{"product_id":"biolab-rapid-malaria-stain-jsb-i-ii-2x500ml","title":"Biolab Rapid Malaria Stain Kit JSB I \u0026 II 2×500 mL | One-Minute Blood Parasite Stain","description":"\u003ch2\u003eBiolab Rapid Malaria Stain Kit JSB I \u0026amp; II | 2 × 500 mL | One-Minute Blood Parasite Stain\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBiolab Rapid Malaria Stain Kit (JSB I \u0026amp; II)\u003c\/strong\u003e is a professional laboratory staining system designed for rapid staining of peripheral blood smears for microscopic demonstration of \u003cstrong\u003emalaria parasites and blood-cell morphology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe system uses \u003cstrong\u003epolychromated Methylene Blue and Eosin\u003c\/strong\u003e to differentially stain basophilic and acidophilic cellular components, helping laboratory professionals visualise blood cells and haemoparasites during microscopy.\u003c\/p\u003e\n\u003cp\u003eThe principal stain pack contains:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eRapid-Malaria JSB I – 500 mL\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRapid-Malaria JSB II – 500 mL\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Biolab manufacturer insert also lists an \u003cstrong\u003eEasyfix Peripheral Smear Fixative – 50 mL\u003c\/strong\u003e within the staining system. Verify the exact contents of the current supplied pack before ordering if the fixative is specifically required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Biolab Diagnostics\u003cbr\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e Rapid Malaria Stain Kit – JSB I \u0026amp; II\u003cbr\u003e\u003cstrong\u003ePack Size:\u003c\/strong\u003e 2 × 500 mL main stain reagents\u003cbr\u003e\u003cstrong\u003eMethod:\u003c\/strong\u003e Rapid JSB Blood Parasite Staining\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Malaria Parasite Microscopy\u003cbr\u003e\u003cstrong\u003eIntended User:\u003c\/strong\u003e Professional Laboratory Personnel\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003ePrimary Uses \u0026amp; Applications\u003c\/h2\u003e\n\u003cp\u003eBiolab Rapid Malaria Stain is primarily designed for staining peripheral blood smears for microscopic examination of malaria parasites.\u003c\/p\u003e\n\u003cp\u003eProfessional applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMalaria parasite screening by microscopy\u003c\/li\u003e\n\u003cli\u003ePeripheral blood smear examination\u003c\/li\u003e\n\u003cli\u003eThin-smear staining\u003c\/li\u003e\n\u003cli\u003eThick-smear staining\u003c\/li\u003e\n\u003cli\u003eHaemoparasite microscopy\u003c\/li\u003e\n\u003cli\u003eClinical pathology laboratories\u003c\/li\u003e\n\u003cli\u003eHaematology laboratories\u003c\/li\u003e\n\u003cli\u003eHospital diagnostic laboratories\u003c\/li\u003e\n\u003cli\u003eMalaria screening programmes\u003c\/li\u003e\n\u003cli\u003eTeaching laboratories and medical colleges\u003c\/li\u003e\n\u003cli\u003eProfessional parasitology workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer insert specifically describes microscopic appearance for malaria parasites including \u003cem\u003ePlasmodium vivax\u003c\/em\u003e trophozoites and \u003cem\u003ePlasmodium falciparum\u003c\/em\u003e trophozoites \/ gametocytes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eHow Biolab JSB Malaria Stain Works\u003c\/h2\u003e\n\u003cp\u003eThe staining principle is based on the differential affinity of \u003cstrong\u003epolychromated Methylene Blue and Eosin\u003c\/strong\u003e for cellular structures.\u003c\/p\u003e\n\u003cp\u003eBiolab states that the stains react specifically with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBasophilic cellular components\u003c\/li\u003e\n\u003cli\u003eAcidophilic cellular components\u003c\/li\u003e\n\u003cli\u003eBlood cells\u003c\/li\u003e\n\u003cli\u003eHaemoparasites\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis produces colour contrast that allows malaria parasites and blood-cell structures to be visualised microscopically.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRapid Malaria Stain – Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Biolab Diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Rapid Malaria Stain JSB I \u0026amp; II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack:\u003c\/strong\u003e 2 × 500 mL\u003c\/li\u003e\n\u003cli\u003eRapid blood-parasite staining system\u003c\/li\u003e\n\u003cli\u003eDesigned for malaria parasite microscopy\u003c\/li\u003e\n\u003cli\u003eSuitable for thin peripheral blood smears\u003c\/li\u003e\n\u003cli\u003eSuitable for thick peripheral blood smears\u003c\/li\u003e\n\u003cli\u003eReady-to-use reagents\u003c\/li\u003e\n\u003cli\u003eNo working-reagent preparation required\u003c\/li\u003e\n\u003cli\u003eUses Methylene Blue \/ Eosin-based differential staining\u003c\/li\u003e\n\u003cli\u003eCompatible with manual slide staining\u003c\/li\u003e\n\u003cli\u003eSuitable for Coplin-jar \/ wide-mouth bottle workflows\u003c\/li\u003e\n\u003cli\u003eCan also be used in bulk slide-staining workflows according to the IFU\u003c\/li\u003e\n\u003cli\u003eMicroscopic examination performed under oil immersion\u003c\/li\u003e\n\u003cli\u003eLong manufacturer-stated reagent stability when stored correctly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eKit Composition\u003c\/h2\u003e\n\u003ch3\u003eRapid-Malaria JSB I – 500 mL\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer insert lists:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMethylene Blue – 4.3 mmol\/L\u003c\/li\u003e\n\u003cli\u003eSulphuric Acid – 1%\u003c\/li\u003e\n\u003cli\u003ePotassium Dichromate\u003c\/li\u003e\n\u003cli\u003ePhosphate Buffer\u003c\/li\u003e\n\u003cli\u003ePolychromating materials\u003c\/li\u003e\n\u003cli\u003ePreservatives\u003c\/li\u003e\n\u003cli\u003eStabilisers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRapid-Malaria JSB II – 500 mL\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer insert lists:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEosin – 4.3 mmol\/L\u003c\/li\u003e\n\u003cli\u003ePhosphate-based buffer system\u003c\/li\u003e\n\u003cli\u003ePreservatives\u003c\/li\u003e\n\u003cli\u003eStabilisers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEasyfix Peripheral Smear Fixative\u003c\/h3\u003e\n\u003cp\u003eThe Biolab insert also lists \u003cstrong\u003eEasyfix Peripheral Smear Fixative – 50 mL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBecause commercial pack configurations can change, laboratories requiring the fixative should verify the current sealed-pack contents before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eReady-to-Use Reagents\u003c\/h2\u003e\n\u003cp\u003eBiolab specifies that the reagents are \u003cstrong\u003eready to use\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eNo dilution or working-reagent preparation is described for the JSB I and JSB II stains.\u003c\/p\u003e\n\u003cp\u003eThis simplifies routine laboratory staining and helps reduce reagent-preparation variability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSample \/ Specimen\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer insert describes the use of \u003cstrong\u003eperipheral blood samples prepared on clean glass slides\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBlood samples may be obtained during febrile episodes when malaria is clinically suspected.\u003c\/p\u003e\n\u003cp\u003eBiolab also states that \u003cstrong\u003eEDTA-anticoagulated blood may be used\u003c\/strong\u003e without substantial change in staining results.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eThin Blood Smear Application\u003c\/h2\u003e\n\u003cp\u003eA thin peripheral blood film may be prepared by spreading a small drop of blood with a fine-edged spreader.\u003c\/p\u003e\n\u003cp\u003eThe smear should be:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAir dried\u003c\/li\u003e\n\u003cli\u003eFixed using the appropriate fixative according to the laboratory procedure\u003c\/li\u003e\n\u003cli\u003eStained using JSB II followed by JSB I according to the Biolab method\u003c\/li\u003e\n\u003cli\u003eWashed appropriately\u003c\/li\u003e\n\u003cli\u003eAir dried before microscopy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFixed smears may be stored for a longer period, although Biolab recommends staining as soon as reasonably possible.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRapid Thin-Smear Staining Procedure\u003c\/h2\u003e\n\u003cp\u003eAccording to the current manufacturer insert:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePrepare and air-dry the thin smear.\u003c\/li\u003e\n\u003cli\u003eApply RAPID-MALARIA JSB stain fixative and allow the smear to dry.\u003c\/li\u003e\n\u003cli\u003eDip the fixed smear in \u003cstrong\u003eRapid-Malaria JSB II for approximately 3–5 seconds\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWash in running tap water.\u003c\/li\u003e\n\u003cli\u003eDip the smear in \u003cstrong\u003eRapid-Malaria JSB I for approximately 35–45 seconds\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWash in running tap water.\u003c\/li\u003e\n\u003cli\u003eAllow the smear to air dry.\u003c\/li\u003e\n\u003cli\u003eExamine under oil immersion for malaria parasites.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eBiolab notes that staining time may be increased or decreased depending on the individual staining result.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eThick Blood Smear Application\u003c\/h2\u003e\n\u003cp\u003eThick smears are useful where a greater volume of blood is examined microscopically.\u003c\/p\u003e\n\u003cp\u003eThe Biolab procedure includes a \u003cstrong\u003edehaemoglobinisation step\u003c\/strong\u003e for thick smears before staining.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRapid Thick-Smear Procedure\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003ePrepare an air-dried thick smear.\u003c\/li\u003e\n\u003cli\u003eKeep the smear side facing upward.\u003c\/li\u003e\n\u003cli\u003eAdd distilled water and allow approximately \u003cstrong\u003e1–2 minutes\u003c\/strong\u003e for dehaemoglobinisation.\u003c\/li\u003e\n\u003cli\u003eCarefully remove the water.\u003c\/li\u003e\n\u003cli\u003eAllow the slide to air dry.\u003c\/li\u003e\n\u003cli\u003eFix according to the manufacturer's prescribed procedure.\u003c\/li\u003e\n\u003cli\u003eDip the smear in \u003cstrong\u003eRapid-Malaria JSB II for approximately 5–6 seconds\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWash in running tap water.\u003c\/li\u003e\n\u003cli\u003eDip in \u003cstrong\u003eRapid-Malaria JSB I for approximately 35–45 seconds\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWash in running tap water.\u003c\/li\u003e\n\u003cli\u003eDry and examine under oil immersion.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eAlways follow the current pack insert supplied with the actual reagent lot, particularly for smear fixation and thick-smear processing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eExpected Microscopic Staining Appearance\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eStructure\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eManufacturer-Described Appearance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eLeucocyte Nuclei\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eVarying shades of dark blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eLeucocyte Cytoplasm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePale or light blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eRed Blood Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePale reddish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMalaria Parasites\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eVarying shades of blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSchüffner's Dots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDark bluish-red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePlatelets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePale or dark blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eBulk Slide Staining\u003c\/h2\u003e\n\u003cp\u003eThe Biolab IFU also describes bulk staining using staining tanks \/ slide holders.\u003c\/p\u003e\n\u003cp\u003eThis may be useful for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHospital laboratories\u003c\/li\u003e\n\u003cli\u003eHigh-volume malaria screening\u003c\/li\u003e\n\u003cli\u003ePublic-health laboratories\u003c\/li\u003e\n\u003cli\u003eTeaching laboratories\u003c\/li\u003e\n\u003cli\u003eBatch processing of multiple slides\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe exact bulk-staining sequence and timings should follow the current Biolab pack insert.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eStorage \u0026amp; Stability\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer insert states that the reagents are stable when stored at approximately \u003cstrong\u003e25–35°C\u003c\/strong\u003e for up to \u003cstrong\u003e60 months\u003c\/strong\u003e, subject to the expiry printed on the actual supplied product.\u003c\/p\u003e\n\u003cp\u003eImportant storage precautions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeep bottles tightly closed.\u003c\/li\u003e\n\u003cli\u003eProtect reagents from contamination.\u003c\/li\u003e\n\u003cli\u003eStore within the manufacturer-specified temperature range.\u003c\/li\u003e\n\u003cli\u003eKeep the fixative away from heat and fire.\u003c\/li\u003e\n\u003cli\u003eDo not use reagents after the printed expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBiolab also notes that JSB stain may become exhausted after prolonged use, particularly after staining a large number of smears.\u003c\/p\u003e\n\u003cp\u003eIf staining becomes progressively lighter, the reagent should be replaced according to laboratory QC practice.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eQuality Control\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer recommends periodically checking stain performance using:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKnown positive malaria samples\u003c\/li\u003e\n\u003cli\u003eKnown negative samples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLaboratories should maintain appropriate staining controls and documented QC procedures.\u003c\/p\u003e\n\u003cp\u003eStain performance should be reviewed whenever:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStaining becomes unusually light\u003c\/li\u003e\n\u003cli\u003eBackground appearance changes\u003c\/li\u003e\n\u003cli\u003eParasite morphology becomes difficult to distinguish\u003c\/li\u003e\n\u003cli\u003eA new lot is opened\u003c\/li\u003e\n\u003cli\u003eReagent contamination is suspected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eImportant Limitations\u003c\/h2\u003e\n\u003cp\u003eMicroscopic malaria examination depends on more than the staining reagent alone.\u003c\/p\u003e\n\u003cp\u003eThe Biolab IFU specifically notes that accuracy also depends on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCorrect staining performance\u003c\/li\u003e\n\u003cli\u003eProfessional experience\u003c\/li\u003e\n\u003cli\u003eProper smear preparation\u003c\/li\u003e\n\u003cli\u003eA good optical microscope system\u003c\/li\u003e\n\u003cli\u003eAppropriate magnification\u003c\/li\u003e\n\u003cli\u003eAbility to clearly identify parasite morphology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA negative smear does not always exclude malaria, particularly when parasitaemia is low or specimen timing \/ preparation is suboptimal.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRapid Malaria Stain Kit JSB I \u0026amp; II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBiolab Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMain Pack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2 × 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eJSB I\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eJSB II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eFixative Listed in IFU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eEasyfix Peripheral Smear Fixative – 50 mL; verify current supplied pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRapid JSB Differential Staining\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMalaria Parasite \/ Haemoparasite Microscopy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eSpecimen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePeripheral Blood Smear \/ EDTA Blood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eThin Smear JSB II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 3–5 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eThin Smear JSB I\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 35–45 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eThick Smear JSB II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 5–6 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eThick Smear JSB I\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eApprox. 35–45 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMicroscopy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOil Immersion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eWorking Reagent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eReady to Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eManufacturer IFU states approximately 25–35°C; follow actual pack label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUp to approximately 60 Months according to IFU; verify actual expiry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eIntended User\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eProfessional Laboratory Personnel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eBenefits of Biolab Rapid Malaria JSB Stain\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Staining:\u003c\/strong\u003e Designed for fast malaria parasite staining\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReady to Use:\u003c\/strong\u003e No working-reagent preparation required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThin \u0026amp; Thick Smears:\u003c\/strong\u003e Supports both common malaria microscopy formats\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge 500 mL Packs:\u003c\/strong\u003e Suitable for routine and higher-volume laboratories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Colour Contrast:\u003c\/strong\u003e Helps visualise parasites and blood-cell morphology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual or Bulk Workflow:\u003c\/strong\u003e Suitable for Coplin jars and slide-rack staining\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Stability:\u003c\/strong\u003e Manufacturer lists extended stability under prescribed storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Malaria Screening:\u003c\/strong\u003e Suitable for laboratory microscopy programmes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eJSB Rapid Malaria Stain vs Conventional Longer Staining Methods\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBiolab Rapid JSB I \u0026amp; II\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eConventional Longer Staining Method\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eWorkflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRapid stain sequence\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUsually longer stain contact time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eThin Smear\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupported depending on method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eThick Smear\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSupported depending on method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eReagent Preparation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eReady to use\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMethod dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBest Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRapid routine microscopy\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDepends on laboratory SOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy Biolab Rapid Malaria Stain from Microsidd India?\u003c\/h2\u003e\n\u003cp\u003eMalaria staining reagents can differ significantly in \u003cstrong\u003emethod, stain composition, staining sequence, timing, pack size and smear compatibility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMicrosidd clearly identifies this product as \u003cstrong\u003eBiolab Rapid Malaria Stain Kit – JSB I \u0026amp; II – 2 × 500 mL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBuying Factor\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMicrosidd India\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eGeneral Online Marketplace\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTypical Offline Store\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eExact Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eJSB I \u0026amp; II clearly stated\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMay be listed simply as malaria stain\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDepends on staff familiarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e2 × 500 mL clearly stated\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMay differ by seller\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDepends on local stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProcedure Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eThin- and thick-smear applications explained\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eListing detail varies\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUsually dependent on staff knowledge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eIFU Verification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eManufacturer instructions emphasised\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller dependent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eStore dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eGST Invoice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAvailable for eligible orders\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller dependent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eStore dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eBengaluru Presence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRT Nagar, Bengaluru\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eSeller may be located elsewhere\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDepends on local availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eIndia-Wide Ordering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAvailable to serviceable locations\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePlatform dependent\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eUsually local purchase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eBuy Rapid Malaria Stain in Bangalore\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMicrosidd India\u003c\/strong\u003e supplies laboratory stains, malaria microscopy reagents, diagnostic reagents and professional laboratory consumables from \u003cstrong\u003eRT Nagar, Bengaluru\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCustomers searching for \u003cstrong\u003emalaria stain kit Bangalore\u003c\/strong\u003e, JSB stain Bengaluru, Biolab Rapid Malaria Stain near me, blood parasite stain RT Nagar, malaria microscopy stain Bangalore, JSB I \u0026amp; II supplier Karnataka or Biolab Diagnostics supplier Bengaluru can check current availability through Microsidd.com.\u003c\/p\u003e\n\u003cp\u003eLaboratories and institutions requiring multiple bottles should confirm current stock, batch and expiry before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMicrosidd India – NAP\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBusiness Name:\u003c\/strong\u003e Microsidd India\u003cbr\u003e\u003cstrong\u003eAddress:\u003c\/strong\u003e #09 Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India\u003cbr\u003e\u003cstrong\u003ePhone \/ WhatsApp:\u003c\/strong\u003e +91 63667 72288\u003cbr\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e support@microsidd.com\u003cbr\u003e\u003cstrong\u003eWebsite:\u003c\/strong\u003e https:\/\/microsidd.com\u003cbr\u003e\u003cstrong\u003eWorking Hours:\u003c\/strong\u003e Monday to Saturday, 10:00 AM – 6:00 PM IST\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/share.google\/NWhhEfmvlEyIfAShq\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cstrong\u003eView Microsidd India on Google Maps\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eBrowse related laboratory products in \u003ca href=\"https:\/\/microsidd.com\/collections\/laboratory-needs\"\u003e\u003cstrong\u003eMicrosidd Laboratory Needs\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eBrowse professional reagents in \u003ca href=\"https:\/\/microsidd.com\/collections\/bio-chemistry-reagents\"\u003e\u003cstrong\u003eMicrosidd Laboratory Reagents\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFor local ordering information, visit \u003ca href=\"https:\/\/microsidd.com\/pages\/microsidd-india-bangalore\"\u003e\u003cstrong\u003eMicrosidd India – Laboratory \u0026amp; Medical Supplies Bangalore\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions – Biolab Rapid Malaria Stain JSB I \u0026amp; II\u003c\/h2\u003e\n\u003ch3\u003eWhat is the exact product?\u003c\/h3\u003e\n\u003cp\u003eThis listing is for \u003cstrong\u003eBiolab Rapid Malaria Stain Kit – JSB I \u0026amp; II\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the pack size?\u003c\/h3\u003e\n\u003cp\u003eThe main stain pack contains \u003cstrong\u003eJSB I 500 mL + JSB II 500 mL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eIs a fixative included?\u003c\/h3\u003e\n\u003cp\u003eThe supplied Biolab IFU lists an Easyfix Peripheral Smear Fixative 50 mL. Because pack configurations may change, confirm the actual current commercial pack if the fixative is specifically required.\u003c\/p\u003e\n\u003ch3\u003eWhat is this stain used for?\u003c\/h3\u003e\n\u003cp\u003eIt is designed for rapid staining of peripheral blood smears for microscopic demonstration of malaria parasites and other blood-cell structures.\u003c\/p\u003e\n\u003ch3\u003eCan it be used for thin blood smears?\u003c\/h3\u003e\n\u003cp\u003eYes. Biolab provides a dedicated thin-smear staining procedure.\u003c\/p\u003e\n\u003ch3\u003eCan it be used for thick blood smears?\u003c\/h3\u003e\n\u003cp\u003eYes. The IFU also provides a procedure for dehaemoglobinised thick smears.\u003c\/p\u003e\n\u003ch3\u003eDoes it require dilution?\u003c\/h3\u003e\n\u003cp\u003eNo. Biolab describes the JSB reagents as ready to use.\u003c\/p\u003e\n\u003ch3\u003eWhat stains are used?\u003c\/h3\u003e\n\u003cp\u003eThe system is based primarily on polychromated Methylene Blue and Eosin staining.\u003c\/p\u003e\n\u003ch3\u003eHow quickly can a thin smear be stained?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer procedure uses approximately 3–5 seconds in JSB II followed by approximately 35–45 seconds in JSB I, excluding fixation, washing and drying.\u003c\/p\u003e\n\u003ch3\u003eWhy is it called a one-minute malaria stain?\u003c\/h3\u003e\n\u003cp\u003eThe principal stain-contact steps can be completed rapidly, with the combined stain exposure around one minute or less under the manufacturer's procedure. Total workflow time also includes fixation, washing, drying and microscopy.\u003c\/p\u003e\n\u003ch3\u003eHow is a thick smear handled?\u003c\/h3\u003e\n\u003cp\u003eThe Biolab method includes dehaemoglobinisation with distilled water before the rapid staining sequence.\u003c\/p\u003e\n\u003ch3\u003eHow are malaria parasites expected to appear?\u003c\/h3\u003e\n\u003cp\u003eBiolab describes malaria parasites as appearing in varying shades of blue under the specified stain.\u003c\/p\u003e\n\u003ch3\u003eWhat colour are RBCs?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer describes red blood cells as pale reddish.\u003c\/p\u003e\n\u003ch3\u003eWhat colour are leucocyte nuclei?\u003c\/h3\u003e\n\u003cp\u003eThey are described as varying shades of dark blue.\u003c\/p\u003e\n\u003ch3\u003eCan EDTA blood be used?\u003c\/h3\u003e\n\u003cp\u003eYes. Biolab states that EDTA-anticoagulated blood may be used without substantial change in staining results.\u003c\/p\u003e\n\u003ch3\u003eWhat microscope is required?\u003c\/h3\u003e\n\u003cp\u003eThe stained smear is examined using a suitable laboratory microscope under oil immersion according to the manufacturer procedure.\u003c\/p\u003e\n\u003ch3\u003eHow should stain performance be checked?\u003c\/h3\u003e\n\u003cp\u003eBiolab recommends periodic checking using known positive and negative samples.\u003c\/p\u003e\n\u003ch3\u003eHow should the stains be stored?\u003c\/h3\u003e\n\u003cp\u003eThe supplied IFU states approximately 25–35°C. Keep reagents appropriately capped and follow the actual storage instructions printed on the current pack.\u003c\/p\u003e\n\u003ch3\u003eHow long are the reagents stable?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer insert states up to approximately 60 months under prescribed conditions. Always use the printed expiry date on the supplied batch as the final reference.\u003c\/p\u003e\n\u003ch3\u003eCan exhausted stain still be used?\u003c\/h3\u003e\n\u003cp\u003eNo. Biolab advises replacing the stain if prolonged use produces progressively lighter staining.\u003c\/p\u003e\n\u003ch3\u003eCan malaria be ruled out by one negative smear?\u003c\/h3\u003e\n\u003cp\u003eNo. Microscopy sensitivity depends on parasite density, specimen timing, smear quality, staining and examiner expertise. Clinical evaluation and repeat \/ alternative testing may be required.\u003c\/p\u003e\n\u003ch3\u003eIs this suitable for home use?\u003c\/h3\u003e\n\u003cp\u003eNo. This product is intended for trained professional laboratory personnel.\u003c\/p\u003e\n\u003ch3\u003eWhere can I buy Biolab JSB Malaria Stain in Bangalore?\u003c\/h3\u003e\n\u003cp\u003eBiolab Rapid Malaria Stain JSB I \u0026amp; II can be ordered through Microsidd India in RT Nagar, Bengaluru, subject to current stock and batch availability.\u003c\/p\u003e\n\u003ch3\u003eDoes Microsidd supply laboratories outside Bengaluru?\u003c\/h3\u003e\n\u003cp\u003eYes. Microsidd supplies professional laboratory products to serviceable locations across India, subject to stock and courier serviceability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eMedical \u0026amp; Laboratory Disclaimer\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBiolab Rapid Malaria Stain JSB I \u0026amp; II is a professional laboratory staining reagent and should be used only by trained personnel according to the current manufacturer IFU, laboratory SOP, biosafety procedures and microscopy QC requirements.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA stained blood smear is one component of malaria laboratory investigation.\u003c\/p\u003e\n\u003cp\u003eResult quality may be affected by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpecimen timing\u003c\/li\u003e\n\u003cli\u003eParasite density\u003c\/li\u003e\n\u003cli\u003eSmear thickness\u003c\/li\u003e\n\u003cli\u003eFixation\u003c\/li\u003e\n\u003cli\u003eDehaemoglobinisation\u003c\/li\u003e\n\u003cli\u003eStaining time\u003c\/li\u003e\n\u003cli\u003eStain condition\u003c\/li\u003e\n\u003cli\u003eWashing technique\u003c\/li\u003e\n\u003cli\u003eMicroscope optics\u003c\/li\u003e\n\u003cli\u003eOil-immersion technique\u003c\/li\u003e\n\u003cli\u003eOperator experience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA negative microscopy result does not automatically exclude malaria where clinical suspicion remains high.\u003c\/p\u003e\n\u003cp\u003eDiagnostic interpretation and subsequent patient management should be performed by appropriately qualified healthcare and laboratory professionals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eNo Return \/ No Exchange – Verify Method, Pack \u0026amp; Application Before Ordering\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis is a professional laboratory reagent and is method-, application-, storage- and expiry-sensitive.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease verify before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Biolab Diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Rapid Malaria Stain Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod:\u003c\/strong\u003e JSB I \u0026amp; II\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack:\u003c\/strong\u003e 2 × 500 mL main stains\u003c\/li\u003e\n\u003cli\u003eRequired smear type\u003c\/li\u003e\n\u003cli\u003eLaboratory staining method\u003c\/li\u003e\n\u003cli\u003eFixative requirement\u003c\/li\u003e\n\u003cli\u003eCurrent batch and expiry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA correctly supplied reagent cannot normally be returned or exchanged because a different staining method, pack configuration, application or laboratory SOP was required.\u003c\/p\u003e\n\u003cp\u003eLaboratory reagents are storage-sensitive, expiry-sensitive and contamination-sensitive products and cannot normally be returned to saleable stock once correctly delivered.\u003c\/p\u003e\n\u003cp\u003eGenuine cases involving incorrect supply, verified transit damage, materially misdescribed goods or remedies required under applicable Indian law will be handled according to the \u003ca href=\"https:\/\/microsidd.com\/pages\/cancellation-and-refunds\"\u003e\u003cstrong\u003eMicrosidd Refund, Return, Replacement \u0026amp; Cancellation Policy\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn original, continuous, unedited and uncut unboxing video is compulsory for delivery-related claims involving an incorrect, missing or damaged product.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBegin recording before opening the parcel. Open the outer carton carefully by \u003cstrong\u003ecutting the sealing tape with a blade or suitable cutter; do not tear the carton\u003c\/strong\u003e. Keep the courier label, sealed Biolab packaging, reagent bottles, pack configuration, batch and expiry continuously visible.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBiolab Rapid Malaria Stain JSB I \u0026amp; II –  Product Entity Summary\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e Rapid Malaria Stain Kit\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Biolab Diagnostics\u003cbr\u003e\u003cstrong\u003eMethod:\u003c\/strong\u003e JSB I \u0026amp; II Rapid Differential Staining\u003cbr\u003e\u003cstrong\u003ePack:\u003c\/strong\u003e JSB I 500 mL + JSB II 500 mL\u003cbr\u003e\u003cstrong\u003eIFU-Listed Fixative:\u003c\/strong\u003e Easyfix Peripheral Smear Fixative 50 mL; verify current supplied configuration\u003cbr\u003e\u003cstrong\u003ePrimary Application:\u003c\/strong\u003e Malaria Parasite Microscopy\u003cbr\u003e\u003cstrong\u003eSpecimen:\u003c\/strong\u003e Peripheral Blood Smears \/ EDTA Blood\u003cbr\u003e\u003cstrong\u003eSmear Types:\u003c\/strong\u003e Thin \u0026amp; Thick Blood Smears\u003cbr\u003e\u003cstrong\u003eMain Stain Chemistry:\u003c\/strong\u003e Polychromated Methylene Blue \u0026amp; Eosin\u003cbr\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e Ready to Use\u003cbr\u003e\u003cstrong\u003eMicroscopy:\u003c\/strong\u003e Oil Immersion\u003cbr\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e Manufacturer IFU states approximately 25–35°C; verify current pack\u003cbr\u003e\u003cstrong\u003eIntended User:\u003c\/strong\u003e Professional Laboratory Personnel\u003cbr\u003e\u003cstrong\u003eSeller:\u003c\/strong\u003e Microsidd India\u003cbr\u003e\u003cstrong\u003eSeller Location:\u003c\/strong\u003e RT Nagar, Bengaluru, Karnataka, India\u003c\/p\u003e","brand":"Biolab","offers":[{"title":"Default Title","offer_id":68090251968832,"sku":"MALARIA STAIN","price":966.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/8224\/0064\/files\/BiolabRapidMalariaStainKitBox.png?v=1794419732","url":"https:\/\/microsidd.com\/products\/biolab-rapid-malaria-stain-jsb-i-ii-2x500ml","provider":"Microsidd India","version":"1.0","type":"link"}