# Title: Meril Merilyzer EIAQuant ELISA Microplate Reader – 96 Well ## Description: Compact ELISA Reader for Professional Diagnostic Laboratories The Meril Merilyzer EIAQuant ELISA Microplate Reader is a professional laboratory instrument designed for photometric reading of 96-well microtiter plates used in ELISA and other absorbance-based microplate assays. The system is designed for laboratories that require a compact ELISA reader with automated plate feeding, absorbance measurement, result calculation, data processing, quality-control support and built-in printing. With standard wavelengths of 405 nm, 450 nm, 492 nm and 630 nm, monochromatic and bichromatic reading modes, fast plate-reading capability and an interactive LCD touch screen, the EIAQuant is suitable for diagnostic laboratories, blood banks, hospital laboratories, serology departments and other professional ELISA workflows. Product Information Brand: Meril DiagnosticsProduct Name: Merilyzer EIAQuantProduct Type: ELISA Microplate ReaderCategory: Laboratory InstrumentsSubcategory: ELISA Reader / Microplate ReaderPlate Format: 96-Well Microtiter PlateMeasurement: Absorbance / Optical DensityStandard Wavelengths: 405 nm, 450 nm, 492 nm, 630 nmAdditional Filter Positions: 3 Optional PositionsReading Modes: Monochromatic and BichromaticSingle-Wavelength Reading Speed: Approx. 6.5 SecondsDual-Wavelength Reading Speed: Approx. 16 SecondsOptical Density Range: 0–4.0 ODLight Source: HalogenOptical System: Eight-Channel Fibre OpticsDisplay: Large Interactive LCD Touch ScreenPrinter: Built-In Thermal PrinterQC: Up to 4 Levels of Control Sera with Levey-Jennings GraphFunctions: Self Diagnosis, Copy Test, Rerun, Automatic Feeding, Automatic Measurement, Data Analysis and ProcessingIntended Use: Professional Laboratory UseSuitable Users: Diagnostic laboratories, blood banks, hospital laboratories, serology laboratories, research and clinical laboratoriesSeller: Microsidd IndiaLocation: RT Nagar, Bengaluru, Karnataka What Is Merilyzer EIAQuant? The Merilyzer EIAQuant is a compact ELISA microplate reader used to measure the absorbance of samples processed in a 96-well microtiter plate. It is designed for laboratories performing qualitative and quantitative enzyme immunoassays where optical-density measurement is required. The instrument automates several parts of the reading workflow, including: plate feeding absorbance measurement data processing result analysis QC review report printing This makes it suitable for laboratories running routine ELISA assays for infectious disease, hormones and other compatible parameters. Key Features Four Standard Wavelength Filters The EIAQuant includes four standard spectral filters: 405 nm450 nm492 nm630 nm The system also provides three optional filter positions for additional assay requirements. Monochromatic & Bichromatic Reading The instrument supports both: Monochromatic reading and Bichromatic reading allowing laboratories to select the reading mode required by the assay protocol. Fast Plate Reading Meril lists the reading speed as approximately: 6.5 seconds at single wavelength and 16 seconds at dual wavelength for a compatible microplate. 0–4.0 OD Dynamic Range The instrument supports an optical-density range of 0 to 4.0 OD, providing a broad absorbance measurement range for compatible ELISA assays. Eight-Channel Fibre-Optic System The EIAQuant uses an eight-channel fibre-optic optical system, allowing efficient microplate reading. Halogen Light Source A halogen light source is used for absorbance measurement. Interactive Touch Screen A large LCD touch screen provides direct instrument control and easier laboratory operation. Built-In Thermal Printer The integrated thermal printer allows laboratories to generate results without requiring a separate external printer for routine reporting. Built-In Quality Control The EIAQuant supports up to four levels of control sera with a Levey-Jennings graph, helping laboratories monitor assay performance. Self-Diagnosis Function The system includes built-in self-diagnostic functionality to support routine instrument checks. Copy Test & Rerun Functions The instrument includes convenient workflow features such as: Copy Test and Rerun for repeat or related assay processing. Technical Specifications Specification Details Brand Meril Diagnostics Model Merilyzer EIAQuant Instrument Type ELISA Microplate Reader Plate Format 96-Well Microtiter Plate Measurement Absorbance / Optical Density Standard Filters 405, 450, 492, 630 nm Optional Filter Positions 3 Reading Modes Monochromatic / Bichromatic Single-Wavelength Speed Approx. 6.5 sec Dual-Wavelength Speed Approx. 16 sec OD Range 0–4.0 OD Light Source Halogen Optical System Eight-Channel Fibre Optics Display Large LCD Touch Screen Printer Built-In Thermal Printer QC Levels Up to 4 QC Display Levey-Jennings Graph Functions Self Diagnosis, Copy Test, Rerun Plate Feeding Automatic Measurement Automatic Data Analysis Automatic Intended Use Professional Laboratory Use How the ELISA Reader Works After an ELISA assay is completed in a 96-well plate, the microplate is placed into the EIAQuant. The instrument: feeds the plate into the optical system, reads absorbance at the selected wavelength, measures each well, processes the optical-density data, applies the programmed test calculation, generates qualitative or quantitative results according to the configured assay, displays or prints the final report. The exact wavelength, cut-off formula, calibration model and assay interpretation should be programmed according to the specific ELISA kit being used. Compatible ELISA Applications The EIAQuant can be used with compatible ELISA assays requiring microplate absorbance measurement. Typical applications may include: HIV ELISA HCV ELISA HBsAg ELISA Dengue ELISA Thyroid ELISA Hormone ELISA Infectious-disease ELISA Serology assays Quantitative immunoassays Qualitative ELISA screening Assay compatibility depends on the wavelength, plate format and protocol specified by the reagent manufacturer. Compatible Meril ELISA Kits The EIAQuant naturally complements Meril’s own ELISA range. Meril MeriLisa HIV ELISA – 96 Tests https://microsidd.com/products/merilisa-hiv-96t-pack Meril MeriLisa HCV ELISA 3.0 – 96 Tests https://microsidd.com/products/merilisa-hcv-elisa-3-0-96t-pack Meril MeriLisa HBsAg ELISA – 96 Tests https://microsidd.com/products/merilisa-hbsag-96t-pack Explore the Full ELISA Range https://microsidd.com/collections/elisa-range Your ELISA collection currently includes Meril HIV, HCV and HBsAg products alongside other professional ELISA kits, so linking this reader into that collection will make the category significantly stronger. Microsidd India ELISA Reader vs ELISA Washer The ELISA reader and ELISA washer perform different functions. Instrument Main Function ELISA Reader Measures optical density / absorbance ELISA Washer Washes microplate wells between assay steps The reader interprets the final colour reaction, while the washer is used during the assay workflow to remove unbound reagents. For a complete ELISA laboratory setup, both instruments may be required depending on the test protocol. Who Can Use This Instrument? The Merilyzer EIAQuant is intended for trained laboratory professionals working in: Diagnostic laboratories Blood banks Hospital laboratories Serology laboratories Clinical microbiology laboratories Pathology laboratories Medical colleges Research laboratories Institutional laboratories Public-health laboratories Transfusion-medicine laboratories This is a professional laboratory instrument and is not intended for household or consumer self-testing. Benefits for Diagnostic Laboratories The EIAQuant provides several practical benefits: compact laboratory footprint 96-well microplate reading fast reading times built-in printer touch-screen operation automatic plate feeding automatic measurement automated data analysis built-in QC functionality Levey-Jennings QC graphing monochromatic and bichromatic reading multiple filter options wide optical-density range Quality Control Features Quality-control monitoring is especially important in ELISA workflows. The EIAQuant supports: Up to 4 levels of control sera with Levey-Jennings graphical display This helps laboratories monitor control trends and detect shifts or analytical variation during routine testing. Calibration & Quantitative Testing The EIAQuant can support quantitative ELISA workflows where the assay requires calibration curves. The correct calibration model depends on the individual assay. Laboratories should use the calibration approach specified by the ELISA kit manufacturer rather than applying a generic calculation. Qualitative Testing & Cut-Off Analysis For qualitative ELISA assays, the reader can process optical-density values and apply assay-specific cut-off calculations. The instrument also supports grey-zone and reverse cut-off workflows where required by the programmed test method. Interpretation should always follow the individual assay IFU. Laboratory Setup Requirements A typical ELISA setup may include: Merilyzer EIAQuant reader ELISA microplate washer calibrated micropipettes disposable pipette tips ELISA reagent kits incubator where required refrigerator for reagent storage centrifuge where required timer laboratory computer if external data management is used appropriate PPE Installation & Operation The instrument should be installed on a stable, clean laboratory bench away from: direct sunlight excessive vibration moisture dust extreme temperature variation Installation, calibration and commissioning should follow the manufacturer's instructions. Only appropriately trained personnel should operate the reader. Cleaning & Maintenance Routine maintenance should follow Meril’s operating manual. General laboratory practices include: keep the instrument clean and dry avoid reagent spills inside the plate chamber clean external surfaces appropriately use only recommended service procedures avoid unauthorised disassembly periodically verify instrument performance perform preventive maintenance according to the manufacturer schedule Storage & Transportation For transport or relocation: use the original protective packaging where available protect the instrument from impact and vibration keep it dry avoid extreme temperature exposure transport in the correct orientation allow the instrument to acclimatise before operation after significant temperature changes perform verification after installation or relocation Exact transport and operating conditions should follow the current manufacturer manual. Explore Related Microsidd Collections ELISA Range https://microsidd.com/collections/elisa-range Blood Bank Range https://microsidd.com/collections/blood-bank-range Laboratory Reagents & Kits https://microsidd.com/collections/chemicals-liquids Why Buy Meril EIAQuant from Microsidd? Microsidd India supplies professional diagnostic equipment, laboratory reagents, ELISA kits and blood-bank products to healthcare and laboratory customers. Benefits include: ✓ Genuine brand-specific laboratory equipment✓ Meril ELISA kits available alongside the reader✓ Dedicated ELISA collection✓ Blood-bank and laboratory reagents available✓ Technical product information before ordering✓ Bengaluru-based support✓ GST invoice where applicable✓ Institutional supply support subject to availability✓ Online ordering for serviceable locations across India✓ Easier sourcing of compatible reagents and accessories from one supplier Buy ELISA Reader in Bangalore / Bengaluru Microsidd India supplies ELISA readers and professional diagnostic laboratory products in Bengaluru and serves laboratories across serviceable locations in India. Professional buyers searching for: ELISA reader Bangaloremicroplate reader BengaluruMeril ELISA reader96 well ELISA reader IndiaELISA equipment near meblood bank ELISA equipment Bangalore order through Microsidd.com subject to stock and serviceability. Microsidd India – NAP Business Name: Microsidd IndiaAddress: #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, IndiaPhone / WhatsApp: +91 63667 72288Email: support@microsidd.comWebsite: https://microsidd.comWorking Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST Find Microsidd India on Google Maps https://www.google.com/maps/search/?api=1&query=Microsidd+India%2C+09+Green+Chambers%2C+14th+Cross%2C+RT+Nagar%2C+Bengaluru+560032 Stay Connected with Microsidd Subscribe to Microsidd on YouTube For laboratory product videos, diagnostic guides and product explainers: https://www.youtube.com/channel/UCun9gCID17Z5kK65W6JtIdg?sub_confirmation=1 Follow the Microsidd WhatsApp Channel For updates about new diagnostic products, laboratory equipment and offers: https://whatsapp.com/channel/0029Va5lCoi1nozBZBL1gx3P Frequently Asked Questions What is the Meril Merilyzer EIAQuant? It is a professional 96-well ELISA microplate reader used to measure absorbance in ELISA and compatible microplate assays. Meril Life What plate size does it support? It is designed for 96-well microtiter plates. Which wavelengths are included? The standard filters are: 405 nm, 450 nm, 492 nm and 630 nm. Are additional filters available? Yes. The instrument has three optional filter positions. Does it support dual-wavelength reading? Yes. It supports both monochromatic and bichromatic reading. What is the reading speed? Meril lists approximately 6.5 seconds at single wavelength and 16 seconds at dual wavelength. What is the optical-density range? The instrument supports a 0–4.0 OD dynamic range. Does it have a built-in printer? Yes. It includes a built-in thermal printer. Does it have a touch screen? Yes. It uses a large interactive LCD touch screen. Does it support quality control? Yes. It supports up to four levels of control sera with Levey-Jennings graphing. Can it be used for HIV ELISA? Yes, if the HIV ELISA assay uses compatible wavelengths and a 96-well plate. Can it be used for HCV ELISA? Yes, subject to assay compatibility and programming. Can it be used for HBsAg ELISA? Yes, subject to the assay IFU and wavelength requirements. Can it be used for quantitative ELISA? Yes, where the assay requires absorbance-based quantitative calculation and the appropriate calibration model is programmed. Can it be used for qualitative ELISA? Yes. Does the instrument automatically analyse data? Yes. Meril describes automatic measurement, data analysis and processing. Does it include self-diagnosis? Yes. Self Diagnosis is one of the listed functions. Can the test be rerun? The instrument includes a Rerun option. Is this product for home use? No. It is professional laboratory equipment. Does an ELISA reader perform washing? No. Plate washing is normally performed with an ELISA washer or validated manual washing process. Does Microsidd also supply ELISA kits? Yes. Browse: https://microsidd.com/collections/elisa-range Does Microsidd supply blood-bank products? Yes. https://microsidd.com/collections/blood-bank-range No Return / No Exchange Policy This product is non-returnable and non-exchangeable, has 2 years warranty Please verify the brand, model, application, wavelength requirements, plate compatibility, assay requirements, instrument specifications and installation requirements before placing your order. For laboratory equipment, customers should specifically verify the required test methodology, compatible ELISA kit, wavelength, plate format, laboratory infrastructure and intended workflow before ordering. Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law. An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received. Professional / Laboratory Disclaimer The Meril Merilyzer EIAQuant is intended for professional laboratory use. The instrument must be installed, operated, calibrated and maintained by appropriately trained personnel according to the manufacturer’s current operating instructions, laboratory SOPs, quality-control procedures and applicable regulatory requirements. Test results depend on the performance of the complete analytical system, including the assay kit, specimen quality, instrument programming, wavelength selection, calibration, QC and laboratory procedure. Clinical decisions should not be based solely on an instrument reading without appropriate assay validation and professional interpretation. ## Product type: ## Vendor: MERIL DIAGNOSTICS ## Tags: ## Price range: 159000.0 - 159000.0 INR ## Link: https://microsidd.com/products/meril-merilyzer-eiaquant-elisa-reader ## Compare-at price range: 320000.0 - 320000.0 INR ## Options - Title: Default Title ## Collections - [All](https://microsidd.com/a/llms/collections/all) - [Lab Equipments](https://microsidd.com/a/llms/collections/lab-equipments) - [Elisa Range](https://microsidd.com/a/llms/collections/elisa-range) ## Variants - Default Title, SKU: Meril EIA Reader, Available: yes, Inventory: 0, Delivery profile: Standard Shipping ## Metafields - color-pattern: ["gid://shopify/Metaobject/61829054784"] - expiry_date: 2 Year Warranty - no_return_no_exchange_policy: true - title_tag: Meril EIAQuant ELISA Reader 96 Well | Microsidd India - description_tag: Buy Meril Merilyzer EIAQuant ELISA Microplate Reader with 96-well reading, 405/450/492/630 nm filters, touch screen, QC and thermal printer from Microsidd India. - google_product_category: 7393 - google_product_category: 7393 - badge:
- widget: - review_widget_data: {"number_of_reviews":0,"average_rating":"0.00","number_of_questions":0,"product_name":"Meril Merilyzer EIAQuant ELISA Microplate Reader – 96 Well","product_external_id":15395104555328,"product_coupons_enabled":true,"image_url":"https://cdn.shopify.com/s/files/1/0767/8224/0064/files/Merilyzer_EIA_Quantelisareader.png?v=1790445244","histogram":[{"rating":5,"frequency":0,"percentage":0,"extra_class":null},{"rating":4,"frequency":0,"percentage":0,"extra_class":null},{"rating":3,"frequency":0,"percentage":0,"extra_class":null},{"rating":2,"frequency":0,"percentage":0,"extra_class":null},{"rating":1,"frequency":0,"percentage":0,"extra_class":null}],"review_keywords":null,"product_medals":[],"custom_form_filters_and_averages":null,"photo_gallery":null,"review_summary_text":"Be the first to write a review","ai_summary_text":"","sort_key":"highest_rating","multi_language_sorting_enabled":false,"metafield_updated_at":"2026-09-26T17:59:13Z","reviews":[],"pagination":{"total_pages":0,"current_page":1,"per_page":5}}