{"product_id":"glucose-liquid-stable-reagent-500-ml-1000-ml","title":"Glucose Liquid Stable Reagent | GOD-POD Method | 500 ml \u0026 1000 ml Variants","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed Glucose Liquid Stable Reagent\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Glucose Liquid Stable Reagent\u003c\/strong\u003e is a professional \u003cstrong\u003eclinical biochemistry reagent\u003c\/strong\u003e intended for the \u003cstrong\u003ephotometric determination of glucose\u003c\/strong\u003e using the \u003cstrong\u003eGOD-POD method\u003c\/strong\u003e. It is suitable for routine glucose testing in professional laboratory settings and is designed for \u003cstrong\u003ein vitro diagnostic use only\u003c\/strong\u003e. The manufacturer literature identifies the method as a photometric glucose assay for \u003cstrong\u003eserum and plasma\u003c\/strong\u003e samples and describes the reagent and standard as \u003cstrong\u003eready to use\u003c\/strong\u003e.【turn704895view0†L3-L7】【turn704895view0†L60-L67】\u003c\/p\u003e\n\u003cp\u003eSwemed lists Glucose under its clinical biochemistry range with \u003cstrong\u003eGOD-POD methodology\u003c\/strong\u003e, while the 2024 Swemed catalogue describes it as a \u003cstrong\u003eliquid stable ready-to-use mono reagent\u003c\/strong\u003e with a \u003cstrong\u003e100 mg\/dL standard\u003c\/strong\u003e and endpoint programming.【turn417549view0†L64-L67】【turn417549view1†L83-L87】\u003c\/p\u003e\n\u003cp\u003eThis product is suitable for use in \u003cstrong\u003epathology laboratories, diagnostic centres, hospital laboratories, clinics with laboratory facilities and professional clinical chemistry laboratories\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAvailable Variants\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eVariant\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTotal Reagent Volume\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwemed Glucose Liquid Stable Reagent\u003c\/td\u003e\n\u003ctd\u003e500 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwemed Glucose Liquid Stable Reagent\u003c\/td\u003e\n\u003ctd\u003e1000 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eGlucose Liquid Stable Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Variants\u003c\/td\u003e\n\u003ctd\u003e500 ml, 1000 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBiochemistry Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eGOD-POD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003ePhotometric \/ Enzymatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum, Heparin Plasma, EDTA Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e505 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Concentration\u003c\/td\u003e\n\u003ctd\u003e100 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Format\u003c\/td\u003e\n\u003ctd\u003eLiquid Stable Ready-to-Use Mono Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e10 minutes at 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eUp to 500 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eProfessional In Vitro Diagnostic Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru, Karnataka, India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe method, specimen types, wavelength, standard concentration, reagent format and linearity are based on the Swemed product literature and catalogue.【turn704895view0†L61-L67】【turn704895view0†L105-L155】【turn417549view1†L83-L87】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Glucose Liquid Stable Reagent\u003c\/strong\u003e is designed for professional laboratory estimation of glucose by the \u003cstrong\u003eGlucose Oxidase–Peroxidase (GOD-POD)\u003c\/strong\u003e method. In this assay, glucose is first oxidized to produce hydrogen peroxide, and the hydrogen peroxide then reacts with chromogenic components in the presence of peroxidase to form a coloured compound. The colour intensity is proportional to the glucose concentration in the sample.【turn704895view0†L19-L33】\u003c\/p\u003e\n\u003cp\u003eGlucose testing is one of the most frequently performed clinical chemistry investigations and is widely used in the evaluation and monitoring of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiabetes mellitus\u003c\/li\u003e\n\u003cli\u003eHyperglycaemia\u003c\/li\u003e\n\u003cli\u003eHypoglycaemia\u003c\/li\u003e\n\u003cli\u003eRoutine health screening\u003c\/li\u003e\n\u003cli\u003eMetabolic evaluation\u003c\/li\u003e\n\u003cli\u003eClinical biochemistry panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Swemed literature states that the reagent and standard are \u003cstrong\u003eready to use\u003c\/strong\u003e, which supports routine laboratory workflow and simplifies assay preparation.【turn704895view0†L60-L67】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics Glucose Liquid Stable Reagent\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAvailable in \u003cstrong\u003e500 ml and 1000 ml variants\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGOD-POD enzymatic method\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eLiquid stable ready-to-use mono reagent\u003c\/li\u003e\n\u003cli\u003eSuitable for professional glucose estimation\u003c\/li\u003e\n\u003cli\u003eIntended for photometric testing\u003c\/li\u003e\n\u003cli\u003eRecommended wavelength: \u003cstrong\u003e505 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupplied with \u003cstrong\u003e100 mg\/dL glucose standard\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEndpoint method\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003eserum, heparin plasma and EDTA plasma\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLinearity up to \u003cstrong\u003e500 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eConvenient for routine clinical chemistry laboratories\u003c\/li\u003e\n\u003cli\u003eIntended for \u003cstrong\u003ein vitro diagnostic use only\u003c\/strong\u003e【turn704895view0†L61-L67】【turn704895view0†L105-L155】【turn417549view1†L83-L87】\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003ch3\u003eReliable Enzymatic Glucose Measurement\u003c\/h3\u003e\n\u003cp\u003eThe GOD-POD method is a widely used enzymatic approach for glucose determination in clinical chemistry laboratories. Swemed’s assay follows this established principle for quantitative photometric estimation of glucose.【turn704895view0†L19-L33】\u003c\/p\u003e\n\u003ch3\u003eReady-to-Use Reagent\u003c\/h3\u003e\n\u003cp\u003eThe Swemed insert states that the reagent and standard are ready to use, helping laboratories reduce preparation steps and maintain workflow efficiency.【turn704895view0†L60-L67】\u003c\/p\u003e\n\u003ch3\u003eSuitable for Routine Testing\u003c\/h3\u003e\n\u003cp\u003eWith endpoint programming and a practical photometric method, the reagent is appropriate for routine professional glucose testing in pathology labs, hospitals and diagnostic centres.【turn704895view0†L105-L118】【turn417549view1†L83-L87】\u003c\/p\u003e\n\u003ch3\u003ePractical Variant Options\u003c\/h3\u003e\n\u003cp\u003eThe product is offered in \u003cstrong\u003e500 ml and 1000 ml variants\u003c\/strong\u003e, which helps laboratories choose the pack size most suitable for their workload and procurement cycle.\u003c\/p\u003e\n\u003ch3\u003eProfessional Laboratory Use\u003c\/h3\u003e\n\u003cp\u003eThe assay is intended for trained laboratory personnel and is suitable for use within quality-controlled clinical chemistry environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eIntended Use\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Glucose Liquid Stable Reagent\u003c\/strong\u003e is intended for the \u003cstrong\u003ephotometric determination of glucose\u003c\/strong\u003e in \u003cstrong\u003eserum, heparin plasma and EDTA plasma\u003c\/strong\u003e. The manufacturer literature identifies it as a professional \u003cstrong\u003ein vitro diagnostic\u003c\/strong\u003e reagent for serum\/plasma glucose estimation.【turn704895view0†L3-L7】【turn704895view0†L68-L79】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTest Principle\u003c\/h2\u003e\n\u003cp\u003eThe assay follows the \u003cstrong\u003eGOD-POD method\u003c\/strong\u003e:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlucose oxidase\u003c\/strong\u003e converts glucose into gluconic acid and hydrogen peroxide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeroxidase\u003c\/strong\u003e then catalyses a reaction between hydrogen peroxide and chromogenic reagents.\u003c\/li\u003e\n\u003cli\u003eA coloured quinoneimine complex is formed.\u003c\/li\u003e\n\u003cli\u003eThe colour intensity is directly proportional to the glucose concentration in the sample.【turn704895view0†L19-L33】\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eReagent Composition\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-aminoantipyrine\u003c\/td\u003e\n\u003ctd\u003e0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlucose Oxidase\u003c\/td\u003e\n\u003ctd\u003e15 kU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeroxidase\u003c\/td\u003e\n\u003ctd\u003e2 kU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhenol\u003c\/td\u003e\n\u003ctd\u003e1 ml\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eGlucose 100 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese composition details are listed in the Swemed product insert.【turn704895view0†L62-L67】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eGOD-POD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eEndpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e505 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003emg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Concentration\u003c\/td\u003e\n\u003ctd\u003e100 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Slope\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation Time\u003c\/td\u003e\n\u003ctd\u003e10 minutes at 37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanking\u003c\/td\u003e\n\u003ctd\u003eReagent Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e500 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese technical specifications are given in the quick-reference section of the Swemed insert.【turn704895view0†L143-L155】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAssay Procedure Summary\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTube\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eReagent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStandard \/ Sample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e10 µl Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003ctd\u003e10 µl Sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eAfter mixing, incubate for \u003cstrong\u003e10 minutes at 37°C\u003c\/strong\u003e and read the absorbance against the reagent blank at \u003cstrong\u003e505 nm\u003c\/strong\u003e.【turn704895view0†L105-L118】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecimen Information\u003c\/h2\u003e\n\u003cp\u003eSuitable specimen types listed in the Swemed insert are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSerum\u003c\/li\u003e\n\u003cli\u003eHeparin plasma\u003c\/li\u003e\n\u003cli\u003eEDTA plasma【turn704895view0†L68-L79】\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFresh, clear, non-haemolysed fasting serum is recommended in the manufacturer literature. The insert also notes that glucose in blood samples can decrease because of glycolysis and bacterial contamination if the sample is not handled promptly. It advises quick separation of serum from the clot and use of appropriate fluoride-containing collection practice where required to reduce glycolysis.【turn704895view0†L70-L88】【turn704895view0†L156-L159】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecimen Stability\u003c\/h2\u003e\n\u003cp\u003eAccording to the Swemed insert, glucose in serum or plasma remains stable for approximately:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eStorage Condition\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eStability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25°C\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4°C\u003c\/td\u003e\n\u003ctd\u003e72 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis applies when the sample is kept free from bacterial contamination.【turn704895view0†L84-L89】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMeasuring Range and Linearity\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer states that the assay is linear up to \u003cstrong\u003e500 mg\/dL\u003c\/strong\u003e. For values above this level, the insert recommends dilution with \u003cstrong\u003e0.9% NaCl solution\u003c\/strong\u003e and multiplication of the result according to the stated procedure.【turn704895view0†L124-L130】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eInterference Information\u003c\/h2\u003e\n\u003cp\u003eThe Swemed insert reports no significant interference under the evaluated conditions from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBilirubin up to \u003cstrong\u003e20 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAscorbic acid up to \u003cstrong\u003e5 mg\/dL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTriglycerides up to \u003cstrong\u003e2000 mg\/dL\u003c\/strong\u003e【turn704895view0†L131-L135】\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eReference Range\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer provides the following reference values:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSample Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eReference Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerum \/ Plasma Fasting\u003c\/td\u003e\n\u003ctd\u003e70–110 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 Hours Post-Prandial\u003c\/td\u003e\n\u003ctd\u003e80–140 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSF\u003c\/td\u003e\n\u003ctd\u003e50–80 mg\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eEach laboratory should validate whether these reference ranges are appropriate for its own patient population.【turn704895view0†L136-L142】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eStorage and Stability\u003c\/h2\u003e\n\u003cp\u003eThe Swemed insert states that the reagent is stable until the labelled expiry date when stored at \u003cstrong\u003e2–8°C\u003c\/strong\u003e, protected from light, with contamination avoided. The insert also states \u003cstrong\u003edo not freeze the reagents\u003c\/strong\u003e and advises use of fresh pipette tips and tightly closed caps.【turn704895view0†L47-L59】\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eUseful Tips\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the required variant: \u003cstrong\u003e500 ml or 1000 ml\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eConfirm that \u003cstrong\u003eGOD-POD glucose method\u003c\/strong\u003e is required\u003c\/li\u003e\n\u003cli\u003eEnsure analyser compatibility with \u003cstrong\u003eendpoint glucose testing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eConfirm \u003cstrong\u003e505 nm\u003c\/strong\u003e wavelength capability\u003c\/li\u003e\n\u003cli\u003eUse fresh, properly handled serum or plasma\u003c\/li\u003e\n\u003cli\u003eAvoid delay in specimen processing to reduce glycolysis\u003c\/li\u003e\n\u003cli\u003eStore the reagent as recommended by the manufacturer\u003c\/li\u003e\n\u003cli\u003eUse fresh pipette tips and avoid reagent contamination\u003c\/li\u003e\n\u003cli\u003eFollow internal calibration and quality-control procedures\u003c\/li\u003e\n\u003cli\u003eDo not use expired reagent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eWho Can Buy This Product?\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine glucose testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eBlood glucose estimation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eClinical chemistry investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiabetes Care Centres\u003c\/td\u003e\n\u003ctd\u003eGlucose testing workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinics with Laboratory Facilities\u003c\/td\u003e\n\u003ctd\u003eRoutine biochemical screening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eTeaching and diagnostic laboratory use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine serum\/plasma glucose estimation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eInstitutional procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional supply where permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eBuy Swemed Glucose Reagent in Bangalore\u003c\/h2\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003eclinical biochemistry reagents, diabetic-care related diagnostic products and laboratory consumables from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed Glucose Liquid Stable Reagent\u003c\/strong\u003e is suitable for professional procurement by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePathology laboratories in Bangalore\u003c\/li\u003e\n\u003cli\u003eDiagnostic centres in Bengaluru\u003c\/li\u003e\n\u003cli\u003eHospital laboratories in Karnataka\u003c\/li\u003e\n\u003cli\u003eDiabetes-related diagnostic facilities\u003c\/li\u003e\n\u003cli\u003eClinical chemistry laboratories\u003c\/li\u003e\n\u003cli\u003eMedical institutions\u003c\/li\u003e\n\u003cli\u003eProfessional laboratory buyers across India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCustomers can order through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e, with serviceable delivery across Bangalore and other locations in India.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSearch Relevance\u003c\/h2\u003e\n\u003cp\u003eThis product is relevant for buyers searching for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGlucose reagent supplier in Bangalore\u003c\/li\u003e\n\u003cli\u003eSwemed Glucose Reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eGOD POD glucose reagent supplier Bengaluru\u003c\/li\u003e\n\u003cli\u003eGlucose test reagent online India\u003c\/li\u003e\n\u003cli\u003eBiochemistry reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eSerum glucose reagent supplier Karnataka\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier near me\u003c\/li\u003e\n\u003cli\u003ePathology lab reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eDiagnostic reagent supplier Bengaluru\u003c\/li\u003e\n\u003cli\u003eBuy glucose reagent 500 ml online India\u003c\/li\u003e\n\u003cli\u003eBuy glucose reagent 1000 ml online India\u003c\/li\u003e\n\u003cli\u003eSwemed Diagnostics reagent supplier India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Summary\u003c\/h2\u003e\n\u003ch3\u003eWhat is Swemed Glucose Liquid Stable Reagent?\u003c\/h3\u003e\n\u003cp\u003eSwemed Glucose Liquid Stable Reagent is a professional \u003cstrong\u003eclinical biochemistry reagent\u003c\/strong\u003e used for photometric glucose estimation by the \u003cstrong\u003eGOD-POD method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhich samples can be used?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer lists \u003cstrong\u003eserum, heparin plasma and EDTA plasma\u003c\/strong\u003e as suitable specimens.【turn704895view0†L68-L79】\u003c\/p\u003e\n\u003ch3\u003eIs the reagent ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. The Swemed insert states that the reagent and standard are \u003cstrong\u003eready to use\u003c\/strong\u003e.【turn704895view0†L60-L67】\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay is performed at \u003cstrong\u003e505 nm\u003c\/strong\u003e.【turn704895view0†L105-L118】【turn704895view0†L143-L155】\u003c\/p\u003e\n\u003ch3\u003eWhat is the standard concentration?\u003c\/h3\u003e\n\u003cp\u003eThe supplied glucose standard is \u003cstrong\u003e100 mg\/dL\u003c\/strong\u003e.【turn704895view0†L62-L67】\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay linearity?\u003c\/h3\u003e\n\u003cp\u003eThe stated linearity is \u003cstrong\u003e500 mg\/dL\u003c\/strong\u003e.【turn704895view0†L124-L130】【turn704895view0†L143-L155】\u003c\/p\u003e\n\u003ch3\u003eWhich variants are available?\u003c\/h3\u003e\n\u003cp\u003eThis product is available in \u003cstrong\u003e500 ml and 1000 ml variants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhere can it be purchased?\u003c\/h3\u003e\n\u003cp\u003eThe product can be ordered from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to stock availability and serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEntity Information\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eGlucose Liquid Stable Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eGOD-POD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyte\u003c\/td\u003e\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubcategory\u003c\/td\u003e\n\u003ctd\u003eBiochemistry Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eDiabetic \/ Clinical Chemistry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum \/ Heparin Plasma \/ EDTA Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuyer Type\u003c\/td\u003e\n\u003ctd\u003eLaboratory \/ Diagnostic Centre \/ Hospital \/ B2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eWhy Buy Swemed Glucose Reagent from Microsidd.com?\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eWhen buying a laboratory reagent, the buyer should verify more than just the displayed price. Important factors include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCorrect \u003cstrong\u003ebrand\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCorrect \u003cstrong\u003emethod\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCorrect \u003cstrong\u003epack size\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCorrect \u003cstrong\u003especifications\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReagent authenticity\u003c\/li\u003e\n\u003cli\u003eSuitable storage and handling\u003c\/li\u003e\n\u003cli\u003eSeller identity\u003c\/li\u003e\n\u003cli\u003eInvoice availability\u003c\/li\u003e\n\u003cli\u003ePractical support after purchase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMicrosidd India operates as a specialist healthcare and diagnostic-products seller and supplies a wide range of laboratory and diagnostic items through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e. This helps buyers source from a specialist store rather than depending only on a random third-party marketplace listing. Microsidd also has long-standing involvement in the IVD field and established relationships across multiple diagnostic categories.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMicrosidd.com vs Online Marketplaces vs Offline Suppliers\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLarge Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline \/ Local Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Specialisation\u003c\/td\u003e\n\u003ctd\u003eFocused on diagnostic, laboratory and healthcare products\u003c\/td\u003e\n\u003ctd\u003eSeller knowledge varies widely\u003c\/td\u003e\n\u003ctd\u003eDepends on individual dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Understanding\u003c\/td\u003e\n\u003ctd\u003eBetter suited to reagent-specific queries\u003c\/td\u003e\n\u003ctd\u003eOften general support\u003c\/td\u003e\n\u003ctd\u003eDepends on local supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Identity\u003c\/td\u003e\n\u003ctd\u003eDirect purchase from Microsidd India\u003c\/td\u003e\n\u003ctd\u003eMarketplace and seller may be different\u003c\/td\u003e\n\u003ctd\u003eUsually a local dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Source Confidence\u003c\/td\u003e\n\u003ctd\u003eSpecialist diagnostic-product sourcing\u003c\/td\u003e\n\u003ctd\u003eSource depends on seller\u003c\/td\u003e\n\u003ctd\u003eVaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification\u003c\/td\u003e\n\u003ctd\u003eBrand, method and variant can be confirmed\u003c\/td\u003e\n\u003ctd\u003eSimilar listings may create confusion\u003c\/td\u003e\n\u003ctd\u003eDepends on available stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eDepends on seller\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for labs, hospitals and institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eOften local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eGrowing specialist diagnostic catalogue\u003c\/td\u003e\n\u003ctd\u003eVery broad but not specialised\u003c\/td\u003e\n\u003ctd\u003eUsually limited by local stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect Microsidd support\u003c\/td\u003e\n\u003ctd\u003eMarketplace plus seller layer\u003c\/td\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccountability\u003c\/td\u003e\n\u003ctd\u003eOne identifiable specialist seller\u003c\/td\u003e\n\u003ctd\u003eSeller can vary from listing to listing\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNationwide Access\u003c\/td\u003e\n\u003ctd\u003eIndia-wide subject to serviceability\u003c\/td\u003e\n\u003ctd\u003eBroad\u003c\/td\u003e\n\u003ctd\u003eUsually regional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of Buying from Microsidd.com\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd Advantage\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBenefit to Buyers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecialist Diagnostic Seller\u003c\/td\u003e\n\u003ctd\u003eBetter fit for laboratory and diagnostic procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIVD Sector Experience\u003c\/td\u003e\n\u003ctd\u003eGreater familiarity with diagnostic-product categories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Seller Accountability\u003c\/td\u003e\n\u003ctd\u003ePurchase directly from Microsidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eHelpful for labs, clinics and institutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification Support\u003c\/td\u003e\n\u003ctd\u003eMethod, variant and specifications can be checked before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Category Procurement\u003c\/td\u003e\n\u003ctd\u003eReagents, strips, diagnostic kits and consumables available together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBangalore-Based Operations\u003c\/td\u003e\n\u003ctd\u003eConvenient for Bengaluru and Karnataka buyers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eUseful for serviceable locations across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect order and product assistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is Swemed Glucose Liquid Stable Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is used for professional \u003cstrong\u003ephotometric glucose determination\u003c\/strong\u003e in serum and plasma by the \u003cstrong\u003eGOD-POD method\u003c\/strong\u003e.【turn704895view0†L3-L7】【turn704895view0†L19-L33】\u003c\/p\u003e\n\u003ch3\u003eWhich variants are available?\u003c\/h3\u003e\n\u003cp\u003eThis product is available in \u003cstrong\u003e500 ml and 1000 ml variants\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method does this glucose reagent use?\u003c\/h3\u003e\n\u003cp\u003eThe method is \u003cstrong\u003eGOD-POD\u003c\/strong\u003e.【turn704895view0†L3-L4】【turn417549view0†L64-L67】\u003c\/p\u003e\n\u003ch3\u003eIs this a ready-to-use reagent?\u003c\/h3\u003e\n\u003cp\u003eYes. The Swemed insert states that the reagent and standard are \u003cstrong\u003eready to use\u003c\/strong\u003e.【turn704895view0†L60-L67】\u003c\/p\u003e\n\u003ch3\u003eWhich specimens are suitable?\u003c\/h3\u003e\n\u003cp\u003eThe insert lists \u003cstrong\u003eserum, heparin plasma and EDTA plasma\u003c\/strong\u003e.【turn704895view0†L68-L79】\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e505 nm\u003c\/strong\u003e.【turn704895view0†L105-L118】【turn704895view0†L143-L155】\u003c\/p\u003e\n\u003ch3\u003eWhat is the standard concentration?\u003c\/h3\u003e\n\u003cp\u003eThe glucose standard concentration is \u003cstrong\u003e100 mg\/dL\u003c\/strong\u003e.【turn704895view0†L62-L67】\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay linearity?\u003c\/h3\u003e\n\u003cp\u003eThe stated linearity is \u003cstrong\u003e500 mg\/dL\u003c\/strong\u003e.【turn704895view0†L124-L130】【turn704895view0†L143-L155】\u003c\/p\u003e\n\u003ch3\u003eHow long is the incubation?\u003c\/h3\u003e\n\u003cp\u003eThe insert specifies \u003cstrong\u003e10 minutes at 37°C\u003c\/strong\u003e.【turn704895view0†L105-L118】【turn704895view0†L143-L155】\u003c\/p\u003e\n\u003ch3\u003eHow should the reagent be stored?\u003c\/h3\u003e\n\u003cp\u003eStore at \u003cstrong\u003e2–8°C\u003c\/strong\u003e, protect from light, avoid contamination and \u003cstrong\u003edo not freeze\u003c\/strong\u003e.【turn704895view0†L47-L59】\u003c\/p\u003e\n\u003ch3\u003eIs this suitable for home testing?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e.【turn704895view0†L5-L7】\u003c\/p\u003e\n\u003ch3\u003eCan I use this on any analyser?\u003c\/h3\u003e\n\u003cp\u003eThe laboratory should confirm analyser compatibility, wavelength capability and validated programming before purchase.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Swemed Glucose Reagent in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eIt can be ordered from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to stock availability.\u003c\/p\u003e\n\u003ch3\u003eCan buyers outside Bangalore order it?\u003c\/h3\u003e\n\u003cp\u003eYes. Microsidd serves serviceable locations across India.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMedical and Laboratory Disclaimer\u003c\/h2\u003e\n\u003cp\u003eThe information on this product page is provided for \u003cstrong\u003egeneral product identification, procurement and educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eGlucose results should not be interpreted in isolation to diagnose or exclude diabetes, hypoglycaemia or any other clinical condition. Clinical interpretation may require fasting status, post-prandial status, symptoms, history and other laboratory investigations.\u003c\/p\u003e\n\u003cp\u003eThe information provided by Microsidd India does not replace the official Swemed Diagnostics product insert, analyser instructions, laboratory standard operating procedures, calibration requirements, quality-control procedures or professional medical judgement.\u003c\/p\u003e\n\u003cp\u003eSpecimen requirements, methodology, reagent preparation, analyser settings, reference ranges, storage, stability and interpretation should always follow the current manufacturer documentation and validated laboratory procedures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eNo Return \/ No Exchange Policy\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Swemed Diagnostics","offers":[{"title":"500ml","offer_id":53143226777920,"sku":"Glucose 500ml","price":900.0,"currency_code":"INR","in_stock":true},{"title":"1000ml","offer_id":53143226810688,"sku":"Glucose 1000ml","price":1500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/Swemed_Glucose_Reagent_Kit_GOD-POD_Method_500ml_1000ml.png?v=1789135823","url":"https:\/\/microsidd.com\/products\/glucose-liquid-stable-reagent-500-ml-1000-ml","provider":"Microsidd India","version":"1.0","type":"link"}