# Triglycerides Liquid Stable Reagent – 50 ml & 2 × 50 ml | GPO-PAP Method

# Swemed Triglycerides Liquid Stable Reagent

The **Swemed Triglycerides Liquid Stable Reagent** is a professional clinical biochemistry reagent intended for the **quantitative photometric determination of triglycerides** using the **GPO-PAP enzymatic endpoint method**.

It is available in **50 ml and 2 × 50 ml variants** and is suitable for routine lipid-profile testing in pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories.

Swemed identifies Triglycerides as a **GPO-PAP method** assay for serum and plasma specimens, including EDTA and heparin plasma.

The reagent is suitable for compatible **open-system fully automatic and semi-automatic biochemistry analysers** that allow user-programmable assay parameters, subject to analyser compatibility and laboratory validation.

* * *

## Available Pack Sizes

Variant

Pack Size

Swemed Triglycerides Reagent

**50 ml**

Swemed Triglycerides Reagent

**2 × 50 ml**

* * *

# Product at a Glance

Product Detail

Information

Product Name

Triglycerides Liquid Stable Reagent

Brand

Swemed Diagnostics

Available Pack Sizes

**50 ml, 2 × 50 ml**

Test Parameter

Triglycerides

Method

**GPO-PAP**

Test Type

Enzymatic / Photometric

Measurement Mode

Endpoint

Specimen

Serum / Plasma

Plasma Types

EDTA / Heparin

Wavelength

**505 nm**

Temperature

**37°C**

Standard Concentration

**200 mg/dL**

Reagent Volume

**1000 µl**

Sample Volume

**10 µl**

Incubation

**15 minutes at room temperature or 10 minutes at 37°C**

Linearity

**Up to 1000 mg/dL**

Reagent Preparation

Ready to Use

Analyser Compatibility

Open-system Fully Automatic & Semi-Automatic Analysers

Intended Use

Professional In Vitro Diagnostic Use

Seller

Microsidd India

Website

microsidd.com

Location

Bangalore / Bengaluru, Karnataka, India

The wavelength, reagent volume, sample volume, incubation, standard concentration and linearity above are taken from the Swemed technical insert.

* * *

# Key Features

-   **Swemed Diagnostics Triglycerides Reagent**
-   Available in **50 ml and 2 × 50 ml**
-   **GPO-PAP enzymatic method**
-   Ready-to-use reagent
-   Ready-to-use triglyceride standard
-   Endpoint photometric assay
-   Recommended wavelength: **505 nm**
-   Standard concentration: **200 mg/dL**
-   Sample volume: **10 µl**
-   Reagent volume: **1000 µl**
-   Linearity up to **1000 mg/dL**
-   Suitable for serum and compatible plasma samples
-   Suitable for lipid-profile testing
-   Suitable for compatible **open-system fully automatic analysers**
-   Suitable for compatible **open-system semi-automatic analysers**
-   For **professional in vitro diagnostic use only**

* * *

# Key Benefits

## GPO-PAP Enzymatic Method

The Swemed Triglycerides assay uses an enzymatic sequence in which triglycerides are hydrolysed, and subsequent reactions generate hydrogen peroxide. In the presence of peroxidase, a coloured quinoneimine compound is formed, and the intensity of the colour is proportional to the triglyceride concentration in the sample.

## Ready-to-Use Reagent System

The manufacturer technical insert lists both the **Triglyceride Reagent and Triglyceride Standard as ready to use**, helping simplify routine laboratory workflow.

## High Linearity

The assay is stated to be linear up to **1000 mg/dL**, providing a practical analytical range for routine triglyceride testing.

## Open-System Analyser Compatibility

The reagent can be used on compatible **open-system semi-automatic and fully automatic biochemistry analysers** that permit programming of endpoint chemistry parameters such as wavelength, sample volume, reagent volume, temperature and incubation.

## Useful for Routine Lipid Profiles

Triglycerides are commonly measured together with:

-   Total Cholesterol
-   HDL Cholesterol
-   LDL Cholesterol
-   VLDL estimation
-   Other lipid-related parameters

* * *

# Compatible with Open-System Biochemistry Analysers

The **Swemed Triglycerides Reagent** is suitable for use on compatible open-system analysers where laboratories can program the required assay settings.

Analyser Parameter

Swemed Triglycerides Setting

Method

Endpoint

Wavelength

**505 nm**

Temperature

**37°C**

Reagent Volume

**1000 µl**

Sample Volume

**10 µl**

Standard

**200 mg/dL**

Incubation

15 min at room temperature or 10 min at 37°C

Measurement

Against Reagent Blank

Unit

mg/dL

Reaction Direction

Increasing

The laboratory should verify analyser compatibility and validate the programmed application before reporting patient results.

* * *

# Intended Use

The **Swemed Triglycerides Liquid Stable Reagent** is intended for the quantitative determination of triglycerides in serum and suitable plasma specimens by an enzymatic photometric GPO-PAP method.

Swemed lists triglycerides for:

-   Serum
-   Plasma
-   EDTA plasma
-   Heparin plasma

This product is intended for **professional in vitro diagnostic laboratory use only**.

* * *

# Test Principle

Triglycerides are hydrolysed by lipoprotein lipase to form **glycerol and free fatty acids**.

The glycerol undergoes further enzymatic reactions involving glycerol kinase and glycerol phosphate oxidase, producing **hydrogen peroxide**.

In the presence of peroxidase, hydrogen peroxide reacts with the chromogen to form a coloured **quinoneimine compound**.

The intensity of the resulting colour is proportional to the triglyceride concentration in the specimen.

* * *

# Technical Specifications

Test Parameter

Manufacturer Specification

Parameter

Triglycerides

Method

GPO-PAP

Mode

Endpoint

Wavelength

**505 nm**

Temperature

**37°C**

Cuvette

10 mm path length

Measurement

Against Blank

Reagent Volume

**1000 µl**

Sample Volume

**10 µl**

Standard Concentration

**200 mg/dL**

Incubation at Room Temperature

**15 minutes**

Incubation at 37°C

**10 minutes**

Linearity

**1000 mg/dL**

Unit

mg/dL

* * *

# Assay Procedure Summary

Tube

Reagent

Standard / Sample

Blank

1000 µl

—

Standard

1000 µl

10 µl Standard

Test

1000 µl

10 µl Sample

Mix and incubate for:

**15 minutes at room temperature**

or

**10 minutes at 37°C**

Read the absorbance of the standard and test against the reagent blank at **505 nm**.

* * *

# Calculation

**Triglycerides (mg/dL) = Absorbance of Sample ÷ Absorbance of Standard × Concentration of Standard**

The manufacturer states a standard concentration of **200 mg/dL**.

* * *

# Specimen Requirements

The manufacturer recommends:

-   Fresh specimen
-   Clear sample
-   Non-haemolysed serum
-   Fasting patient sample where clinically appropriate

Swemed also notes that blood-collection devices lubricated with **glycerin / glycerol should not be used**, because glycerol can interfere with triglyceride measurement.

* * *

# Specimen Stability

The Swemed technical insert states that triglycerides in serum remain stable for approximately:

Storage Condition

Stability

2–8°C

**3 days**

Prolonged storage at room temperature is discouraged because hydrolysis of glycerol-containing compounds can produce an apparent increase in measured triglycerides.

* * *

# Interfering Substances

Swemed identifies the following as potential interfering substances:

-   Heparin
-   EDTA
-   Fluoride
-   Oxalate
-   Citrate

The insert states these may inhibit the triglyceride assay and should be avoided in the manufacturer procedure. Lipemic or grossly icteric samples may also produce falsely elevated results.

Because Swemed’s broader product listing describes EDTA and heparin plasma as supported sample types, laboratories should follow the **current insert supplied with the actual reagent lot and their validated analyser application** where specimen guidance differs.

* * *

# Measuring Range and Linearity

The Swemed Triglycerides assay is stated to be linear up to:

**1000 mg/dL**

Samples exceeding the validated measuring range should be handled according to the current manufacturer instructions and the laboratory’s validated dilution procedure.

* * *

# Manufacturer Expected Values

The Swemed insert provides the following expected range:

Parameter

Manufacturer Expected Range

Triglycerides

**36–165 mg/dL**

Reference intervals can differ according to population, fasting status, laboratory method and clinical guidelines. Each laboratory should establish or verify an appropriate reference interval for its own patient population.

* * *

# Why Triglycerides Testing Is Important

Triglycerides are esters of fatty acids and glycerol and represent an important form of lipid storage and transport in the body.

Triglyceride testing is commonly used as part of investigations involving:

-   Lipid-profile evaluation
-   Hypertriglyceridaemia
-   Dyslipidaemia
-   Cardiovascular-risk assessment
-   Diabetes mellitus
-   Metabolic disorders
-   Endocrine disturbances
-   Nephrotic conditions
-   Follow-up of lipid-management programmes

Swemed notes that triglyceride testing is useful in the assessment of primary and secondary hyperlipoproteinaemia and may also be relevant in diabetes, nephrosis, biliary obstruction and metabolic abnormalities.

* * *

# Triglycerides in a Lipid Profile

Parameter

Laboratory Relevance

Total Cholesterol

Overall cholesterol measurement

HDL Cholesterol

High-density lipoprotein cholesterol

LDL Cholesterol

Low-density lipoprotein cholesterol

Triglycerides

Circulating triglyceride concentration

VLDL

Often estimated from triglyceride values

* * *

# Who Can Buy This Product?

Buyer Type

Typical Application

Pathology Laboratories

Routine triglyceride testing

Diagnostic Centres

Lipid profile investigations

Hospital Laboratories

Clinical chemistry testing

Cardiology Centres

Lipid and cardiovascular-risk profiles

Diabetes Care Centres

Metabolic and lipid testing

Preventive Health Centres

Routine lipid-profile screening

Clinical Chemistry Laboratories

Routine enzymatic testing

Medical Institutions

Diagnostic and teaching use

Healthcare Organisations

Institutional procurement

Laboratory Distributors

Professional supply where permitted

* * *

# Useful Tips Before Ordering

-   Confirm that **Triglycerides – GPO-PAP Method** is required.
-   Choose the correct pack: **50 ml or 2 × 50 ml**.
-   Confirm your analyser is an **open system** before programming third-party reagents.
-   Ensure the analyser supports **505 nm endpoint measurement**.
-   Confirm 1000 µl reagent and 10 µl sample programming.
-   Verify the standard concentration: **200 mg/dL**.
-   Follow current manufacturer instructions for sample type.
-   Use fresh and properly handled specimens.
-   Avoid glycerol-contaminated sample-collection equipment.
-   Perform calibration and internal quality control before routine use.
-   Verify analyser application and method performance before reporting patient results.

* * *

# Buy Swemed Triglycerides Reagent in Bangalore

Microsidd India supplies **lipid-profile reagents, clinical chemistry reagents and laboratory products from Bangalore / Bengaluru, Karnataka**.

The **Swemed Triglycerides Liquid Stable Reagent** is available in **50 ml and 2 × 50 ml pack variants** and is suitable for pathology laboratories, diagnostic centres, hospitals and clinical chemistry facilities using compatible open-system analysers.

The product can be ordered through **microsidd.com**, subject to stock availability and serviceability.

* * *

# Search Relevance

This product is relevant for buyers searching for:

-   Triglycerides reagent supplier in Bangalore
-   Swemed Triglycerides Reagent Bangalore
-   Triglycerides GPO PAP reagent Bengaluru
-   Triglyceride reagent 50 ml
-   Triglycerides reagent 2 × 50 ml
-   Lipid profile reagent supplier Bangalore
-   Triglyceride reagent for semi auto analyser
-   Triglycerides reagent for fully automatic analyser
-   Open system biochemistry reagent Bangalore
-   Clinical chemistry reagent supplier near me
-   Pathology lab reagent supplier Bangalore
-   Swemed Triglycerides reagent online India

* * *

# Product Summary

### What is Swemed Triglycerides Liquid Stable Reagent?

The **Swemed Triglycerides Liquid Stable Reagent** is a ready-to-use professional clinical chemistry reagent for quantitative triglyceride estimation using the **GPO-PAP enzymatic endpoint method**.

### Which pack sizes are available?

-   **50 ml**
-   **2 × 50 ml**

### Which method is used?

The assay uses the **GPO-PAP method**.

### What wavelength is required?

The manufacturer specifies **505 nm**.

### What is the sample volume?

The assay uses **10 µl sample**.

### What is the reagent volume?

The assay uses **1000 µl reagent**.

### What is the triglyceride standard concentration?

The manufacturer insert specifies **200 mg/dL**.

### What is the linearity?

The stated linearity is **1000 mg/dL**.

### Is the reagent ready to use?

Yes. The manufacturer lists both reagent and standard as **ready to use**.

### Is it suitable for semi-automatic analysers?

Yes, for compatible **open-system semi-automatic biochemistry analysers** after application programming and method validation.

### Is it suitable for fully automatic analysers?

Yes, for compatible **open-system fully automatic biochemistry analysers** that permit third-party reagent programming, subject to analyser compatibility and laboratory validation.

### Where can it be purchased?

The product can be ordered from **Microsidd India through microsidd.com**, subject to availability.

* * *

# Entity Information

Entity

Details

Product

Triglycerides Liquid Stable Reagent

Brand

Swemed Diagnostics

Pack Sizes

50 ml / 2 × 50 ml

Analyte

Triglycerides

Method

GPO-PAP

Test Type

Enzymatic Photometric Endpoint

Wavelength

505 nm

Standard

200 mg/dL

Specimen

Serum / Plasma

Category

Laboratory Reagents

Subcategory

Biochemistry Reagents

Clinical Category

Lipid Profile

Analyser Compatibility

Open-System Fully Automatic & Semi-Automatic Biochemistry Analysers

Seller

Microsidd India

City

Bangalore / Bengaluru

State

Karnataka

Country

India

Website

microsidd.com

Buyer Type

Laboratory / Hospital / Diagnostic Centre / B2B

  

# Why Buy Swemed Triglycerides Reagent from Microsidd.com?

Lipid-profile reagents require careful procurement because laboratories need to verify the **correct method, pack size, analyser compatibility, standard concentration, storage conditions, expiry and seller source**.

Microsidd India has long-standing experience in the **IVD and diagnostic-products sector** and focuses specifically on laboratory, diagnostic and healthcare products. This gives professional buyers an identifiable specialist procurement source instead of relying only on general marketplace listings.

# Microsidd.com vs Online Marketplaces vs Offline Suppliers

Buying Factor

Microsidd.com

Large Online Marketplaces

Offline / Local Suppliers

Seller Specialisation

Diagnostic and laboratory focused

Seller expertise varies

Depends on dealer

Product Understanding

Better suited to reagent-specific enquiries

Often general marketplace support

Dealer dependent

Seller Identity

Direct purchase from Microsidd India

Marketplace and actual seller may differ

Usually locally identifiable

Pack Verification

50 ml / 2 × 50 ml can be confirmed before ordering

Similar listings may cause confusion

Depends on local stock

Method Verification

GPO-PAP can be confirmed

Seller dependent

Dealer dependent

Analyser Compatibility Support

Better suited to open-system analyser queries

Often limited

Depends on supplier knowledge

GST Invoice

Available for eligible purchases

Seller dependent

May vary

B2B Procurement

Suitable for labs, hospitals and institutions

Seller dependent

Usually local

Product Range

Specialist diagnostic and laboratory catalogue

Broad but not specialised

Usually limited

Customer Support

Direct Microsidd support

Marketplace plus seller layer

Local support

Accountability

One identifiable specialist supplier

Seller may vary by listing

Depends on supplier

India-Wide Supply

Subject to serviceability

Broad

Usually regional

# Benefits of Buying from Microsidd.com

Microsidd Advantage

Benefit to Laboratory Buyers

Diagnostic Product Specialisation

Better understanding of professional laboratory procurement

Long-Standing IVD Experience

Familiarity with clinical chemistry requirements

Direct Seller Accountability

Purchase directly from Microsidd India

Product Verification

Method and pack variants can be checked before purchase

Open-System Analyser Support

Easier verification of programmable settings

GST Invoice

Useful for professional and institutional procurement

Multi-Category Procurement

Lipid, liver, renal and cardiac reagents can be sourced together

Bangalore-Based Operations

Convenient for Bengaluru and Karnataka laboratories

India-Wide Supply

Delivery to serviceable locations across India

Direct Customer Support

Product and order-related queries handled directly

# Frequently Asked Questions

### What is Swemed Triglycerides Reagent used for?

It is used for quantitative determination of **triglycerides in serum/plasma** by the GPO-PAP method.

### What pack sizes are available?

The product is available in **50 ml and 2 × 50 ml variants**.

### What method does the reagent use?

It uses the **GPO-PAP enzymatic method**.

### What wavelength is used?

The assay is read at **505 nm**.

### What is the standard concentration?

The standard concentration is **200 mg/dL**.

### What is the sample volume?

The assay uses **10 µl sample**.

### What is the reagent volume?

The assay uses **1000 µl reagent**.

### What is the incubation time?

Swemed specifies **15 minutes at room temperature or 10 minutes at 37°C**.

### What is the linearity?

The assay is linear up to **1000 mg/dL**.

### Is the reagent ready to use?

Yes. Swemed identifies both the reagent and standard as **ready to use**.

### Can it be used on semi-automatic biochemistry analysers?

Yes, on compatible **open-system semi-automatic analysers** after programming and method validation.

### Can it be used on fully automatic biochemistry analysers?

Yes, on compatible **open-system fully automatic analysers** that allow third-party reagent programming.

### Is this product for home testing?

No. It is intended for **professional in vitro diagnostic use only**.

### Where can I buy Swemed Triglycerides Reagent in Bangalore?

The product can be ordered through **Microsidd India at microsidd.com**, subject to stock availability.

# Medical and Laboratory Disclaimer

The information on this product page is provided for **general product identification, procurement and laboratory educational purposes only**.

This product is intended for **professional in vitro diagnostic use by trained laboratory personnel**.

Triglyceride results should not be interpreted independently to diagnose or exclude cardiovascular disease, diabetes, metabolic disease or any other condition. Clinical interpretation should consider fasting status, total cholesterol, HDL, LDL, patient history and other relevant investigations.

The information provided by Microsidd India does not replace the current Swemed Diagnostics package insert, analyser instructions, laboratory SOPs, calibration requirements, internal quality-control procedures or professional medical judgement.

For open-system fully automatic and semi-automatic analysers, **compatibility and application parameters must be programmed and validated by the laboratory before routine clinical use**.

Where older and newer manufacturer documents differ in specimen handling or pack configurations, the **current label and package insert supplied with the actual reagent lot should be treated as the definitive specification**.

# No Return / No Exchange Policy

**This product is non-returnable and non-exchangeable.**

Please verify the **brand, model, compatibility, pack size and product specifications before placing your order**.

For laboratory reagents, customers should specifically verify the **test parameter, methodology, analyser compatibility, reagent configuration and pack size** before ordering.

Genuine cases involving an **incorrect product received** will be handled separately according to Microsidd.com's applicable policies and applicable law.

**An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.**

## Details

- **Price:** 1800.0 INR - 3499.0 INR
- **Vendor:** Swemed Diagnostics
- **Type:** Biochemistry Reagents
- **Tags:** Bio Chemistry Reagents, biochemistry

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| 50ml | 1800.00 INR | In stock |
| 100ml | 3499.00 INR | In stock |

## Images

- Swemed Triglycerides Reagent 50ml & 2x50ml GPO-PAP Microsidd
- Swemed Triglycerides Reagent 50ml & 2x50ml GPO-PAP Microsidd
- Swemed Triglycerides Reagent 50ml & 2x50ml GPO-PAP Microsidd
- Swemed Triglycerides Reagent 50ml & 2x50ml GPO-PAP Microsidd
- Swemed Triglycerides Reagent 50ml & 2x50ml GPO-PAP Microsidd

---

> Source: [Microsidd India](https://microsidd.com/products/triglycerides-liquid-stable-reagent)
> Updated: 2026-09-14
