# Title: Triglycerides Liquid Stable Reagent – 50 ml & 2 × 50 ml | GPO-PAP Method ## Description: Swemed Triglycerides Liquid Stable Reagent The Swemed Triglycerides Liquid Stable Reagent is a professional clinical biochemistry reagent intended for the quantitative photometric determination of triglycerides using the GPO-PAP enzymatic endpoint method. It is available in 50 ml and 2 × 50 ml variants and is suitable for routine lipid-profile testing in pathology laboratories, diagnostic centres, hospitals and clinical chemistry laboratories. Swemed identifies Triglycerides as a GPO-PAP method assay for serum and plasma specimens, including EDTA and heparin plasma. The reagent is suitable for compatible open-system fully automatic and semi-automatic biochemistry analysers that allow user-programmable assay parameters, subject to analyser compatibility and laboratory validation. Available Pack Sizes Variant Pack Size Swemed Triglycerides Reagent 50 ml Swemed Triglycerides Reagent 2 × 50 ml Product at a Glance Product Detail Information Product Name Triglycerides Liquid Stable Reagent Brand Swemed Diagnostics Available Pack Sizes 50 ml, 2 × 50 ml Test Parameter Triglycerides Method GPO-PAP Test Type Enzymatic / Photometric Measurement Mode Endpoint Specimen Serum / Plasma Plasma Types EDTA / Heparin Wavelength 505 nm Temperature 37°C Standard Concentration 200 mg/dL Reagent Volume 1000 µl Sample Volume 10 µl Incubation 15 minutes at room temperature or 10 minutes at 37°C Linearity Up to 1000 mg/dL Reagent Preparation Ready to Use Analyser Compatibility Open-system Fully Automatic & Semi-Automatic Analysers Intended Use Professional In Vitro Diagnostic Use Seller Microsidd India Website microsidd.com Location Bangalore / Bengaluru, Karnataka, India The wavelength, reagent volume, sample volume, incubation, standard concentration and linearity above are taken from the Swemed technical insert. Key Features Swemed Diagnostics Triglycerides Reagent Available in 50 ml and 2 × 50 ml GPO-PAP enzymatic method Ready-to-use reagent Ready-to-use triglyceride standard Endpoint photometric assay Recommended wavelength: 505 nm Standard concentration: 200 mg/dL Sample volume: 10 µl Reagent volume: 1000 µl Linearity up to 1000 mg/dL Suitable for serum and compatible plasma samples Suitable for lipid-profile testing Suitable for compatible open-system fully automatic analysers Suitable for compatible open-system semi-automatic analysers For professional in vitro diagnostic use only Key Benefits GPO-PAP Enzymatic Method The Swemed Triglycerides assay uses an enzymatic sequence in which triglycerides are hydrolysed, and subsequent reactions generate hydrogen peroxide. In the presence of peroxidase, a coloured quinoneimine compound is formed, and the intensity of the colour is proportional to the triglyceride concentration in the sample. Ready-to-Use Reagent System The manufacturer technical insert lists both the Triglyceride Reagent and Triglyceride Standard as ready to use, helping simplify routine laboratory workflow. High Linearity The assay is stated to be linear up to 1000 mg/dL, providing a practical analytical range for routine triglyceride testing. Open-System Analyser Compatibility The reagent can be used on compatible open-system semi-automatic and fully automatic biochemistry analysers that permit programming of endpoint chemistry parameters such as wavelength, sample volume, reagent volume, temperature and incubation. Useful for Routine Lipid Profiles Triglycerides are commonly measured together with: Total Cholesterol HDL Cholesterol LDL Cholesterol VLDL estimation Other lipid-related parameters Compatible with Open-System Biochemistry Analysers The Swemed Triglycerides Reagent is suitable for use on compatible open-system analysers where laboratories can program the required assay settings. Analyser Parameter Swemed Triglycerides Setting Method Endpoint Wavelength 505 nm Temperature 37°C Reagent Volume 1000 µl Sample Volume 10 µl Standard 200 mg/dL Incubation 15 min at room temperature or 10 min at 37°C Measurement Against Reagent Blank Unit mg/dL Reaction Direction Increasing The laboratory should verify analyser compatibility and validate the programmed application before reporting patient results. Intended Use The Swemed Triglycerides Liquid Stable Reagent is intended for the quantitative determination of triglycerides in serum and suitable plasma specimens by an enzymatic photometric GPO-PAP method. Swemed lists triglycerides for: Serum Plasma EDTA plasma Heparin plasma This product is intended for professional in vitro diagnostic laboratory use only. Test Principle Triglycerides are hydrolysed by lipoprotein lipase to form glycerol and free fatty acids. The glycerol undergoes further enzymatic reactions involving glycerol kinase and glycerol phosphate oxidase, producing hydrogen peroxide. In the presence of peroxidase, hydrogen peroxide reacts with the chromogen to form a coloured quinoneimine compound. The intensity of the resulting colour is proportional to the triglyceride concentration in the specimen. Technical Specifications Test Parameter Manufacturer Specification Parameter Triglycerides Method GPO-PAP Mode Endpoint Wavelength 505 nm Temperature 37°C Cuvette 10 mm path length Measurement Against Blank Reagent Volume 1000 µl Sample Volume 10 µl Standard Concentration 200 mg/dL Incubation at Room Temperature 15 minutes Incubation at 37°C 10 minutes Linearity 1000 mg/dL Unit mg/dL Assay Procedure Summary Tube Reagent Standard / Sample Blank 1000 µl — Standard 1000 µl 10 µl Standard Test 1000 µl 10 µl Sample Mix and incubate for: 15 minutes at room temperature or 10 minutes at 37°C Read the absorbance of the standard and test against the reagent blank at 505 nm. Calculation Triglycerides (mg/dL) = Absorbance of Sample ÷ Absorbance of Standard × Concentration of Standard The manufacturer states a standard concentration of 200 mg/dL. Specimen Requirements The manufacturer recommends: Fresh specimen Clear sample Non-haemolysed serum Fasting patient sample where clinically appropriate Swemed also notes that blood-collection devices lubricated with glycerin / glycerol should not be used, because glycerol can interfere with triglyceride measurement. Specimen Stability The Swemed technical insert states that triglycerides in serum remain stable for approximately: Storage Condition Stability 2–8°C 3 days Prolonged storage at room temperature is discouraged because hydrolysis of glycerol-containing compounds can produce an apparent increase in measured triglycerides. Interfering Substances Swemed identifies the following as potential interfering substances: Heparin EDTA Fluoride Oxalate Citrate The insert states these may inhibit the triglyceride assay and should be avoided in the manufacturer procedure. Lipemic or grossly icteric samples may also produce falsely elevated results. Because Swemed’s broader product listing describes EDTA and heparin plasma as supported sample types, laboratories should follow the current insert supplied with the actual reagent lot and their validated analyser application where specimen guidance differs. Measuring Range and Linearity The Swemed Triglycerides assay is stated to be linear up to: 1000 mg/dL Samples exceeding the validated measuring range should be handled according to the current manufacturer instructions and the laboratory’s validated dilution procedure. Manufacturer Expected Values The Swemed insert provides the following expected range: Parameter Manufacturer Expected Range Triglycerides 36–165 mg/dL Reference intervals can differ according to population, fasting status, laboratory method and clinical guidelines. Each laboratory should establish or verify an appropriate reference interval for its own patient population. Why Triglycerides Testing Is Important Triglycerides are esters of fatty acids and glycerol and represent an important form of lipid storage and transport in the body. Triglyceride testing is commonly used as part of investigations involving: Lipid-profile evaluation Hypertriglyceridaemia Dyslipidaemia Cardiovascular-risk assessment Diabetes mellitus Metabolic disorders Endocrine disturbances Nephrotic conditions Follow-up of lipid-management programmes Swemed notes that triglyceride testing is useful in the assessment of primary and secondary hyperlipoproteinaemia and may also be relevant in diabetes, nephrosis, biliary obstruction and metabolic abnormalities. Triglycerides in a Lipid Profile Parameter Laboratory Relevance Total Cholesterol Overall cholesterol measurement HDL Cholesterol High-density lipoprotein cholesterol LDL Cholesterol Low-density lipoprotein cholesterol Triglycerides Circulating triglyceride concentration VLDL Often estimated from triglyceride values Who Can Buy This Product? Buyer Type Typical Application Pathology Laboratories Routine triglyceride testing Diagnostic Centres Lipid profile investigations Hospital Laboratories Clinical chemistry testing Cardiology Centres Lipid and cardiovascular-risk profiles Diabetes Care Centres Metabolic and lipid testing Preventive Health Centres Routine lipid-profile screening Clinical Chemistry Laboratories Routine enzymatic testing Medical Institutions Diagnostic and teaching use Healthcare Organisations Institutional procurement Laboratory Distributors Professional supply where permitted Useful Tips Before Ordering Confirm that Triglycerides – GPO-PAP Method is required. Choose the correct pack: 50 ml or 2 × 50 ml. Confirm your analyser is an open system before programming third-party reagents. Ensure the analyser supports 505 nm endpoint measurement. Confirm 1000 µl reagent and 10 µl sample programming. Verify the standard concentration: 200 mg/dL. Follow current manufacturer instructions for sample type. Use fresh and properly handled specimens. Avoid glycerol-contaminated sample-collection equipment. Perform calibration and internal quality control before routine use. Verify analyser application and method performance before reporting patient results. Buy Swemed Triglycerides Reagent in Bangalore Microsidd India supplies lipid-profile reagents, clinical chemistry reagents and laboratory products from Bangalore / Bengaluru, Karnataka. The Swemed Triglycerides Liquid Stable Reagent is available in 50 ml and 2 × 50 ml pack variants and is suitable for pathology laboratories, diagnostic centres, hospitals and clinical chemistry facilities using compatible open-system analysers. The product can be ordered through microsidd.com, subject to stock availability and serviceability. Search Relevance This product is relevant for buyers searching for: Triglycerides reagent supplier in Bangalore Swemed Triglycerides Reagent Bangalore Triglycerides GPO PAP reagent Bengaluru Triglyceride reagent 50 ml Triglycerides reagent 2 × 50 ml Lipid profile reagent supplier Bangalore Triglyceride reagent for semi auto analyser Triglycerides reagent for fully automatic analyser Open system biochemistry reagent Bangalore Clinical chemistry reagent supplier near me Pathology lab reagent supplier Bangalore Swemed Triglycerides reagent online India Product Summary What is Swemed Triglycerides Liquid Stable Reagent? The Swemed Triglycerides Liquid Stable Reagent is a ready-to-use professional clinical chemistry reagent for quantitative triglyceride estimation using the GPO-PAP enzymatic endpoint method. Which pack sizes are available? 50 ml 2 × 50 ml Which method is used? The assay uses the GPO-PAP method. What wavelength is required? The manufacturer specifies 505 nm. What is the sample volume? The assay uses 10 µl sample. What is the reagent volume? The assay uses 1000 µl reagent. What is the triglyceride standard concentration? The manufacturer insert specifies 200 mg/dL. What is the linearity? The stated linearity is 1000 mg/dL. Is the reagent ready to use? Yes. The manufacturer lists both reagent and standard as ready to use. Is it suitable for semi-automatic analysers? Yes, for compatible open-system semi-automatic biochemistry analysers after application programming and method validation. Is it suitable for fully automatic analysers? Yes, for compatible open-system fully automatic biochemistry analysers that permit third-party reagent programming, subject to analyser compatibility and laboratory validation. Where can it be purchased? The product can be ordered from Microsidd India through microsidd.com, subject to availability. Entity Information Entity Details Product Triglycerides Liquid Stable Reagent Brand Swemed Diagnostics Pack Sizes 50 ml / 2 × 50 ml Analyte Triglycerides Method GPO-PAP Test Type Enzymatic Photometric Endpoint Wavelength 505 nm Standard 200 mg/dL Specimen Serum / Plasma Category Laboratory Reagents Subcategory Biochemistry Reagents Clinical Category Lipid Profile Analyser Compatibility Open-System Fully Automatic & Semi-Automatic Biochemistry Analysers Seller Microsidd India City Bangalore / Bengaluru State Karnataka Country India Website microsidd.com Buyer Type Laboratory / Hospital / Diagnostic Centre / B2B Why Buy Swemed Triglycerides Reagent from Microsidd.com? Lipid-profile reagents require careful procurement because laboratories need to verify the correct method, pack size, analyser compatibility, standard concentration, storage conditions, expiry and seller source. Microsidd India has long-standing experience in the IVD and diagnostic-products sector and focuses specifically on laboratory, diagnostic and healthcare products. This gives professional buyers an identifiable specialist procurement source instead of relying only on general marketplace listings. Microsidd.com vs Online Marketplaces vs Offline Suppliers Buying Factor Microsidd.com Large Online Marketplaces Offline / Local Suppliers Seller Specialisation Diagnostic and laboratory focused Seller expertise varies Depends on dealer Product Understanding Better suited to reagent-specific enquiries Often general marketplace support Dealer dependent Seller Identity Direct purchase from Microsidd India Marketplace and actual seller may differ Usually locally identifiable Pack Verification 50 ml / 2 × 50 ml can be confirmed before ordering Similar listings may cause confusion Depends on local stock Method Verification GPO-PAP can be confirmed Seller dependent Dealer dependent Analyser Compatibility Support Better suited to open-system analyser queries Often limited Depends on supplier knowledge GST Invoice Available for eligible purchases Seller dependent May vary B2B Procurement Suitable for labs, hospitals and institutions Seller dependent Usually local Product Range Specialist diagnostic and laboratory catalogue Broad but not specialised Usually limited Customer Support Direct Microsidd support Marketplace plus seller layer Local support Accountability One identifiable specialist supplier Seller may vary by listing Depends on supplier India-Wide Supply Subject to serviceability Broad Usually regional Benefits of Buying from Microsidd.com Microsidd Advantage Benefit to Laboratory Buyers Diagnostic Product Specialisation Better understanding of professional laboratory procurement Long-Standing IVD Experience Familiarity with clinical chemistry requirements Direct Seller Accountability Purchase directly from Microsidd India Product Verification Method and pack variants can be checked before purchase Open-System Analyser Support Easier verification of programmable settings GST Invoice Useful for professional and institutional procurement Multi-Category Procurement Lipid, liver, renal and cardiac reagents can be sourced together Bangalore-Based Operations Convenient for Bengaluru and Karnataka laboratories India-Wide Supply Delivery to serviceable locations across India Direct Customer Support Product and order-related queries handled directly Frequently Asked Questions What is Swemed Triglycerides Reagent used for? It is used for quantitative determination of triglycerides in serum/plasma by the GPO-PAP method. What pack sizes are available? The product is available in 50 ml and 2 × 50 ml variants. What method does the reagent use? It uses the GPO-PAP enzymatic method. What wavelength is used? The assay is read at 505 nm. What is the standard concentration? The standard concentration is 200 mg/dL. What is the sample volume? The assay uses 10 µl sample. What is the reagent volume? The assay uses 1000 µl reagent. What is the incubation time? Swemed specifies 15 minutes at room temperature or 10 minutes at 37°C. What is the linearity? The assay is linear up to 1000 mg/dL. Is the reagent ready to use? Yes. Swemed identifies both the reagent and standard as ready to use. Can it be used on semi-automatic biochemistry analysers? Yes, on compatible open-system semi-automatic analysers after programming and method validation. Can it be used on fully automatic biochemistry analysers? Yes, on compatible open-system fully automatic analysers that allow third-party reagent programming. Is this product for home testing? No. It is intended for professional in vitro diagnostic use only. Where can I buy Swemed Triglycerides Reagent in Bangalore? The product can be ordered through Microsidd India at microsidd.com, subject to stock availability. Medical and Laboratory Disclaimer The information on this product page is provided for general product identification, procurement and laboratory educational purposes only. This product is intended for professional in vitro diagnostic use by trained laboratory personnel. Triglyceride results should not be interpreted independently to diagnose or exclude cardiovascular disease, diabetes, metabolic disease or any other condition. Clinical interpretation should consider fasting status, total cholesterol, HDL, LDL, patient history and other relevant investigations. The information provided by Microsidd India does not replace the current Swemed Diagnostics package insert, analyser instructions, laboratory SOPs, calibration requirements, internal quality-control procedures or professional medical judgement. For open-system fully automatic and semi-automatic analysers, compatibility and application parameters must be programmed and validated by the laboratory before routine clinical use. Where older and newer manufacturer documents differ in specimen handling or pack configurations, the current label and package insert supplied with the actual reagent lot should be treated as the definitive specification. No Return / No Exchange Policy This product is non-returnable and non-exchangeable. Please verify the brand, model, compatibility, pack size and product specifications before placing your order. For laboratory reagents, customers should specifically verify the test parameter, methodology, analyser compatibility, reagent configuration and pack size before ordering. Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law. An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received. ## Product type: Biochemistry Reagents ## Vendor: Swemed Diagnostics ## Tags: Bio Chemistry Reagents, biochemistry ## Price range: 1800.0 - 3499.0 INR ## Link: https://microsidd.com/products/triglycerides-liquid-stable-reagent ## Options - Pack Size: 50ml, 100ml ## Collections - [All](https://microsidd.com/a/llms/collections/all) - [Laboratory Needs](https://microsidd.com/a/llms/collections/laboratory-needs) - [Bio Chemistry Reagents](https://microsidd.com/a/llms/collections/bio-chemistry-reagents) - [Swemed Diagnostics](https://microsidd.com/a/llms/collections/swemed-diagnostics) ## Variants - 50ml, SKU: TGL 50ml, Available: yes, Inventory: 0, Delivery profile: FreeShip India - 100ml, SKU: TGL 100ml, Available: yes, Inventory: 0, Delivery profile: FreeShip India ## Metafields - no_return_no_exchange_policy: true - title_tag: Swemed Triglycerides Reagent | 50ml & 2x50ml | GPO-PAP | Microsidd - description_tag: Buy Swemed Triglycerides Liquid Stable Reagent from Microsidd India, Bangalore. Available in 50 ml and 2 × 50 ml variants. Compatible with open-system fully automatic and semi-automatic biochemistry analysers after method validation. - badge: - widget:
- review_widget_data: {"number_of_reviews":0,"average_rating":"0.00","number_of_questions":0,"product_name":"Triglycerides Liquid Stable Reagent – 50 ml & 2 × 50 ml | GPO-PAP Method","product_external_id":10262875963712,"product_coupons_enabled":true,"image_url":null,"histogram":[{"rating":5,"frequency":0,"percentage":0,"extra_class":null},{"rating":4,"frequency":0,"percentage":0,"extra_class":null},{"rating":3,"frequency":0,"percentage":0,"extra_class":null},{"rating":2,"frequency":0,"percentage":0,"extra_class":null},{"rating":1,"frequency":0,"percentage":0,"extra_class":null}],"review_keywords":null,"product_medals":[],"custom_form_filters_and_averages":null,"photo_gallery":null,"review_summary_text":"Be the first to write a review","ai_summary_text":"","sort_key":"highest_rating","multi_language_sorting_enabled":false,"metafield_updated_at":"2026-09-13T00:57:14Z","reviews":[],"pagination":{"total_pages":0,"current_page":1,"per_page":5}} - google_product_category: 3002 - google_product_category: 3002