# Meril MeriLisa HIV 1-2 Gen 3 ELISA Kit – 96 Tests

## MeriLisa HIV 1-2 Gen 3 ELISA Kit for Professional HIV Antibody Screening

The **Meril MeriLisa HIV 1-2 Gen 3 ELISA Kit – 96 Tests** is a professional in-vitro diagnostic enzyme immunoassay designed for the **qualitative detection of antibodies against Human Immunodeficiency Virus Type 1 (HIV-1) and Type 2 (HIV-2) in human serum or plasma**.

This **third-generation HIV ELISA** is designed to detect multiple antibody classes, including **IgM, IgG and IgA antibodies**, helping professional laboratories perform HIV antibody screening using a standard ELISA workflow.

The MeriLisa HIV 1-2 Gen 3 kit is supplied in a **96-test laboratory format** and is intended for appropriately trained laboratory, Blood banks and healthcare professionals.

* * *

# Product Information

**Brand:** Meril Diagnostics  
**Product Family:** MeriLisa  
**Product Name:** MeriLisa HIV 1-2 Gen 3 ELISA Kit  
**Manufacturer Product Code:** HV3ELI-01  
**Category:** Laboratory Reagents & Kits / Blood Bank Kits  
**Subcategory:** ELISA / Infectious Disease Diagnostics  
**Test Type:** HIV 1 & HIV 2 Antibody ELISA  
**Generation:** 3rd Generation  
**Technology:** Enzyme-Linked Immunosorbent Assay – ELISA  
**Assay Principle:** Antibody Capture Sandwich ELISA  
**Detection:** Anti-HIV-1 and Anti-HIV-2 antibodies  
**Antibody Classes Detected:** IgM, IgG and IgA  
**HIV Antigens Used:** Recombinant gp120, gp41 and gp36 antigens  
**Subtype Coverage:** Includes HIV-1 subtype O and subtype C according to manufacturer information  
**Specimen Type:** Human Serum / Plasma  
**Result Type:** Qualitative – Reactive / Non-Reactive according to assay interpretation criteria  
**Pack Size:** 96 Tests  
**Approximate Assay Time:** 90 Minutes  
**Storage:** 2–8°C refrigerated  
**Intended Use:** Professional In-Vitro Diagnostic Use  
**Suitable Users:** Diagnostic laboratories, hospitals, blood banks and appropriately trained laboratory professionals  
**Seller:** Microsidd India  
**Location:** RT Nagar, Bengaluru, Karnataka, India

* * *

# What Is MeriLisa HIV 1-2 Gen 3?

**MeriLisa HIV 1-2 Gen 3** is a third-generation HIV ELISA system used for qualitative detection of antibodies produced against HIV-1 and HIV-2.

Unlike a fourth-generation HIV assay, which may detect both **HIV antibodies and p24 antigen**, this third-generation product is an **antibody-detection assay**.

The use of a third-generation assay enables detection of different HIV antibody classes, including **IgM, IgG and IgA**, which is an important distinction from older antibody-only assay formats.

The assay uses recombinant HIV antigens including:

-   HIV-1 gp120
-   HIV-1 gp41
-   HIV-2 gp36

These antigens are used within the ELISA system to detect antibodies directed against HIV-1 and HIV-2.

* * *

# What Does the Kit Detect?

The MeriLisa HIV 1-2 Gen 3 kit is intended to detect:

**Antibodies against HIV-1**

and

**Antibodies against HIV-2**

The manufacturer also identifies detection of **HIV-1 subtype O and subtype C** within the assay's stated coverage.

This kit does **not** represent an HIV p24 antigen test and should not be described as a fourth-generation antigen-antibody assay.

* * *

# Key Product Features

### Third-Generation HIV ELISA

The assay uses a third-generation ELISA format designed to detect multiple HIV antibody classes.

### Detection of HIV-1 & HIV-2 Antibodies

Designed for professional qualitative testing for antibodies against both major HIV types.

### Detects IgM, IgG & IgA

Detection of multiple antibody classes distinguishes this assay from earlier-generation antibody tests.

### Recombinant HIV Antigens

The assay incorporates recombinant HIV antigens including **gp120, gp41 and gp36**.

### Subtype Coverage

Manufacturer information states detection of HIV-1 subtype **O and C** in addition to standard HIV-1/HIV-2 antibody detection.

### 96-Test Laboratory Format

Designed for batch testing in professional ELISA laboratories.

### Approximately 90-Minute Assay

Manufacturer literature lists an approximate assay time of **90 minutes**.

### Suitable for Standard ELISA Laboratory Workflow

Designed for use with appropriate ELISA microplate processing, washing and reading equipment according to the current manufacturer's IFU.

### Professional IVD Product

This is not a home HIV self-test or rapid card test.

* * *

# Manufacturer-Reported Performance

According to the manufacturer's stated evaluation data:

Parameter

Manufacturer-Stated Performance

Diagnostic Sensitivity

100%

Diagnostic Specificity

\>99.5%

Assay Time

Approx. 90 Minutes

Pack Format

96 Tests

Generation

3rd Generation

HIV Types

HIV-1 & HIV-2

Antibody Classes

IgM, IgG & IgA

Performance figures apply to the manufacturer's stated evaluation conditions and should not be interpreted as a guarantee for every specimen or laboratory environment.

* * *

# Benefits of MeriLisa HIV 1-2 Gen 3

The 96-test ELISA configuration provides several practical benefits for professional laboratories.

It allows multiple patient samples to be processed within a controlled ELISA workflow, making it useful for laboratories performing regular HIV antibody screening.

The third-generation format detects multiple antibody classes and uses recombinant HIV antigens, while the plate-based format is suitable for laboratories already equipped with compatible ELISA readers, washers and associated laboratory equipment.

The larger batch format may also be more practical than individual rapid tests for laboratories processing multiple specimens together.

* * *

# Who Can Use This Product?

The MeriLisa HIV 1-2 Gen 3 ELISA Kit is intended for **trained professional users**, including:

-   Diagnostic laboratories
-   Pathology laboratories
-   Hospital laboratories
-   Blood bank laboratories
-   Clinical microbiology laboratories
-   Serology laboratories
-   Medical colleges and teaching laboratories
-   Government and institutional testing laboratories
-   Trained laboratory technicians
-   Microbiologists
-   Pathologists
-   Other appropriately qualified healthcare professionals

**This product is not intended for unsupervised home testing or consumer self-testing.**

* * *

# Suitable Laboratory Applications

The MeriLisa HIV ELISA may be incorporated into professional laboratory workflows for:

-   HIV antibody screening
-   HIV-1 and HIV-2 serological testing
-   Institutional screening programs
-   Hospital laboratory testing
-   Blood-bank screening where permitted under applicable protocols
-   Serological surveillance programs
-   Diagnostic laboratory workflows
-   Professional testing conducted according to approved HIV testing algorithms

The kit should always be used according to the current manufacturer IFU and applicable national/institutional testing protocol.

* * *

# How the Assay Works

MeriLisa HIV 1-2 Gen 3 uses an ELISA-based antigen-antibody reaction.

Recombinant HIV antigens are incorporated into the test system.

If antibodies against HIV-1 or HIV-2 are present in the patient's serum or plasma, they bind to the relevant HIV antigens during the assay.

Subsequent enzyme-linked reaction steps produce a measurable colour signal.

The optical density is measured using a compatible ELISA microplate reader, and results are interpreted using the manufacturer's prescribed cut-off calculation and assay validity criteria.

Exact sample volumes, incubation conditions, wash cycles, wavelength, cut-off calculations and control requirements should be taken from the **current Meril Instructions for Use**, not from a generic online protocol.

* * *

# Technical Specifications

Specification

Details

**Brand**

Meril Diagnostics

**Product**

MeriLisa HIV 1-2 Gen 3

**Product Code**

HV3ELI-01

**Category**

HIV ELISA Kit

**Generation**

Third Generation

**Technique**

ELISA

**Principle**

Antibody Capture Sandwich Assay

**Detection**

HIV-1 & HIV-2 Antibodies

**Antibody Classes**

IgM, IgG & IgA

**Relevant Antigens**

gp120, gp41, gp36

**Specimens**

Human Serum / Plasma

**Result**

Qualitative

**Pack Size**

96 Tests

**Assay Time**

Approx. 90 Minutes

**Storage**

2–8°C

**Use**

Professional IVD

* * *

# 3rd Generation vs 4th Generation HIV ELISA

Feature

MeriLisa HIV 1-2 Gen 3

HIV 4th Generation ELISA

HIV-1 Antibody

Yes

Yes

HIV-2 Antibody

Yes

Yes

IgM Detection

Yes

Yes

IgG Detection

Yes

Yes

p24 Antigen Detection

No

Yes

Test Type

Antibody ELISA

Antigen + Antibody ELISA

Laboratory Format

ELISA

ELISA

This distinction is important when laboratories select the correct HIV assay.

A **third-generation kit should not be represented as a p24 antigen test**.

* * *

# Pack Size & Test Capacity

**Pack Size:** 96 Tests

A 96-test ELISA kit is supplied in a microplate-based laboratory format.

The term **96 tests** refers to the manufacturer's kit configuration. The actual number of patient specimens that can be processed in a run may be lower because wells are also required for positive controls, negative controls, blanks or other assay requirements.

Laboratories should therefore calculate usable patient capacity according to the manufacturer's plate layout and their validated SOP.

* * *

# Equipment Typically Required

The MeriLisa HIV ELISA assay is intended for use within a suitably equipped ELISA laboratory.

Depending on the validated laboratory workflow, equipment may include:

-   ELISA microplate reader
-   Microplate washer or validated manual washing system
-   Calibrated micropipettes
-   Appropriate pipette tips
-   Incubation equipment
-   Timer
-   Laboratory PPE
-   Appropriate specimen-handling equipment

Specific reader wavelength and operating parameters must follow the current kit IFU.

* * *

# Storage

Store the MeriLisa HIV 1-2 Gen 3 kit under **refrigerated conditions at 2–8°C**.

For proper reagent handling:

-   Maintain refrigerated storage at 2–8°C.
-   Keep reagents tightly closed when not in use.
-   Protect the kit from inappropriate heat exposure.
-   Avoid contamination between reagents.
-   Return reagents promptly to recommended storage after use.
-   Do not use the kit after the expiry date printed on the supplied pack.
-   Do not use deteriorated or visibly contaminated reagents.
-   Follow the storage information printed on the current supplied kit.

**The manufacturer's current pack label and Instructions for Use always take precedence over general website information.**

* * *

# Transportation & Cold-Chain Handling

For professional laboratory supply:

-   Transport under appropriate refrigerated conditions.
-   Protect the kit from excessive heat.
-   Avoid prolonged exposure outside the manufacturer's labelled storage range.
-   Avoid freezing unless expressly permitted by the current manufacturer IFU.
-   Inspect the shipment promptly upon receipt.
-   Check the kit name, lot number, expiry and physical condition.
-   Transfer the kit promptly to suitable **2–8°C refrigeration**.
-   Follow your laboratory's cold-chain receiving SOP.

For urgent institutional requirements, customers should confirm dispatch and transport arrangements before ordering.

* * *

# Important HIV Testing Information

A **reactive HIV screening result should not be interpreted in isolation as a final HIV diagnosis**.

HIV testing must be performed according to the applicable testing algorithm, using appropriate repeat or supplemental testing where required.

Laboratories should follow:

-   Manufacturer Instructions for Use
-   Laboratory SOPs
-   Quality-control requirements
-   Applicable national HIV testing guidelines
-   Institutional reporting procedures

Clinical decisions should only be made by appropriately qualified healthcare professionals.

* * *

# Related ELISA & Laboratory Products

### Explore the Microsidd ELISA Range

Browse professional ELISA kits for HIV, HCV, HBsAg, Dengue and other laboratory parameters:

**[https://microsidd.com/collections/elisa-range](https://microsidd.com/collections/elisa-range?utm_source=chatgpt.com)**

### Explore Laboratory Reagents & Kits

Browse a wider range of professional laboratory reagents:

**[https://microsidd.com/collections/chemicals-liquids](https://microsidd.com/collections/chemicals-liquids?utm_source=chatgpt.com)**

As we optimise the remaining ELISA products, I recommend creating direct internal links between:

**MeriLisa HIV → MeriLisa HCV → MeriLisa HBsAg → HIV 4th Generation ELISA → ELISA Range**

This will create a much stronger infectious-disease ELISA topic cluster for Google and AI systems.

* * *

# Why Buy MeriLisa HIV ELISA from Microsidd?

Microsidd India supplies professional diagnostic products, laboratory reagents and medical consumables from Bengaluru to healthcare and laboratory customers across serviceable locations in India.

Benefits of ordering from Microsidd include:

✓ Professional laboratory-focused product catalogue  
✓ HIV, HCV, HBsAg and other ELISA products available  
✓ Clear identification of assay generation and pack size  
✓ Technical product information before purchase  
✓ Related ELISA and laboratory products available  
✓ GST invoice where applicable  
✓ Bengaluru-based customer support  
✓ Supply to serviceable locations across India  
✓ Institutional and laboratory requirements supported subject to stock  
✓ Temperature-sensitive reagent handling considerations clearly communicated

* * *

# Buy HIV ELISA Kit in Bangalore / Bengaluru

Microsidd India supplies professional **HIV ELISA kits in Bengaluru** as part of its laboratory diagnostics range.

Laboratories searching for:

**HIV ELISA kit Bangalore**  
**HIV 1 2 ELISA kit Bengaluru**  
**MeriLisa HIV kit Bangalore**  
**96 test HIV ELISA kit**  
**HIV laboratory reagent near me**

can order through Microsidd.com subject to availability, professional-use requirements and serviceability.

This local section is sufficient for local SEO; there is no need to repeatedly insert Bangalore/Bengaluru throughout the description.

* * *

# Microsidd India

**Business Name:** Microsidd India  
**Address:** #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, India  
**Phone / WhatsApp:** +91 63667 72288  
**Email:** [support@microsidd.com](mailto:support@microsidd.com)  
**Website:** [https://microsidd.com](https://microsidd.com?utm_source=chatgpt.com)  
**Working Hours:** Monday to Saturday, 10:00 AM – 6:00 PM IST

### Find Microsidd India on Google Maps

[https://www.google.com/maps/search/?api=1&query=Microsidd+India%2C+09+Green+Chambers%2C+14th+Cross%2C+RT+Nagar%2C+Bengaluru+560032](https://www.google.com/maps/search/?api=1&query=Microsidd+India%2C+09+Green+Chambers%2C+14th+Cross%2C+RT+Nagar%2C+Bengaluru+560032)

* * *

# Stay Connected with Microsidd

## Subscribe to Microsidd on YouTube

Watch product explainers, laboratory-product information, diagnostic guides and healthcare videos.

**Subscribe here:**

[https://www.youtube.com/channel/UCun9gCID17Z5kK65W6JtIdg?sub\_confirmation=1](https://www.youtube.com/channel/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1)

## Follow the Microsidd WhatsApp Channel

Get updates about new products, laboratory supplies, offers and useful diagnostic-product information.

**Join the Microsidd WhatsApp Channel:**

[https://whatsapp.com/channel/0029Va5lCoi1nozBZBL1gx3P](https://whatsapp.com/channel/0029Va5lCoi1nozBZBL1gx3P)

* * *

# Frequently Asked Questions

### What is MeriLisa HIV 1-2 Gen 3?

MeriLisa HIV 1-2 Gen 3 is a professional third-generation ELISA kit for qualitative detection of antibodies against HIV-1 and HIV-2 in human serum or plasma.

### What is the Meril product code?

The 96-test configuration is **HV3ELI-01**.

### What is the pack size?

The kit is supplied in a **96-test format**.

### Is this a 3rd-generation HIV test?

Yes. This product is a **third-generation HIV antibody ELISA**.

### Does it detect HIV-1 and HIV-2?

Yes. It is designed to detect antibodies against both HIV-1 and HIV-2.

### Which antibody classes can it detect?

The manufacturer describes detection of **IgM, IgG and IgA antibodies** against HIV-1 and HIV-2.

### Does it detect HIV p24 antigen?

No. MeriLisa HIV 1-2 Gen 3 is an antibody assay.

A **fourth-generation HIV ELISA** is required when the test system is designed for combined HIV antibody and p24 antigen detection.

### Which HIV antigens are used in the assay?

Manufacturer information identifies recombinant **gp120 and gp41 for HIV-1 and gp36 for HIV-2**.

### Does it cover HIV subtype O?

Yes. Manufacturer information identifies coverage of subtype O.

### Does it cover subtype C?

Yes. Manufacturer information also identifies subtype C detection.

### What samples are used?

The assay is intended for **human serum or plasma** according to the current manufacturer IFU.

### How long does the assay take?

Manufacturer information lists approximately **90 minutes**.

### What is the manufacturer-stated sensitivity?

The manufacturer reports **100% diagnostic sensitivity** under its stated evaluation conditions.

### What is the manufacturer-stated specificity?

The manufacturer reports **greater than 99.5% diagnostic specificity** under its stated evaluation conditions.

### Does 96 tests mean 96 patient samples?

Not necessarily.

Some wells are normally required for controls, blanks or assay-validity requirements, so actual patient-sample capacity depends on the validated plate layout.

### Can this test be used at home?

No. This is a **professional ELISA laboratory kit**.

### Is an ELISA reader required?

A compatible ELISA microplate-reading system and other laboratory equipment are required according to the manufacturer's assay protocol.

### Can this kit be used in a blood bank?

It may be incorporated into professional HIV screening workflows where permitted by applicable blood-bank protocols, manufacturer intended use and regulatory requirements.

### Is one reactive result enough to diagnose HIV?

No.

A reactive screening result must be managed according to the applicable HIV testing algorithm and laboratory protocol. A single reactive screening assay should not independently be treated as a final diagnosis.

### How should the kit be stored?

Store at **2–8°C refrigerated**, following the conditions stated on the current supplied pack.

### Does this product require cold-chain transport?

Because refrigerated storage is required, transportation should maintain suitable temperature conditions consistent with the product's labelled requirements.

### Can the kit be frozen?

Avoid freezing unless the current manufacturer Instructions for Use specifically permit it.

### Is this the same as a rapid HIV card?

No.

MeriLisa is a **laboratory ELISA system**. Rapid HIV cards use a different test format and workflow.

### Where can I see other ELISA kits?

Browse the Microsidd ELISA collection:

[https://microsidd.com/collections/elisa-range](https://microsidd.com/collections/elisa-range?utm_source=chatgpt.com) 

[https://microsidd.com/collections/blood-bank-range](https://microsidd.com/collections/blood-bank-range "Buy Hiv Elisa 96Test kit on Microsidd.com ")

* * *

# No Return / No Exchange Policy

**This product is non-returnable and non-exchangeable.**

Please verify the **brand, test generation, test parameter, methodology, specimen requirement, laboratory-equipment compatibility, pack size, storage requirement and product specifications before placing your order**.

For laboratory reagents, customers should specifically verify the **test parameter, methodology, analyser or equipment compatibility, reagent configuration and pack size** before ordering.

Genuine cases involving an **incorrect product received** will be handled separately according to Microsidd.com's applicable policies and applicable law.

**An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received.**

* * *

# Professional / Medical Disclaimer

The **Meril MeriLisa HIV 1-2 Gen 3 ELISA Kit is intended for professional in-vitro diagnostic use only**.

Testing must be performed by appropriately trained laboratory personnel according to the manufacturer's current Instructions for Use, laboratory SOPs, quality-control procedures and applicable national or institutional HIV testing guidelines.

A reactive HIV screening result is not, by itself, a final diagnosis. Reactive or discordant results must be handled according to the applicable HIV testing algorithm and interpreted by qualified healthcare professionals.

The product is not intended for unsupervised home testing, self-diagnosis or self-treatment

## Details

- **Price:** 2499.0 INR
- **Vendor:** MERIL DIAGNOSTICS
- **Type:** HIV Elisa Kit
- **Tags:** Elisa Range

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 2499.00 INR | In stock |

## Images

- Meril MeriLisa HIV 1-2 Gen 3 ELISA 96 Tests Microsidd
- Meril MeriLisa HIV 1-2 Gen 3 ELISA 96 Tests Microsidd
- Meril MeriLisa HIV 1-2 Gen 3 ELISA 96 Tests Microsidd
- Meril MeriLisa HIV 1-2 Gen 3 ELISA 96 Tests Microsidd
- Meril MeriLisa HIV 1-2 Gen 3 ELISA 96 Tests Microsidd

---

> Source: [Microsidd India](https://microsidd.com/products/merilisa-hiv-96t-pack)
> Updated: 2026-09-26
