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Mode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum, EDTA Plasma, Heparin Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e630 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Temperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Incubation\u003c\/td\u003e\n\u003ctd\u003e10 minutes at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1 Volume\u003c\/td\u003e\n\u003ctd\u003e800 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 2 Volume\u003c\/td\u003e\n\u003ctd\u003e200 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eUp to 180 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Preparation\u003c\/td\u003e\n\u003ctd\u003eReady to Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrator\u003c\/td\u003e\n\u003ctd\u003eLyophilized Human Serum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eProfessional In Vitro Diagnostic Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru, Karnataka, India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKit Components\u003c\/h1\u003e\n\u003cp\u003eThe Swemed Direct HDL Cholesterol system consists of:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1\u003c\/td\u003e\n\u003ctd\u003eEnzyme Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 2\u003c\/td\u003e\n\u003ctd\u003eDeveloper Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrator\u003c\/td\u003e\n\u003ctd\u003eLyophilized Human Serum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe reagents are supplied \u003cstrong\u003eready to use\u003c\/strong\u003e. The calibrator is reconstituted with the exact volume of deionized water stated on its label, mixed thoroughly and allowed to stand at room temperature for approximately 30 minutes before use. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics HDL Cholesterol Reagent\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDirect enzymatic liquid method\u003c\/li\u003e\n\u003cli\u003eDesigned for quantitative \u003cstrong\u003eHDL-C determination\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo-reagent assay format\u003c\/li\u003e\n\u003cli\u003eNo separate precipitation step required\u003c\/li\u003e\n\u003cli\u003eSuitable for serum and plasma\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003eserum, EDTA plasma and heparin plasma\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReagents supplied \u003cstrong\u003eready to use\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEndpoint measurement\u003c\/li\u003e\n\u003cli\u003eWavelength: \u003cstrong\u003e630 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample requirement: \u003cstrong\u003e10 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLinearity up to \u003cstrong\u003e180 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for routine lipid-profile testing\u003c\/li\u003e\n\u003cli\u003eProfessional \u003cstrong\u003ein vitro diagnostic use only\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for pathology labs, hospitals and diagnostic centres \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Benefits\u003c\/h1\u003e\n\u003ch2\u003eDirect HDL Cholesterol Measurement\u003c\/h2\u003e\n\u003cp\u003eThe assay uses selective detergent chemistry and enzymatic reactions to enable \u003cstrong\u003edirect determination of HDL cholesterol\u003c\/strong\u003e without a manual lipoprotein precipitation procedure. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReady-to-Use Reagents\u003c\/h2\u003e\n\u003cp\u003eReagent 1 and Reagent 2 are supplied ready for laboratory use, helping simplify routine HDL testing workflows. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eLow Sample Volume\u003c\/h2\u003e\n\u003cp\u003eThe assay uses only \u003cstrong\u003e10 µl of sample\u003c\/strong\u003e, making it suitable for routine clinical chemistry workflows where efficient specimen utilisation is important. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSuitable for Routine Lipid Profiles\u003c\/h2\u003e\n\u003cp\u003eHDL-C is commonly measured together with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Cholesterol\u003c\/li\u003e\n\u003cli\u003eTriglycerides\u003c\/li\u003e\n\u003cli\u003eLDL Cholesterol\u003c\/li\u003e\n\u003cli\u003eVLDL calculations or related lipid parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes the reagent highly relevant for laboratories performing routine lipid-profile investigations.\u003c\/p\u003e\n\u003ch2\u003eBroad Laboratory Application\u003c\/h2\u003e\n\u003cp\u003eSuitable for pathology laboratories, hospital laboratories, diagnostic centres and other professional clinical chemistry facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eIntended Use\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed HDL Cholesterol Direct Enzymatic Liquid Reagent\u003c\/strong\u003e is intended for quantitative determination of \u003cstrong\u003eHDL cholesterol in serum and plasma\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe product is intended for use by trained laboratory professionals and for \u003cstrong\u003ein vitro diagnostic use only\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTest Principle\u003c\/h1\u003e\n\u003cp\u003eThe method uses a \u003cstrong\u003etwo-reagent system\u003c\/strong\u003e based on selective detergent and enzymatic reactions.\u003c\/p\u003e\n\u003cp\u003eIn the first reagent, non-HDL unesterified cholesterol undergoes an enzyme reaction. The hydrogen peroxide produced during this stage is consumed through a peroxidase reaction, yielding a colourless product.\u003c\/p\u003e\n\u003cp\u003eThe second reagent contains a detergent that selectively solubilizes HDL, together with cholesterol esterase and a chromogenic coupler. This produces a coloured reaction proportional to the HDL cholesterol concentration present in the specimen. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTest Parameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eHDL Cholesterol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eDirect Enzymatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Format\u003c\/td\u003e\n\u003ctd\u003eTwo Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e630 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Temperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Direction\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 1 Volume\u003c\/td\u003e\n\u003ctd\u003e800 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent 2 Volume\u003c\/td\u003e\n\u003ctd\u003e200 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay\u003c\/td\u003e\n\u003ctd\u003e5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Incubation\u003c\/td\u003e\n\u003ctd\u003e10 minutes at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e180 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManual Assay Procedure\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eAddition\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBlank\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eCalibrator\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTest\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHDL Reagent 1\u003c\/td\u003e\n\u003ctd\u003e800 µl\u003c\/td\u003e\n\u003ctd\u003e800 µl\u003c\/td\u003e\n\u003ctd\u003e800 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHDL Reagent 2\u003c\/td\u003e\n\u003ctd\u003e200 µl\u003c\/td\u003e\n\u003ctd\u003e200 µl\u003c\/td\u003e\n\u003ctd\u003e200 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrator\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eMix and incubate for \u003cstrong\u003e10 minutes at room temperature\u003c\/strong\u003e, then measure the absorbance of the sample and calibrator against the reagent blank at \u003cstrong\u003e630 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Requirements\u003c\/h1\u003e\n\u003cp\u003eSuitable specimens include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFresh serum\u003c\/li\u003e\n\u003cli\u003eEDTA plasma\u003c\/li\u003e\n\u003cli\u003eHeparinized plasma\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFresh serum is recommended. Serum should be removed from the blood clot as soon as possible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCitrate-containing anticoagulants should not be used.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Stability\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer states that samples are stable for approximately:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eStorage Condition\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2–8°C\u003c\/td\u003e\n\u003ctd\u003e7 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMeasuring Range and Linearity\u003c\/h1\u003e\n\u003cp\u003eThe Swemed Direct HDL Cholesterol method is linear up to \u003cstrong\u003e180 mg\/dL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSamples with concentrations above this limit may be diluted \u003cstrong\u003e1:1\u003c\/strong\u003e, with the resulting value multiplied by 2 according to the manufacturer procedure. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eReagent Storage and Stability\u003c\/h1\u003e\n\u003cp\u003eStore the HDL Cholesterol reagents at:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2–8°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen stored correctly, the reagents remain stable until the expiration date stated on the reagent bottle and kit-box label. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy HDL Cholesterol Testing Is Important\u003c\/h1\u003e\n\u003cp\u003eHDL cholesterol is one of the major lipoprotein-related parameters used in clinical lipid assessment.\u003c\/p\u003e\n\u003cp\u003eHDL particles participate in the transport of cholesterol in the bloodstream. HDL-C measurement is commonly used as part of cardiovascular risk assessment and lipid-profile interpretation. The Swemed insert describes HDL cholesterol measurement as a useful predictor in coronary heart disease evaluation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHDL-C testing may therefore form part of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoutine lipid profiles\u003c\/li\u003e\n\u003cli\u003eCardiovascular-risk assessment\u003c\/li\u003e\n\u003cli\u003eDyslipidaemia investigation\u003c\/li\u003e\n\u003cli\u003eMetabolic-health evaluation\u003c\/li\u003e\n\u003cli\u003eDiabetes-related lipid monitoring\u003c\/li\u003e\n\u003cli\u003ePreventive health screening\u003c\/li\u003e\n\u003cli\u003eFollow-up of lipid-management programmes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndividual results should always be interpreted by qualified healthcare professionals in conjunction with other lipid parameters and the patient's clinical information.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHDL Cholesterol in a Lipid Profile\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLaboratory Relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cholesterol\u003c\/td\u003e\n\u003ctd\u003eMeasures overall circulating cholesterol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHDL Cholesterol\u003c\/td\u003e\n\u003ctd\u003eMeasures cholesterol associated with high-density lipoproteins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLDL Cholesterol\u003c\/td\u003e\n\u003ctd\u003eCommonly used in atherogenic-risk evaluation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTriglycerides\u003c\/td\u003e\n\u003ctd\u003eMeasures circulating triglyceride concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLDL\u003c\/td\u003e\n\u003ctd\u003eOften estimated as part of lipid-profile interpretation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eWho Can Buy This Product?\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine HDL-C and lipid-profile testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eCardiovascular and metabolic investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry and lipid testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinics with Laboratory Facilities\u003c\/td\u003e\n\u003ctd\u003eRoutine biochemical screening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreventive Health Centres\u003c\/td\u003e\n\u003ctd\u003eLipid-profile investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eLaboratory and teaching applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eProfessional diagnostic procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional supply where permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine HDL cholesterol testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eUseful Tips Before Ordering\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that \u003cstrong\u003eDirect HDL Cholesterol\u003c\/strong\u003e is the required test parameter.\u003c\/li\u003e\n\u003cli\u003eConfirm compatibility with your biochemistry analyser.\u003c\/li\u003e\n\u003cli\u003eVerify the required \u003cstrong\u003e630 nm wavelength\u003c\/strong\u003e capability.\u003c\/li\u003e\n\u003cli\u003eConfirm that the laboratory workflow supports a two-reagent HDL assay.\u003c\/li\u003e\n\u003cli\u003eEnsure the required calibrator is supplied or available.\u003c\/li\u003e\n\u003cli\u003eVerify storage facilities at \u003cstrong\u003e2–8°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eUse fresh serum or approved plasma specimens.\u003c\/li\u003e\n\u003cli\u003eDo not use citrate plasma.\u003c\/li\u003e\n\u003cli\u003eFollow the current Swemed assay instructions.\u003c\/li\u003e\n\u003cli\u003eMaintain routine calibration and internal quality control.\u003c\/li\u003e\n\u003cli\u003eDo not use reagent after the stated expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eBuy Swemed HDL Cholesterol Reagent in Bangalore\u003c\/h1\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003ebiochemistry reagents, lipid-profile reagents and clinical laboratory products from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Swemed HDL Cholesterol Direct Enzymatic reagent is suitable for procurement by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePathology laboratories in Bangalore\u003c\/li\u003e\n\u003cli\u003eDiagnostic centres in Bengaluru\u003c\/li\u003e\n\u003cli\u003eHospital laboratories\u003c\/li\u003e\n\u003cli\u003ePreventive health centres\u003c\/li\u003e\n\u003cli\u003eClinical chemistry laboratories\u003c\/li\u003e\n\u003cli\u003eMedical institutions\u003c\/li\u003e\n\u003cli\u003eProfessional healthcare buyers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCustomers outside Bangalore can also order laboratory products through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e for delivery to serviceable locations across India.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eLocal Search Relevance\u003c\/h1\u003e\n\u003cp\u003eThis product is relevant for buyers searching for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHDL cholesterol reagent supplier in Bangalore\u003c\/li\u003e\n\u003cli\u003eDirect HDL reagent Bengaluru\u003c\/li\u003e\n\u003cli\u003eSwemed HDL Cholesterol Reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eHDL reagent kit India\u003c\/li\u003e\n\u003cli\u003eHDL direct enzymatic reagent supplier\u003c\/li\u003e\n\u003cli\u003eLipid profile reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier Bengaluru\u003c\/li\u003e\n\u003cli\u003eBiochemistry reagent supplier Karnataka\u003c\/li\u003e\n\u003cli\u003ePathology lab reagent supplier near me\u003c\/li\u003e\n\u003cli\u003eHDL cholesterol test reagent online India\u003c\/li\u003e\n\u003cli\u003eSwemed Diagnostics reagent supplier India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct Summary\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed HDL Cholesterol Reagent?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed HDL Cholesterol Direct Enzymatic Liquid Reagent\u003c\/strong\u003e is a professional two-reagent clinical biochemistry assay for quantitative determination of HDL cholesterol in serum and plasma. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat method does it use?\u003c\/h3\u003e\n\u003cp\u003eIt uses a \u003cstrong\u003edirect enzymatic two-reagent method\u003c\/strong\u003e involving selective detergent chemistry to measure HDL cholesterol without a separate precipitation step. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich specimens can be used?\u003c\/h3\u003e\n\u003cp\u003eFresh serum, EDTA plasma and heparinized plasma are acceptable. Citrate-containing anticoagulants should not be used. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer specifies \u003cstrong\u003e630 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e10 µl of sample\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003eThe stated linearity is \u003cstrong\u003e180 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAre the reagents ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. Swemed states that the reagents are supplied \u003cstrong\u003eready to use\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhere can Swemed HDL Cholesterol reagent be purchased?\u003c\/h3\u003e\n\u003cp\u003eIt can be ordered from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to stock availability and delivery serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eGEO and Entity Information\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eHDL Cholesterol Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eDirect Enzymatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Format\u003c\/td\u003e\n\u003ctd\u003eTwo-Reagent Liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyte\u003c\/td\u003e\n\u003ctd\u003eHDL Cholesterol \/ HDL-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum \/ EDTA Plasma \/ Heparin Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubcategory\u003c\/td\u003e\n\u003ctd\u003eBiochemistry Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eLipid Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuyer Type\u003c\/td\u003e\n\u003ctd\u003eLaboratory \/ Healthcare \/ B2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eWhy Buy Swemed HDL Cholesterol Reagent from Microsidd.com?\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eLaboratory reagents require more careful procurement than ordinary consumer products. Buyers should verify the \u003cstrong\u003ecorrect analyte, method, reagent configuration, analyser compatibility, storage requirements, product source, expiry and seller accountability\u003c\/strong\u003e before placing an order.\u003c\/p\u003e\n\u003cp\u003eMicrosidd India has been associated with \u003cstrong\u003eIVD and diagnostic-product supply since 2000\u003c\/strong\u003e and focuses on diagnostic, laboratory and healthcare products. This specialist background makes microsidd.com suitable for laboratories that prefer purchasing from an identifiable diagnostic supplier rather than an unrelated marketplace seller.\u003c\/p\u003e\n\u003cp\u003eMicrosidd also maintains established and authorised manufacturer relationships across multiple diagnostic-product categories, providing professional buyers with a dependable procurement channel for recurring laboratory requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMicrosidd.com vs Online Marketplaces vs Offline Suppliers\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLarge Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline \/ Local Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Specialisation\u003c\/td\u003e\n\u003ctd\u003eDiagnostic, laboratory and healthcare focused\u003c\/td\u003e\n\u003ctd\u003eExpertise varies by seller\u003c\/td\u003e\n\u003ctd\u003eDepends on dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Product Knowledge\u003c\/td\u003e\n\u003ctd\u003eProduct-focused support\u003c\/td\u003e\n\u003ctd\u003eOften general marketplace support\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Identity\u003c\/td\u003e\n\u003ctd\u003eDirect purchase from Microsidd India\u003c\/td\u003e\n\u003ctd\u003eMarketplace and actual seller may differ\u003c\/td\u003e\n\u003ctd\u003eUsually identifiable locally\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Relationships\u003c\/td\u003e\n\u003ctd\u003eEstablished diagnostic manufacturer relationships across multiple categories\u003c\/td\u003e\n\u003ctd\u003eDepends on seller\u003c\/td\u003e\n\u003ctd\u003eVaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification\u003c\/td\u003e\n\u003ctd\u003eMethod, analyte and specifications can be checked before ordering\u003c\/td\u003e\n\u003ctd\u003eSimilar listings may cause confusion\u003c\/td\u003e\n\u003ctd\u003eDepends on available stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for laboratories and institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eCommonly local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSpecialist diagnostic and laboratory catalogue\u003c\/td\u003e\n\u003ctd\u003eBroad but not specialised\u003c\/td\u003e\n\u003ctd\u003eUsually limited by local inventory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect Microsidd support\u003c\/td\u003e\n\u003ctd\u003eMarketplace plus seller layer\u003c\/td\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccountability\u003c\/td\u003e\n\u003ctd\u003eOne identifiable specialist supplier\u003c\/td\u003e\n\u003ctd\u003eSellers may vary\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnline Convenience\u003c\/td\u003e\n\u003ctd\u003eDirect ordering through microsidd.com\u003c\/td\u003e\n\u003ctd\u003eConvenient\u003c\/td\u003e\n\u003ctd\u003eMay require store visit or phone ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeographic Reach\u003c\/td\u003e\n\u003ctd\u003eIndia-wide subject to serviceability\u003c\/td\u003e\n\u003ctd\u003eBroad\u003c\/td\u003e\n\u003ctd\u003eTypically local or regional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eBenefits of Buying from Microsidd.com\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd Advantage\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBenefit to Laboratory Buyers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecialist Diagnostic Supplier\u003c\/td\u003e\n\u003ctd\u003eBetter alignment with professional laboratory requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIVD Experience Since 2000\u003c\/td\u003e\n\u003ctd\u003eLong-standing diagnostic-product experience\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Relationships\u003c\/td\u003e\n\u003ctd\u003eEstablished and authorised relationships across diagnostic categories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Seller Accountability\u003c\/td\u003e\n\u003ctd\u003ePurchase directly from Microsidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eSuitable for professional and institutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification Support\u003c\/td\u003e\n\u003ctd\u003eBuyers can confirm specifications before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Category Procurement\u003c\/td\u003e\n\u003ctd\u003eReagents, diagnostic kits and consumables available together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBangalore-Based Operations\u003c\/td\u003e\n\u003ctd\u003eConvenient for Bengaluru and Karnataka laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eUseful for laboratories outside Bangalore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Customer Support\u003c\/td\u003e\n\u003ctd\u003eProduct and order queries handled by Microsidd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed HDL Cholesterol Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is intended for quantitative determination of \u003cstrong\u003eHDL cholesterol in serum and plasma\u003c\/strong\u003e using a direct enzymatic method. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs this a direct HDL assay?\u003c\/h3\u003e\n\u003cp\u003eYes. The Swemed product uses a \u003cstrong\u003edirect enzymatic two-reagent method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich specimens are acceptable?\u003c\/h3\u003e\n\u003cp\u003eFresh serum, EDTA plasma and heparinized plasma are acceptable. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCan citrate plasma be used?\u003c\/h3\u003e\n\u003cp\u003eNo. The manufacturer states that anticoagulants containing citrate should not be used. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength does the assay require?\u003c\/h3\u003e\n\u003cp\u003eThe assay is measured at \u003cstrong\u003e630 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer specifies \u003cstrong\u003e10 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow much reagent is used?\u003c\/h3\u003e\n\u003cp\u003eThe specified automated parameters are \u003cstrong\u003e800 µl Reagent 1 and 200 µl Reagent 2\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay linearity?\u003c\/h3\u003e\n\u003cp\u003eThe method is linear up to \u003cstrong\u003e180 mg\/dL\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAre the reagents ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. The reagents are supplied ready to use. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eDoes the calibrator need preparation?\u003c\/h3\u003e\n\u003cp\u003eYes. The lyophilized calibrator should be reconstituted using the exact volume of deionized water specified on its label and allowed to stand at room temperature for approximately 30 minutes. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow should the reagent be stored?\u003c\/h3\u003e\n\u003cp\u003eStore at \u003cstrong\u003e2–8°C\u003c\/strong\u003e according to the manufacturer instructions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow long is the sample stable?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer states sample stability of \u003cstrong\u003e7 days at 2–8°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs the product intended for home testing?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan it be used on any biochemistry analyser?\u003c\/h3\u003e\n\u003cp\u003eThe laboratory should verify analyser compatibility, wavelength, reagent programming and validated application before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Swemed HDL Cholesterol reagent in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eThe product can be ordered from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to availability.\u003c\/p\u003e\n\u003ch3\u003eCan laboratories outside Bangalore buy from Microsidd.com?\u003c\/h3\u003e\n\u003cp\u003eYes. Microsidd supplies diagnostic and laboratory products to serviceable locations across India.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMedical and Laboratory Disclaimer\u003c\/h1\u003e\n\u003cp\u003eThe information on this product page is provided for \u003cstrong\u003egeneral product identification, procurement and educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe information provided by Microsidd India does not replace the official Swemed Diagnostics product insert, analyser instructions, laboratory standard operating procedures, calibration requirements, quality-control procedures or professional medical judgement.\u003c\/p\u003e\n\u003cp\u003eSpecimen requirements, methodology, reagent preparation, analyser settings, calibration, reference intervals, storage, stability, quality-control requirements and interpretation should always follow the current manufacturer instructions.\u003c\/p\u003e\n\u003cp\u003eLaboratory results must be interpreted by qualified healthcare professionals together with the patient's clinical information and other relevant investigations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eNo Return \/ No Exchange Policy\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Swemed Diagnostics","offers":[{"title":"Default Title","offer_id":53143051370816,"sku":"HDLC 100ml","price":1200.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/HDLCholesterolDirectEnzymaticLiquidReagentKit100ml4.png?v=1789124438","url":"https:\/\/microsidd.com\/products\/hdl-cholesterol-direct-reagent-kit","provider":"Microsidd India","version":"1.0","type":"link"}