# Syringe Pump ICU

# **ICU Syringe Pump**

  

## ICU syringe pump

  

Model: SP301

  

Long run time battery with 12 Hours battery backup

  

Fast start function against start delay

  

Intuitive Keypad with Keypad locking system

  

With parameters enlarge function

  

DPS (Dynamic Pressure show)

  

### **Unique Voice Alarm system** syringe pump device triggered the voice prompt and stop injection automatically when there is any malfunction, making  
the infusion process safer and more reliable.

  

### **Rechargeable lithium battery**

  

**2.8 inches TFT Display**

  

**5ml - 60ml syringe support**

  

### **flow rate**  
50ml syringe:0.1~1500ml/h;  
30ml syringe:0.1~900.0ml/h;  
20ml syringe:0.1~600.0ml/h;  
10ml syringe:0.1~300.0ml/h

  

the range of limiting volume 0~999.9ml

  

the range of injected volume 0~9999.9ml

  

**accuracy of flow rate**

  

Within ±3% (Choose the syringe of specified manufacturer   
correctly.  
This accuracy of flow rate is not including the errors of syringe   
itself.)

  

**purge rate**  
Purge rate of 50ml syringe:1500ml/h;  
Purge rate of 30ml syringe:900.0ml/h;  
Purge rate of 20ml syringe:600.0ml/h;  
Purge rate of 10ml syringe:300.0ml/h

  

**alarm & warms**  
The pump can give out alarming when injection soon finish,  
injection finishing, injection of limited amount finished,  
injection is blocked, syringe falls off, syringe is improperly   
installed, setting error, AC power has been pulled out,  
low battery and so on.

  

**injection blocked**  
Choose in the three kinds of occlusion alarm pressure  
according to the clinical requirements(High,Medium,Low)

  

KVO rate 1ml/h

  

**fuse specification**  
F1AL/250V ,two fuses(installed inside pump)

  

**operating power**  
AC100~240.0V, 50/60Hz, Power:=30VA  
Internal rechargeable battery: DC 11.1V,capacity=1600mAh.  
The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.

  

**operating environment**  
temperature:+5~+40°C, relative humidity:20~90%

  

**storing environment**  
temperature:-30°C~+55, relative humidity:=95%, ( No condensation state )

  

atmospheric pressure 860hPa~1060hPa

  

**safety level**  
Class II with insulated enclosure, internal power supply,  
BF-type continuous normal running equipment.

  

**IP grade IPX1**

  

**dimensions 280(L)×210(W)×130(H)(mm)**

  

**weight 2.2kg**

  

**accessories** Power line,operating manual,warranty card,product certification.

## Details

- **Price:** 25999.0 INR
- **Vendor:** SCURE™
- **Tags:** Syringe Pump

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 25999.00 INR | In stock |

## Images

- images

---

> Source: [Microsidd India](https://microsidd.com/products/syringe-pump-icu)