# Title: Meril MeriSera Anti A, Anti B & Anti D Blood Grouping Kit 3×10 mL ## Description: Meril MeriSera Anti-ABD Blood Grouping Reagent Kit – ABO & Rh(D) Typing The Meril MeriSera Anti A, Anti B & Anti D Blood Grouping Kit – 3 × 10 mL is a professional in-vitro diagnostic antisera reagent kit intended for the determination of ABO blood group antigens and Rh(D) antigen on human red blood cells. The kit combines Anti-A, Anti-B and Anti-D blood grouping reagents in one convenient laboratory pack for routine ABO and Rh blood typing. Meril identifies the combo as MeriSera Anti A, B, D Combo Pack, reference ABDSER-01, supplied as 3 × 10 mL. The manufacturer describes the reagents as suitable for determination of antigens of the ABO and Rh blood group systems and reports standardization in accordance with AABB guidelines. Product Information Brand: Meril DiagnosticsProduct Family: MeriSeraProduct Name: Anti A, Anti B & Anti D Blood Grouping KitCommon Name: Anti-ABD Blood Grouping KitManufacturer Reference: ABDSER-01Category: Laboratory Reagents / Blood Grouping ReagentsSubcategory: Antisera / Immunohematology / Blood Bank ReagentsTest System: ABO and Rh(D) Blood GroupingReagents Included: Anti-A + Anti-B + Anti-DPack Size: 3 × 10 mLTotal Reagent Volume: 30 mLIntended Specimen: Human red blood cells / appropriately collected blood specimenDetection Principle: Visible red-cell agglutinationTesting Application: ABO forward grouping and Rh(D) typingMethods: Slide and tube blood grouping methods according to current manufacturer IFU and laboratory SOPStorage: Refrigerated at 2–8°C; do not freezeIntended User: Trained laboratory and healthcare professionalsUse: Professional in-vitro diagnostic use onlySeller: Microsidd IndiaLocation: RT Nagar, Bengaluru, Karnataka, India What Is the Meril Anti-ABD Blood Grouping Kit? The MeriSera Anti-ABD Kit contains three blood grouping antisera used to identify major red-cell antigens involved in routine ABO and Rh typing. Anti-A reagent reacts with red blood cells carrying A antigen. Anti-B reagent reacts with red blood cells carrying B antigen. Anti-D reagent is used to determine the presence of the clinically important Rh(D) antigen. Visible agglutination patterns produced when the correct reagent is mixed with the patient's or donor's red cells are interpreted by trained laboratory personnel to establish the ABO/Rh(D) grouping result. Meril’s brochure states that its Anti-A reagent reacts with A1, A2 and several weaker A phenotypes, while Anti-B reacts with B and AB group red cells. The manufacturer's blood-grouping range also includes Rh(D) reagents designed for Rh typing. What Is Included? The Meril MeriSera Anti-ABD Combo Pack – 3 × 10 mL contains: Reagent Quantity Anti-A Blood Grouping Reagent 1 × 10 mL Anti-B Blood Grouping Reagent 1 × 10 mL Anti-D Blood Grouping Reagent 1 × 10 mL Total Volume 30 mL Manufacturer Reference: ABDSER-01. Product Features Complete ABO + Rh(D) Combination Three principal blood grouping antisera are supplied together in one pack, allowing laboratories to perform routine ABO and Rh(D) typing workflows. 3 × 10 mL Professional Laboratory Pack The manufacturer's current brochure lists the MeriSera Anti-A/B/D combo as 3 × 10 mL. Visible Agglutination Reaction Blood grouping is based on antigen-antibody agglutination, allowing trained professionals to observe reactions according to the applicable test method and laboratory SOP. High Avidity Meril reports avidity of: Anti-A and Anti-B: <4 secondsAnti-D: <10 seconds under the manufacturer's stated testing conditions. Manufacturer-Listed Titre Meril reports a titre of >1:256 for the combo range in its current antisera brochure. Slide & Tube Applications Meril's blood-grouping literature describes correlation with slide and tube testing, while individual MeriSera reagents provide procedures for these laboratory methods. Professional IVD Product This is a laboratory blood grouping reagent, not a consumer home blood-group test. Key Benefits The Meril Anti-ABD Kit provides a practical single-kit format for laboratories that routinely perform ABO and Rh(D) typing. The three-reagent configuration reduces the need to procure Anti-A, Anti-B and Anti-D separately, while Meril's colour-coded and agglutination-based antisera range is designed to facilitate clear reaction interpretation by trained professionals. It is particularly useful where laboratories require repeat access to standard ABO and Rh(D) blood grouping reagents as part of routine diagnostic, blood-bank or institutional workflows. Manufacturer Performance Information According to Meril's current antisera brochure: Parameter Manufacturer Information Anti-A avidity <4 sec Anti-B avidity <4 sec Anti-D avidity <10 sec Titre >1:256 ABO application Determination of ABO-system antigens Rh application Determination of Rh-system antigens Pack reference ABDSER-01 Pack size 3 × 10 mL Meril also states that its Anti-A reacts with multiple A phenotypes and its Anti-B reacts with B and AB red cells under the manufacturer's test conditions. Who Can Use This Product? The Meril MeriSera Anti-ABD Blood Grouping Kit is intended for appropriately trained personnel working in professional healthcare or diagnostic environments, including: Diagnostic laboratories Pathology laboratories Hospital laboratories Blood banks and transfusion services Medical colleges and teaching laboratories Institutional clinical laboratories Qualified laboratory technicians Pathologists and laboratory physicians Other authorised healthcare facilities performing blood grouping This kit should not be marketed as a home self-testing product. Typical Laboratory Applications This reagent kit may be used as part of appropriate professional workflows for: ABO forward blood grouping Rh(D) typing Donor blood grouping Patient blood grouping Pre-transfusion laboratory workflows Antenatal blood-group testing Hospital and pathology laboratory blood typing Teaching and demonstration in authorised laboratory settings Blood grouping for transfusion purposes must be performed and verified according to institutional SOPs, applicable blood-bank standards, quality-control procedures and relevant regulatory requirements. How the Test Works Blood grouping antisera contain antibodies that react with corresponding antigens on red blood cells. For example: Agglutination with Anti-A indicates the presence of A antigen. Agglutination with Anti-B indicates the presence of B antigen. Agglutination with Anti-D indicates the presence of Rh(D) antigen. The complete reaction pattern is interpreted by trained laboratory professionals to assign ABO and Rh(D) type. Exact reagent volumes, cell preparation, centrifugation, incubation, controls and interpretation criteria should be taken from the current Meril Instructions for Use and the laboratory's validated SOP rather than from a generic e-commerce procedure. Technical Specifications Specification Details Brand Meril Diagnostics Product Family MeriSera Product Anti-A, Anti-B & Anti-D Combo Reference ABDSER-01 Category Blood Grouping Antisera Testing System ABO + Rh(D) Pack Size 3 × 10 mL Total Volume 30 mL Anti-A 10 mL Anti-B 10 mL Anti-D 10 mL Principle Red-cell agglutination Methods Slide / Tube, according to IFU Storage 2–8°C Freezing Do Not Freeze Use Professional IVD Manufacturer Meril Diagnostics Pvt. Ltd., India The manufacturer brochure confirms ABDSER-01 and the 3 × 10 mL pack. Meril antisera IFUs specify refrigerated storage at 2–8°C and advise against freezing. Storage Blood-grouping antisera are temperature-sensitive diagnostic reagents. Meril's antisera instructions specify: Store at 2–8°C.Do not freeze. Reagents should be returned promptly to refrigerated storage after use and kept tightly closed to reduce contamination and deterioration. Prolonged storage outside the recommended temperature range may reduce reagent reactivity. Also: Do not use beyond the expiry date printed on the supplied pack. Do not use a reagent showing abnormal turbidity or suspected contamination. Avoid unnecessary exposure to heat. Follow the current carton and IFU storage instructions if they differ from general website information. Transportation & Receiving the Reagent Transport should be managed so that the reagent is protected from significant heat exposure and from freezing. On receipt: Inspect the package promptly. Verify the product, pack size and reagent bottles. Check the labelled expiry and batch information. Place the reagent into appropriate 2–8°C refrigerated storage as soon as practicable. Do not freeze. Follow your laboratory's reagent-receiving and temperature-control SOP. For professional laboratories purchasing temperature-sensitive reagents, the manufacturer's labelled storage requirements should always take precedence. Important Precautions This product is for in-vitro diagnostic use only. Meril's antisera literature advises that testing should be performed by competent and trained personnel. The reagent range uses sodium azide as a preservative, and appropriate laboratory precautions should be followed. Laboratory personnel should: wear appropriate PPE treat all human specimens as potentially infectious prevent cross-contamination use clean, properly labelled laboratory materials use appropriate positive and negative controls where required follow institutional biological-waste disposal procedures follow the manufacturer's current IFU Related Laboratory & Blood Grouping Products Customers looking for related professional laboratory reagents can explore: Laboratory Reagents & KitsBrowse Laboratory Reagents & Kits Anti Sera CollectionBrowse Anti Sera & Blood Grouping Reagents Blood Bank RangeExplore Blood Bank Products Why Buy Meril Anti-ABD Kit from Microsidd? Microsidd India is a Bengaluru-based diagnostic and healthcare-products supplier serving laboratories, healthcare professionals and customers through Microsidd.com. The current company page identifies its RT Nagar, Bengaluru location and confirms supply of diagnostic products and laboratory consumables across serviceable locations in India. Microsidd India Benefits of ordering through Microsidd include: Professional laboratory and diagnostic-product catalogue Multiple blood grouping reagent brands available for comparison Clear product identification and pack-size information Related antisera, serology and laboratory supplies available GST invoice where applicable Bengaluru-based support Online ordering for serviceable PIN codes across India Product and compatibility information before purchase Bulk/institutional requirements may be supported subject to availability For this temperature-sensitive product, customers should verify any special dispatch or delivery requirements before placing a time-critical order. Buy Anti-ABD Blood Grouping Kit in Bangalore / Bengaluru Microsidd supplies laboratory reagents and blood-grouping products from RT Nagar, Bengaluru, with online ordering available to serviceable locations across India. Customers searching for Anti ABD blood grouping kit in Bangalore, blood grouping reagent Bengaluru, Anti A Anti B Anti D kit near me, blood bank reagents Bangalore, or Meril blood grouping kit India can order through Microsidd.com subject to stock and serviceability. Microsidd India Business: Microsidd IndiaAddress: #09, Green Chambers, 14th Cross, RT Nagar, Bengaluru – 560032, Karnataka, IndiaCustomer Support: +91 63667 72288Email: support@microsidd.comWebsite: Microsidd.comWorking Hours: Monday to Saturday, 10:00 AM – 6:00 PM IST These details are also published on Microsidd's current About page. Microsidd India Find Microsidd India on Google Maps Stay Connected with Microsidd Subscribe on YouTube Follow Microsidd for product explainers, diagnostic-product information, laboratory supplies and healthcare videos. Subscribe to Microsidd on YouTube Join the Microsidd WhatsApp Channel Get updates about new products, diagnostic supplies, offers and useful product information. Follow the Microsidd WhatsApp Channel Frequently Asked Questions What is the Meril Anti-ABD Blood Grouping Kit? It is a professional antisera reagent kit containing Anti-A, Anti-B and Anti-D reagents for ABO and Rh(D) blood grouping. What is the exact Meril product name? Meril identifies it as the MeriSera Anti A, B, D Combo Pack. What is the manufacturer reference number? The manufacturer's catalogue reference is ABDSER-01. What is the pack size? The kit contains 3 × 10 mL, providing a total of 30 mL reagent. Which reagents are included? The pack contains: Anti-A – 10 mLAnti-B – 10 mLAnti-D – 10 mL What does Anti-A detect? Anti-A is used to detect A antigens on human red blood cells. What does Anti-B detect? Anti-B is used to detect B antigens on human red blood cells. What does Anti-D detect? Anti-D is used to determine the presence of the Rh(D) antigen. Can this kit determine ABO and Rh blood group? Yes. The combo is designed for determination of antigens of the ABO and Rh systems. What test principle is used? The test is based on visible antigen-antibody agglutination of red blood cells. Can it be used by slide method? Meril's blood-grouping range supports slide and tube testing according to the applicable manufacturer instructions. Can it be used by tube method? Yes, where performed according to the current Meril IFU and laboratory SOP. How should the Meril Anti-ABD kit be stored? Meril's antisera instructions specify 2–8°C refrigeration. Can the reagents be frozen? No. Meril's antisera IFUs state do not freeze. Can this kit be used at home? No. This is a professional IVD reagent intended for appropriately trained personnel. Can a blood grouping result be used directly for transfusion? Blood-grouping results used for transfusion decisions must be obtained and verified according to appropriate blood-bank procedures, compatibility testing, controls, institutional SOPs and applicable regulatory standards. Is this the same as an HIV, HCV or infectious-disease rapid test? No. Anti-A, Anti-B and Anti-D reagents are blood-grouping antisera. They do not test for HIV, HCV or other infectious diseases. Does this product require ELISA or PCR confirmation? No. ELISA/PCR is not an appropriate generic confirmation statement for ABO/Rh blood grouping. The old Microsidd description containing that wording should be removed. Who should use this product? Trained laboratory technicians, pathologists, blood-bank professionals and other appropriately qualified healthcare personnel. What should I verify before ordering? Verify: Brand Anti-A/B/D requirement Pack size Test methodology Storage capability Intended laboratory application Current expiry requirement No Return / No Exchange Policy This product is non-returnable and non-exchangeable. Please verify the brand, product, methodology, reagent configuration, pack size, intended application and storage requirements before placing your order. For laboratory reagents, customers should specifically verify the required test parameter, methodology, analyser or workflow compatibility, reagent configuration and pack size before ordering. Genuine cases involving an incorrect product received will be handled separately according to Microsidd.com's applicable policies and applicable law. An original, continuous, unedited and uncut unboxing video is compulsory for making any claim regarding an incorrect product received. Professional / Medical Disclaimer The Meril MeriSera Anti-A, Anti-B & Anti-D Blood Grouping Kit is intended for professional in-vitro diagnostic use only. The product should be handled and testing performed by appropriately trained personnel according to the manufacturer's current Instructions for Use, laboratory SOPs, quality-control procedures and applicable regulatory or blood-bank requirements. Blood-grouping results used for transfusion, antenatal management or other clinical decisions must be interpreted and verified by qualified professionals. A single unverified reaction should not be used independently to make transfusion decisions. The product does not test for transfusion-transmissible infections and should not be represented as an HIV, hepatitis or infectious-disease screening kit. ## Product type: ## Vendor: MERIL DIAGNOSTICS ## Tags: Anti Sera, Chemicals & liquids, Laboratory Needs, Serology, shipping charged ## Price range: 599.0 - 599.0 INR ## Link: https://microsidd.com/products/anti-abd-blood-grouping-kit-meril ## Compare-at price range: 820.0 - 820.0 INR ## Options - Title: Default Title ## Collections - [All](https://microsidd.com/a/llms/collections/all) - [Serology](https://microsidd.com/a/llms/collections/serology) - [Chemicals & liquids](https://microsidd.com/a/llms/collections/chemicals-liquids) - [Anti Sera](https://microsidd.com/a/llms/collections/anti-sera) - [Laboratory Needs](https://microsidd.com/a/llms/collections/laboratory-needs) ## Variants - Default Title, SKU: MERIL ABD GROUPING, Available: yes, Inventory: 8, Delivery profile: Standard Shipping ## Metafields - description_tag: Buy Meril MeriSera Anti-A, Anti-B & Anti-D Blood Grouping Kit 3×10mL for professional ABO and Rh(D) typing. Order laboratory antisera from Microsidd India - title_tag: Meril Anti A B D Blood Grouping Kit 3×10mL | Microsidd - length: 15.0 - width: 10.0 - height: 10.0 - weight: {"value":100.0,"unit":"GRAMS"} - condition: new - badge: - widget:
- rating: {"scale_min":"1.0","scale_max":"5.0","value":"5.0"} - rating_count: 2 - google_product_category: 4255 - google_product_category: 4255 - expiry_date: 07-2028 - no_return_no_exchange_policy: true - color-pattern: ["gid://shopify/Metaobject/61829054784"] - chemical-grade: ["gid://shopify/Metaobject/145995301184","gid://shopify/Metaobject/158230315328"] - review_widget_data: {"number_of_reviews":2,"average_rating":"5.00","number_of_questions":0,"product_name":"Meril MeriSera Anti A, Anti B & Anti D Blood Grouping Kit 3×10 mL","product_external_id":8349162701120,"product_coupons_enabled":true,"image_url":"https://cdn.shopify.com/s/files/1/0767/8224/0064/files/Meril_Anti_A_B_D_Blood_Grouping_Kit_3x10mL_Microsidd.png?v=1790436202","histogram":[{"rating":5,"frequency":2,"percentage":100,"extra_class":null},{"rating":4,"frequency":0,"percentage":0,"extra_class":null},{"rating":3,"frequency":0,"percentage":0,"extra_class":null},{"rating":2,"frequency":0,"percentage":0,"extra_class":null},{"rating":1,"frequency":0,"percentage":0,"extra_class":null}],"review_keywords":null,"product_medals":[],"custom_form_filters_and_averages":null,"photo_gallery":null,"review_summary_text":"Based on 2 reviews","ai_summary_text":"","sort_key":"highest_rating","multi_language_sorting_enabled":false,"metafield_updated_at":"2026-10-18T03:59:23Z","reviews":[{"uuid":"977cee46-f974-4dfb-a10d-cfd636c59be1","title":"","rating":5,"body_html":"

Anti Abd Blood Grouping Kit Meril

","body":"Anti Abd Blood Grouping Kit Meril","verified_buyer":true,"created_at":"2025-06-21T11:42:41.264Z","reviewer_name":"Neuberg Diagnostics S Godwinraja","reviewer_initial":"N","is_anonymous_reviewer":false,"cf_answers":[],"reply_content":null,"pictures_urls":[],"video_external_ids":[],"thumb_up":0,"thumb_down":0,"location_country":"","location_country_code":"","location":"","source":null,"product_title":"Meril MeriSera Anti A, Anti B & Anti D Blood Grouping Kit 3×10 mL","encoded_product_id":"DAJzor8x","encoded_shop_id":"dgbKz74D","is_shopify_lite":false,"product_url":"/products/anti-abd-blood-grouping-kit-meril","product_url_with_utm":"https://microsidd.com/products/anti-abd-blood-grouping-kit-meril?jdgm_referral_location=widget&ref=judge.me&utm_campaign=judgeme-review-site&utm_medium=referral&utm_source=judgeme","product_in_store":true,"product_variant_title":"","profile_img_idx":3,"avatar_image_url":null,"gravatar_hash":null,"media_platform_hosted_video_infos":[],"country_code_show_flag":null,"pinned":null,"in_a_group":false,"can_pin":true,"shop_reply_name":"Microsidd India","transparency_badges":["review_collected_via_store_invitation"],"language":null,"is_for_product_from_group":false,"product_variant_image_url":"https://cdn.shopify.com/s/files/1/0767/8224/0064/files/Meril_Anti_A_B_D_Blood_Grouping_Kit_3x10mL_Microsidd.png?v=1790436202","is_for_product_from_bundle":false,"product_title_localized":null},{"uuid":"469bedc6-6f5c-44d6-87c5-5180cbfb79fb","title":"","rating":5,"body_html":"

Anti Abd Blood Grouping Kit Meril

","body":"Anti Abd Blood Grouping Kit Meril","verified_buyer":true,"created_at":"2023-08-03T05:53:22.693Z","reviewer_name":"Rahul Garg","reviewer_initial":"R","is_anonymous_reviewer":false,"cf_answers":[],"reply_content":null,"pictures_urls":[],"video_external_ids":[],"thumb_up":0,"thumb_down":0,"location_country":"","location_country_code":"","location":"","source":null,"product_title":"Meril MeriSera Anti A, Anti B & Anti D Blood Grouping Kit 3×10 mL","encoded_product_id":"DAJzor8x","encoded_shop_id":"dgbKz74D","is_shopify_lite":false,"product_url":"/products/anti-abd-blood-grouping-kit-meril","product_url_with_utm":"https://microsidd.com/products/anti-abd-blood-grouping-kit-meril?jdgm_referral_location=widget&ref=judge.me&utm_campaign=judgeme-review-site&utm_medium=referral&utm_source=judgeme","product_in_store":true,"product_variant_title":"","profile_img_idx":7,"avatar_image_url":null,"gravatar_hash":null,"media_platform_hosted_video_infos":[],"country_code_show_flag":null,"pinned":null,"in_a_group":false,"can_pin":true,"shop_reply_name":"Microsidd India","transparency_badges":["review_collected_via_store_invitation"],"language":null,"is_for_product_from_group":false,"product_variant_image_url":"https://cdn.shopify.com/s/files/1/0767/8224/0064/files/Meril_Anti_A_B_D_Blood_Grouping_Kit_3x10mL_Microsidd.png?v=1790436202","is_for_product_from_bundle":false,"product_title_localized":null}],"pagination":{"total_pages":1,"current_page":1,"per_page":5}} - review_widget_ssr_html:
  • 5 stars: 2 (100%)
  • 4 stars: 0 (0%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
N
Neuberg Diagnostics S Godwinraja

Anti Abd Blood Grouping Kit Meril

R
Rahul Garg

Anti Abd Blood Grouping Kit Meril

- review_widget_json_ld: {"@context":"https://schema.org/","@type":"Product","@id":"/products/anti-abd-blood-grouping-kit-meril#product","name":"Meril MeriSera Anti A, Anti B & Anti D Blood Grouping Kit 3×10 mL","aggregateRating":{"@type":"AggregateRating","ratingValue":"5.00","reviewCount":2,"bestRating":5,"worstRating":1},"image":"https://cdn.shopify.com/s/files/1/0767/8224/0064/files/Meril_Anti_A_B_D_Blood_Grouping_Kit_3x10mL_Microsidd.png?v=1790436202","review":[{"@type":"Review","reviewRating":{"@type":"Rating","ratingValue":5,"bestRating":5,"worstRating":1},"author":{"@type":"Person","name":"Neuberg Diagnostics S Godwinraja"},"reviewBody":"Anti Abd Blood Grouping Kit Meril","datePublished":"2025-06-21T11:42:41Z"},{"@type":"Review","reviewRating":{"@type":"Rating","ratingValue":5,"bestRating":5,"worstRating":1},"author":{"@type":"Person","name":"Rahul Garg"},"reviewBody":"Anti Abd Blood Grouping Kit Meril","datePublished":"2023-08-03T05:53:22Z"}]}