{"product_id":"ck-mb-reagent-kit-25-ml","title":"CK-MB Reagent Kit 25 ml – Immunoinhibition Kinetic Method","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eSwemed CK-MB Reagent Kit 25 ml\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed CK-MB Reagent Kit 25 ml\u003c\/strong\u003e is a professional \u003cstrong\u003ecardiac biochemistry reagent\u003c\/strong\u003e intended for measurement of \u003cstrong\u003eCK-MB activity in serum\u003c\/strong\u003e using an \u003cstrong\u003eimmunoinhibition kinetic method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe method measures creatine kinase activity in the presence of an antibody against the CK-M subunit. According to the Swemed product literature, this antibody inhibits CK-MM activity and half of the CK-MB activity while leaving the B-subunit activity available for measurement. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCK-MB is a cardiac-associated enzyme fraction that has historically been used in laboratory assessment of myocardial injury. Modern cardiac evaluation commonly includes additional biomarkers such as cardiac troponins, and CK-MB results should always be interpreted in the context of the complete clinical picture.\u003c\/p\u003e\n\u003cp\u003eThis reagent is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e in pathology laboratories, diagnostic centres, hospitals and clinical biochemistry laboratories.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct at a Glance\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProduct Detail\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eInformation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eCK-MB Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e25 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCardiac Biochemistry Reagent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Parameter\u003c\/td\u003e\n\u003ctd\u003eCK-MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eImmunoinhibition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eKinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Temperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Slope\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Path Length\u003c\/td\u003e\n\u003ctd\u003e1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank\u003c\/td\u003e\n\u003ctd\u003eWater Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Reagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e50 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e300 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Interval\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e6752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eUp to 1500 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru, Karnataka, India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe technical assay information above is taken from Swemed Diagnostics' CK-MB product literature. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKit Components\u003c\/h1\u003e\n\u003cp\u003eThe CK-MB system consists of:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent R1\u003c\/td\u003e\n\u003ctd\u003eReady to Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent R2\u003c\/td\u003e\n\u003ctd\u003eReady to Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSwemed states that both reagents are supplied \u003cstrong\u003eready to use\u003c\/strong\u003e and remain stable until the expiry date stated on the label when stored appropriately. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Features\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSwemed Diagnostics CK-MB Reagent Kit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eConvenient \u003cstrong\u003e25 ml pack size\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eImmunoinhibition method\u003c\/li\u003e\n\u003cli\u003eKinetic assay\u003c\/li\u003e\n\u003cli\u003eDesigned for CK-MB activity measurement\u003c\/li\u003e\n\u003cli\u003eSuitable specimen: \u003cstrong\u003eserum\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement wavelength: \u003cstrong\u003e340 nm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReaction temperature: \u003cstrong\u003e37°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal reagent volume: \u003cstrong\u003e1000 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample volume: \u003cstrong\u003e50 µl\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLinearity up to \u003cstrong\u003e1500 U\/L\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eReagents supplied ready to use\u003c\/li\u003e\n\u003cli\u003eSuitable for professional cardiac biochemistry testing\u003c\/li\u003e\n\u003cli\u003eIntended for pathology laboratories, hospitals and diagnostic centres\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003ein vitro diagnostic use only\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eKey Benefits\u003c\/h1\u003e\n\u003ch2\u003eImmunoinhibition-Based CK-MB Measurement\u003c\/h2\u003e\n\u003cp\u003eThe Swemed CK-MB assay uses immunoinhibition to suppress CK-M activity, allowing measurement related to the B-subunit activity of CK-MB. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eKinetic Measurement\u003c\/h2\u003e\n\u003cp\u003eThe assay uses a kinetic measurement format with absorbance change monitored over time at \u003cstrong\u003e340 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eReady-to-Use Reagents\u003c\/h2\u003e\n\u003cp\u003eR1 and R2 are supplied ready to use, helping simplify laboratory reagent preparation.\u003c\/p\u003e\n\u003ch2\u003eConvenient 25 ml Pack\u003c\/h2\u003e\n\u003cp\u003eThe 25 ml configuration is useful for laboratories with routine or moderate CK-MB testing volumes. Swemed's current catalogue also lists CK-MB as a cardiac reagent using an immunoinhibition kinetic method. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSuitable for Cardiac Biochemistry Workflows\u003c\/h2\u003e\n\u003cp\u003eThe reagent can be incorporated into professional laboratory cardiac-marker workflows alongside other relevant tests, subject to laboratory protocols and current clinical practice.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eIntended Use\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed CK-MB Reagent Kit\u003c\/strong\u003e is intended for professional laboratory measurement of CK-MB activity in \u003cstrong\u003eserum\u003c\/strong\u003e using an immunoinhibition kinetic method.\u003c\/p\u003e\n\u003cp\u003eIt is intended for use by trained laboratory personnel and for \u003cstrong\u003ein vitro diagnostic use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTest Principle\u003c\/h1\u003e\n\u003cp\u003eThe assay measures creatine kinase activity in the presence of an antibody directed against the \u003cstrong\u003eCK-M monomer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAccording to the manufacturer:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCK-MM activity is inhibited.\u003c\/li\u003e\n\u003cli\u003eApproximately half of CK-MB activity is inhibited.\u003c\/li\u003e\n\u003cli\u003eThe B-subunit activity associated with CK-MB remains measurable.\u003c\/li\u003e\n\u003cli\u003eCK-BB activity is not inhibited by the antibody. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe resulting kinetic activity is measured photometrically.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eReagent Preparation\u003c\/h1\u003e\n\u003cp\u003eSwemed instructs laboratories to prepare the working reagent by mixing:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4 parts Reagent R1 + 1 part Reagent R2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe combined working reagent is stated to remain stable for approximately \u003cstrong\u003e2 weeks at 2–8°C\u003c\/strong\u003e, protected from direct light. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTest Parameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eCK-MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eImmunoinhibition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eKinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette\u003c\/td\u003e\n\u003ctd\u003e1 cm path length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Slope\u003c\/td\u003e\n\u003ctd\u003eIncreasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e37°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank\u003c\/td\u003e\n\u003ctd\u003eWater Blank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Reagent Volume\u003c\/td\u003e\n\u003ctd\u003e1000 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e50 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay Time\u003c\/td\u003e\n\u003ctd\u003e300 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterval Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e6752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e1500 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003ctd\u003eU\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManual Assay Procedure\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMacro Method\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSemi-Micro Method\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagent R1 + R2\u003c\/td\u003e\n\u003ctd\u003e800 + 200 µl\u003c\/td\u003e\n\u003ctd\u003e400 + 100 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample\u003c\/td\u003e\n\u003ctd\u003e50 µl\u003c\/td\u003e\n\u003ctd\u003e25 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eAfter adding the sample, mix and incubate for \u003cstrong\u003e300 seconds at 37°C\u003c\/strong\u003e. Measure the change in absorbance every minute for \u003cstrong\u003e2 minutes\u003c\/strong\u003e, then calculate the mean absorbance change per minute. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSpecimen Requirements\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer identifies \u003cstrong\u003eserum as the specimen of choice\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwemed also notes that CK-MB activity decreases relatively quickly after collection, reporting approximately \u003cstrong\u003e10% loss of activity after 1 hour at 25°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eProper sample collection, handling and timely analysis are therefore important.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eManufacturer Reference Value\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eManufacturer Reference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCK-MB\u003c\/td\u003e\n\u003ctd\u003e0–24 U\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eEach laboratory should validate reference intervals according to its own population, analyser configuration, method and laboratory policy. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eClinical Significance\u003c\/h1\u003e\n\u003cp\u003eCK-MB is an isoenzyme of creatine kinase that has historically been associated with cardiac muscle injury.\u003c\/p\u003e\n\u003cp\u003eThe Swemed insert states that CK-MB levels may rise within several hours following myocardial infarction, reach a peak later, and subsequently decline when no further myocardial injury occurs. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn current clinical practice, \u003cstrong\u003ecardiac troponins are generally the preferred biomarkers for diagnosing acute myocardial injury\u003c\/strong\u003e, while CK-MB may still have a role in selected laboratory or clinical circumstances.\u003c\/p\u003e\n\u003cp\u003eCK-MB results should never be interpreted in isolation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCK-MB in a Cardiac Laboratory Profile\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eTest\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLaboratory Relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCK-MB\u003c\/td\u003e\n\u003ctd\u003eCardiac-associated creatine kinase fraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal CK \/ CK-NAC\u003c\/td\u003e\n\u003ctd\u003eTotal creatine kinase activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTroponin I \/ T\u003c\/td\u003e\n\u003ctd\u003eMajor biomarkers of myocardial injury\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLDH\u003c\/td\u003e\n\u003ctd\u003eTissue injury-related enzyme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAST \/ SGOT\u003c\/td\u003e\n\u003ctd\u003eMay be elevated in several tissue-injury conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eWho Can Buy This Product?\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuyer Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePathology Laboratories\u003c\/td\u003e\n\u003ctd\u003eCK-MB and cardiac biochemistry testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Centres\u003c\/td\u003e\n\u003ctd\u003eCardiac-marker investigations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital Laboratories\u003c\/td\u003e\n\u003ctd\u003eEmergency and inpatient laboratory testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCardiac Hospitals\u003c\/td\u003e\n\u003ctd\u003eProfessional cardiac biochemistry testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical Institutions\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and teaching laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Chemistry Laboratories\u003c\/td\u003e\n\u003ctd\u003eRoutine enzyme testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHealthcare Organisations\u003c\/td\u003e\n\u003ctd\u003eInstitutional laboratory procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Distributors\u003c\/td\u003e\n\u003ctd\u003eProfessional supply where permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eUseful Tips Before Ordering\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that \u003cstrong\u003eCK-MB Immunoinhibition\u003c\/strong\u003e is the required methodology.\u003c\/li\u003e\n\u003cli\u003eConfirm the pack size: \u003cstrong\u003e25 ml\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eEnsure the analyser supports kinetic measurement at \u003cstrong\u003e340 nm\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm compatibility with the laboratory's validated analyser application.\u003c\/li\u003e\n\u003cli\u003eVerify that testing can be performed at \u003cstrong\u003e37°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm required reagent and sample volumes.\u003c\/li\u003e\n\u003cli\u003eFollow the stated \u003cstrong\u003e4:1 R1:R2 working reagent ratio\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eProtect prepared working reagent from direct light.\u003c\/li\u003e\n\u003cli\u003eUse serum specimens according to laboratory protocol.\u003c\/li\u003e\n\u003cli\u003eAnalyse specimens promptly because enzyme activity may decline over time.\u003c\/li\u003e\n\u003cli\u003eFollow internal quality-control procedures before reporting results.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eBuy Swemed CK-MB Reagent in Bangalore\u003c\/h1\u003e\n\u003cp\u003eMicrosidd India supplies \u003cstrong\u003ecardiac biochemistry reagents and laboratory diagnostic products from Bangalore \/ Bengaluru, Karnataka\u003c\/strong\u003e for professional pathology laboratories, diagnostic centres, hospitals and institutional healthcare buyers.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed CK-MB Reagent Kit 25 ml\u003c\/strong\u003e is suitable for laboratories performing professional clinical chemistry and cardiac-marker testing and can be ordered through \u003cstrong\u003emicrosidd.com\u003c\/strong\u003e, subject to stock availability and delivery serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSearch Relevance\u003c\/h1\u003e\n\u003cp\u003eThis product is relevant for buyers searching for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCK-MB reagent supplier in Bangalore\u003c\/li\u003e\n\u003cli\u003eSwemed CK-MB Reagent Bangalore\u003c\/li\u003e\n\u003cli\u003eCK-MB reagent 25 ml\u003c\/li\u003e\n\u003cli\u003eCK-MB immunoinhibition reagent India\u003c\/li\u003e\n\u003cli\u003eCardiac reagent supplier Bengaluru\u003c\/li\u003e\n\u003cli\u003eCardiac biochemistry reagent supplier Bangalore\u003c\/li\u003e\n\u003cli\u003eClinical chemistry reagent supplier Karnataka\u003c\/li\u003e\n\u003cli\u003ePathology lab reagent supplier near me\u003c\/li\u003e\n\u003cli\u003eCK-MB kit online India\u003c\/li\u003e\n\u003cli\u003eSwemed Diagnostics reagent supplier India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct Summary\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed CK-MB Reagent Kit 25 ml?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSwemed CK-MB Reagent Kit 25 ml\u003c\/strong\u003e is a professional clinical biochemistry reagent for measuring CK-MB activity in serum using an \u003cstrong\u003eimmunoinhibition kinetic method\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat methodology does the Swemed CK-MB reagent use?\u003c\/h3\u003e\n\u003cp\u003eIt uses an \u003cstrong\u003eimmunoinhibition method\u003c\/strong\u003e with kinetic measurement. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich specimen is used?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer identifies \u003cstrong\u003eserum as the sample of choice\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is required?\u003c\/h3\u003e\n\u003cp\u003eThe assay is measured at \u003cstrong\u003e340 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's macro procedure uses \u003cstrong\u003e50 µl serum\u003c\/strong\u003e, while the semi-micro procedure uses \u003cstrong\u003e25 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the linearity?\u003c\/h3\u003e\n\u003cp\u003eThe product insert states linearity up to \u003cstrong\u003e1500 U\/L\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAre the reagents ready to use?\u003c\/h3\u003e\n\u003cp\u003eYes. Reagent R1 and Reagent R2 are supplied ready to use. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhere can Swemed CK-MB reagent be purchased?\u003c\/h3\u003e\n\u003cp\u003eThe product can be purchased from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eEntity Information\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eEntity\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eCK-MB Reagent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSwemed Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e25 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eImmunoinhibition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eKinetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eCK-MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen\u003c\/td\u003e\n\u003ctd\u003eSerum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eLaboratory Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubcategory\u003c\/td\u003e\n\u003ctd\u003eBiochemistry Reagents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinical Category\u003c\/td\u003e\n\u003ctd\u003eCardiac Markers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller\u003c\/td\u003e\n\u003ctd\u003eMicrosidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003eBangalore \/ Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eState\u003c\/td\u003e\n\u003ctd\u003eKarnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWebsite\u003c\/td\u003e\n\u003ctd\u003emicrosidd.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuyer Type\u003c\/td\u003e\n\u003ctd\u003eB2B \/ Laboratory \/ Healthcare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eWhy Buy Swemed CK-MB Reagent from Microsidd.com?\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eCardiac and biochemistry reagents require careful procurement because laboratories need the \u003cstrong\u003ecorrect analyte, method, reagent configuration, pack size, analyser compatibility, storage conditions, expiry and dependable seller support\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMicrosidd India has been involved in the \u003cstrong\u003eIVD and diagnostic-product sector since 2000\u003c\/strong\u003e and specialises in diagnostic, laboratory and healthcare supplies rather than operating as a general-purpose ecommerce marketplace.\u003c\/p\u003e\n\u003cp\u003eMicrosidd also maintains established manufacturer and authorised brand relationships across several diagnostic categories, giving professional buyers the advantage of purchasing through an identifiable diagnostic-products specialist.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMicrosidd.com vs Online Marketplaces vs Offline Suppliers\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd.com\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLarge Online Marketplaces\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOffline \/ Local Suppliers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Specialisation\u003c\/td\u003e\n\u003ctd\u003eDiagnostic and laboratory focused\u003c\/td\u003e\n\u003ctd\u003eSeller expertise varies\u003c\/td\u003e\n\u003ctd\u003eDepends on dealer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Knowledge\u003c\/td\u003e\n\u003ctd\u003eSuitable for laboratory-product enquiries\u003c\/td\u003e\n\u003ctd\u003eOften general marketplace support\u003c\/td\u003e\n\u003ctd\u003eDealer dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Identity\u003c\/td\u003e\n\u003ctd\u003eDirect purchase from Microsidd India\u003c\/td\u003e\n\u003ctd\u003eMarketplace and actual seller may differ\u003c\/td\u003e\n\u003ctd\u003eUsually identifiable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Relationships\u003c\/td\u003e\n\u003ctd\u003eEstablished diagnostic manufacturer relationships across multiple categories\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eVaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod Verification\u003c\/td\u003e\n\u003ctd\u003eProduct parameter and methodology can be checked before ordering\u003c\/td\u003e\n\u003ctd\u003eSimilar listings may cause confusion\u003c\/td\u003e\n\u003ctd\u003eDepends on stock and dealer knowledge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eAvailable for eligible purchases\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eMay vary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2B Procurement\u003c\/td\u003e\n\u003ctd\u003eSuitable for laboratories and healthcare institutions\u003c\/td\u003e\n\u003ctd\u003eSeller dependent\u003c\/td\u003e\n\u003ctd\u003eUsually local\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSpecialist laboratory and diagnostic catalogue\u003c\/td\u003e\n\u003ctd\u003eBroad but not specialised\u003c\/td\u003e\n\u003ctd\u003eUsually limited by local stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomer Support\u003c\/td\u003e\n\u003ctd\u003eDirect Microsidd support\u003c\/td\u003e\n\u003ctd\u003eMarketplace plus seller layer\u003c\/td\u003e\n\u003ctd\u003eLocal support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeller Accountability\u003c\/td\u003e\n\u003ctd\u003eOne identifiable specialist supplier\u003c\/td\u003e\n\u003ctd\u003eSeller may vary by listing\u003c\/td\u003e\n\u003ctd\u003eDepends on supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnline Convenience\u003c\/td\u003e\n\u003ctd\u003eDirect ordering through microsidd.com\u003c\/td\u003e\n\u003ctd\u003eConvenient\u003c\/td\u003e\n\u003ctd\u003eMay require phone or store visit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeographic Reach\u003c\/td\u003e\n\u003ctd\u003eIndia-wide subject to serviceability\u003c\/td\u003e\n\u003ctd\u003eBroad\u003c\/td\u003e\n\u003ctd\u003eUsually regional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eBenefits of Buying from Microsidd.com\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMicrosidd Advantage\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBenefit to Laboratory Buyers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Product Specialisation\u003c\/td\u003e\n\u003ctd\u003eBetter suited to professional laboratory procurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIVD Experience Since 2000\u003c\/td\u003e\n\u003ctd\u003eLong-standing experience in diagnostic-product supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Relationships\u003c\/td\u003e\n\u003ctd\u003eEstablished relationships across diagnostic categories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Seller Accountability\u003c\/td\u003e\n\u003ctd\u003ePurchase directly from Microsidd India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGST Invoice\u003c\/td\u003e\n\u003ctd\u003eUseful for laboratories and institutional buyers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Verification Support\u003c\/td\u003e\n\u003ctd\u003eMethod, pack and product specifications can be confirmed before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Category Procurement\u003c\/td\u003e\n\u003ctd\u003eCardiac, biochemistry, rapid-test and laboratory products available together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBangalore-Based Operations\u003c\/td\u003e\n\u003ctd\u003eConvenient for laboratories in Bengaluru and Karnataka\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndia-Wide Supply\u003c\/td\u003e\n\u003ctd\u003eDelivery to serviceable locations across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Customer Support\u003c\/td\u003e\n\u003ctd\u003eProduct and order queries handled directly by Microsidd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ch3\u003eWhat is Swemed CK-MB Reagent used for?\u003c\/h3\u003e\n\u003cp\u003eIt is intended for professional measurement of \u003cstrong\u003eCK-MB activity in serum\u003c\/strong\u003e using an immunoinhibition kinetic method.\u003c\/p\u003e\n\u003ch3\u003eWhat is the pack size?\u003c\/h3\u003e\n\u003cp\u003eThe listed pack size is \u003cstrong\u003e25 ml\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat method does the Swemed CK-MB Kit use?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses an \u003cstrong\u003eimmunoinhibition kinetic method\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhich specimen is recommended?\u003c\/h3\u003e\n\u003cp\u003eSwemed identifies \u003cstrong\u003eserum as the sample of choice\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat wavelength is used?\u003c\/h3\u003e\n\u003cp\u003eThe assay uses \u003cstrong\u003e340 nm\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the reaction temperature?\u003c\/h3\u003e\n\u003cp\u003eThe assay is performed at \u003cstrong\u003e37°C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the total reagent volume?\u003c\/h3\u003e\n\u003cp\u003eThe stated reagent volume is \u003cstrong\u003e1000 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the sample volume?\u003c\/h3\u003e\n\u003cp\u003eThe macro procedure uses \u003cstrong\u003e50 µl\u003c\/strong\u003e and the semi-micro procedure uses \u003cstrong\u003e25 µl\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat is the assay linearity?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer insert states \u003cstrong\u003e1500 U\/L\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow are R1 and R2 prepared?\u003c\/h3\u003e\n\u003cp\u003eMix \u003cstrong\u003e4 parts R1 with 1 part R2\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHow long is the combined reagent stable?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer states approximately \u003cstrong\u003e2 weeks at 2–8°C\u003c\/strong\u003e, protected from direct light. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIs CK-MB a cardiac marker?\u003c\/h3\u003e\n\u003cp\u003eCK-MB is a cardiac-associated creatine kinase isoenzyme historically used in the laboratory evaluation of myocardial injury. Current interpretation should follow contemporary clinical practice and should not rely on CK-MB alone.\u003c\/p\u003e\n\u003ch3\u003eIs the reagent suitable for home testing?\u003c\/h3\u003e\n\u003cp\u003eNo. It is intended for \u003cstrong\u003eprofessional in vitro diagnostic use only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan this reagent be used on any biochemistry analyser?\u003c\/h3\u003e\n\u003cp\u003eThe laboratory should verify analyser compatibility, wavelength, kinetic programming, reaction temperature and validated method before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Swemed CK-MB Reagent in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eThe product can be ordered from \u003cstrong\u003eMicrosidd India through microsidd.com\u003c\/strong\u003e, subject to stock availability.\u003c\/p\u003e\n\u003ch3\u003eCan laboratories outside Bangalore purchase it?\u003c\/h3\u003e\n\u003cp\u003eYes. Microsidd supplies diagnostic and laboratory products to serviceable locations across India.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMedical and Laboratory Disclaimer\u003c\/h1\u003e\n\u003cp\u003eThe information on this product page is provided for \u003cstrong\u003egeneral product identification, procurement and educational purposes only\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis product is intended for \u003cstrong\u003eprofessional in vitro diagnostic use by trained laboratory personnel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCK-MB is a laboratory biomarker and should not be used alone to diagnose or exclude myocardial infarction or other cardiac conditions. Current clinical evaluation of suspected myocardial injury may require cardiac troponins, ECG findings, symptoms and other clinical investigations.\u003c\/p\u003e\n\u003cp\u003eThe information provided by Microsidd India does not replace the official Swemed Diagnostics package insert, analyser instructions, laboratory standard operating procedures, calibration requirements, quality-control procedures or professional medical judgement.\u003c\/p\u003e\n\u003cp\u003eSpecimen requirements, methodology, reagent preparation, analyser settings, reference intervals, storage, stability, quality-control requirements and interpretation must always follow the current manufacturer instructions and validated laboratory procedures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eNo Return \/ No Exchange Policy\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThis product is non-returnable and non-exchangeable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify the \u003cstrong\u003ebrand, model, compatibility, pack size and product specifications before placing your order\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor laboratory reagents, customers should specifically verify the \u003cstrong\u003etest parameter, methodology, analyser compatibility, reagent configuration and pack size\u003c\/strong\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving an \u003cstrong\u003eincorrect product received\u003c\/strong\u003e will be handled separately according to Microsidd.com's applicable policies and applicable law.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Swemed Diagnostics","offers":[{"title":"Default Title","offer_id":53143070310720,"sku":"CKMB 25ML","price":3499.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/Swemed_CK-MB_Reagent_Kit_25ml_ImmunoinhibitionMethodMicrosidd.png?v=1789126282","url":"https:\/\/microsidd.com\/products\/ck-mb-reagent-kit-25-ml","provider":"Microsidd India","version":"1.0","type":"link"}